You are on page 1of 2

ECHOTRAC CV

ODOM

HYDROGRAPHIC SYSTEMS
You asked for more convenience and superior efficiency in

ECHOTRAC CV
ODOM your hydrographic survey tools. Odom answered.

With the Echotrac CV™, Odom delivers the perfect union of


flexibility and technology, viewed through a user-friendly
networked Windows interface, e-Chart. Alongside the advanced features and options that made the
Echotrac™ MKIII a stand-out product, the CV brings users to the next level by providing an optional third
acoustic channel. Whether it’s a side scan, bathymetric or a shallow subbottom investigation, the CV has
the flexibility to handle the task!

Buy Odom – invest in your peace of mind.

S P E C I F I C A T I O N S
Frequency LCD Display Help
• High band: 100 kHz – 1 MHz • 15 in TFT screen • The function of each parameter and it’s minimum
• Low band: 3.5 kHz – 50 kHz • High-Bright (500 NIT) and maximum values can be printed on the paper
• Internal data storage in XTF format chart. Also, a record of all parameter settings can
Output Power
on 40 GB hard disk be printed on the chart.
• High: 100 kHz – 1 kW RMS max 200 kHz – • Data transfer via Ethernet interface or
900 W RMS max, 750 kHz – 300 W RMS max Environmental Operating Temperature
USB flash drive
• Low: 12 kHz – 2 kW RMS max, 50 kHz – • 0° – 50° C, 5 – 90% relative humidity,
2 kW RMS max Sound Velocity non-condensing
• 1370 – 1700 m/s
Input Power Dimensions
• Resolution 1 m/s
• 110 or 220 V AC – 24 V DC 50 watts • 9 mm (3.5 in) H x 45 mm (17 in) W x
Transducer Draft Setting 300 mm (12.8 in) D
Resolution
• 0 – 15 m (0 – 50 ft)
• 0.01 m/0.1 ft Weight
Depth Display • 15.9 kg (35 lbs)
Accuracy
• On control PC and remote LCD display
• 0.01 m/0.10 ft +/- 0.1% of depth @ 200 kHz Options
• 0.10 m/0.30 ft +/- 0.1% of depth @ 33 kHz Clock • Third acoustic channel (multiple configurations)
• 0.18 m/0.60 ft +/- 0.1% of depth @ 12 kHz • Internal battery backed time, • Remote display
elapsed time and date clock • Side scan transducer – single or dual channel side
Depth Range
looking 200 kHz or 340 kHz for search and
• 0.2 – 200 m / 0.5 – 600 ft @ 200 kHz Annotation
reconnaissance
• 0.5 – 1600 m /1.5 – 5000 ft @ 33 kHz • Internal – date, time, GPS position • Built-in DGPS
• 1.0 – 6000 m /3.0 –20,000 ft @ 12 kHz • External – from RS232 or ethernet • Subbottom Array (3.5 kHz 4 element array with
Phasing Interfaces stainless steel mounting frame typical)
• Automatic scale change, 10%, 20%, 30% overlap • 4 x RS232 or 3 x RS232 and 1 x RS422
or manual • Inputs from external computer,
motion sensor, sound velocity
Printer
• Outputs to external computer, remote display
• High resolution 8 dot /mm (203 dpi), • Outputs with LCD chart – VGA video out
16 gray shades • Ethernet interface
• 216 mm (8.5 in) wide thermal paper or film • Heave – TSS1 or sounder sentence
• External ON/OFF switch
• Paper advance control Blanking
• 0 to full scale
Paper Speed
• 1 cm/min (0.5 in/min) to 22 cm/mm (8.5 in/min), Installation
Auto = one dot row advance for each Ping • Desktop or optional rack mount
and bulkhead mount
Software
• Echotrac control supplied
• e-Chart supplied with LCD configuration

HYDROGRAPHIC SYSTEMS

1450 Seaboard Avenue


Baton Rouge, Louisiana 70810-6261 USA
E-mail: email@odomhydrographic.com
www.odomhydrographic.com

4/01/08

ODOM HYDROGRAPHIC SYSTEMS, INC. (225) 769-3051 · (225) 766-5122 FAX

You might also like