Professional Documents
Culture Documents
색으로 해주시면 감
사드리겠습니다.
www.aquacell.co.kr
Address
100, Nakdongnam-ro 533beon-gil, Sustainable environment
Gangseo-gu, Busan
Creates our future.
글자체 우측 페이지 아쿠아셀 TEL
로고 위 Sustainable +82-51-626-4122 / 4755
environment 와 같은 글자체
로 굵은 글자체로 변경 요청 FAX
드립니다. +82-51-626-4756
E-mail
aqua4122@daum.net
We are leading the way
Invites you to the Pollution-Free world.
In 2004, it was finally established under the name of Aquacell Co., Ltd., and is now leading
the way for the future of environment, being committed to create a pollution-free world,
with continuous research and development in the sector of air and water using environmentally
friendly technology.
Our company, in addition, will keep continuing the ethical and transparent management to be
a reliable company as a leader in the environment business based on our technologies and
human resources. We and all of Aquacell members will be always open-minded to
think from the customer's perspective and be sure to make constant efforts
on the basis of technology and credibility.
Aquacell Media
Aquacell Media is formed by mixing environment-friendly zeolite with polyethylene resin
in 3-D structure that has much larger specific surface area and stronger adhesive
power of microorganisms than other media.
◆ Treatment equipment can be compact with the large specific surface area.
◆ The high porosity lowers pressure loss and reduces power costs.
◆ High initial adhesion speed of microorganisms shortens start-up time.
◆ The adhesive power of microorganisms is stronger and
the growth rate of microorganisms is faster.
◆ Environment-friendly materials (Zeolite, PE, etc.) used in Media are recyclable.
06 www.aquacell.co.kr
◆ Characteristics of Aquacell media
Aquacell media - CW
Item Unit CW-SB type CW-SM type
1” 2” 1” 2”
Material PE + Zeolite
Size mm Ø25×H23 Ø50×H46 Ø25×H23 Ø50×H46
Specific Gravity - 1.17~1.2 1.17~1.2 0.99~1.02 0.99~1.02
Unit Surface Area ㎠/EA 74.93 176.49 74.93 176.49
Specific Surface Area ㎠/㎤ 500 270 500 270
Weight g/EA 4.2 20.9 4.0 19.5
Porosity - 0.82 0.84 0.82 0.84
◆ Application
- All kind of Sewage Treatment System(Waste Water, Gray Water, River Water, etc.)
- Microbiological & Chemical Deodorization Facilities
Shape
07
Introduction of item
ℓ를 소문자 l 으로 바꿔주세요.
ℓ를 소문자 l 으로 바꿔주세요. 'HOCl' , OCl- 등.
'HOCl' , OCl- 등.
◆ It solves the safety problems caused from storage, breakage, leakage, etc., without handling
the toxic chemicals directly.
◆ Maintenance is easy, since a storage tank for chemicals is not required.
◆ Deodorization efficiency is maximized through electrolysis, as hypochlorous acid (HOCℓ)
hypochlorite ions(OCℓ-) and OH radicals (˚OH) are generated at the same time.
◆ The use of Aquacell media raises odor removal efficiency and enables the device to be compact.
08 www.aquacell.co.kr
◆ Process chart of treatment
Cleaned Air
Electro-chemical Deodorizer
◆ Application(Odor treatment)
- Wastewater treatment plants - All sorts of sludges during the treatment process
- Sewage treatment plants - Food waste treatment process
- Waste landfills - Livestock wastewater disposal plants
ℓ를 소문자 l 으로 바꿔주세요.
'HOCl' , OCl- 등.
◆ Comparison of odor treatment technologies
09
Introduction of item
Aquacell Auto-Descaler
The Aquacell Auto-Descaler automatically removes and discharges the scales attached
to the heat exchangers and condensing/cooling equipments, using electrolysis with
pole switching method instead of physical or chemical treatment.
It does not require shut-down or any other downtime during the new installation or maintenance.
◆ Unlike physical and chemical methods for cleaning of pipes, tubing/piping materials of
the heat exchanger are not damaged.
◆ As it does not use chemicals, waste water and pollutants are not generated.
◆ It automatically removes scales from the electrodes through the pole switching method.
◆ There is neither damage to the pole plate nor downtime required during the descaling job.
◆ Maintenance is easy, as it is an automatic system.
10 www.aquacell.co.kr
◆ Process chart of treatment
AEDS-1000
Electrolyzed
water to
Cooling cooling tower
recirculation
water Cooling Tower
Site
Cooler &
Heater P P
Compressure
Conditioner Recirculation Drain the formed scale
Pump Pump line to the
electrolysis
◆ The change of scales in the refrigerant pipes before/after installing the equipment
◆ Application
- Automobile industries
- Steel-making, Iron and Metal Production industries
- Shipbuilding and Ship Repair Industries
- Machinery manufacture industries
- Resin & Emulsion manufacturing process
Before operation After operation
-△P
◆ Descaling effects
Decline in productivity Plate lifetime shortening Extended lifetime of facilities (Compressor & Condenser)
Damage in base metal(Refrigerant leakage) Risks of wire cutting on anode Long-time cycle of compressor oil change
11
Introduction of item
Aquacell Scrubber
A scrubber is a device that removes harmful gases, fumes and mist.
The Aquacell scrubber is our technology-intensive equipment of
compact size, with a high treatment efficiency.
Harmful gases
◆ Application
- Factories generating harmful gases
in chemical processes
- Factories & workshops generating
toxic fumes
- Facilities emitting fine particles
- Incineration facilities
Scrubber
12 www.aquacell.co.kr
Aquacell Dust Collector
The Aquacell Dust Collector is an air pulse jet type equipment, which has high collection efficiency,
compact and rare defects.
Especially, it is suitable for high-temperature gas application.
Cleaned air
Cleaned air
AIR PULSE JET
VENTURI
Dusty air
Filter Cloth
Dusty air
◆ Application
- Steel-making, Iron and Metal Production industries - Metallic surface machining process
- Cement Factories - Chemical and Refinery Plant and Factories
- Welding Lines for Auto Mobile Factories - Others that produce heavy dusts and particles
13
Introduction of item
Aquacell RO System
The Aquacell RO system has the best filtration capability that can separate and treat the ionized minerals,
organic matters, bacteria, and germs dissolved in water.
◆ It has an excellent process performance by 88-99.8% for almost all of raw water supply.
◆ It has a variety of applications including water purification equipment,
wastewater reuse equipment, desalination equipment, etc.
◆ Process design and scale-up is simple
◆ The operation procedure is easy
◆ It has less noise and vibration.
◆ SWRO System (Sea Water Reverse Osmosis) ◆ BWRO System (Brackish Water Reverse Osmosis)
◆ Application
- Water treatment and waste water treatment
- De-Ionized Water, Distilled Water, Seawater Desalination
- Chemical industries
- Pharmaceuticals industries
- Surface treatment and mechanical industrial field
Treatment capacity-Sea water: Capacity of 100ton/day Treatment capacity-Sea water:12ton/day, Brackish water:15ton/day
14 www.aquacell.co.kr
Aquacell Electrolysis
Water Treatment System
The Aquacell electrolysis water treatment system uses a technology purifying various levels
of pollutants in water as well as sterilizing harmful microorganisms existing in water
by generating strong oxidizing substances such as HOCℓ, OCℓ-, NaOCℓ, and˚OH by the electrolysis of brine.
◆ Continuous operation is possible, as it does not generate contaminants on the electrode surface.
◆ No additional chemicals is required, as it sterilizes microorganisms with HOCℓ, OCℓ-, NaOCℓ, and
˚OH elements generated from the electrolysis. It has an excellent performance to remove ammonia in water.
◆ It has an excellent performance to remove non-degradable organic compounds, color and odor in water.
◆ Maintenance cost is low, less power consumption, easier operation.
Electrical energy
Indirect oxidation
Non-degradable Decomposition·
Electrode catalyst
Before applying the electrolytic After applying the electrolytic Before sterilizing E. coli After sterilizing E. coli
water treatment system water treatment system
◆ Application
- Advanced treatment of sewage and waste water
- Sterilization processes in desalination plants
- Desulfurization and wastewater treatment systems in power plants
- Food waste treatment and leachate treatment plant
15