DURAN® Beaker
10 21 106 08 04 1
– – – –
25 21 106 14 06 – – – –
Working under pressure and vacuum • When working at low temperatures, the effect • To care properly for laboratory glassware, it
of any expansion of a DURAN® vessel’s contents should be washed immediately after use at
• DURAN® Beakers are in general not suitable
must be borne in mind. Therefore the glass low temperature, on a short cycle and with
for use under pressure or in a vacuum.
products should be frozen slanted at an angle low alkalinity.
of 45°, filled to a maximum of ¾ of its capacity
• Laboratory apparatus that has come into
Temperature resistance (to enlarge the surface area).
contact with infectious substances or micro-
• The maximum permissible short-term oper- • During cooling and thawing ensure that the organisms should be treated in accordance
ating temperature for DURAN® is 500 °C. temperature difference does not exceed 100 with the current guidelines.
K. In practice, therefore, stepwise cooling
• The maximum thermal shock resistance is
and heating are recommended. Manual cleaning
∆T = 100 K.
• Frozen contents can be thawed by • The generally recognized method is to wipe
• Only subject DURAN® glassware to sudden
immersing the bottle in a liquid bath while and rub the glass with a cloth or sponge
temperature changes within the recom-
taking care that the temperature difference soaked in cleaning solution. Abrasive clean-
mended limit for thermal shock resistance
between the contents and the bath does not ers and abrasive sponges should not be
(ΔT = 100 K).
exceed ΔT = 100 K. This will ensure that the used on laboratory glassware as these can
• Before using, the glass surfaces of the frozen material is warmed uniformly from damage the surface of the glass.
DURAN® Beakers have to be checked for every side without damaging the beaker.
• Surface damage can affect the glass proper-
damages such as scratches, cracks or nicks. The contents can, however, also be thawed
ties and limit further use of the product.
Damaged beakers must not be used for slowly from above, so that the surface melts
safety reasons. first, allowing the material to expand. • Laboratory glassware should not be soaked
for long periods in alkaline media at more
Temperature resistance at low temperatures than 70 °C since this can have an adverse
Autoclaving/Sterilisation effect on the printing and may cause glass
• DURAN® can be cooled down to the max-
• DURAN® Beakers are autoclavable/ corrosion. Also to be avoided is severe
imum possible negative temperature and
sterilizable. mechanical action e.g. scraping using a
is therefore suitable for use with liquid
metal spoon.
nitrogen (approx. –196 °C). As the geometry
influences the thermal properties, it is Cleaning Automatic laboratory glassware reprocessing
recommended that only small-volume glass
• Cleaning should be carried out manually
vessels be exposed to very low tempera- • When cleaning in a dishwasher, load so that
in a soaking bath or automatically in a
tures. Moreover the thermal properties of there is no glass-to-glass contact (especially
dishwasher.
any screw caps or other components used the threads) to avoid chips or abrasions.
must be borne in mind.
ID 32034, NO 001/09.2020