clerestory
REFERENCE FINISH
wall plate level +2.877 clerestory clerestory
W01
SECTION X
windows windows windows
GENERAL NOTES
230
lintel level +2.100
2,070
2,298
230
S.A.Z specification standards. The trade
W02 aluminium slidding door to specialist ngl contractor shall provide finished mock-ups
ab NDS6 -0.235 and samples as noted or required by the
natural anodised exact dimesions to be contract documents for approval by the
mm clear glass
1 2,581×951 aluminium frame verified on site
Architect prior to fabrication.
230
230
230
W04
This drawing is not to be scaled, figured
SOUTH front ELEVATION
1,253
ab Scale 1:100
dimensions to be used at all times. Unless
noted otherwise, all dimensions are given
494 in millimetres.
W04
115
Contractor is responsible for the correct
3,273
W03
3,040
W01
3,022
3,040
115 676
boundaries, building lines, etc.
Contractors are to locate and identify, if
LOUNGE conc. conc. any, existing services on site, and to
(Tiles) coping coping protect these from damage throughout the
parapet height +3.742
natural anodised
mm clear glass
exact dimesions to be duration of the works.
+00.00 1 1,802×951 aluminium frame verified on site
230
3,312
W02 for coordination of work. The work of all
WEST ELEVATION
disciplines shall be carefully co-ordinated
head of drain 450 wall plate level +2.877
with the overall aesthetic appearance of
rw
2,291
the building.
below n.g.l
230
230
All relevant details, levels & dimensions to
W04
959
14,289
DINING
3,065
KITCHEN natural anodised exact dimesions to be brought to the immediate attention of the
115
3,388
3,370
W04
+00.00 mm clear glass
(C. Tiles) 11 388×1,890 aluminium frame verified on site project manager and the Architect.
03
1,373
W
sink +00.00
Drawings & details show design intent and
EAST ELEVATION
W04
2,056
115
W04 W04 g i.e g i.e parapet level & to all windows, doors,
115
115
stove LINEN ngl
grilles or other opening in external walls.
-0.235
g dia. 100 sewer drain pipe at 1:60 fall torwards municipal pipe line Stepped brickgrip dpc to all external cavity
420
1,801
W05
1,100
1,100
(C. Tiles) natural anodised
mm clear glass
exact dimesions to be above n.g.l.
ROAD
W04
Scale 1:100
FLD +00.00 Any queries arising from all the above
115
115
FLD Airbricks to local authority requirements, if
385
115
115
W04
600
8 M BOUNDARY LINE
3,070
848
BIC
115
1,845
115
W04
5,235
W06
PASSAGE
3,560
3,560
BATH RM FOUNDATIONS
+00.00
(Tiles)
1,600 115
hwb
STORE
2,597
tub
tub
+00.00
WALLS:
W/C Walls to be brickforced as per engineer's
specifications
NE
Selected facebricks where specified by
BIC
LI
natural anodised exact dimesions to be designer or project owner
RY
2 1,802×951 aluminium frame
mm clear glass
verified on site
DA
FLOOR SLAB
230
230
230
230
W05 W06 W05 W07 W04 W04
UN
to engineer's design and detail
20 M BOUNDARY LINE
g i.e g i.e rw
BO
dia. 100 sewer drain pipe at 1:60 fall torwards municipal pipe line
M
115 SKIRTING
STD 9870 W07
28
230 4,459 230 3,069 115 1,502 115 1,115 1,198 115 4,115 230 Skirting to specialist detail (minimum
skirting :100X19) in hardwood or
SECTION X
selected softwood
16,609 WINDOW SILLS
natural anodised
mm clear glass
exact dimesions to be Selected window sills on dpc laid at slope
1 600×1,000 aluminium frame verified on site to drain
PROPOSED RESIDENTIAL LINTELS, BEAMS
NORTH ELEVATION HOUSE ON STAND N0. 9871 Lintels, beams and columns to engineer's
rw design and detail
STD 9872
AIRVENTS
SEWER DISPOSAL
110dia rigid pvc sewer pipes
110dia pvc vent pipes
50dia waste water pipes
ie g ie P-trap gullies
2100
2100
g
connection
dia. 100 sewer drain pipe at 1:60 fall torwards municipal pipe line
point
municipal sewer line
ngl
±0.000
brandered ceiling
-0.235 r.w g
dia. 100 sewer drain pipe at 1:60 fall torwards municipal pipe line
brandered ceiling
EAST (side) ELEVATION
Scale 1:100
+2.100
lintel level
i.e
230 X 230 X
3,557
3,146
230conc. 230conc.
2,794
lintol lintol
LOUNGE
conc. conc. plaster and paint PASSAGE
parapet height +3.742
coping coping
plaster and paint
BEDROOM dpc at 150mm above
wall plate level +2.877
plaster and paint the ground placed
lintel level +2.100
ffl ±0.000 d.p.c. d.p.c. d.p.c. overlaping dpm
ngl Engineer:
-0.235
Cells:
plaster and paint
E-mail :
svp
dia. 100 sewer drain pipe at 1:60 fall torwards municipal pipe line
E-mail: irkanedesign@yahoo.com
concrete footing concrete footing concrete footing concrete footing concrete footing
on well compacted hardcore
NAME: ...................................................................
DATE: ........................................................................
SIG: ..................................................................................
IDG
C
dds
Copyright reserved
SECTION X-X IAZ Reg. No. : A12/004
PS
A2
Scale 1:50
December 2018
Contractor : On this sheet : Rev Date By Description Designed W.S FEB 2021 Drawing No. Sheet 01 Of 01
PROJECT
Proposed residential house Floorplan
Drawn T.M. FEB 2021
Section IDG-02 SM 2021/2-2
LOCATION
Stand No 9871 WAREN PARK Elevations
Checked
Cells:
Copies Window and Door Scale(s)
CLIENT
Chosen. Chamburuka issued
Schedule as shown IDG Revision number