~4), Hyderabad Engineering Labs Wks accra Laas ee - 206 «AAS nt Phone : 040-65277870, Telefax : 040-23075850, M : 8885599668 E-mail : sbkhydlabs@gmail.com / hydenglabs@gmail.com . website : www hyderabadlabs.net Da TSS ae Wee oan eT) #5-9-16/10, Prashanthi Nagar, Indl. Estate, Kukatpally, Hyderabad - 500 072. India. i TEST REPORT Customer ".:M/s, J.JKFENNER INDIA LIMITED. Rep.No- .C&M-083+1 IDA, Pashamylaram, Patancheru, Medak-Dist Date OF Test: 10.05.2018 P.O.No&Date: Verbal Dt: 08.05.2018 Specification : 1S:1570 4508 Batch, No- GMC 372/18 Dt: 07.05.2018 ‘Sample Description - FGC & EFGC HUBS Specification minimum requirements: C-0.40-0.50,Mn-0.60-0.90 Si-0.15-0.35,5,P-0.040Max Y.S. <347 N/mm’, U.T.S=630 to 710 N/mm, Elongation=15% Equipment Used : Optical Emission Spectrometer Test Reference _ : IS: 8811-98 SLNo.| Sample Identification | C% | Mn | sis | sx | P% Batch. No- GMC 372/18 o1 Sample Piece aaa | 0.72 | 022 | 0.021 | 0.026 MECHANICAL TESTS: (A) TENSILE TEST Equipment Used: M/C Code-UTN/E-40 SR.No-10/90-1346, Cal.Due on; 09.09.2018 ‘Test Reference: IS: 1608-2005 ‘Sample Size ofTest | Areaof | GiLinamm | Yield Load | Max Toad | Final GI. ] Dia affer _ Identification Pice.mm Test KN KN Fractfre Pice.mm2 - Batch, No- GMC 372/18 | Test Bar 210.00 7857 50.0 82 a2 596 Y YS UTS % N/mm2 N/mm2, Elongation SRA Remarks| 549.82 689.83 192, 5 2 Remarks: The elements tested are within the limits of the above specification Lab Test No.C18-8795 Note: 1) This result pertains to the samples received at our lab. 2) This T.C. cannot be reproduced except in full without our written permission Inspection Agency “Mechanical Testing ® Molallography &Sall Spray ® PMI__