Professional Documents
Culture Documents
units
Inputs Calculations
Qr = Qo(X - Xo)/(Xw - X)
Qw = (8.34*V*X)/(8.34*SRT*Xw)
VMG = V*7.48/1,000,000
F:M = (8.34*So*Qo)/(8.34*%Vol*X*VMG)
Unit Conversion Note:
(8.34)(mg/L)(MGD) = lb/day
Activated Sludge Waste Water Treatment Calculations - S.I. units
Inputs Calculations
Qr = Qo(X - Xo)/(Xw - X)
Qw = (V*X)/(SRT*Xw)
F:M = (So*Qo)/(%Vol*X*VMG)