Gas Engines Intake/Exhaust Systems

Exhaust System Installation Guidelines

1. Allow for thermal expansion of the exhaust pipe 3. Design the exhaust system so it will not impose
beyond the Waukesha* flex. The Waukesha exhaust torsional forces on the exhaust flex connection.
flex (when supplied) will accommodate engine
4. The exhaust flex connection should be designed to
thermal expansion but cannot tolerate movement
allow for flexing caused by engine operation,
imposed by external thermal growth. Insulated pipes
acceleration, deceleration, starting and stopping. The
will run hotter and consequently expand more.
Waukesha exhaust flex (when supplied) will
COEFFICIENT OF EXPANSION accommodate engine vibrations with a solidly
mounted unit, but cannot tolerate the additional
Steel 0.00065 in/in/100°F
forces/displacement imposed by mounting on spring
Stainless steel 0.00099 in/in/100°F isolators. Additional flex capabilities will be required
when the unit is mounted on isolators.
EXAMPLE: 10 ft. of steel pipe on a L7042G with an
exhaust temperature of 1060°F will expand based on 5. Consider expected life. Cyclic flexing can lead to
60°F ambient. (0.00065 in/in/100°F) (10 ft) (12 in/ft) premature failure by causing fatigue breakage.
(1060°-60°/100 ) = .78 in.
6. Utilize a combination of fixed supports, rollers and
2. Remember that a flex connection has “spring flex connections to provide a well designed exhaust
constants” (lateral, axial, radial, torsional) that should system. See sketches for additional concepts.
be considered when engineering the exhaust system.
7. Provide water traps/drains to prevent exhaust
Transmission of forces to the engine exhaust system
condensation and/or rain from reaching the engine.
(engine exhaust flange) must be nil. (Any specific load
This is especially true on long pipe runs. Use rain
or bending moment limits shown on an engine’s
caps where applicable. Slope piping away from
installation drawing must not be exceeded.)
engine.

AXIAL LATERAL

RADIAL TORSIONAL

Page 1 of 4

EN: 112676
Ref.
Exhaust System Installation Guidelines S
DATE: 11/96
8242
GE Energy
Gas Engines Intake/Exhaust Systems
8. The minimum requirements for the design of the convergence of the two exhaust streams to produce
exhaust system should be to contain explosions that proper flow and restriction balance. Convergence
could be encountered during the operation of the angle from the center of symmetry must not exceed
engine. Waukesha recommends the use of carbon 45 degrees. The outlet area of the y-connection must
steel schedule 20 pipe as a minimum. Stainless steel be equal to or greater than the sum of the two inlet
schedule 10 pipe is preferred because of its greater areas.
strength properties at elevated temperatures.
11. Size piping and silencer so that exhaust system back
Waukesha does not recommend using double walled
pressure, as measured at the engine outlet flange, is
piping or slip joints on engine exhausts.
less than that indicated in the specifications page in
9. Utilize smooth transition to final pipe size when a the tech data book.
transition in size is required. Waukesha recommends
12. Provide clearance to permit use of a chain hoist for
a diverging angle of 15 degrees for low pressure drop
removal of heavy components.
(see sketches for straight and elbowed transitions).
13. For other exhaust system parameters see chapter
10. Engines with two exhaust outlets combined into one
seven, (Exhaust System) of the “Waukesha
(such as 12VAT25GL engine) must have a
Installation Manual” (Form 1091.
symmetrical design up to and including the point of

Page 2 of 4

EN: 112676
Ref.
Exhaust System Installation Guidelines S
DATE: 11/96
8242
GE Energy
Gas Engines Intake/Exhaust Systems

EXHAUST OUTLET FLANGE (125#)


(SEE INSTALLATION DRAWING
FOR FLANGE SIZE)

TYPICAL
WAUKESHA
EXHAUST + 0.0 + 0.0
FLEX
EXHAUS EXHAUST SYSTEM MUST
T + 0.0 SUPPORT ITS OWN WEIGHT
+ 0.0 AND THERMAL EXPANSION
+ 0.0
BEYOND THIS POINT SEE NOTE 3

+ 0.0

EXHAUST OUTLET FLANGE TYPICAL EXHAUST SYSTEM EXAMPLE:


*MAXIMUM DISTORTION DUE TO CUSTOMERS PIPING OTHER SYSTEMS UTILIZING LONGER PIPE RUNS, HEAT SEE
RECOVERY EQUIPMENT. CATALYTIC CONVERTER, ETC. NOTE 11
CAN BE ENGINEERED USING SIMILAR CONCEPTS.

SEE NOTE 3

DRAIN
(SEE
NOTE 7)

ADDITION FLEX
(SEE NOTE 4)
ADDITION FLEX
(SEE NOTE 4)

NORMAL PROFILE WITH SPRING ISOLATORS LOW PROFILE WITH SPRING ISOLATORS
1
5
LEGEND
GROWTH (CHANGE IN LENGTH) SEE NOTE 1

DIRECTION OF GROWTH
(GROWTH NOT ALLOWED IN OPPOSITE DIRECTION)
SEE
NOTE 9 FIXED (RIGID) PIPE MOUNTS
ROLLER

STRAIGHT ELBOWED FLEX CONN. MUST ACCOMMODATE ALLBETWEEN RIGID


TRANSITION TRANSITION MOUNTS

Page 3 of 4

EN: 112676
Ref.
Exhaust System Installation Guidelines S
DATE: 11/96
8242
GE Energy
Gas Engines Intake/Exhaust Systems

DUAL OUTLET (SIDE VIEW) DUAL OUTLET (TOP VIEW)

SEE NOTE 10
45MAX

SEE NOTE 11

The dual outlets shown below violate the symmetry requirement or have a converging
angle which exceeds 45 potentially causing high or unbalanced restriction.

DUAL OUTLET WITH UNEQUAL DUAL OUTLET INTO HEADER


LENGTH LEGS WITH SIDE DISCHARGE

BRANCH INTO MAIN LINE DUAL OUTLET INTO A TEE

*Trademark of General Electric Company. All other trademarks are the property of their respective owners.

Page 4 of 4