Professional Documents
Culture Documents
Contractor:______________________________Notes:_________________________
COOL
WHITE
5
5000K
DIMMABLE WET RoHS IP65 YEAR
LED LOCATION COMPLIANT RATED WARRANTY
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
Job Name/Title:__________________________Catalog Number_________________
Contractor:______________________________Notes:_________________________
GENERAL SPECIFICATIONS
Input Voltage, Frequency Hz: 120-277V, 50/60Hz MOUNTING HEIGHT & REPLACEMENT
Power Factor: >0.9
THD: <20%
Surge Protection: 4kV 200W
135W 30,000 Lumens
LED: Samsung 2835 90W 20,250 Lumens
Functional Life (L70): 50,000 hours 13,500 Lumens
25'-30'
Beam Angle: 110° 20'-25' Mounting
CRI: >80 15'-20' Mounting Height
CCT: 5000K Mounting Height
Ambient Operating Temperature: -40°F to 122°F Height
ENERGY SAVINGS
Energy
LED Watts Replacement HID Wattage Savings, Watts Yearly Saving, $ 5 Year Savings, $
Based on 12 hours/day and 11¢/kwhr
F-LUHB/90W/50K 90 175-250W 160 $77.08 $385.44
F-LUHB/135W/50K 135 400W 265 $127.67 $638.38
F-LUHB/200W/50K 200 400-600W 400 $192.72 $963.60
NOMENCLATURE
Example: F-LUHB/90W/50K
F = Fixture / LUHB = LED UFO High Bay / 90W = 90 Watts / 50K = 5000K
135W = 135 Watts
200W = 200 Watts
DIMENSIONS
90W 135W 200W
8.67“ 8.63“
6.08“
5.20“ 7.69” 6.12“
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
TESTING
Job Name/Title:__________________________Catalog Number_________________
Lab Code: 201079-0
Contractor:______________________________Notes:_________________________
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
R
Circle of Light Plot
Beam Width
(across 50% Nadir Illum)
Height(ft) Illuminance at Nadir (fc) 0‐180 90‐270
January 2020
(issuing laboratory) Page 4 of 5
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
TESTING
Job Name/Title:__________________________Catalog Number_________________
Lab Code: 201079-0
Contractor:______________________________Notes:_________________________
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
TESTING
Job Name/Title:__________________________Catalog Number_________________
Lab Code: 201079-0
Contractor:______________________________Notes:_________________________
Test Number: LLIA001077‐002
LED High Bay Fixture - Eclipse Series
Catalog Number: F‐LUHB/135W/50K
Highbay mounted, cast aluminum housing, formed white
enamel steel reflector, clear plastic enclosure.
440 white LEDs, one L2394(D214.5X1.5) 440LED 40C11B LED board
One Sosen SS‐150CN‐130BH LED driver
F-LUHB/135W/50K
120.0Vac, 60.00Hz, 1.082A, 129.6W, 0.998PF, 3.1%THD(i)
Coefficients Of Utilization ‐ Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 110 105 101 98 107 103 99 96 99 96 93 95 92 90 91 89 88 85
2 100 92 86 80 97 90 84 79 87 82 77 83 79 75 80 77 74 72
3 91 81 73 67 89 79 72 66 76 70 65 74 68 64 71 67 63 60
4 83 72 63 56 81 70 62 56 68 61 55 65 59 54 63 58 54 52
5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 45
6 71 57 49 42 69 56 48 42 55 47 42 53 46 41 51 45 41 39
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34
8 61 47 39 33 59 47 39 33 45 38 33 44 37 33 43 37 32 30
9 57 43 35 30 55 43 35 30 42 34 29 41 34 29 40 34 29 27
10 53 40 32 27 52 39 32 27 38 31 27 38 31 27 37 31 26 25
For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic
assumptions: 1) Room surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed
throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance.
Circle of Light Plot
Beam Width
(across 50% Nadir Illum)
Height(ft) Illuminance at Nadir (fc) 0‐180 90‐270
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
TESTING
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.
R
TESTING
Job Name/Title:__________________________Catalog Number_________________
Lab Code: 201079-0
Contractor:______________________________Notes:_________________________
Test Number: LLIA001077‐003
LED High Bay Fixture - Eclipse Series
Catalog Number: F‐LUHB/200W/50K
Highbay mounted, cast aluminum housing, formed white
enamel steel reflector, clear plastic enclosure.
720 white LEDs, one L2397(D277.6X1.5) 720LED 40C18B LED board
One Sosen SS‐200CN‐130BH LED driver
F-LUHB/200W/50K
120.0Vac, 60.00Hz, 1.569A, 188.1W, 0.999PF, 2.8%THD(i)
Coefficients Of Utilization ‐ Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
1 110 105 101 97 107 103 99 96 99 96 93 95 92 90 91 89 87 85
2 100 92 85 80 97 90 84 79 86 81 77 83 79 75 80 77 74 71
3 91 81 73 66 89 79 72 66 76 70 65 73 68 64 71 66 62 60
4 83 71 63 56 81 70 62 56 68 61 55 65 59 54 63 58 54 51
5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44
6 71 57 48 42 69 56 48 42 55 47 42 53 46 41 51 45 41 39
7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34
8 61 47 39 33 59 47 39 33 45 38 33 44 37 32 43 37 32 30
9 57 43 35 30 55 43 35 30 42 34 29 41 34 29 40 33 29 27
10 53 40 32 27 52 39 32 27 38 31 27 37 31 26 37 31 26 25
For absolute test reports, CUs are expressed as a percentage of total lumen output. Calculations were based on published IES procedures, and are based on the zonal cavity method. Basic
assumptions: 1) Room surfaces are lambertian reflectors. 2) Incident flux on each surface is uniformly distributed. 3) The room is spectrally neutral. When luminaires are not evenly distributed
throughout the room, or do not exhibit lateral symmetry, CU values may differ from actual performance.
Circle of Light Plot
Beam Width
(across 50% Nadir Illum)
Height(ft) Illuminance at Nadir (fc) 0‐180 90‐270
New York | California | Florida | www.topaz-usa.com | 800.666.2852 | Fax: 631.654.1261 | ©2018 Topaz Lighting Corp.