You are on page 1of 3

Wood Shearwall Selector: Solutions Report

Report Generated: April 20, 2022 Software Version: 1.4.0

Design Criteria
General Input Parameters
Design Code 2021 IBC Lumber Species HF
Design Method Segmented Stud Spacing 16 in OC
Seismic Design Category D Sheathing Material Sheathing
Seismic Drift Limit 0.025 hx Sheathing Type Plywood
Wind Drift Limit hx / 180 Minimum Sheathing Thickness 7/16"
Seismic SDS Value 1 Holdown Type Post-Installed
Importance Factor, I 1
Redundancy Factor 1 Applied Lateral Loads (ASD)
Applied Lateral Wind Load 5000 lb

Wall Geometry Applied Lateral Seismic Load 4000 lb


Wall ID
Wall Height 144 in
Wall Length 60 in
Wall Thickness 8 in
Wall Weight 10 psf
Aspect Ratio 2.4

Demand Loads (ASD)


Wind Load Combinations Seismic Load Combinations
Maximum Holdown Tension 14329 lb Maximum Holdown Tension 11469 lb
Maximum Post Compression 14809 lb Maximum Post Compression 11949 lb
Maximum Panel Shear 1000 plf Maximum Panel Shear 800 plf

www.strongtie.com/sbsd Page 1 of 3
Wood Shearwall Selector: Solutions Report
Report Generated: April 20, 2022 Software Version: 1.4.0

Material Summary

Sheathing Nailing 5 Holdown 6 Endpost

Edge / Minimum
Sheathing Sheathing Number Type Holdown Wood
Thickness Field Fasteners End Studs Lumber
Material Type Of Sides And Size Model Species
Spacing Grade

5-1" Machine
Sheathing Plywood 7/16" 2 8d 2/12 HD19 6x8 HF No1
Bolt

Design Summary

Allowable Post Post


Loading HD Capacity Panel Shear Compression Compression Post Net Section Holdown
vASD
Type (lb) DCR Parallel To Grain Perpendicular Tension DCR Tension DCR
(plf) DCR To Grain DCR

Wind 1387 16210 0.721 0.43 0.886 0.623 0.884

Seismic 992 16210 0.806 0.347 0.715 0.498 0.708

Shearwall Deflection Summary1,2,3

Deflection Due
Panel Shear Total Wall
Loading Bending Term To Vertical Shearwall Drift Allowable Drift Drift
And Nail Slip Horizontal
Type (in) Components (in) (in) DCR
Term (in) Deflection (in)
(in)

Wind 0.052 0.286 0.451 0.788 0.788 0.800 0.985

Seismic 0.059 0.327 0.515 0.901 3.603 3.600 1.001

Shear Anchorage7
Sill Plate Material MASA Solution 4

Wood Species HF Minimum Number of MASA 4


Minimum Lumber Grade No1 Side Fasteners 3-10dx1-1/2
Sill Size 2x Top Fasteners 6-10dx1-1/2

Anchor Bolt Solution Alternative Titen HD Solution


Diameter (6) - 1/2" Diameter Model Number (6) - THD50600H

www.strongtie.com/sbsd Page 2 of 3
Wood Shearwall Selector: Solutions Report
Report Generated: April 20, 2022 Software Version: 1.4.0

Notes:
1. Drift values are calculated based on the ANSI/AWC SDPWS - 2021 three term equation. Simpson Strong-Tie Holdown Δa values were used for the
calculation. If other holdown types are used, these drift values are not valid.
2. Drift values noted are based on blocked wood structural panel walls.
3. Stiffness values, Ga, used are based on framing members with moisture content of 19% or less.
4. MASA values based on standard installation based on Simpson Strong-Tie catalog C-C-2021. Designer to adjust number of MASA as required for
other installation methods.
5. Holdown anchorage shall be specified by the designer.
6. Shear anchorage solutions (anchor bolt, MASA, and Titen HD) only consider the effects of in-plane loading. All other loading shall be evaluated by the
designer.
7. For 2015, 2018 and 2021 IBC, nominal shear capacity of all wood structural panel shearwalls with aspect ratio (h/b) greater than 2:1 has been
multiplied by 2b/h for design. This was applied to both Wind and Seismic Loads.

www.strongtie.com/sbsd Page 3 of 3

You might also like