You are on page 1of 1

ACCESSORIES ORDER

Date : Blast Time : Location : Target RL : Blast Number :


24-Jul-2022 12:00 PIT RL 265 - RL 260 NHM/ENG/VII/01/2022 AREA A
Gosowong
No Description Unit Order SHOT PLAN Design For Drill Pattern

Geometry

1 Ho le Nu m b er s each 91

2 Diam et er mm 200

3 Av . Dep t h m 5.2

4 Bu r d en m 3.8

5 Sp acin g m 4.5

6 St em m in g m 2.20

7 Vo lu m e Bcm 8092

8 ANFO kg 2930

9 PF Pr o d u ct io n Ho le kg /b cm 0.36

10 Fir in g Tim e WITA 12:00

Accessories SINGLE BOOSTER

1 Bo o st er @ 200 g r /Cast Bo o st er p cs 91

2 IHD 500m s, 9m p cs

3 IHD 500m s, 6m p cs

4 Su r f ace Delay 17m s,12m p cs

5 Su r f ace Delay 25m s,12m p cs

6 Su r f ace Delay 42m s,12m p cs

7 Su r f ace Delay 67m s,12m p cs

8 Su r f ace Delay 109m s,12m p cs

9 Elect r o n ic Det o n at o r s, 15 m p cs

Others:

Improvement Order

1 Bo o st er 200 g r p cs

2 Fir in g Seq u en ce Nonel Remote Firing

3 Bo t t o m Plu g p cs For All Holes With


Hole Depth > 6 Meter

Hole ID Y X Z
A01 11480.3 4713.4 265.0
A02 11472.4 4712.6 5265.0
A03 11467.6 4674.0 5265.0
A04 11459.9 4653.8 5265.0
A05 11448.4 4706.2 5265.0

A06 11440.0 4702.6 5265.0


A07 11434.4 4649.6 5265.0
A08 11434.4 4649.6 5265.0