You are on page 1of 3

Detailed Specifications & Technical Data

METRIC MEASUREMENT VERSION

Fire Resistant Marine Instrumentation Cable


59226008
SBM - 201 MA NV ES XLPE/SHF1 B FR CZ (PT/AZ)

For more Information

please call

+55 11 4092-9000

Illustrative Photo

General Description:
Fire Resistant Marine Instrumentation cable, with low smoke and halogen free compound, 1 x 2 x 1 mm2, Voltage: 300V, Conductors: tinned copper, class 2,
Insulation: XLPE, Conductor Operation Temperature: 90 ºC, Core Identification: Black and Blue, Separator: overall polyester tape; Shielding: overall poliester,
aluminum tape and drain conductor , without non-hygroscopic polyester binder thread, Inner Jacket: thermoplastic SHF1, grey color, without non-hygroscopic
polyester ripcord, Armor: tinned copper braid, Outer Jacket: thermoplastic SHF1, grey color with red stripe, with non-hygroscopic polyester ripcord, according
to Standard(s) IEC 60092-376 - 60331-21

Physical Characteristics:
Conductor:

Pairs Cross Section Class Material


1 1mm² 2 Tinned Copper

Total Number of Conductors: 2

Insulation

Material Thickness
XLPE - Cross linked polyethylene 0.8mm

Fire Resistant

Material
Mica tape, according to IEC 60331-21

Outer Shield

Type Material Drain Cross section Drain Material


IS Polyester + aluminum tape 0.75mm² Tinned copper

Inner sheath

Material Thickness Nominal Diameter


SHF1 - Halogen-free thermoplastic compound 1.20mm 9.48mm

Screen

Material Nominal Diameter


Tinned Copper Wire 10.48mm

Outer Jacket

Material Thickness Nominal Diameter


SHF1 - Halogen-free thermoplastic compound, Longitudinal red 1.40mm 13.28mm
stripe in the outer sheath
Overall Cable
Cabling Core Color Code Chart
Core Colors Cable Color
Black and Blue grey

Lay Length
50 - 60 mm

Mechanical Characteristics (Overall)

Operating Temperature Range: 90°C

Nominal Cable Weight: 258.16kg/km

Max Recommended Pulling Tension: 8Kgf

Minimum Bend Radius/Minor Axis: 106.2mm

Nominal Cable Diameter: 13.28 +/- 1.5mm

Applicable Specifications (Overall)


IEC 60228 Conductors of Insulated cables

IEC 60092-360 Insulating and sheating materials for shipboard and offshore units

IEC 60092-351 Insulating materials for shipboard and offshore units and data cables

IEC 60092-350 General construction and test requirements and data cables

IEC 60092-376 Cables for control and instrumentation circuits 150/250V (300 V)

IEC 60331-21 (750°C, 90 min). Tests for electric cables under fire conditions

Flame Test
IEC 60332-1 and IEC 60332-3-22 Category A

Suitability
Sunlight Resistance Yes

Routine Test
Voltage Test 1.5 kV/ 5 min

Electrical Characteristics (Overall)

Nom. Inductance:

Inductance (mh/km)
0.38

Max. Capacitance:

Capacitance (nF/km)
70

Nominal Propagation Velocity:

VP(%)
66

Nom. Impedance:

Impedance (ohm/km)
65

Max. Conductor DC Resistance:

DCR @20°C (ohm/km)


19.3
Minimum Insulation Resistance:

Ri (Mohm/km)
1600

Max Operating Voltage:

Voltage
150/250(300V)

Notes:
IS = Individual Screen.
OS = Collective Screen.
IS / OS = Individual Screen and Collective Screen.
FINAL PUT-UP LENGTH MAY VARY (+ OR -) 3% FOR SPOOLS OR REELS

© 04/26/2022 Poliron

All Rights Reserved.

Although Poliron makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject
to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.

Poliron provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Poliron be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Poliron has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Poliron products are subject to Poliron's standard terms and conditions of sale.

Material manufactured prior to the compliance date may be in stock at Poliron facilities and in our Distributor’s inventory. The information provided in this
Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Poliron's
knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be
considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.

Poliron declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.