Industrial Electrical

Hazard Awareness

Glenn Kwabena Gyimah (PhD)


Accra Technical University
Mechanical Engineering Department
What does hazard mean?

Hazard means:
• any potential or actual threat to the wellbeing of people,
machinery or environment

Electrical hazard safety means:


• taking precautions to identify and control electrical hazards

www.dmp.wa.gov.au/ResourcesSafety
Introduction
Definitions:
• Electricity – movement
of the free electrons between
atoms;
– Related terms: Source:

• Current – the movement of


NIOSH

electrical charge
• Resistance – opposition to current flow
• Voltage – a measurement of electrical force

www.dmp.wa.gov.au/ResourcesSafety
Introduction
• Conductors – substances, such as metals, that have
little resistance to electricity
• Insulators – substances, such as dry wood, rubber,
glass and Bakelite, that have high resistance to
electricity
• Grounding – a conductive connection to the earth
which acts as a protective measure

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards

Serious injuries and death can be caused by electrical hazards such as arc flash, shocks, burns, falls, and fires. Source of graphics: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
BE SAFE:
• Burns
• Electrocution
• Shock
• Arc flash/arc blast
• Fire
• Explosions

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Burns:
• Most common shock-related injury
• Three types of electrical burns:
– Electrical
– Arc flash
– Thermal contact

Source:
OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Electrocution:
• Is fatal
• Meaning: to kill with electrical shock
• Results when a human is exposed to a
lethal amount of electrical energy

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Shock:
• Body becomes part
of electrical circuit
• Reflex response to
passage of electric Source:
OSHA
current through the body

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Arc Flash/Arc Blast
• Arc flash
– Sudden release of electrical energy through air
when a high-voltage gap exists and there is a
breakdown between conductors
– Gives off thermal radiation (heat) and bright,
intense light that can cause burns
– Temperatures as high as 35,000°F

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
• Arc blast – high-voltage arcs can also
produce considerable pressure waves
by rapidly heating the air and creating
a blast

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Fire:
• Most result from problems with "fixed
wiring”
• Problems with cords, plugs, receptacles,
and switches also cause electrical fires

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Explosions:
• Occur when electricity ignites explosive
mixture of material in the air
• Note:
– Electricity is source of these hazards
– All hazards are of equal importance
– Lesson focuses on eliminating electrical
hazards

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
Examples of fatal accidents:
• Case #1: Worker electrocuted when the ladder
came in contact with overhead power lines
• Case #2: Worker electrocuted when mast
came in contact with high voltage overhead
lines

www.dmp.wa.gov.au/ResourcesSafety
Electrical Hazards
• Case #3: Worker changing energized ballast
on light fixture was electrocuted and fell to
the concrete floor while working from an 8'
fiberglass stepladder.

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
Contact with overhead power lines:
• Overhead and buried
power lines carry
extremely high voltage
• Risks
– Electrocution (main risk)
– Burns and falls

Source: NIOSH

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Cranes are not the only
equipment that can reach
overhead power lines.
• Use of ladders or suspension
in a man-basket under or near Source:
OSHA

power lines are risks.

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Important: the covering on an overhead
power line is primarily for weather
protection; therefore, workers need to
know that if they touch a power line,
covered or bare, death is probable.
• https://www.osha.gov/dts/vtools/constructi
on/ladder_powerline_fnl_eng_web.html

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
Contact with energized
sources:
• Live parts
– The major hazards
• Electrical shock and burns
• Electrical shock occurs
when the body becomes
part of the electric circuit
Source:
OSHA

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
– Severity and effects of an electrical shock
depend on a number of factors
• Pathway through the body
• Amount of current
• Length of time of the exposure
• Whether skin is wet or dry
– Water
• Great conductor
• Allows current to flow more easily in wet conditions
and through wet skin

www.dmp.wa.gov.au/ResourcesSafety
(1,000 milliamperes = 1 amp; therefore, 15,000 milliamperes = 15 amp circuit)

Chart
Below 1 milliampere
Current
Generally not perceptible
Reaction

1 milliampere Faint tingle


5 milliampere Slight shock felt; not painful but disturbing. Average
individual can let go. Strong involuntary reactions can
lead to other injuries
6-25 milliamperes (women) Painful shock, loss of muscular control
9-30 milliamperes (men) The freezing current or “let-go” range. Individual cannot
let go, but can be thrown away from the circuit if extensor
muscles are stimulated.
50-150 milliampres Extreme pain, respiratory arrest, severe muscular
contractions. Death is possible.
1,000-4,300 milliamperes Rhythmic pumping action of the heart ceases. Muscular
contraction and nerve damage occur; death likely
10,000 milliamperes Cardiac arrest, severe burns; death probable

This table shows the body’s reaction when exposed to various levels of current. Source: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Damaged or bare wires
– Fault current may travel through a body,
causing electrical burns or death, if
• Power supply is not grounded
• Path has been broken
• There are live parts or bare wires
– Extreme conditions and rough treatment can
change electrical equipment from safe to
hazardous

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Defective equipment or tools

These photos show examples of defective equipment/tools. Source of photos: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Improper repairs
– Examples of incidents
• Ballast strap not replaced after repair = Electrocution of
11 year old boy
• Cutting off bleed resistor on capacitor= causes 370-volt
shock
• Removing and leaving off terminal insulator on capacitor
= causes 440-volt shock

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
Improper use:
• Extension and flexible cords
– Care
– Connection
– Capacity

Source: TEEX SH 46F1-


HT06

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
– Capacity affected by
• Size of wire
– 14 gauge = 15 amps
– 12 gauge = 20 amps
• Length of the cord
– UL tag capacity
– In general any cord over
100 ft. requires one size
larger cord
(14 gauge to 12 gauge) Source:
OSHA

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Power strips:
– Can be over loaded
because of multiple
plug arrangement
– Most have overload protection Source: UBATC

but often malfunction causing fire


– Use fixed wiring when possible

www.dmp.wa.gov.au/ResourcesSafety
Types of Electrical Hazards
• Portable heaters and appliances:
– Manufacturer recommendations
not followed
– Do not plug into a power strip!
This causes overloads and fires.

Source of photos: UBATC

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Maintain safe distance from
overhead power lines:
• Staying away
• Following table shows the safe
power line clearance distance
for various line voltages.
• https://youtu.be/Y2MwX738e1Y

Source of graphics: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Voltage Minimum Clearance Distance
(nominal, kV, alternating current) (feet)
Up to 50 10
Over 50 to 200 15
Over 200 to 350 20
Over 350 to 500 25
Over 500 to 750 35
Over 750 to 1000 45
Over 1000 (As established by the power line
owner/operator or registered
professional engineer who is a
qualified person with respect to
electrical transmission and
distribution)
This table shows the minimum clearance distances, in feet, for different power line voltages. Source: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Use ground-fault circuit
interrupters (GFCI):
• Designed to protect people
from electrical shock
• Detects ground faults and
interrupts electric current
• Limits duration of electrical
shock
Source: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Three types of GFCI:
• Receptacle GFCI
• Temporary/portable GFCI
• Circuit Breaker GFCI

These photos show examples of the three types of GFCI. Source of photos: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Inspect portable tools and extension cords:
• Workers need to inspect extension cords prior
to their use for any cuts or abrasion.
• Electric hand tools that are old, damaged, or
misused may have damaged insulation inside.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Use power tools and equipment as
designed:
• Follow tool safety tips to avoid misusing
equipment
• Follow manufacturer’s instructions

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
• Common examples of
misused equipment

Source: TEEX SH 46F1-


HT06

Source of photos: OSHA Source of photos: OSHA

These photos show examples of equipment misuse.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Tool safety tips
• Never carry a tool by the cord.
• Never yank the cord to disconnect it.
• Keep cords away from heat, oil, and
sharp edges.
• Disconnect when not in use and when
changing accessories such as blades
and bits.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
• Avoid accidental starting. Do not hold
fingers on the switch button while carrying
a plugged-in tool.
• Use gloves and appropriate footwear.
• Store in dry a place when not using.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
• Don’t use in wet/damp environments.
• Keep working areas well lit.
• Ensure that cords do not cause a tripping
hazard.
• Remove damaged tools from use.
• Use double-insulated tools.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Follow lockout/tagout (LOTO)
procedures:
• Lockout/tagout
– Essential safety procedure
– Protects workers from injury while
working on or near electrical
circuits and equipment Source:
OSHA

– Prevents contact with operating


equipment parts such as, blades,
gears, shafts, etc.

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
– LOTO prevents the unexpected
release of hazardous gases, fluids, or
solid matter in areas where workers
are present.

Source of photos: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Electrical Protection Methods
Power source identification:
• Mark all breakers accordingly for the circuits
they protect
• Mark all disconnect means accordingly for
the equipment they service
• Identify all voltages with proper labeling

www.dmp.wa.gov.au/ResourcesSafety
Employer Requirements
Employer requirements to protect workers:
• Ensure overhead power line safety
• Isolate electrical parts
• Supply ground-fault circuit interrupters (GFCI)
protection
• Establish and implement an AEGCP
• Ensure power tools are maintained in a safe
condition

www.dmp.wa.gov.au/ResourcesSafety
Employer Requirements
• Ensure proper guarding
• Provide training
• Enforce LOTO safety related work practices
• Ensure proper use of flexible cords and
power strips
• Ensure proper identification of power
sources

www.dmp.wa.gov.au/ResourcesSafety
Why know about it?

Because failing to take the necessary precautions can lead to:


• injury or death
• fire or property damage

www.dmp.wa.gov.au/ResourcesSafety
What are the safety priorities?

Electrical hazards exist in almost every workplace. Common


causes of electrocution are:
• making contact with overhead wires
• undertaking maintenance on live equipment
• working with damaged electrical equipment, such as extension
leads, plugs and sockets
• using equipment affected by rain or water ingress

www.dmp.wa.gov.au/ResourcesSafety
How do you respond to electrical incidents?

If you come across a person receiving an electric shock:


• if possible, disconnect the electrical supply (switch?)
• assess the situation – never put yourself at risk
• take precautions to protect yourself and anyone else in the
vicinity
• apply the first aid principles (e.g. DRSABCD)
• assess the injuries and move the casualty to a safe area if
required
• administer first aid if trained
• seek urgent medical attention

www.dmp.wa.gov.au/ResourcesSafety
Do you want to be a victim?

You could be the victim if you:


• don’t follow proper procedures around electricity
• use electrical equipment improperly
• use faulty electrical equipment

www.dmp.wa.gov.au/ResourcesSafety
What are the types of injuries?

• Burns
• Shocks
• Falls

KEEP SAFE
KNOW HOW TO CONTROL ELECTRICAL HAZARDS

www.dmp.wa.gov.au/ResourcesSafety
What are the levels of effect of current?

AC current (mA) Effect on human body

1 Slight tingling sensation


2-9 Small shock
10-24 Muscles contract causing you to freeze
25-74 Respiratory muscles can become
paralysed; pain; exit burns often visible
75-300 Usually fatal; ventricular fibrillation; entry &
exit wounds visible
>300 Death almost certain; if survive will have
badly burnt organs and probably require
amputations

www.dmp.wa.gov.au/ResourcesSafety
What should you do in an electrical emergency?

For low voltage electricity >50 V AC and 110 V DC


• remove the source of electricity supply
• commence CPR if trained
• call the emergency number on site

For high voltage electricity >1000 V


• call the emergency number for your site
• don’t go near the casualty
• don’t touch the casualty or try to free them with anything

www.dmp.wa.gov.au/ResourcesSafety
Should you report electrical incidents?

• Electricity is invisible – this in itself makes it dangerous


• It has great potential to seriously injure or kill
• The company has a duty of care to its employees and
contractors
• Everyone is exposed to electrical hazards, not just electricians
• Report all electrical shocks and near misses

ALL EMPLOYEES CAN BE EXPOSED TO ELECTRICAL


HAZARDS. THEY SHOULD RECEIVE ELECTRICAL HAZARD
TRAINING AT THE COMMENCEMENT OF THEIR
EMPLOYMENT AND REGULAR REFRESHER TRAINING.

www.dmp.wa.gov.au/ResourcesSafety
Can you protect yourself from electricity?

• Don’t wear metal objects


• Turn power off
• Wear appropriate clothing
• Don’t touch live parts
• Don’t install or repair electrical equipment
• Use qualified personnel
• Clean and dry leads and plugs before use
• Use PPE

www.dmp.wa.gov.au/ResourcesSafety
What are other safety measures?

• Heed warning signs


• Use the right equipment
• Study the operation manual
• Take care of extension leads
• Use only approved extension lamps
• Don’t pull on leads
• Use residual current devices – RCDs
• Use the proper fuses and circuit breakers

www.dmp.wa.gov.au/ResourcesSafety
Regular safety inspections

are a part of YOUR job...


• Electrical equipment should be checked each time
before use for defects
• If not tagged or the tag is out of date then report it and
place it out of service

www.dmp.wa.gov.au/ResourcesSafety
Should you be aware of powerlines?

• Do you know if there are overhead powerlines on your site?


• Do you know where they are located?
• Do you know what the safe work clearance is?
• Strict regulations are laid down to cover any work that may have
to be performed close to overhead powerlines

www.dmp.wa.gov.au/ResourcesSafety
What is a powerline corridor?

MSI Regulation 5.28 defines a powerline corridor as the area under


any overhead powerline that has not been properly isolated, and 10
metres either side of the powerline.
• It is essential that these areas are respected. They are there for
the safety of everyone
• Do not store equipment, machinery, buildings
or structures in powerline corridors
• Do not construct, fabricate or maintain
structures, buildings, machinery or
equipment in powerline corridors

LOOK UP AND LIVE

www.dmp.wa.gov.au/ResourcesSafety
Can a powerline be approached safely?

Up to and including to 33 kV
• 2.3 m when passing underneath and 3 m when passing to the side

Above 33 kV
• 4 m when passing underneath and 6 m when passing to the side

www.dmp.wa.gov.au/ResourcesSafety
Who can access substations?

• Only trained and authorised personnel may enter and work


inside a substation
• To enter a substation you must complete the substation entry
training
• Access is restricted for any cabinet with exposed energized parts

ALL ELECTRICAL WORK MUST TO BE RECORDED AND


ENTERED INTO THE ELECTRICAL MINES RECORD BOOK,
AND THE ELECTRICAL SUPERVISOR INFORMED

www.dmp.wa.gov.au/ResourcesSafety
What are electric shock hazards?

• Arc welding can and has killed people in high risk environments
• Everyone involved needs to better understand the hazards,
adopt sound practice and use appropriate safety devices
• Study and adhere to the Code of Practice: WTIA Tech Note 7-04
• Use safety devices such as manual trigger switches and voltage
reducing devices (VRDs)
• Under adverse conditions, strive to improve control measures
(e.g. presence of moisture as sweat or rain)

www.dmp.wa.gov.au/ResourcesSafety
A welding incident…

• Assistant hands welder a metal object.


Resultant current is 35 mA

I = V/R = 67/1900 = 35 mA
Result = Assistant survived but welder died

www.dmp.wa.gov.au/ResourcesSafety
Do you have permission to dig?

Be aware of the potential hazard from buried electrical cables for


the following activities:
• excavation
• drilling
• trenching
• levelling
• digging
• driving of stakes or pegs

Do not commence excavation work near buried cables unless a


permit has been issued by an authorised person
Do you know what precautionary measures need to be taken?

www.dmp.wa.gov.au/ResourcesSafety
What risk assessment?!

www.dmp.wa.gov.au/ResourcesSafety
Is this a problem?

www.dmp.wa.gov.au/ResourcesSafety
What’s Wrong?

Identify the hazards in these photos. Source of photos: TEEX SH 46F1-


HT06

www.dmp.wa.gov.au/ResourcesSafety
What’s Wrong?

Identify the hazards in these photos. Source of photos: OSHA

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
1. What is electricity?
a. The movement of atoms within an object
b. The movement of free electrons between
atoms
c. Solid mass
d. Movement within the nucleus of an atom

Answer: b. The movement of free


electrons between atoms

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
2. “Electrocution” means ___.
a. received a mild electrical shock
b. killed by electrical shock
c. exposed to electrical current
d. any accident involving electricity

Answer: b. killed by
electrical shock R.I.
P.

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
3. Arc flash/arc blast can reach
maximum temperatures up to 350˚F?
a. True
b. False

Answer: b. False - temperatures


can reach up to 3,500˚F

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
4. Which gauge of wire will carry the
most current?
a. 14 gauge
b. 12 gauge
c. 10 gauge
d. 00 gauge

Answer: d. 00 gauge – the lower the


wire gauge number, the
more current it can carry

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
5. What does GFCI stand for?
a. Ground Flexible Conduit Insulator
b. Ground Flow Current Interceptor
c. Ground Fault Circuit Interrupter
d. Ground Floor Connection Intersector

Answer: c. Ground Fault Circuit


Interrupter

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
6. Which of the following is a safe practice?
a. Carrying power tool by the cord
b. Holding fingers on switch button while
carrying a plugged-in tool
c. Keeping cords away from heat, oil, and
sharp edges
d. Yanking cord to disconnect plug from outlet
Answer: c. Keeping cords away from
heat, oil, and sharp edges

www.dmp.wa.gov.au/ResourcesSafety
Knowledge Check
7. Who is responsible for ensuring that
overhead power lines are de-energized?
a. Power company
b. Employer
c. Employee
d. Municipality

Answer: b. Employer

www.dmp.wa.gov.au/ResourcesSafety
The key messages are…

• The risk of electric shock from correctly installed and maintained


power sources is negligible, provided that sensible precautions
are taken by the operator and correct work procedures are
followed
• Ensure that the right person is carrying out electrical work –
licensed versus competent
• Electricity is essential but, improperly used, it can be DEADLY!

To STAY ALIVE, you have to STAY ALERT