Fiber
There are one RJ-45 Twisted-Pair jack (Auto-MDI/MDI- Cable
FX TX
TX RX LNK/
ACT
FDX/
COL
Broken
TP Fiber TP
Port 2 Port 1
Left View Link Loss Carry Forward (LLCF) If one of the optical conductors is bad (as shown in the
2. Model List OFF ON 100Base-FX diagram
l LED box below),
lit = established link the converter
° LED unlit = no linkwith LLR function will
One DIP switch for Fiber-optic operating mode
Fiber selection,
Network FT-80X incorporates an LLCF function for troubleshooting a
return a no-link condition to its link partner. With LLCF
FDX for full-duplex, and HDX
RX for half-duplex. remote connection. When LFP function is enabled, the FL/TP
Your Fast Ethernet Converter comes with one of the TX function also enabled, the no-link condition is carried
RX ports do not transmit a link signal until they receive a link
following models. forward to the switch/hub where a trap is generated to
TX signal from the opposite port.
5V DC the management station, and the administrator can then
FT-801: on board ST fiber connector determine the source of the loss.
The diagram below shows a typical network configuration
FX Duplex
FT-802/S: on board SC fiber connector with a good link status using FT-80X for remote
Management Switch/Hub Media Media Management
connectivity. Station w/SNMP Converter Converter Switch/Hub Station
FT-803: on board MTRJ fiber connector HDX FDX
+ LFP ON LFP ON
Management Switch/Hub Media Media Switch/Hub Management
FT-806A20: on board single SC fiber connector Station
Management w/SNMP
Switch/Hub Converter
Media Converter
Media w/SNMP
Switch/Hub Station
Management Broken
Station w/SNMP Converter Converter w/SNMP Station TP Fiber TP
Port 2 Port 1
FT-806B20: on board single SC fiber connector LFP ON LFP ON
LFP ON LFP ON
Link Loss Carried Forward Link Loss Carried Forward
Fiber
TP TP
Models with last character “S” indicate the fiber-port is with Side View (FT-80X) TP
Cable
Fiber
Cable TP
Link Loss Returned
“Single-Mode” optic fiber connector and followed with a l LED lit = established link ° LED unlit = no link
number indicates the maximum wiring distance. One DIP switch for Link Fault Pass Through (LFP) feature, l LED lit = established link ° LED unlit = no link
l LED lit = established link ° LED unlit = no link
“ON” to turn-on the LLCF and LLR detection. And “OFF” to
In the following sections, the term “FT-80X” indicates the LFP function is turn-on in default. This feature
turn –off this feature. Please refer to the following sections If the connection breaks, FT-80X that link loss forward to
product family above. FX TX can also be turned off via the side DIP-switch.
for more. TX RX LNK/ the switch/hub that generates a trap to the management
ACT If you are familiar with the network installation
FDX/ station. The administrator can then determine the source of and for diagnostic purpose (i.e. check which
COL
the problem. end is broken), you can turn it off and reset
Note
PWR 100 Management Switch/Hub Media Media Switch/Hub Management the converter to make it take effect. Otherwise,
Fast EthernetLFP
Bridge Station
Management w/SNMP
Switch/Hub Converter
Media Converter
Media w/SNMP
Switch/Hub Station
Management
please remains it in the default position.
Station w/SNMP Converter Converter w/SNMP Station
10/100Base-TX to 100Base-FX
LFP ON LFP ON
LFP ON LFP ON
OFF ON Broken
TP Fiber
Broken TP
TP Cable
Fiber TP
Cable
DIP Switch for LFP function. l LED lit = established link ° LED unlit = no link
l LED lit = established link ° LED unlit = no link
5V DC
10/100Base-TX *Units are shipped with the LFP function enabled (ON).
Cat.5/5e TP FX Duplex
Cable Network
FT-80X
+ HDX FDX
-2- -4- -6- -8-
100Base-FX
Fiber Network
+ HDX FDX
-9- - 11 -
7. Duplex Mode Setting 9. Cable Connection Parameter 10. FT-80X Technical Specifications 11. Power Information
The TP port of FT-80X supports duplex mode detection by The limitations are as below: The FT-80X comes with the following standard features: The power jack of FT-80X is with 2.5mm in the central post
auto-negotiation (A-N). The following is the duplex mode • Standard: IEEE 802.3/u, 10/100Base-TX and 100Base- and required +5VDC power input. It will conform to the
parameters: Duplex Connection Limitation (max.) FX bundled AC-DC adapter and Planet’s Media Chassis. Should
Twisted Pair you have the problem to make the power connection,
• Connectors:
FT-80X Duplex please contact your local sales representative.
Fast Ethernet Device Node to Node One RJ-45 (Auto-MDI/MDI-X) Twisted Pair, EIA568
Mode support Half / Full 100 meters
Node to Switch/Hub Please keep the AC-DC adapter as spare parts when your
Ethernet / Fast Ethernet Hub Half-Duplex One Fiber-optic, 1310nm wavelength (except: FT-806A/
Multi-Mode Converters FT-80X is installed to a Media Chassis.
FT-806B), connector-type vary with model
Ethernet / Fast Ethernet Switch
Half-Duplex Node to Node • Data Transfer Rate: 10/100Mbps (TP), 100Mbps (FX)
(without A-N) MM Half 412 meters
Node to Switch
Fast Ethernet Devices * Full-Duplex / • Duplex mode support: Full or half-duplex mode by
Node to Node Auto-Negotiation (TP)
Support Auto-Negotiation Half-Duplex MM Full 2 kilometers
Node to Switch
• LED indicators: PWR, FX LNK/ACT, FX FDX/COL TP 100,
Single-Mode Converters* TP LNK/ACT, TP FDX/COL
Normally, an A-N switch will detect and set to
(FT-80xynn; x= 2, 6; y= S, A, B; nn=km) • Power Requirement: 5V DC, 2A
full-duplex, where a dual-speed hub will detects Energy Saving Note of the Device
Note half. Node to Node • Ambient Temperature: 0° to 50°C (operating)
SM Full Depends on model This power required device does not support Standby mode
Node to Switch
• Humidity: 5% to 90% (non-condensing) operation.
There is a DIP-switch as in the left view as section 4. Please
check and follow the duplex mode of the fiber device and 1. Consult your local dealer for more about our • Dimension: 26 x 70 x 97mm (H x W x D)
For energy saving, please remove the DC-plug or push the
have the duplex selection to your FT-80X. single mode fiber connectivity. • Cable: hardware Power Switch to OFF position to disconnect the
2. A model (TX: 1310nm; RX: 1510nm) and B UTP: Cat 5 UTP cable device from the power circuit.
Note model (TX: 1510nm; RX: 1310nm) should
Fiber: MM: 50/125µm or 62.5/125µm optic fiber Without remove the DC-plug or switch off the device, the
runs in pair.
Fiber: SM: 8.3/125, 8.7/125, 9/125µm optic fiber device will still consume power from the power source. In
the view of Saving the Energy and reduce the unnecessary
Connecting to Router, Bridge, or Switch, Hub, please refer power consuming, it is strongly suggested to power off
to the device’s Technical Manual. or remove the DC-plug for the device if this device is not
intended to be active.