Operating data
Flow 32 m³/h Fluid Water
Head 8m Density 998,3 kg/m³
Geodetic head 0m Viscosity 1,005 mm²/s
Efficiency 35,339 % Temperature 20 °C
Shaft power P2 1,7374 kW No. of pumps 1
Pump
Head H(Qmax) 3,5076 m Impeller type Vortex type impeller
Flow (max) 43,2 m³/h Impeller 140 mm
Shut off head 17,996 m Suction size 51
Max. efficiency 40,188 % Discharge size DN 50
Free passage 45 mm
Motor
Phase 3~ Speed 2.850 1/min
Frequency 50 Hz Efficiency 77,2 %
Rated voltage 400 V Starting mode Direct starting
Rated current 4,4 A Insulation class H
Power input P1 2,3316 kW Degree of protection IP 68
Shaft power P2 1,8 kW Main cable
Starting current, direct starting A Cable type H07RNF
Starting current, star-delta A
MOTOR BODY
Materials
Casing CI FG 260 WITH 0.3% NiCuMo O RING NBR
IMPELLER CI FG 260 WITH 0.3% NiCuMo SHAFT SEAL Mech Seal Bellow-2Nos
MOTOR BODY CI FG 260 WITH 0.3% NiCuMo
FASTENERS SS 304
Weight 32 kg
Operating data Impeller type Vortex type impeller Impeller size 140 mm
Curve Tolerance
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 v / m/s
16 0,16
14 0,14
39,2%
12 0,12
40,2%
10 0,1
8 0,08
A1
6 0,06
4 0,04
2 0,02
0 0
P₂ / kW Shaft power P2
2,7
2,6
2,5
2,4
2,3
2,2
2,1
2
1,9
1,8
1,7
1,6
1,5
1,4
1,3
1,2
1,1
1
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q / m³/h
Note:
i.Performance is not guaranteed except for the rated point,
ii.Curves specified are as per Specific gravity and viscosity of water 1.0,
iii.Consider NPSH safety margin minimum of 0.5m.
To select the motor size, read the value of the Power curve at the duty point
In view of continuous developments, The information / Specifications / Descriptions / IIIustrations are subject to change without notice.
* The above model can be supplied with the auto coupling option. Suffix "P" in the respective model to denote the same.
Dimensions in mm
A 400
P3 210
P4 435