1. A 25.

0-mL sample was treated with an excess of methiomeprazine and subsequently diluted
to 50.0 mL. At 480nm, the molar absorptivities of metal A (II) and metal B(III) are 5.3 x 10 3 and
3.96 x 103, respectively. At 635nm, the molar absorptivities of metal A (II) and metal B(III) are
8.1 x 102 and 1.2 x 104, respectively. Calculate the molar concentrations of metal A (II) and
metal B(III), in the sample if the diluted solution had an absorbance of 0.480 at 480 nm and
0.650 at 635 nm when measured in a 1.00-cm cell.

WRONG:
D

2. What is the absorptivity (ppm-1 cm-1) of a compound with a formula weight of 445 and molar
absorptivity of 8.455 x 103 M-1 cm-1?

WRONG:
D
(8.455x10^3) / 445 = 19000
19000 x 10^-6 = 0.019

3. An organic molecule, react with picric acid to form picrate complex, which absorb strongly at
359 nm (molar absorptivity = 1.25 × 104).  A 0.750 g of this substance was dissolved in water
and diluted to 100 mL. A 1-mL aliquot of this is diluted to 250 mL for measurement. If this final
solution exhibits an absorbance of 0.454 at 359 nm using a 1.00-cm cell, what is the formula
weight of the unknown molecule?

WRONG:
D
4. A solution containing 3.00 mg iron (as the thiocyanate complex) in 100mL was observed to
transmit 45.0% of the incident light compared to an appropriate blank. What is the absorbance
of the solution at this wavelength?

WRONG:
B

-log(0.45)=0.347

5. Which of the following is not part of UV-Vis spectrophotometers?


Nebulizer

6. The diagram given below is the representation of Fourier transform interferometer. Identify
the missing block in the block diagram.

Michelson Interferometer

7. Why is the computer necessary in Fourier Transform Spectrometer?


To process the detector output

8. It is the most popular detector used in UV- Visible spectrometry.


Photomultiplier Tube

9. Which of the following statements about infrared absorption is NOT correct?


The IR frequency should match the vibrational frequency of the molecule so that IR
radiation will be transmitted

10. Given the figure below, the spectral change as n increase in the molecule is classified as
Hypsochromic Effect

Bathochromic Effect

11. The following functional groups can act as auxochromes except


Cycloalkanes

12. Which of following techniques doesnt make use of a light source?


Mass Spectrometry

13. It can be considered as any form of radiant energy that is propagated as a transverse wave.
Electromagnetic Radiation

14. Which of the following is not true about Fourier Transform Infrared (FTIR) spectrometer?
Size has increased over the years

It is a spectrum in the time domain generated by making measurements of the


signal at many discrete positions of the moving mirror.
a. line spectrum
b. quantized light
c. interferogram
d. non-dispersive spectrum

Which of the following is correctly matched monochromator to type of


radiation?
a. CsI: visible light
b. fused silica: IR radiation
c. KBr: infrared radiation
d. glass prism: UV radiation
Which of the following compounds would poorly absorb UV light?
a. benzene
b. ethanol
c. copper sulfate
d. hexane

It states that the absorptive capacity of a dissolved substance is directly


proportional to its concentration in a solution, with the assumption that there is
a single pathlength for all rays passing through the sample.
a. Eadie-Hofstee law
b. Hooke's law
c. Lambert-Beer's law
d. Hanes-Woolf law