You are on page 1of 2

Job 

Name/Location: Tag #:
Date: For: File Resubmit
PO No.: Approval Other
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)

ARNU09GTRB4
Multi V™ 4‐Way Ceiling Cassette
9,600 Btu/h Indoor Unit
Performance: Entering Mixed Air:
Total Cooling Capacity (Btu/h) 9,600 Cooling Max³ (°F WB) 76
Heating Capacity (Btu/h) 10,900 Heating Min (°F DB) 59
Power Input¹ (W) 30
Unit Data:
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:
Indoor: 80°F DB/67°F WB Indoor: 70°F DB Refrigerant Type R410A
Outdoor 95°F DB Outdoor 47°F DB/43°F WB
: : Refrigerant Control EEV
Electrical:
Sound Pressure⁴ dB(A) (H/M/L) 30/29/27
Power Supply (V/Hz/Ø) 220‐230/60/1
Rated Amps (A) 0.2 Primary Filter Type Washable
Secondary Filter Type⁵ Basic
Piping:
Net Weight (lbs) 32
Refrigerant:
Shipping Weight (lbs) 38
Liquid Line (in, OD) 1/4 Flare
Grille Weight (lbs) 7
Vapor Line (in, OD) 1/2 Flare
Grille Shipping Weight (lbs) 11
Condensate:
Condensate Line (in, OD) 1
Factory Installed Pump² Yes Fan:
Type Turbo
Controls Features:
•Auto changeover •Hot start Quantity 1
  (Heat Recovery Only) •Self diagnos cs Motor/Drive Brushless Digitally Controlled/Direct
•Auto opera on •Timer (on/off)
•Auto restart •Weekly schedule Motor Quantity 1
•Child lock •Auto direc on/swing (up/down) Airflow Rate H/M/L (CFM) 283/265/251
•Dual thermistor control •Fan speed control
•Dual setpoint control •Multiple aux heater applications
Notes:
1.The Power Input is rated at high speed.
•Group control •Swirl wind (alterna ng vanes) 2.Maximum li  is 27 in from bo. om of unit.
3.See Engineering Manual for sensible and latent capaci es.
•High ceiling •Jet cool (fast cooling) 4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
Required Accessories: •Filter life and power consumption display 5.Plasma f lter kit accessory available separately.
6.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must 
Grille Kit (PT‐UQC or PT‐QCHW0) comply with applicable local and national code.
7.Power wiring cable size must comply with the applicable local and na onal code.
Optional Accessories: 8.This unit comes with a dry nitrogen charge.
9.This data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and a 0   
Wireless Remote Controller ‐ PQWRHQ0FDB level difference between outdoor and indoor units.  All capacities are net with a combination ratio 
between 95 – 105%.
LG Programmable Controller ‐ PREMTB10U 10.Must follow installa on instruc ons in the applicable LG installa on manual
LG Premium Controller ‐ PREMTA000
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
Simple Dry Contact (1 contact, 24 VAC external power) ‐ PQDSB1
Dry Contact for Economizer ‐ PQDSBC1
Dry Contact for Third Party Thermostat ‐ PQDSBNGCM1
Wall Mounted Temperature Sensor ‐ PQRSTA0
Ventilation Kits ‐ PTVK430
Plasma Filter Kit ‐ PTPKQ0
LG Electronics Perú S.A. www.lg.com.pe / www.lgaircon.com
© LG Electronics PERÚ S.A., Av. República de Colombia 791 Piso 12 San Isidro / Lima - Perú SB_MultiVIV_4WayCeilingCass_ARNU09GTRB4_05_20 Page 1 of 2
Job Name/Location:

ARNU09GTRB4 Tag #:
Multi V™ 4‐Way Ceiling Cassette Date:
9,600 Btu/h Indoor Unit PO No.:

P/No. : TBA35049101
Chassis Code : TR

LG Electronics Perú S.A. www.lg.com.pe / www.lgaircon.com


© LG Electronics PERÚ S.A., Av. República de Colombia 791 Piso 12 San Isidro / Lima - Perú
SB_MultiVIV_4WayCeilingCass_ARNU09GTRB4_05_20 Page 2 of 2

You might also like