You are on page 1of 3

V201 Gauge Panel Communication Error

V202 Ecu Communication Error


V210 Pump P/V
V211 Cooling Fan P/V
V212 Flow Control P/V
V213 Relief Pressure Up
V214 Pilot Relay
V215 Swing Priority S/V
V216 Reverse Fan Speed S/V
V217 Starter Relay
V218 After Heat Relay
V220 Front Pump Press Sensor
V221 Rear Pump Press. Sensor
V222 Hyd. Oil Temperature Sensor
V223 Water Temperature Sensor
V224 Engine Speed Sensor
V225 Fuel Level Sensor
V226 Alternator Potential
V227 Dial
V228 Accel. Pedal
V229 Parking Brake Press. Sensor
V230 E/g Control Motor Sensor
V231 Accel. Pedal SW
E011 Coolant temperature sensor
E012 Fuel temperature sensor
E013 Boost air temperature sensor
E014 Boost air pressure sensor
E017 E/G oil temperature sensor
E018 E/G oil pressure sensor
E021 Battery voltage
E022 Fuel pressure sensor
E032 Fuel pressure monitoring MPROP
E037 CAN-B line
E038 Engine overspeed
E039 Main relay (SCG)
E041 Redundant shutoff path
E042 E/G speed (Crankshaft
E043 E/G speed (Camshaft)
E044 Engine speed sensor
E045 EEPROM
E046 Recovery
E047 Monitoring of PRV
E048 Power supply
E049 Main relay SCB
E051 Main relay ECU
E058 Solenoid power stage 1
E059 Solenoid power stage 2
E061 Solenoid power stage 3
E062 Solenoid power stage 4
E063 Solenoid power stage 5
E064 Solenoid power stage 6
Fuel HI pressure pump (E/G: Current controlled Highside
E065
power stage 1)
E066 Preheat light (E/G:Lowside Power stage 2)
E068 Preheat relay (E/G:Highside Power stage 1)
E091 CAN-A line
E097 Monitoring of misfire cylinder 1
E098 Monitoring of misfire cylinder 2
E099 Monitoring of misfire cylinder 3
E101 Monitoring of misfire cylinder 4
E102 Monitoring of misfire cylinder 5
E103 Monitoring of misfire cylinder 6
E104 Monitoring of misfire multiple cylinder
E105 Monitoring of overrun
E106 Engine speed redundant
FMI FMI 0 Above normal range (DATA VALID but ABOVE
0 NORMAL OPERATIONAL RANGE)
FMI Below normal range (DATA VALID but BELOW
1 NORMAL OPERATIONAL RANGE)
FMI Incorrect signal (DATA ERRATIC, INTERMITTENT OR
2 INCORRECT)
FMI Voltage above normal (VOLTAGE ABOVE NORMAL OR
3 SHORTED TO HIGH SOURCE)
FMI Voltage below normal (VOLTAGE BELOW NORMAL OR
4 SHORTED TO LOW SOURCE)
FMI Current below normal (CURRENT BELOW NORMAL
5 OR OPEN CIRCUIT)
FMI Current above normal (CURRENT ABOVE NORMAL
6 OR GROUNDED CIRCUIT)
FMI Abnormal signal (ABNORMAL FREQUENCY OR
8 PULSE WIDTH OR PERIOD)
FMI Failure mode not identifiable (ROOT CAUSE NOT
11 KNOWN – Malfunction)
FMI
NOT AVAILABLE OR CONDITION EXISTS
31