ARNU543NKA4
Multi V™ Vertical /Horizontal Air Handling Unit
54,000 Btu/h Indoor Unit
Performance: Entering Mixed Air:
Cooling Mode: Cooling Max⁴  (°F WB) 76
Total Cooling  Capacity (Btu/h) 54,000 Heating Min (°F DB) 59
Heating Capacity (Btu/h) 60,000 Unit Data:
Power Input¹  (W) 366 Refrigerant Type R410A
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:
Refrigerant Control EEV
Indoor: 80°F DB /67°F WB Indoor: 70°F DB / 59° WB
Outdoor 95°F DB / 75°F WB Outdoor 47°F DB / 43°F WB Sound Pressure⁵ dB(A) (H/M/L) 50/49/47
: :
Electrical  :
² Net Unit Weight (lbs)  165
Power Supply  (V/Hz/Ø) 208‐230/60/1 Shipping Weight (lbs) 181
Rated Amps (A)  1.80 Fan:
Piping: Type Sirocco
Refrigerant: Fan Quantity: 1
Liquid Line (in, OD) 3/8 braze Motor/Drive: Brushless Digitally Controlled/Direct
Vapor Line (in, OD) 5/8 braze Motor Quantity: 1
Condensate: High Mode Airflow Rate H/M/L (CFM): 1,475/1,400/1,260
Condensate Line (in, ID) 1 High Mode External Static Pressure (ESP)⁶ (in wg): 0.5
Factory Installed Pump No Standard Mode Airflow Rate H/M/L (CFM): 1,475/1,400/1,260

Controls Features: Standard Mode External Static Pressure (ESP)⁶  (in wg): 0.3


•Auto Opera on •Hot Start Minimum ESP (in wg)⁷: 0.1
•Auto Changeover (Heat •Self Diagnos cs
Maximum ESP (in wg)⁷: 1.0
Recovery Only) •Weekly Schedule
•Auto Restart •Dual Setpoint Control
•Child Lock •Filter Life and Power Consumption Standard Features:
•Dual Thermistor Control Display •Access Panel for Field Supplied Air Filter
•E.S.P. Control •External on/off control •(20 x 24 x 1)
•Group Control •Timer (On/Off) Notes:
•Fan Speed Control 1.The Power Input is rated at high speed.
Optional Accessories: 2.Electrical data listed is without an electric heat kit accessory op on. The 
Wireless Remote Controller³ ‐ PQWRHQ0FDB addition of an electric heat kit accessory option will change the electrical data.
3. Requires an LG wall controller because ducted units don't have an infrared 
LG Programmable Controller ‐ PREMTB10U receiver.
4.See Engineering Manual for sensible and latent capaci es.
LG Premium Controller ‐ PREMTA000 5.Sound pressure levels are tested in an anechoic chamber under ISO
Standard 3745.
Simple Controller with Mode (Black) ‐ PQRCVCL0Q 6. At factory fan speed setting.
Simple Controller with Mode (White) ‐ PQRCVCL0QW 7. Maximum static pressure may result in reduced airflow (CFM).
8.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, 
Simple Controller without Mode (Black) PQRCHCA0Q shielded and must comply with applicable local and national code.
9.Power wiring cable size must comply with the applicable local and na onal
Simple Controller without Mode (White) ‐ PQRCHCA0QW code.
Simple Dry Contact (1 contact, 24 VAC external power) ‐ PDRYCB100 10.Adjust fan speed to correct for sta c pressure increases when using field 
supplied air filter or heat kit.
Dry Contact for Economizer ‐ PQDSBC1 11.Must follow installa on instruc ons in the applicable LG installa on manual.
Dry Contact for Third Party Thermostat ‐ PDRYCB300
Wall Mounted Temperature Sensor ‐ PQRSTA0

For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. / www.lghvac.com SB_MultiV_VAHU_ARNU543NKA4_1_16 Page 1 of 2
Job Name/Location:
ARNU543NKA4 Tag #:
Multi V™ Vertical /Horizontal Air Handling Unit Date:
54,000 Btu/h Indoor Unit PO No.:

For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. / www.lghvac.com SB_MultiV_VAHU_ARNU543NKA4_1_16 Page 2 of 2