After completion of Design Qualification, the inspection is done by the user before the delivery
at the site is called the Factory Acceptance Test (FAT). The manufacturer of a machine will
prepare the FAT protocol based on Design Qualification, as per build machine specification,
calibration certificate, documents of spare and equipment used on the machine. Then this
protocol sends to the client/ user for review and approval.
The user will review and approve the FAT protocol. The user or client will visit the factory of the
machine manufacturer to inspect the ready for a delivery machine as per effective protocol.
Technology - SEC-106H
hine
dicine And Supplement Production. secsoftgel.com
FAT is generally the first stage of system testing and should be witnessed by the customer
period to the agreement for the machine to be delivered to the user site. The manufacture
should ensure that a machine can pass the predefined test Prior to the witness acceptance
testing so as to minimize the risk of any testing.
During factory acceptance testing, the user should test and verify every component of the
machine for operation and functioning as per predefined acceptance criteria.
Thorough HMI (operator interface) review – Verify all buttons and sequencing are
correct. Review all of the HMI or PLC to understand the way to navigate and run the
equipment.
Functional Testing – Check each component and instrument to verify everything is
running to their setpoints, and every parameter is under limit And found satisfactory.
Performance Testing – Run through the mechanical verifications and cross-reference
everything with the P&ID, BOM, GA, and Electrical Drawings.
Review Operation Codes and Sequencing – Run through every recipe, opcode,
opcode editing and verify that everything is sequencing properly within PLC.
Review Alarms and Messages – Execute all alarms and review all information messages
on the HMI.
Mechanical Verification – Check surface finishes and piping slopes, BOM and P&ID
Technology - SEC-106H
hine
Acceptance criteria for FAT (Documentation):
dicine And Supplement Production. secsoftgel.com
Verify a build driving with machine
Calibration of instruments
MOC certificate
Check the safety control, signal, and critical control points as per DQ.
Perform the functional test as per requirement and FAT protocol.
Software requirement to be meet as per 21CFR part 11.
If the machine complies with the URS, DQ, and acceptance criteria, it is recommended for
delivery to the site. The factory acceptance test (FAT) protocol and report shall be reviewed,
approved by the manufacturer and user after completion of FAT and before delivery of the
machine.
If the machine does not comply with the acceptance criteria, the modification shall be
approved through a change control system or can be accepted with the deviation system. FAT
shall be carried out in case of modification. The machine will be delivered to the site after the
completion of FAT.
Technology - SEC-106H
hine
dicine And Supplement Production. secsoftgel.com
25+ Photos Caught At
SEC Softgel
Best IQ Test Online
Medical contract
SEC-106H Softgel
Strictest medical
Machine standards
Ad TeddyFeed Ad secsoftgel.com Ad IQ Test Academy Ad b2b.digiterm.hu
GMP, Validation
Design Qualification in Pharmaceutical industry
Induction cap sealer machine SOP
Leave a Comment
Name
Website
m
o.cm
tneIm
eit txeneht rof rew
osrbsihtni etiw
sb
ed
na , lm
eiam
an
,em
yevaS
Post Comment
Technology - SEC-106H
hine
dicine And Supplement Production. secsoftgel.com
Follow us on
Technology - SEC-106H
Subscribe
Popular Categories
Audit (7)
Cleaning Validation (1)
EHS (1)
Engineering (9)
Equipment (22)
FDA (5)
GMP (21)
Interview preparation (5)
Microbiology (9)
Pharma SOPs (79)
Pharmaceutical companies (11)
Pharmaguideline (4)
Production (34)
Protocol (2)
Quality assurance (9)
Quality Control (22)
Uncategorized (1)
Validation (11)
Recent Posts
SOP on Indent and Approval of Rubber Stereo for Overprinting
Top List of Pharmaceuticals In Bangalore
Fluid Bed Processor (FBP), Principle, and Working
SOP on Cleaning of Coating Solution Preparation Tank
List Of Pharmaceuticals in Delhi/NCR Areas
Sterilization, Method of sterilization, and Objective in Labs
SOP to Initiate, Incorporate, Approve and Record Changes to the Master Documents
List of Pharmaceutical Companies in Paonta Sahib
Search.
Technology - SEC-106H
hine
Privacy Policy About Us Disclaimer Sitemap Term and Conditions Contact us