Professional Documents
Culture Documents
Sx> 0 Srelev>0
Qqualmeas+Qaulamin>0 Qrxlevmes+Qrxlevmin
where Sx is Squal.
Squla< Sintrasearch
Qaulameas+Qqualmin< Sintrasearch
3g to 2g/3g Reselection
1-Measurement
2-RANKING
EcNO
0
-1
-2
-3
-4 No Reselection
-5 Stat Intrafrequency measurement
-6
-7-8
-9 Start inerfrequeny measuremnt
-10
-11
-12
-13 start GSM measurement
-14
-15
.
.
.
.
.
-30
3g ecno< Qqualmin+Sintrasearch
-13< -18+14
-13<-4
IF want to tight on cell1(3g) change change Sintrasearch 14 to 10.... on serving
cell. cahnge to minimum value
if you want to tight on cell1(3g) change Qhyst2 0 to 4.... increasing value but
Qhyst in cell level parameter.
1st ranking:
Rs=EcNo+ qHyst1( 0 to 40)
Rs=-14+8=-7
Rn=-12-(10)=-22
Rn=Rxlev-qoffset1s
second ranking:
you can also change on cell2 that cell1 not reselect cell 1 change qoffset2 0 to
6....
Rn=-12-(10)=-22
qHYST1 AND QOffset1 is RACp based and its for both WCDMA and GSM.