: 300
UNIT NO.: 265
PN: 265-73-XXX
PAGE: 1 OF 3
1.) Place setting sleeve (1) in vise. Remove shear screws (15), torque screws (14 & 19).
The Weatherford Arrow-Pak delivers high performance with simplicity of design and desirable
2.) Remove set screws (21) from lower cone (20) and remove bottom (27) from lower cone (20).
economics. The Arrow-Pak is set on wireline or on tubing and is easily retrieved. The short design of
3.) Remove bottom (29) from collet (22).
the Arrow-Pak makes it ideal for use in horizontal or deviated wells.
4.) Remove collet (22) from mandrel (12) and remove o-rings (23 & 25) and back-up rings (24 & 26).
The Arrow-Pak is designed with a unique sealing system. This packing element system packs
5.) Remove shear screws (27) from collet (22) and remove support ring (28) from collet (22).
off easily and still resists swab-off during run in and retrieval of the packer. The Arrow-Pak has
6.) Remove lower cone (20) from mandrel (12).
proven itself in gravel pack applications as well as its ability to handle deep, high pressure
7.) Remove upper cone (13) from lower retainer (11) and remove upper cone (13) and slip
completions.
cage assembly from mandrel (12).
8.) Remove slips (17) and slip springs (18) from slip cage (16). Remove upper cone (13) from
SPECIFICATIONS GUIDE slip cage (16).
9.) Remove setting sleeve (1) from the vise and place lower end of mandrel (12) in vise.
RECOMMENDED MIN. 10.) Remove shear screws (4) from setting sleeve (1). Remove setting sleeve (1) from setting
CASING PKR. PKR.
CASING RANGE BORE PRODUCT sleeve adapter (7).
O.D. BORE
O.D. WEIGHT MIN. MAX. THROUGH NUMBER 11.) Remove top body (3) from mandrel (12).
(IN.) (IN.) 12.) Remove setting sleeve adapter (7) from upper retainer (8). Remove set screw (5) from
(IN.) (LBS./FT.) (IN.) (IN.) SEALS
7 29.0 - 35.0 6.004 6.184 5.813 4.000 3.000 265-73-xxx setting sleeve adapter (7) and remove lock ring (6) from setting sleeve adapter (7).
13.) Remove upper retainer (8) from mandrel (12). Remove gage ring (9) from upper retainer (8).
14.) Remove packing element system (10) and lower retainer (11) from mandrel (12).
15.) Clean and inspect all parts. Replace any worn or damaged parts.
SETTING PROCEDURE
ASSEMBLY
Run the Arrow-Pak in to setting depth on wireline pressure setting assembly using the Arrow-Pak
Wireline Adapter Kit or on tubing using a hydraulic setting tool. 1.) Place mandrel (12) in vise with grooves up. Slide upper cone (13) into slip cage (16) and install
Maximum recommended running speed of 180 ft/min. shear screw (15). Install slip springs (18) and slips (17) into slip cage (16).
2.) Slide slip cage assembly (16) onto mandrel (12). Slide lower cone (20) onto mandrel (12) into
slip cage (16).
RELEASING PROCEDURE 3.) Install collet support ring (28) inside of collet (22). Tap support ring (28) flush with collet
fingers and install shear screws (27).
The retrieving tool is run in the hole and set down force is applied when the packer is contacted. A 4.) Install inner and outer o-rings (23 & 25) and back-up rings (24 & 26)onto collet (22) and install
few points is sufficient to fully latch the retrieving tool into the packer. At this point, the release collet collet (22) onto mandrel (12)
is positioned directly below the support ring of the packer. Straight pull will engage the release collet 5.) Thread bottom (29) into lower cone (20). Install set screws (21) in lower cone (20). Rotate
and the support ring. Tension force is applied which will shear the screws in the support ring and shift sub-assembly onto collet (22).
it upward thus releasing the packer. 6.) Place bottom (29) in vise. Install lower retainer (11) onto upper cone (13). Install torque screws
If the support ring does not shear out easily then there is a built in jar stroke in the retrieving tool. By (14 & 19) into upper and lower cones (13 & 20).
jarring upward, either the support ring will shear or the shear ring in the retrieving tool will shear. This 7.) Lubricate mandrel (12) where packing element (10) rests on mandrel (12). Install packing
is a safety shear, which will enable the retrieving tool to be rotated free of the packer if the packer will element (10). NOTE: Make sure element system is flush with upper gage ring (9) and lower
not release. If this is necessary, pull slight tension and rotate to the right approximately 8 turns to retainer (11).
release the retrieving tool from the packer. The shear value of the shear ring is adjustable and should 8.) Install upper retainer (8) onto mandrel (12).
be considered prior to running the retrieving tool. 9.) Install top body (3) onto mandrel (12).
10.) Install lock ring (6) in setting sleeve adapter (7) and install set screw (5).
11.) Install setting sleeve adapter (7) onto upper retainer (8).
12.) Slide setting sleeve (1) over top body (3) and install setting sleeve (1) onto setting sleeve
adapter (7). Install shear screws (4) into setting sleeve (1) and groove in top body (3).
PRODUCT WORKING METALLURGY ON 13.) Install shipping bolt and nut (2).
ELASTOMERS
NUMBER PRESSURE (PSI) FLOW WET PARTS
AISI 4130 - 4145
265-73-XXX 8500 ECNER-ARRAY
105,000 YIELD
© 1999 WEATHERFORD All Rights Reserved. NORTH AMERICAN NUMBERS: HUNTSVILLE, TX PH:800/331-4042 USA 409/295-0080 FAX:409/295-9132 • POWELL, WY PH:307/754-7234 800/458-9202 USA FAX:307/754-5875 REV. 00/DTD: 07-21-99
INDEX NO.: 300
UNIT NO.: 265
PN: 265-73-XXX
PAGE: 2 OF 3
© 1999 WEATHERFORD All Rights Reserved. NORTH AMERICAN NUMBERS: HUNTSVILLE, TX PH:800/331-4042 USA 409/295-0080 FAX:409/295-9132 • POWELL, WY PH:307/754-7234 800/458-9202 USA FAX:307/754-5875 REV. 00/DTD: 07-21-99
INDEX NO.: 300
UNIT NO.: 265
PN: 265-73-XXX
PAGE: 3 OF 3
SIZE WEIGHT PRODUCT DIMENSIONS (IN.) SIZE WEIGHT PRODUCT DIMENSIONS (IN.)
(IN.) (LBS./FT.) NUMBER A B C D E F (IN.) (LBS./FT.) NUMBER G H J K L M
7 29.0 - 35.0 265-73-xxx 67.631 38.626 32.938 17.563 5.125 5.812 7 29.0 - 35.0 265-73-xxx 5.813 4.000 5.781 4.125 5.743 4.200
© 1999 WEATHERFORD All Rights Reserved. NORTH AMERICAN NUMBERS: HUNTSVILLE, TX PH:800/331-4042 USA 409/295-0080 FAX:409/295-9132 • POWELL, WY PH:307/754-7234 800/458-9202 USA FAX:307/754-5875 REV. 00/DTD: 07-21-99