You are on page 1of 2

Job Name/Location: Tag #:

Date: For: File Resubmit


PO No.: Approval Other
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)

ARNU243SCL4
Multi V™ Wall Mounted Unit
24,200 Btu/h Indoor Unit
Performance: Unit Data:
Total Cooling Capacity¹ (Btu/h) 24,200 Refrigerant Type R410A
Heating Capacity (Btu/h) 27,300 Refrigerant Control EEV
Power Input² (W) 39.5 Sound Pressure³ dB(A) (H/M/L) 45 / 40 / 35
Cooling Nominal Test Conditions: Heating Nominal Test Conditions:
Indoor: 80°F DB/67°F WB Indoor: 70°F DB Primary Filter Type Washable
Outdoor 95°F DB Outdoor 47°F DB/43°F WB
: : Secondary Filter⁵ Plasma
Electrical:
Net Unit Weight (lbs) 31
Power Supply (V/Hz/Ø) 208‐230/60/1
Shipping Weight (lbs) 37
Rated Amps (A) 0.29

Piping: Fan:
Refrigerant: Type Cross Flow
Liquid Line (in, OD) 3/8 Flare Quantity 1
Vapor Line (in, OD) 5/8 Flare Motor/Drive Brushless Digitally Controlled/Direct

Condensate: Motor Quantity 1


Airflow Rate H/M/L (CFM) 494 / 449 / 406
Condensate Line (in, OD) 1
Notes:
Factory Installed Pump No 1.See Engineering Manual for sensible and latent capaci es.
2.The Power Input is rated at high speed.
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
Controls Features: 4.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must
•Auto changeover •Timer (on/off) comply with applicable local and national code.
5.Plasma filter kit accessory available separately.
(Heat Recovery only) •Weekly schedule 6.Power wiring cable size must comply with the applicable local and na onal code.
•Auto opera on •Auto direc on/swing (up/down) 7.This unit comes with a dry nitrogen charge.
8.This data is rated 0 above sea level, with 25 of refrigerant line per indoor unit and a 0
•Auto clean (coil dry) •Manual Direction (left/right) level difference between outdoor and indoor units. All capacities are net with a combination ratio
•Auto restart •Fan speed control between 95 – 105%.
9.Must follow installa on instruc ons in the applicable LG installa on manual
•Child lock •Jet cool (fast cooling)
•Dual thermistor control •Dual setpoint control
•Group control •Filter life and power
•Hot start consumption displays
•Self diagnos cs

Optional Accessories:
Wireless Remote Controller ‐ PQWRHQ0FDB
LG Programmable Controller ‐ PREMTB10U
LG Premium Controller ‐ PREMTA000
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
Simple Dry Contact (1 contact, 24 VAC external power) ‐ PQDSB1
Dry Contact for Economizer ‐ PQDSBC1
Dry Contact for Third Party Thermostat ‐ PQDSBNGCM1
Plasma Filter Kit ‐ PTPKC0

For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com SB‐MultiVIV_WallMount_Stand‐ARNU243SCL4‐04‐15 Page 1 of 2
Job Name/Location:

ARNU243SCL4 Tag #:
Multi V™ Wall Mounted Unit Date:
24,200 Btu/h Indoor Unit PO No.:

For continual product development, LG reserves the right to change specifications without notice.