You are on page 1of 15

MIM 350

Final Submission

Team Members: AYÇA ÇALIŞIR, BİLGE NUR ÇALIŞKAN, SELEN TURFAN


SAB Kindergarten
Locations and Climates:

Ottawa,Canada Continental Climate


Belo Horizonte,Brazil-Tropical Climate Place one image of the building
Cairo,Egypt-Steppe Climate that you designed together as a
group
SAB Kindergarten

Elevation

EAST ELEVATİON

Model View Plan

EAST ELEVATİON

GROUND FLOOR PLAN WEST ELEVATİON

Elevation

SOUTH ELEVATİON

Site Plan Plan

Elevation

SITE PLAN BASEMENT FLOOR PLAN NORTH ELEVATİON


Ottawa,Canada-Continental Climate I Ayça Çalışır
Area (975m2):

Elevation

EAST ELEVATİON
Model View Plan

Elevation

GROUND FLOOR PLAN


WEST ELEVATİON

Elevation

SOUTH ELEVATİON
Site Plan Plan

Elevation
SİTE PLAN NORTH ELEVATİON
BASEMENT FLOOR PLAN
Belo Horizonte,Brazil-Tropical Climate I Bilge Nur Çalışkan
Area (975m2):

Elevatin

EAST ELEVATİON

Model View Plan

Elevation

WEST ELEVATİON
GROUND FLOOR PLAN

Elevation

SOUTH ELEVATİON

Site Plan Plan

Elevation

SİTE PLAN BASEMENT FLOOR PLAN NORTH ELEVATİON


Cairo,Egypt-Desert Climate| Selen Turfan
Area (974,5m2):

Elevation

EAST ELEVATİON
Model View Plan

WEST ELEVATİON
GROUND FLOOR PLAN

SOUTH ELEVATİON

Site Plan Plan

Elevation
NORTH ELEVATİON
BASEMENT FLOOR PLAN
Simulation Period: Summer Solstice
Belo Horizonte-Tropical Climate
Comparison Ottawa-Continental Climate Cairo,Egypt-Desert Climate

Building orientation
180°Clockwise
No Rotation No Rotation

South Orientation -North Orientation North Orientation


As a result of the analyzes, the orientation towards
As a result of the analyzes, the orientation towards As a result of the analyzes, the orientation
the north is more accurate in the direction of
the south is more accurate in the direction of towards the north is more accurate in the
energy use.
energy use. direction of energy use.

-Material -Material Change -Material Change


Design interventions concrete From Concrete to Stone From concrete to brick
-Inner Court
to make more use of daylight -Inner court with
-Larger windows
sun breakers

-Triple Glazed -Sun breakers -Sun shades


Windows for -Gap Opening panel on south
Insulation
The entrance hall is planned façade
as an indoor space. As a
-Roof Slope %33 result of the analysis, it -Elongated roof
turned into a semi-open
space.
eaves
Belo Horizonte-Tropical Climate
Comparison Ottawa-Continental Climate Cairo,Egypt-Desert Climate
21 December/Southern Hemisphere 21 June/Northern Hemisphere
Solar exposure study 21 June/Northern Hemisphere

North Façade East Façade North Façade East Façade


North Façade East Façade North Façade East Façade

North East East


Façade Façade Façade

BEFORE South Façade


South Façade
West Façade
West Façade South Façade West Façade South Façade West Façade

South West South West


Façade Façade Façade Façade

North Façade East Façade North Façade East Façade East Façade
North Façade

North East North East


Façade Façade Façade Façade
AFTER
South Façade West Façade South Façade West Façade South Façade West Façade

South West South West


Façade Façade Façade Façade

Climate-related ● East façade are exposed to a ● East façade are exposed to a ● South façade are exposed to
high amount of solar, high amount of solar, a high amount of solar,
design strategies therefore I add large windows therefore I add sun brakers. therefore I add sun shade
to utilize daylight as much as ● Sun intensity changed panels and I reduce the size
possible. window sizes of windows.
Comparison Ottawa-Continental Climate Belo Horizonte-Tropical Climate Cairo,Egypt-Desert Climate
21 December/Southern Hemisphere 21 June/Northern Hemisphere
Daylighting study 21 June/Northern Hemisphere

BEFORE

Ground Floor Plan


Ground Floor Plan
Ground Floor Plan

AFTER

● I add large windows and


● Some areas are under intense I changed the sunshine hours and
Daylighting-related changed the orientation of
sun exposure and some areas added a sun breakers to the roof.
design strategies the building to utilize daylight
are exposed to sunlight.
as much as possible.
Therefore, there were
changes in sunshades and
window sizes.
Belo Horizonte-Tropical Climate
Comparison Ottawa-Continental Cairo,Egypt-Desert Climate

Cooling Loads
Before Before Before
34,698 36,195 45,658

After After After


24,364 12,838 20,073

Cooling-related ● The material change turned ● The material change turned ● The material change turned
design strategies into a natural insulation. into a natural insulation. Stone into a natural insulation. Brick
Concrete. material. material.
● The insulation values in the
glass have changed.
Simulation Period: Winter Solstice
Belo Horizonte-Tropical Climate
Comparison Ottawa-Continental Climate Cairo,Egypt-Deset Climate
21 June/Southern Hemisphere
Solar exposure study 21 December/Northern Hemisphere 21 December/Northern Hemisphere

North Façade East Façade North Façade East Façade

North East East


Façade Façade Façade

BEFORE South Façade West Façade South Façade West Façade

South West South


Façade Façade Façade

North Façade East Façade North Façade East Façade

North East East


Façade Façade Façade
AFTER
South Façade West Façade South Façade West Façade

South West
Façade Façade

Climate-related ● East façade are exposed to a ● East façade are exposed to a ● South façade are exposed to
high amount of solar, high amount of solar, a high amount of solar,
design strategies therefore I add large windows therefore I add sun brakers. therefore I add sun brakers.
to utilize daylight as much as ● Glass sizes are smaller in ● Glass sizes are smaller in
possible. areas with high amount of areas with high amount of
solar. solar.
Belo Horizonte-Tropical Climate
Comparison Ottawa-Continental Climate Cairo, Egypt- Desert Climate
21 June/Southern Hemisphere
Daylighting study

BEFORE

Ground Floor Plan

AFTER

Ground Floor Plan

● I add large windows and


● Some areas are under intense ● I changed the sunshine hours
Daylighting-related changed the orientation of
sun exposure and some areas and removed a sun breakers
design strategies the building to utilize daylight
are exposed to sunlight. to the roof.
as much as possible.
Therefore, there were
changes in sunshades and
window sizes.
Belo Horizonte-Tropical Climate
Comparison City1-Climate1 City3-Climate3

Heating Loads
Before
Before: 5,687 5,733 5,828

After
After: 3,983 2,754 4,086

● The material change turned ● The material change turned


Heating-related ● The material change turned into a natural insulation. into a natural insulation. Brick
design strategies into a natural insulation. Stone material. material.
Concrete. ● The insulation values in the
● The insulation values in the glass have changed.
glass have changed.