Datasheet Sun StorEdge™ 3510 FC Array On the Web sun.

com/storage

Sun StorEdge™ 3510 FC Array

Powerful, rack-dense, scalable, super-rugged Fibre Channel


RAID disk array

Spend your IT dollars wisely Do more for less with powerful, yet affordable enterprise-class high-density modular array.
Multi-host connectivity helps eliminate Good things come in small packages. The powerful Sun StorEdge™ 3510 FC array uses a high port
costly switches.
count modular, building-block approach to help reduce SAN costs by thousands of dollars. Up
Simply put, you can have your life back to six dual path or twelve single path servers can be connected to one dual controller RAID array
No more spending long hours configuring, tray without using costly external edge switches. With its highly intuitive management interface,
installing, reconfiguring, monitoring, this array is extremely easy to deploy, configure, manage, and monitor. Using cost effective
and diagnosing. Sets up in minutes. Time-
expansion trays, a RAID array can be scaled to 108 drives—that’s almost 16TB of raw capacity.
saving features help reduce administrative
overhead. A single, highly intuitive GUI With affordable enterprise-class features and functionality, the powerful, reliable, available,
provides local or remote control with ruggedized Sun StorEdge 3510 FC Array provides unparalleled outstanding value.
automatic alerting. Sun storage—providing you with comprehensive hardware, software, and services to solve
your business challenges enterprise-wide.
Save valuable space with unprecedented
density and scalability
Packs 1.7TB into a fully hot-swap redundant,
multi-port, multi-LUN, highly serviceable
2RU enclosure. RAID arrays can be quickly
scaled to over 15.7TB of raw capacity.
Space-saving trays pack over 30TB inside
a single cabinet.

Adapts to your unique requirements


Highly flexible arrays with hundreds of
possible configurations can be cost-matched
to most any application workload and data
criticality requirement.

Built tough to last for years


Designed to withstand harsh environ-
ments, the ruggedized array meets full
NEBS Level 3 certification and complies
with the air, land, and sea components
of the MIL-STD-810F specification.
Datasheet Sun StorEdge™ 3510 FC Array On the Web sun.com/storage

Sun StorEdge™ 3510 FC Array Specifications


Standard Interfaces Reliability, Availability, Serviceability (RAS)
Host Interface 2Gb Fibre Channel Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
Drives Dual-ported active- active 2Gb Fibre Channel; 3.5 in. low profile Hot-swap RAID controllers with battery-backed mirrored 1GB cache, (with dual RAID controllers)
Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
Supported drives 36GB 15k rpm; 73GB 10k rpm; 73GB 15k rpm; 146GB 10k rpm
Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
Maximum number of host ports Dual RAID controllers: 12x2Gb FC host ports (no expansion); Hot-swap, redundant electrically-isolated redundant cooling fans
8x2Gb FC host ports with expansion trays Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
Maximum cable length 250m
Maximum point-to-point length 250m Electrical Requirements
AC Voltage 100 to 240 VAC, single phase
Tray and RAID Array Storage Capacities AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
36GB 15k rpm HDDs 436GB max. raw capacity per 2U tray; AC Current per input 100 to 240 VAC (50 to 60 Hz) 5.0–7.1A
expandable to 3.9TB per RAID array (108 HDDs) DC Voltage –48 or –60 VDC, 18A
73GB 10k/15k rpm HDDs 876GB max. raw capacity per 2U tray; DC Power requirement –36 to –75 VDC
expandable to 7.8TB per RAID array (108 HDDs)
DC Current per input –48 or –60 VDC, 18A
146GB 10k rpm HDDs 1.72TB max. raw capacity per 2U tray;
expandable to 15.7TB per RAID array (108 HDDs)
Environment
Operating 5° C to 40° C (41° F to 104° F); 10% to 90% relative humidity to
RAID Controller Card
38° C, noncondensing; altitude: –30 to 3048 m (–100 to
RAID configurations per tray JBOD/Expansion (no controller); single RAID controller; 10,000 ft.); shock: 5.0 G, 11-ms, half-sine; vibration: 0.2 G, 5 to
dual (mirrored) RAID controllers 500 Hz, swept-sine; noise*: LWAD = 6.6 bels
RAID levels 0, 1, 0+1, 1+0, 3, 5, 3+0, and 5+0 Non-operating –40° C to 65° C (–40° F to 149° F); 0% to 90% relative humidity to
Max. LUNS Up to 1,024 per RAID array 27° C max. wet bulb, noncondensing; altitude: –30 to 12,192 m
Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array (–100 to 40,000 ft.); shock: 15.0 G, 11-ms, half-sine;
vibration: 1.0 G, 5-500 Hz, swept-sine
Cache size (read and write) 1GB per controller
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23° C
Cache battery backup Up to 72 hours
Cache write policy Write Back–default; Write Through–user configurable Regulations
Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer) Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE, GR-78-CORE),
Operating environments Sun Solaris™ Operating System v.8, 9, 10, x86 10; Microsoft MIL-STD-810F, ETSI EN 300 386
Windows NT EE 4.0/2000/2003 server; Red Hat Linux, Enterprise Meets or exceeds the following requirements:
Edition, 32-bit and 64-bit; Novell SuSE Linux Enterprise server 8 Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000,
Kernel 2.4.19- 64GB; U3 Kernel 2.4.21-138; U3 Kernel 2.6.5-7.97 IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15
Novell SuSE Linux 9; Novell NetWare 5.1, 6.0, 6.5; HP-UX 11.0 Class B, CISPR 22 55022:1998 Class B, ICES-003
and 11i; IBM-AIX 4.3.3 and 5.1L (32 and 64 bit)
Emission VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S-Mark
Included Management Sun StorEdge™ Configuration Service software
software support Sun StorEdge™ Diagnostic Reporter software Harmonics & Flicker IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
Immunity CSIPR 24 EN 55024
Supported Hardware
Supported hosts All Sun Enterprise™, Sun Netra™, and Sun Fire™ SPARC-based and
Dimensions and Weight
Sun Fire x86-based (Intel and AMD) servers; x86-based (Intel Height, Width, Depth H: 8.8 cm (3.5 in.), W: 44.7 cm (17.6 in.), D: 53.3 cm (21 in.)
and AMD) third-party servers; IBM RISC-based servers; HP RISC- Weight (fully populated) 22.7 kg (50.0 lb.)
based servers
Supported host bus adapters X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, Warranty
Sun Solaris (8, 9, 10) SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
Two year Sun two-year standard warranty, (1st year on site, 2nd year
Sun Solaris (x86 10) X9279A (Sun Fire V20Z and V40z servers) return to depot)
MS Windows/Red Hat Linux/ QLA23XX 2Gb FC PCI* Service Upgrades
SM
SunSpectrum service upgrades are available
Novell SuSE Linux/Novell NetWare
HP-UX and IBM-AIX Emulex LP9XXX 2Gb FC PCI* and compatible
Storage Area Network (SAN) Sun SAN 4.1 or greater
Get the details. For more information on this product, go to:
Fibre Channel configurations Fibre Channel arbitrated public, Fibre Channel private loop,
point-to-point, switched fabric www.sun.com/storage/workgroup/3000/3500/3510/
*Note: All non-Sun host bus adapters supported by third-party vendor.

Sun Microsystems, Inc. 4150 Network Circle, Santa Clara, CA 95054 USA Phone 1-800-555-9SUN or 1-650-960-1300 Web sun.com/storage

Sun Worldwide Sales Offices: Argentina +5411-4317-5600, Australia +61-2-9844-5000, Austria +43-1-60563-0, Belgium +32-2-704-8000, Brazil +55-11-5187-2100, Canada +905-477-6745, Chile +56-2-3724500, Colombia +571-629-2323
Commonwealth of Independent States +7-502-935-8411, Czech Republic +420-2-3300-9311, Denmark +45 4556 5000, Egypt +202-570-9442, Estonia +372-6-308-900, Finland +358-9-525-561, France +33-134-03-00-00, Germany +49-89-46008-0
Greece +30-1-618-8111, Hungary +36-1-489-8900, Iceland +354-563-3010, India–Bangalore +91-80-2298989/2295454; New Delhi +91-11-6106000; Mumbai +91-22-697-8111, Ireland +353-1-8055-666, Israel +972-9-9710500
Italy +39-02-641511, Japan +81-3-5717-5000, Kazakhstan +7-3272-466774, Korea +822-2193-5114, Latvia +371-750-3700, Lithuania +370-729-8468, Luxembourg +352-49 11 33 1, Malaysia +603-21161888, Mexico +52-5-258-6100
The Netherlands +00-31-33-45-15-000, New Zealand–Auckland +64-9-976-6800; Wellington +64-4-462-0780, Norway +47 23 36 96 00, People’s Republic of China–Beijing +86-10-6803-5588; Chengdu +86-28-619-9333
Guangzhou +86-20-8755-5900; Shanghai +86-21-6466-1228; Hong Kong +852-2202-6688, Poland +48-22-8747800, Portugal +351-21-4134000, Russia +7-502-935-8411, Saudi Arabia +9661 273 4567, Singapore +65-6438-1888
Slovak Republic +421-2-4342-94-85, South Africa +27 11 256-6300, Spain +34-91-596-9900, Sweden +46-8-631-10-00, Switzerland–German 41-1-908-90-00; French 41-22-999-0444, Taiwan +886-2-8732-9933, Thailand +662-344-6888
Turkey +90-212-335-22-00, United Arab Emirates +9714-3366333, United Kingdom +44-1-276-20444, United States +1-800-555-9SUN or +1-650-960-1300, Venezuela +58-2-905-3800, or online at sun.com/store

Information subject to change without notice. ©2005 Sun Microsystems, Inc. All rights reserved. Sun, Sun Microsystems, the Sun logo, The Network is the Computer, SunSpectrum, Sun StorEdge, Solstice DiskSuite, Sun Enterprise, Sun Netra, Sun
SUN™ Fire, and Solaris are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the United States and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC
International, Inc. in the United States and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. All other trademarks mentioned in this document are the property of their respective owners.
LFC1.8 Printed in USA 1/05 NWSPOD-10

You might also like