You are on page 1of 9

38 FEET

WASH BASIN
BIOSAFETY 6 X 17 FEET A/C INCUBATOR ROOM 6 X 22 FEET A/C

LAMINAR AIR FLOW -3 7 X 12 FEET DECONTAMINATION 7 X6 SAMPLE EXTRACTION ROOM 7 X9


FEET FEET

LAMINAR AIR FLOW -2 7 X 12 FEET

GCMSMS/LCMSMS 13 X 15
CORRIDOR 5 X 59 FEET

STERILIZATION ROOM 6 X 12 FEET ( EXHAUST )


6 FEET
59 FEET

MEDIA PREPARATION ROOM 8X 12 FEET A/C GENERAL INSTRUMENT 7 X 15


WATER SUPPLY
WITH WASH BASN

SAMPLE STORAGE / RECEIPT ROOM 5 X 12 FOOD AND WATER 12 X 15


Laminar-1
DOCUMENTATION ROOM 6 X 12 FEET

HOT ZONE 5 X 10
MICRO CHANGE
ROOM- 5 X 8

ENTRANCE

LIFT 6 X 6 FEET FREE PLACE TOILET 6 X 6 FEET

ENTRANCE 10 FEET
38 FEET

storage WASH

analysed
Samples
BASIN
BIOSAFETY 6 X 17 FEET A/C INCUBATOR ROOM 6 X 22 FEET A/C

LAMINAR AIR FLOW -3 7 X 12 FEET DECONTAMINATION 7 X6 SAMPLE EXTRACTION ROOM 7 X9


FEET FEET

LAMINAR AIR FLOW -2 7 X 12 FEET

GCMSMS/LCMSMS 13 X 15
CORRIDOR 5 X 59 FEET

STERILIZATION ROOM 6 X 12 FEET ( EXHAUST )


6 FEET
59 FEET

MEDIA PREPARATION ROOM 8X 12 FEET A/C GENERAL INSTRUMENT 7 X 15


WATER SUPPLY
WITH WASH BASN

SAMPLE STORAGE / RECEIPT ROOM 5 X 12 FOOD AND WATER 12 X 15


Laminar-1
DOCUMENTATION ROOM 6 X 12 FEET

HOT ZONE 5 X 10
MICRO CHANGE
ROOM- 5 X 8

ENTRANCE

LIFT 6 X 6 FEET FREE PLACE TOILET 6 X 6 FEET

ENTRANCE 10 FEET
Wash
basin
Sample
Biosafety cabinet 6x 12 Incubation room 6 x 18 s after
gut provision for out side A.C test
A.C

Sample extraction room


Laminar airflow-3 Decontamination 7x 14
7 x 12 A.C 7x6

Laminar airfolw-2
7 x 12 A.C
GC MSMS/LCMSMS
13 X 14

Sterilization room
6 x 12 Exhaust

5 FEET

Media preparation room


8 x 12 A.C
Water supply with wash basin General Instrument
Change 7 X14
room
5 X 5 Air
shower 6 FEET

samples receipt/storage room


Laminar-1 A.C
5 x 12
Food & water
13 x 14
11 X 12 FEET

Documentation room /Staff area


6 x 12

H.O.D Room HOT ZONE 5 X 9FEET


7 X 6 FEET FREE SPACE - 7 X 22 FEET

6X10 FEET LIFT 6 X 6 FEET 6 X 16 FEET TOILET 6 X 6 FEET


6+7+13+7+12+5+3+6
VITRO LABS PROPOSED LAYOUT -DRAFT
38 FEET
12+5+21 38
6+7+7+6+8+5+
6+5+6 WASH BASIN

BIO-SAFETY 6 X 12 INCUBATION ROOM


MC-6 6 X21 A.C
MC-7
12+5+6+6+9 38
DECONTAMINATI
ON ROOM
7 X 6 WASH
BASIN SAMPLE EXTRACTION ROOM 7X 9
M MC-8
I
C
R
LAMINAR AIR FLOW 1&2 ,A.C 14 X 12 MC-5 O
12+5+6+15 38
C
5 O
9 R
F R
E I
E D
T O GCMSMS/LCMSMS
13 X 15
R

STERILIZATION ROOM
6 X 12
EXHAUST
MC-4

12+5+6+15 38

MEDIA PREPARATION ROOM 12+5+6+15 38


8 X 12 A.C GENERAL INSTRUMENTS
WATER SUPPLY WITH WASH BASIN 7 X 15
MC-3
CHANGE ROOM

12+5+6+15 38
SAMPLE RECEIPT/STORAGE ROOM
5 X 12 LAMINAR -1 A.C
MC-2

COMMON OPEN SPACE AREA FOOD AND WATER


12 X 15

DOCUMENTATION ROOM
6 X 12 A.C MC-1
12+5+6+15 38

HOT ZONE 5+23+10 38


5 X 10
8X5
HOD COMMON SPACE AREA
ROOM

ENTRANCE
10+6+16+6 38
FREE PLACE
LIFT 6X6 TOILET 6 X 6

ENTRANCE
10 FEET
6+7+13+7+12+5+3+6
MICROBIOLOGY LAB -UNI DIRECTIONAL LAYOUT
38 FEET
12+5+21 38
6+7+7+6+8+5+ BIO-SAFETY 6 X 12 Microscope
6+5+6 INCUBATION ROOM Colony counter WASH BASIN
MC-6 Biosafety 6 X21 A.C Samples storage
cabinet, MC-7 (incubators, water bath after testing

Pass box
Pass box DECONTAMINATIO 12+5+6+6+9 38
N ROOM
7 X 6 WASH BASIN
MC-8 washing
facility and SAMPLE EXTRACTION ROOM 7X 9
M autoclave for
I decontamination).
C
LAMINAR AIR FLOW 1&2 ,A.C 14 X 12 MC-5, Laminar R
flow cabinets, Water bath and Stomacher O
12+5+6+15 38
C C
5 O o
9 R m
F R m
E I o
E D n
T O GCMSMS/LCMSMS
Pass box 13 X 15
R c
STERILIZATION ROOM o
6 X 12 r
EXHAUST r
MC-4[steam sterilizers / i
autoclaves, hot plate, hot air d
oven] o
r
Pass box 12+5+6+15 38

MEDIA PREPARATION ROOM 12+5+6+15 38


8 X 12 A.C GENERAL INSTRUMENTS
WATER SUPPLY WITH WASH BASIN 7 X 15
MC-3 [weighing balance, pH meter, CHANGE ROOM
Refrigerator, Media storage cabinet Aprons
cabinet/Cross
over bench

Pass box
12+5+6+15 38
SAMPLE RECEIPT/STORAGE ROOM Entry Exit
5 X 12 LAMINAR -1 ,Refrigerator
A.C
MC-2

COMMON OPEN SPACE AREA FOOD AND WATER


12 X 15

DOCUMENTATION ROOM
6 X 12 A.C MC-1
12+5+6+15 38

HOT ZONE 5+23+10 38


5 X 10
8X5
HOD COMMON SPACE AREA
ROOM

ENTRANCE
10+6+16+6 38
FREE PLACE
LIFT 6X6 TOILET 6 X 6

ENTRANCE
10 FEET
Main entrance

LIFT6 X6

Documentation room 5x12

MC-1 A.C

SAMPLE RECEIPT ROOM 6 X 12


ENTRY/EXIT
MC-2 Laminar-1, CHANGE ROOM
Refrigerator, A.C
Cros
PP over WET ROOM
MEDIA PREPARATION 7 X 12 bench/A
Aprons
cabinet
MC-3, WATER SUPPLY
WITH WASH BASIN
Weigh
balance,PhMeter,Refr
igerators. storage
cabinet

STERILIZATION ROOM 5 X12

MC-4 Exhaust
Autoclave, Hot
plate GENERAL INSTRUMENTS

LAMINAR AIR FLOW 12 X 12

MC-5 Laminars,
Water bath, S.S
Steel Table,
Stomacher,Water
bath LCMS ROOM

BIO SAFETY 6 X 12
MC-6 Bio safety
cabinet

LCMS ROOM
INCUBATION ROOM 7X 12

MC-7 E Exhaust,
Incubators, Water
bath, Colony
counter,Micro
scope

DECONTAMINATIONROOM 6 X12

MC-8, Exhaust
Autoclave Wash
basin for washing HOT ZONE

Air showers for Change room, Laminar room and Biosafety room