You are on page 1of 1

1 2 3 4 5 6

GENERAL KEY PLAN: N

QIBLA

PANTRY/STORAGE UPS ROOM


0.50
FFL
PANTRY/STORAGE UPS ROOM
0.50
FFL 0.50
CLEAN AGENT ADA TOILET FFL
0.50
0.50
FFL
CLEAN AGENT FFL
EMDB ROOM
ADA TOILET 0.50
0.45
FFL EMDB ROOM 0.50
FFL
0.45 FFL
FFL 0.50
FFL
CLEAN AGENT

CLEAN AGENT
0.50
ICT/SCADA ROOM CONTROL ROOM ELECTRICAL ROOM FFL
0.50 0.50 0.50
ICT/SCADA ROOM CONTROL ROOM ELECTRICAL ROOM 0.50 ELECTRICAL
FFL 0.50
FFL FFL FFL SUBSTATION
0.50 0.50 0.50 ELECTRICAL FFL
0.50
FFL FFL FFL SUBSTATION
CHLORINATION ROOM
FFL

CHLORINATION ROOM

0.50
FFL

0.50
FFL

PUMP ROOM
UP UP

PUMP ROOM UP
UP UP UP

UP UP
-1.20
-1.20 -1.20 -1.25 -1.25 -1.75
FFL
FFL FFL FFL FFL
FFL
-1.20 -1.20 -1.25 -1.75
-1.20 -1.25
FFL
FFL FFL FFL FFL FFL

-1.75 -2.15 -1.30


-1.75
FFL FFL FFL
-1.30 FFL
-1.75 -2.15
-1.75
FFL FFL FFL
FFL

PROVISION FOR

PROVISION FOR

PROVISION FOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR
GENERATOR

GENERATOR

GENERATOR

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA
2000 kVA

2000 kVA

2000 kVA

DN

MRMU-4
G00M4

DN
CLEAN AGENT

TOILET

CONTROL ROOM
SCADA ROOM

MRMU-3

G00M3

DN
DN
PROVISION FOR
0.4/33kV

MRMU-2
0.4/33kV

G00M2
STEP-UP TRANSFORMER
(TYPICAL)
(TYPICAL)

DN
MVSG ROOM

MRMU-1
G00M1

DN
E
0.4/33kV

(TYPICAL)
TRX ROOM TOOL STORAGE

LV ROOM

DN

CLEAN AGENT

PROVISION FOR

PROVISION FOR

PROVISION FOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR
GENERATOR

GENERATOR

GENERATOR

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA
2000 kVA

2000 kVA

2000 kVA
PROVISIONAL GLASS LINED STEEL TANK
PROPOSED GLASS LINED STEEL TANK PROPOSED GLASS LINED STEEL TANK FOR MAINLAND FUTURE DEVELOPMENTS
WATER TANK 10,400 m3 WATER TANK 10,400 m 3 G02
G04b

DIAMETER = 44m DIAMETER = 44m G04a

G03

HEIGHT = 7.50m HEIGHT = 7.50m


G01AG01
G00T1 G00P1

DN

DN
SLOPE 1:10

+0.00 F.G.L

CONCRETE
BARRIER
UP GATEHOUSE

QIBLA

NOTES:
1. All dimensions are in meters unless otherwise specified.
2. For setting out plan, refer to DWG
11-150000-0000100120-DAH-TRN-DRG-102001

E= 671233.000 CHAIN LINK FENCE (OR CHAIN LINK SWING ACCESS DOOR): E= 671556.000
N= 3106297.000 G.S POSTS WITH PLASTIC COATED CHAIN LINKS FACIA. N= 3106297.000

GATE 2

D FUEL TANK CHAMBERS


PANTRY/STORAGE
G01
EMDB ROOM
G00P5
CLEAR HEIGHT OF CHAMBERS: 5m
0.45
FFL SURROUNDING OF TANKS: SAND FILLED
PANTRY/STORAGE UPS ROOM
0.45 0.50
FFL
CLEAN AGENT FFL
UPS ROOM GENERATOR PAD 0.20
G00M3 G00P6 FFL
0.50
CLEAN AGENT ADA TOILET FFL
0.50
ADA TOILET FFL EMDB ROOM
0.45
G02 FFL 0.45
FFL 0.50
FFL
0.45
FFL
0.45 FUEL TANK PAD
FFL

CLEAN AGENT
2.30
-4.10
FFL FFL
CLEAN AGENT 0.50
ICT/SCADA ROOM CONTROL ROOM ELECTRICAL ROOM
FFL
0.45 G00M4 0.50 0.50 0.50 ELECTRICAL
FFL ICT/SCADA ROOM CONTROL ROOM ELECTRICAL FFL FFL FFL SUBSTATION
ELECTRICAL ROOM 0.50
SUBSTATION
G00P1 0.50 G00P2 G00P3 FFL
CHLORINATION ROOM FFL 0.45 G00P4
0.45 0.45 CHLORINATION ROOM
FFL
G00M2 FFL FFL
0.45
FFL

0.50
FFL
0.45 PUMP ROOM
0.50
FFL
FFL G00M1

CHLORINATION ROOM
G00M2

PUMP ROOM
UP UP
0.50
PUMP ROOM
FFL UP UP
UP
G00M1
UP UP
-1.20 -1.20 -1.25 -1.75
-1.20 -1.25
-1.95 -1.90 FFL
0.45 FFL FFL FFL FFL FFL
-1.73 FFL FFL
-1.73 -1.73 FFL
FFL FFL FFL

-0.35
FFL

GENERATORS
-1.75 -2.15 -1.30
-1.75 FFL FFL FFL
-1.85
-1.95 FFL
FFL -2.15
FFL FFL

SURGE VESSELS

PROVISION FOR

PROVISION FOR

PROVISION FOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR
2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA
GENERATOR

GENERATOR

GENERATOR
2000 kVA

2000 kVA

2000 kVA

DN

DN
DN
DN
PROVISION FOR
0.4/33kV
STEP-UP TRANSFORMER 0.4/33kV
(TYPICAL) (TYPICAL)

DN
DN
0.4/33kV

(TYPICAL)

DN

PROVISION FOR

PROVISION FOR

PROVISION FOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR

GENERATOR
C

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA

2000 kVA
GENERATOR

GENERATOR

GENERATOR
2000 kVA

2000 kVA

2000 kVA
PROVISIONAL GLASS LINED STEEL TANK
PROPOSED GLASS LINED STEEL TANK PROPOSED GLASS LINED STEEL TANK FOR MAINLAND FUTURE DEVELOPMENTS
WATER TANK 10,400 m3 WATER TANK 10,400 m 3 GENERATOR
DIAMETER = 44m DIAMETER = 44m
HEIGHT = 7.50m HEIGHT = 7.50m DN

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF NEOM. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT FROM NEOM.
P:\S19046-0136D\0-Z00-00-CMN\WIP\TR\AutoCAD\Model\Sindalah Utilities\Detailed Design\Package 2\Sheets\11-150000-0000100120-DAH-TRN-DRG-702001_A.dwg

E= 671556.000
E= 671233.000 N= 3106162.000
N= 3106162.000
A 03C - Detailed Design OR 18.04.22
REV DESCRIPTION APP DATE
PURPOSE OF ISSUE:
FOR APPROVAL
CLIENT: PROJECT MANAGEMENT CONSULTANT:

DESIGN CONSULTANT NAME & LOGO (s): CONTRACTOR NAME & LOGO (s):

DESIGN CONSULTANT / CONTRACTOR: NEOM'S REVIEW:


DRAWN: YA 18.04.22
CHECKED: YA 18.04.22 CHECKED:
APPROVED: OR 18.04.22 APPROVED:

SCALE: 1:500 SHEET SIZE: A0


DISCIPLINE NAME:
Transportation

0000100120/94
Alignment Setting Out Tables
PROJECT NAME:
0000100120/94
A IFC Design Services for Sindalah Utilities
11 - Regional Infrastructure
NEOM
KINGDOM OF SAUDI ARABIA
REGION ASSET CODE CONTRACT CODE
14/04/2022 5:18:40 PM

11 150000 0000100120
DRAWING NUMBER
ORIGINATOR DISCIPLINE DOCUMENT TYPE SEQUENTIAL NUMBER REV NO.

DAHTRN DRG 702001 A


NEOM-NEN-PRC-010_TMP01_01.00