Professional Documents
Culture Documents
700.00
600.00
Caudal (m3/s)
500.00
400.00
H-Entrada
H-Descarga
300.00
200.00
100.00
0.00
0 5 10 Tiempo15(dias) 20 25 30
Datos:
K= 2 horas
X= 0.1
Δt= 1 hora
C =
( K)
Δt
−2 X
C 1=
( K)
Δt
+2 X
C =
2 (1− X )−( K )
Δt
2 (1−X )+ ( )
2
2 ( 1−X )+ (
K )
O
2 ( 1− X ) +( )
Δt Δt Δt
K K
O2 =CO I 2 +C 1 I 1 +C2 O 1
1
Flujo Parcial
Tiempo Afluente Descarga
I CO I 2 C1 I 1 C2 O1 O
Horas m3/s m3/s m3/s m3/s m3/s
0 3.30 3.30
1 58.11 7.58 1.00 1.87 10.45
2 223.22 29.12 17.69 5.91 52.71
3 442.47 57.71 67.94 29.79 155.44
4 606.92 79.16 134.67 87.86 301.69
5 660.63 86.17 184.71 170.52 441.40
6 550.78 71.84 201.06 249.49 522.39
7 332.18 43.33 167.63 295.26 506.22
8 167.74 21.88 101.10 286.12 409.10
9 58.11 7.58 51.05 231.23 289.86
10 3.30 0.43 17.69 163.84 181.95
11 3.30 0.43 1.00 102.84 104.28
12 3.30 0.43 1.00 58.94 60.37
13 3.30 0.43 1.00 34.12 35.56
14 3.30 0.43 1.00 20.10 21.53
15 3.30 0.43 1.00 12.17 13.61
16 3.30 0.43 1.00 7.69 9.13
17 3.30 0.43 1.00 5.16 6.59
18 3.30 0.43 1.00 3.73 5.16
19 3.30 0.43 1.00 2.92 4.35
20 3.30 0.43 1.00 2.46 3.89
21 3.30 0.43 1.00 2.20 3.64
22 3.30 0.43 1.00 2.06 3.49
23 3.30 0.43 1.00 1.97 3.41
24 3.30 0.43 1.00 1.93 3.36
25 3.30 0.43 1.00 1.90 3.33
Calibracion Parametros Muskingum
Peso Relativo Flujo (m3/s)
14000.00
12000.00
10000.00
8000.00
X=0.1
Linear
(X=0.1)
6000.00
X=0.2
X=0.3
4000.00
2000.00
0.00
0.00 1000.00 2000.00 3000.00 4000.00 5000.00 6000.00 7000.00
Almacenamiento (m3/s)
Transito en Cauces Metodo Muskingum
Δt= 1 dia
500.00
0.3 450.00
400.00
168.00
195.00 350.00
217.00
300.00 Column
373.00 N
386.00 250.00 Column
450.00 O
200.00
411.00
350.00 150.00
275.00
100.00
200.00
50.00
0.00
0.00 200.00 400.00 600.00 800.00 1000.00 1200.00 1400.00
734.43
602.59
496.68
433.78
398.22
Datos:
K= 1.2 dias
X= 0.3
Δt= 1 dia
C =
( K)
Δt
−2 X
C 1=
( K)
Δt
+2 X
C =
2 (1−X )− ( K )
Δt
2 (1− X )+ ( )
2
2 ( 1− X ) + (
K)
O
2 ( 1− X ) +( )
Δt Δt Δt
K K
O 2 =CO I 2 +C 1 I 1 +C 2 O 1
1
Flujo Parcial
Tiempo Afluente Descarga
I CO I 2 C1 I 1 C2 O1 O
dias m3/s m3/s m3/s m3/s m3/s
0 6 6
1 18 1.88 3.85 1.52 7.25
2 31 3.24 11.55 1.84 16.63
3 35 3.66 19.90 4.22 27.77
4 33 3.45 22.46 7.05 32.96
5 28 2.93 21.18 8.36 32.47
6 23 2.40 17.97 8.24 28.61
7 19 1.99 14.76 7.26 24.01
8 15 1.57 12.19 6.09 19.85
9 12 1.25 9.63 5.04 15.92
10 9 0.94 7.70 4.04 12.68
11 6 0.63 5.78 3.22 9.62
12 6 0.63 3.85 2.44 6.92
13 6 0.63 3.85 1.76 6.23
14 6 0.63 3.85 1.58 6.06
15 6 0.63 3.85 1.54 6.02
16 6 0.63 3.85 1.53 6.00
Transito en Cauces Metodo Muskingum
Δt= 1 dia
30.00
25.00
20.00
Column
15.00 F
10.00
5.00
0.00
0.00 5.00 10.00 15.00 20.00 25.00 30.00 35.00
Column
F
0
Calibracion Parametros Muskingum
35.00
Almacenamiento(m3/s)
30.00
25.00
20.00 X=0.2
X=0.3
Linear (X=0.3)
15.00 X=0.4
10.00
5.00
0.00
5.00 10.00 15.00 20.00 25.00 30.00 35.00
Flujo Relativo(m3/s)
Datos:
K= 1.21 hora
X= 0.3
Δt= 1 hora
C =
( K)
Δt
−2 X
C 1=
( K)
Δt
+2 X
C =
2 (1−X )− ( K )
Δt
2 (1− X )+ ( )
2
2 ( 1− X ) + (
K)
O
2 ( 1− X ) +( )
Δt Δt Δt
K K
O 2 =CO I 2 +C 1 I 1 +C 2 O 1
1
Flujo Parcial
Tiempo Afluente Descarga
I CO I 2 C1 I 1 C2 O1 O
dias m3/s m3/s m3/s m3/s m3/s
0 2.00 2.00
1 53.37 5.43 1.28 0.52 7.22
2 139.48 14.19 34.19 1.86 50.24
3 278.49 28.32 89.36 12.94 130.63
4 429.08 43.64 178.42 33.65 255.71
5 429.08 43.64 274.90 65.87 384.42
6 278.49 28.32 274.90 99.03 402.26
7 139.48 14.19 178.42 103.62 296.23
8 93.15 9.47 89.36 76.31 175.15
9 2.00 0.20 59.68 45.12 105.00
10 2.00 0.20 1.28 27.05 28.53
11 2.00 0.20 1.28 7.35 8.84
12 2.00 0.20 1.28 2.28 3.76
13 2.00 0.20 1.28 0.97 2.45
14 2.00 0.20 1.28 0.63 2.12
15 2.00 0.20 1.28 0.55 2.03
16 2.00 0.20 1.28 0.52 2.01
17 2.00 0.20 1.28 0.52 2.00
Δt= 1 dia
Δt= 1 dia
k X x Y
10.44 5.4
32.93 32.65
22.49 27.25
1.21164962
K=
K=
X=
Δt=
C =
(
Δt
K )
−2 X
C 1=
( K)
Δt
+2 X
C =
2 (1− X )− ( K )
Δt
2 (1−X )+ ( )
2
2 ( 1− X )+ (
K )
2 ( 1− X ) +( )
O
Δt Δt Δt
K K
CO = C1 = C2 =
CO +C 1 +C 2=1
O 2 =C O I 2 +C 1 I 1 +C 2 O 1
1
CO I 2 C1 I 1 C2 O1
RIO MAXES
Hora 0 1 2 3 4
Entrada (m3/s) 6 18 31 35 33
Salida (m3/s) 6 7.2 16.5 27.7 32.9
5 6 7 8 9 10 11
28 23 19 15 12 9 6
32.5 28.6 24 19.9 15.9 12.7 9.6
Datos:
K= 1.21 hora
X= 0.3
Δt= 1 hora
C =
( K)
Δt
−2 X
C 1=
( K)
Δt
+2 X
C =
2 (1−X )− ( K )
Δt
2 (1− X )+ ( )
2
2 ( 1− X ) + (
K)
O
2 ( 1− X ) +( )
Δt Δt Δt
K K
O 2 =CO I 2 +C 1 I 1 +C 2 O 1
1
Flujo Parcial
Tiempo Afluente Descarga
I CO I 2 C1 I 1 C2 O1 O
dias m3/s m3/s m3/s m3/s m3/s
0 2.00 2.00
1 53.37 5.43 1.28 0.52 7.22
2 139.48 14.19 34.19 1.86 50.24
3 278.49 28.32 89.36 12.94 130.63
4 429.08 43.64 178.42 33.65 255.71
5 429.08 43.64 274.90 65.87 384.42
6 278.49 28.32 274.90 99.03 402.26
7 139.48 14.19 178.42 103.62 296.23
8 93.15 9.47 89.36 76.31 175.15
9 2.00 0.20 59.68 45.12 105.00
10 2.00 0.20 1.28 27.05 28.53
11 2.00 0.20 1.28 7.35 8.84
12 2.00 0.20 1.28 2.28 3.76
13 2.00 0.20 1.28 0.97 2.45
14 2.00 0.20 1.28 0.63 2.12
15 2.00 0.20 1.28 0.55 2.03
16 2.00 0.20 1.28 0.52 2.01
17 2.00 0.20 1.28 0.52 2.00
Riesgo Falla