Diesel Generator Set K50 Series 1440kWe, 1800 kVA Reliable and Durable Cunmins® ‘KS0 soties’ dese! engine with stiong regrindable crankshaf, high strength connecting rod, low pressure fuel lines, ESTC (Step Timing Controls) injectors and high volume coolant system make ‘K50 series’ generating sets, more relable and durable Engines have clocked ‘ilions of hours operating in some of the world’s most demanding conditions, Current engines are regulary upgraded with now technologies for better performance and economy. The ultimate proof of superior performance and reliability is tho fact that Cummins® entities worldwide ‘source these engines trom Cummins India for thor markets Unmatched Warranty Cursminse 'K50 series’ dlesel engine generating sets are a truly cost effectve solution ta long term power need backed by industry best, 2 yoars / $000 hrs ‘warranty, forthe entire generating set with superior experience in technology. design Ccapablity and commitment reality ané qualty we offer an unmatched 5 years or 5000 hours (including ‘above 2 years) warranty coverage on 5 crtcal ‘components (5C) of the engine ~ Cylinder Hea, Camshaf, Crankshat, Gyinder Block, Connecting Rod against manufacturing defect Cummins Advantage Special features of Cumminse KS0 series’ engines lke ESTC (Electrical Step Timing Control) injectors, BCS (Gank Cut off System), low temperature aftercooler, ‘square combustion chamber, optimised turbocharging ‘and precision heavy duly camshaft make these fongines the timate in exceptional fuel efficiency ‘across the operating range. ingle Source Power Assurance Design, manufacture and testing of engine, ‘and olner accessories is dane by Cummins Group of ‘companis for optimum performance and is backod by «a countywide product support network with a single ‘Source responsiiity for the entire package, temator Standard Scope Engine: Cumminse 50 series’ dec injection, water cooled engine, 16 cylinder, 4 stoke, rated at 1500 RPM, conforming to ISO 3046 / IS 13018 has the following specifications: + Cummins PT fuel pump + Cummins heavy duty ESTC injectors Folset turbocharger, pulse tuned exhaust mman‘olc, Stainless steel exhaust flexible conections Radiator 8 coolant inhtor Piato type lab ol coolor Outboard aftercoolers Fl ow Spin-on lype Lube oil & Fusl ites with Water Separators = Dry ype replaceable paper element air ceaner vith restriction indicator + Flywhee! housing & fywheel to sul single bearng- Flywheel housing & fywhee! size SAEOITE + Starting motor — Electric, battery charging aterator + Cummins PowerCommand® microprocessor based genset controller * Firs fille ol and coolant Alternator: Stamford brushless altemator + Separately excited, set-regulated - Class ‘HW insulation * Saliont pole revohing fold + Single bearng * PMG standard + Space heater & RTD & STD's only sensor - (wtnout scanner) ‘Accessories: + Silencer suitably optimizes to reduce * Stuy base rail * 90 ts. re standing fuel tank +2 x 12 V ory, uncharged batteries with connecting leads and terminals. Diese! Generator Set K50 Series Optional Engine: OlCoovant heater, No ool Control Panel: PC3.3, Power factor, Frequency, Current, Voltage - Remote HMI AMF control panel, Battory charge, RemotelAuto start panel, Auta! Manual synchronizing panel, AucioVisual annunciaton for faults, Auxiliary output relays and remote annunciators Control panel: PowerCommands PC 3.3, The PowerCommande contol system isan inlogratod microprocessor based generator set control systam providing voltage regulon, engine protection, altemator protection, ‘operator intoface and Isochronous governing AmpSentrym Includes integral AmpSentyTM protection, which provides @ full range of atemator protection function which are matched to the altemator provided. Power Management ~ Control function provides battery ‘monitoring, testing ané a smart staring contol system. ‘Advanced Control Methodology — Three phaso sensing FET based full wave rectified voltage regulation and @ PWM output for stable operation with al load types. Communications Interface — Control comes standard with PCCNet and Modbus interface. Regulation Compliant - Prototype tested: UL, CSA and CE compliant. Service - InPower™ PC-based service tool available for dolaileé agnostics, solup, data logging and faut simulation, Reliable Design — For reliable operations in harsh environment Multldanguage support Indopendent of PC! laptop for setting up Operator panel features ‘Operator Panel Features ~ The operator panel, in additon torte altemator,csplays the Utty! AC Bus data Operator! Display Functions + 320 x 280 pixels graphic LED backght LCD with bar graph for displaying electrical parameters ‘Auto, manual, star, stop, faut reset and lamp testipanel lamp switchos Alpha-numaric display wih pushbutlons LED lamps indicatng gonset runing, romoto star. not in auto, common shutdown, common warning, manual run mode, auto mode and siop ing Control Functions + Digital frequency synchronization and votage matching * Isochronous KV and kvar load sharing conrols * Droop kW and kvar cont! + Syne check + Extended paralielng (Peak ShavelBase Load) * Digital power transfer conirl (AMF) provides load transfer ‘peralion in open or closed transton or got ramping) transfer mode Par Specifeation Shoot ‘Alternator Data * Line-o-noutral& line-tosine AC Volts + S-phase AC current 1 Frequency + KW, kvar, power factor KVA (three phase and total) Engine Data * DC voltage + Engine spese * Lube a pressure * Coolant temperatura low level + Comprehensive FAE data (where applicable) Other Data + Genset model data + Start attempts, starts, running hours, KW hours * Load profle (operating hows at % load in 5% increments) * Fault history + Data logging and faut simulation (requires InPower) Standard control functions Digital Governing + Integrated digital electronic tsochronous governor ‘Temperature dynam governing Digital Voltage Regulation + Inlograted dgtal electronic voltage regulator 1 S.phase, 4-wire line-lorline sensing + Configurable torque matching “AmpSontrym AC Protection + AmpSentry protective relay + Over eurent and short circu shutdown * Over curent warning + Single and three phase faut regulation * Over and under vottage shutdown + Over and under frequency shutdown * Overload warning with alam contact + Reverse power and reverse var shutdown + Field overoad Engine protection * Battery vollage monitoring, protection and testing * Over speed shutdown * Low ol pressure waming and shutdown + High coolant temparature warming and shutdown * Low coolant lava warning or shutdown * Low coolant temperature warning Fal to start (over crank) shutdown * Fall to crank shutdown * Cranking lockout * Sensor failure indication * Low fue level waning lomatics Offerings Fault Code Alerts on Email & SMS Advisory Services Fuel Love! Monitoring on Email & SMS Muliple Gensots Central Monitoring ‘Automatic Reports Generation Diesel Generator Set K50 Series Control functions ‘Time delay start and cool down Realtime clock for fault and event time stamping Exerciser clock and time of day tartstop Data logging (yale cranking Load shed! dump as per configurable pristy Configurable inputs and outputs (4) = Remote emergancy stop Options = Auxiliary output relays and remote annunciators Gonorator sot specication Modal No.of pasos Engine specications see No.of eyingers Aspraton Displacement Fs! consumption @ 78% load Fue consumption @ 100% ond “Toil wet wag (engine + radon) engl x Width x Height (engine) [Compression Rao Piston Spees ‘Governor Class Lubricatg os s)tam capacity (Conant capacity (engine + rat) [Combustion a ike @ 100% fad (5%) [Atemstor specications Frame #20 | Model No. Votage Reguaton Insulation ‘Stator Weding| Rover ‘Teleshone inrtronco ‘Total Haranie Factor Conformance standards jcre00 05° 498 Vos, 50 He 03 cag) ‘sPhase cummins wv TubocrargecAtercoated 2101 bh (1867 kin) 291 eine 286 ihr 198719 795m Eleevonie A 500 es src Stamion tT Is7i10-c4 ‘class 2/9 Phen Dynamical bainces win grade 25, Noloed 15%, Non-saoring anced tnear load = 6% THe ‘eter than 2% ISMIEC 60034-1, IS 1460, ISO 6528, ISO 3045, IS 13018, ISO 9001, Rating definitions Prime Power (PRP): ‘Applicable for supplying power to varying electical load for unlimited hours, Prime Powor (PRP) isin accordance with [SO '8528, Ton porcent overload capabilly' avaible in accordance with ISO 3046, = Fuol consumption data is based on dlosel having specific gravy of 0.85 and conforming to IS:1460 “Ful consumption tolerance is +5% Diesel Generator Set K50 Series ‘Typical Open Genset Dimensions ‘Specfeation Shest Gonset Rating Length wt Height WetWeightw | Standard Fuel Tank Model vay (mm) (eum) (um) (ka) Capacity - External (©1800 D5 P sg00kvA [5870 2670 3395 13250 990 1 Approximate Weight "Our energy working for you.” aoe Autbrted Representative Cummins Power Stems Ofexs Bangs Ta (80 256 014 65,2505 6185/67 Fee oa) as ote cmenigan Taser) 204 oare73 Pectarasaetams hema: Ta oe 2a ana ass eg) a61 120 Gumsen: Ta tat 91 cana Teelaicuae a ree Ta (0240970240980 Fae at) 240 9000 ssn Fa ptanpa ue Feat) a03579¢ esas a 27 Gs 257 2 89) 20 3880 Loctowe —Ta see 2009) 20558 Tee tasz) 20st Morais a ome an cart 172179 Fae ua) zatoae/ 2! tesa: Tals 209 265927 eas) 20823 S = Eee ee Eel gage cin

You might also like