Solvent-free super strong
High-temperature acid and alkali resistant polymer

Product Overview
TYC-1302 solvent-free super strong high-temperature acid and alkali resistant polymer is an internal anticorrosive coating specially
designed for the pipe, tank, and pressure vessel of high-temperature acid and alkali, It has super strong adhesion, outstanding
-
high-temperature resistance to acid and alkali, abrasion resistant,and excellent resistance to H2S、CO2 and CL corrosion
performance. TYC-1302 can run for a long time at a temperature lower than 120℃ (248℉). It is mainly used as inner coating for
high-temperature and high-pressure pipe, fitting, separator,tank, and pressure vessel,The coating performance indexes meet the
requirements of SY/0457, SY/T6717 and NACE TM0185 standards
TYC-1302 can be also used as external anticorrosive coating material application for welded joint, repair, and special pipes such as
elbow etc. It meet the requirements of SY/06854-2012 standard, and can run for a long time at a temperature lower than 130℃ (266
℉).

Typical Coat Properties


Color(Base): yellow green Surface drying: 12h @ 25°C (77°F)
Nonvolatile content: Almost 100% (by weight) hard drying: 48h @ 25°C (77°F)
3
Density(20℃): 1.48 ± .05 g/ cm ((mixture) complete curing: 10d @ 25°C (77°F)
Packaging: 20kg Iron drum packaging, packaging is not recycled Theoretical coverage: 0.525kg/m2(350μm)
Mixing ratio: Base:Hardener =4:1(by weight)/3:1(by volume)
Shelf life *:Could storage 12 months under the temperature 35℃ (95℉) and 80 humidity
*Recommended to store under lower temperature and humidity conditions. Please do not store above 40℃.

Typical Coating Properties

Recommended Film Thickness : internal coating:500-800μm; external coating:350-500μm;

Test item Test method Acceptance criteria Result


coating smooth, no defects of bubbles, crease, tears
appearance visual inspection pass
etc.
Hardness(Shore D) ASTM D2240 80 Average 85
Impact Resistance Test SY/T0442-2010 Appendix F ≥6J 10J
adhesion GB/T5210 ≥8MPa 30MPa
Abrasion resistance GB/T1768@1kg/1000rcs-17wheel ≤120mg 40mg
1.5°flexibility(25℃) SY/T0442-2010 Appendix E no cracking pass
Abrasion resistance GB/T1768@1kg/1000rcs-17wheel ≤120mg pass
salt spray resistance ASTM-B117 3000h,pass pass
high pressure and
pH=12.5,NaOH in water,148℃,70MPa,16h
temperature alkali SY/T6717-2016 Appendix C pass
No Blistering, adhesion≥3A
Resistance Test
high pressure and Gas:100% CO2;
SY/T6717-2016 Appendix C pass
temperature acid Liquid:water: methylbenzene: kerosene =1:1:1,

北京天乙长科技发展有限公司
Beijing TYC Technologies Development Co., Ltd.
产品技术说明书
Technical Data Sheet
版本 Version:2.0

Resistance Test 107℃,35MPa,16h


No Blistering, adhesion≥3A
10%HCl in water,25℃,90d, No blistering pass
10%NaCl in water,25℃,90d, No blistering pass
Chemical Resistance 9%HCl+6%HF in water,25℃,90d, No blistering pass
API RP 5L7 Appendix 12
Test 5%HCl+10%H2SO4 in water,65℃,30d, No blistering pass
Crude oil,120℃,90d, No blistering pass
sewage of oil field, 95℃,90d, No blistering pass
-
PH2S 1.5 MPa, PCO2 0.5 MPa, CL 100g/L,15MPa、
H2S、CO2、CL -
NACE TM0185-2006 120℃,water,168h。 pass
Resistance Test
No Blistering

General Application Parameters


Surface treatment: thoroughly remove oil, dirt and other attachments on pipe inner surface. Blasting at room temperature and
relative humidity less than 90%. Blast cleaning to achieve a minimum surface cleanliness of Sa 2½ and The
anchor profile shall be 45~75 mu
Mixing ratio: Base:Hardener =3:1(by volume);Base:Hardener =4:1(by weight)
Application method: Recommend dual high-pressure airless spraying, Brushing or roller painting is suitable for welded joint,
repair, and special pipes.
Recoating period: At room temperature and relative humidity less than 90%. The recoating period is much more 24h, but less
than 5d.
Notice: Avoid painting when the temperature is below 10℃ or the humidity is over 85%.

Safety and health


This product has no organic solvents and is non-flammable. However, special care should be taken when accident disposal
Avoid contact with skin and eyes, preferably with safety glasses and protective gloves.
During spraying must wear ventilation mask to protect respiratory organs from powder damage.
If the coat is splashed on the skin, please immediately wash with cleaning agent, soap and water. If be splashed into eyes please immediately
flush with water and seek medical advice.
Good ventilation must be maintained on the construction site. Strong ventilation must be provided for narrow or airtight construction area.
The construction site must be equipped with a certain amount of fire equipment.
This product should not pour into the sewage system.
Please pay attention to the safety information on the package label. In addition, please comply with national or local governmental safety
regulations.

Add. Notes

The relevant data provided in this manual is acquired in standard conditions, during actual application, the coating data may be different due to environmental

conditions, surface condition of base material and application factors, resulting the differences of coating performance or other problem, so it should adjust relevant

technology according to site condition.

If apply the products beyond mentioned in this manual’s functions or suggestions, please consult our technical department, unless we issue a specific written consent of

the file. Otherwise, all responsibilities shall be bored by clients.


Our company reserves the right to revise the product specification without notice , If there is any changes of above dada, please be subject to our

北京天乙长科技发展有限公司
Beijing TYC Technologies Development Co., Ltd.
产品技术说明书
Technical Data Sheet
版本 Version:2.0
company’s latest instructions.

北京天乙长科技发展有限公司
Beijing TYC Technologies Development Co., Ltd.

You might also like