You are on page 1of 35

GLOBAL

AORTIC
PRODUCT
CATALOGUE

Endurant™ II/IIs Valiant Navion™ Heli-FX ™

TourGuide™ Sentrant™ Reliant™

C201806182aEE Aortic Catalog.indd 1 5/20/19 4:10 PM


TABLE OF CONTENTS

02 Endurant II/IIs ™

AAA Stent Graft System

28 Talent Occluder ™

Endurant™ Talent™ with Occluder Delivery System


II/IIs Occluder

30 Valiant Navion ™

Thoracic Stent Graft System

42 Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

Valiant Valiant™
Navion™ Captivia™ Heli-FX ™

56 Heli-FX ™

EndoAnchor™ System

58 TourGuide ™

Steerable Sheath

TourGuide™ Sentrant™ Reliant™ 60 Sentrant ™

Introducer Sheath with Hydrophilic Coating

62 Reliant ™

Stent Graft Balloon Catheter

UC201806182aEE Aortic Catalog.indd 2-3 5/20/19 4:10 PM


ENDURANT II/IIs
Endurant II/IIs ™

AAA Stent Graft System

FEATURES†

Endurant™ IIs System Expands Anatomical


Customization Options
A three-piece system that leverages the proven design
of the Endurant™ II abdominal stent graft
Enables in-situ sizing with select ipsilateral limbs, allowing a
3-5 stent overlap for adjustment during case
Allows easier pre-case planning to simplify sizing

Low Profile and Easy Access


Low profile and hydrophilic coating enhance access
and trackability
Flexible, kink-resistant delivery system facilitates stent
graft delivery

Complete Conformability, Optimal Seal


M-shaped proximal stents provide wall apposition and minimize
infolding for a short sealing zone in the infrarenal aorta
Laser cut suprarenal stent anchor pins provides secure fixation
to mitigate migration
Spacing between limb stents optimized to conform to anatomy
to reduce kinking

Total Control Provides Consistent Precision


Tip capture mechanism allows for precise
positioning and intraoperative adjustments PROVEN
Backend thumb wheel provides controlled release
of the suprarenal stent and anchor pins SOLUTIONS
Improved radiopacity provides increased visibility‡
Four proximal markers assist in accurate deployment
AS VARIED
e- shaped marker assists with A/P orientation AS YOUR
Durable Design, Dependable Performance
Ultra-high molecular weight polyethylene sutures are
PATIENTS
three times stronger than surgical sutures
High-density multifilament polyester graft material
provides low porosity
Electropolished nitinol stents improve fatigue resistance


Test data on file at Medtronic. Bench test results may not be indicative
of clinical performance.

Contralateral gate marker.
2 3

UC201806182aEE Aortic Catalog.indd 4-5 5/20/19 4:10 PM


Endurant II/IIs ™

AAA Stent Graft System

ENDURANT ™ II/IIs SYSTEM PRODUCT CODE DESCRIPTION ENDURANT ™ II SYSTEM BIFURCATIONS


Product Code
ET B F 23 13 C 124 EE 18
Proximal Distal Total Catheter
Catheter Outer Graft Graft Distal Covered Delivery Outer
Diameter Diameter Diameter Design Length System Diameter
(mm) (mm) (mm) (Fr)
Delivery System ETBF 23 13 C 124 EE 18
EE - Endurant™ II System
ETBF 23 13 C 145 EE 18
Total Covered Length ETBF 23 13 C 166 EE 18
ETBF 23 16 C 124 EE 18
Distal Design
ETBF 23 16 C 145 EE 18
C - Closed Web
ETBF 23 16 C 166 EE 18
Distal Graft Diameter
ETBF 25 13 C 124 EE 18
Proximal Graft Diameter ETBF 25 13 C 145 EE 18
ETBF 25 13 C 166 EE 18
Proximal Design
ETBF 25 16 C 124 EE 18
F - FreeFlo
W- Open Web ETBF 25 16 C 145 EE 18
ETBF 25 16 C 166 EE 18
Device Configuration
B - Bifurcations ETBF 28 13 C 124 EE 18
L - Limbs ETBF 28 13 C 145 EE 18
E - Iliac Extension
C - Extensions & Cuff s ETBF 28 13 C 166 EE 18
T - Abdominal Tubes ETBF 28 16 C 124 EE 18
U - Aorto-uni-iliac (AUI)
ETBF 28 16 C 145 EE 18
Product Name ETBF 28 16 C 166 EE 18
ET - Endurant™ II System
ETBF 28 20 C 124 EE 18
ES - Endurant™ IIs System
ETBF 28 20 C 145 EE 18
ETBF 28 20 C 166 EE 18
ENDURANT IIs SYSTEM BIFURCATIONS

ETBF 32 16 C 124 EE 20
Product Code
ETBF 32 16 C 145 EE 20
Proximal Distal Total Catheter
Graft Graft Distal Covered Delivery Outer ETBF 32 16 C 166 EE 20
Diameter Diameter Design Length System Diameter
(mm) (mm) (mm) (Fr) ETBF 32 20 C 124 EE 20
ESBF 23 14 C 103 EE 18 ETBF 32 20 C 145 EE 20
ESBF 25 14 C 103 EE 18 ETBF 32 20 C 166 EE 20

ESBF 28 14 C 103 EE 18 ETBF 36 16 C 145 EE 20

ESBF 32 14 C 103 EE 20 ETBF 36 16 C 166 EE 20

ESBF 36 14 C 103 EE 20 ETBF 36 20 C 145 EE 20


ETBF 36 20 C 166 EE 20

44 5

UC201806182aEE Aortic Catalog.indd 6-7 5/20/19 4:10 PM


Endurant II/IIs ™

AAA Stent Graft System

LIMBS† ILIAC EXTENSIONS


Product Code Product Code
Total Total
Proximal Distal Total Catheter Contralateral Ipsilateral Proximal Graft Distal Graft Total Covered Catheter
Graft Graft Distal Covered Delivery Outer Distal Delivery
Covered Covered Diameter Diameter Length Outer
Diameter Diameter Design Length System Diameter Length Length Design System
(mm) (mm) (mm) Diameter (Fr)
(mm) (mm) (mm) (Fr) with EII/EIIs with EIIs
§
Bifurcated

Bifurcated ETEW 10 10 C 82 EE 14
ETLW 16 10 C 82 EE 14 136 155 ETEW 13 13 C 82 EE 14
ETLW 16 10 C 93 EE 14 147 166 ETEW 20 20 C 82 EE 16
ETLW 16 10 C 124 EE 14 178 177–197 ETEW 24 24 C 82 EE 16
ETLW 16 10 C 156 EE 16 210 209–229 ETEW 28 28 C 82 EE 18
ETLW 16 10 C 199 EE 16 253 252–272
AORTIC EXTENSIONS
ETLW 16 13 C 82 EE 14 136 155
Product Code
ETLW 16 13 C 93 EE 14 147 166
ETLW 16 13 C 124 EE 14 178 177–197 Proximal Graft Distal Graft Total Covered Catheter
Distal Delivery
Diameter Diameter Length Outer
ETLW 16 13 C 156 EE 16 210 209–229 Design System
(mm) (mm) (mm) Diameter (Fr)
ETLW 16 13 C 199 EE 16 253 252–272 ETCF 23 23 C 49 EE 18
ETLW 16 16 C 82 EE 14 136 135–155 ETCF 25 25 C 49 EE 18
ETLW 16 16 C 93 EE 14 147 146–166 ETCF 28 28 C 49 EE 18
ETLW 16 16 C 124 EE 14 178 177–197 ETCF 32 32 C 49 EE 20
ETLW 16 16 C 156 EE 16 210 209–229 ETCF 36 36 C 49 EE 20
ETLW 16 16 C 199 EE 16 253 252–272
ABDOMINAL TUBES
ETLW 16 20 C 82 EE 16 136 155
Product Code
ETLW 16 20 C 93 EE 16 147 166
Proximal Graft Distal Graft Total Covered Catheter
ETLW 16 20 C 124 EE 16 178 177–197 Distal Delivery
Diameter Diameter Length Outer
Design System
ETLW 16 20 C 156 EE 16 210 209–229 (mm) (mm) (mm) Diameter (Fr)
ETLW 16 20 C 199 EE 16 253 252–272 ETTF 23 23 C 70 EE 18
ETLW 16 24 C 82 EE 16 136 155 ETTF 25 25 C 70 EE 18
ETLW 16 24 C 93 EE 16 147 166 ETTF 28 28 C 70 EE 18
ETLW 16 24 C 124 EE 16 178 177–197 ETTF 32 32 C 70 EE 20
ETLW 16 24 C 156 EE 16 210 209–229 ETTF 36 36 C 70 EE 20
ETLW 16 24 C 199 EE 16 253 252–272 AUI
ETLW 16 28 C 82 EE 16 136 155
Product Code
ETLW 16 28 C 93 EE 16 147 166
Proximal Graft Distal Graft Total Covered Catheter
ETLW 16 28 C 124 EE 16 178 177–197 Distal Delivery
Diameter Diameter Length Outer
Design System
ETLW 16 28 C 156 EE 16 210 209–229 (mm) (mm) (mm) Diameter (Fr)
ETLW 16 28 C 199 EE 16 253 252–272 ETUF 23 14 C 102 EE 18

The limb mates with the AUI stent graft on the ipsilateral side. ETUF 25 14 C 102 EE 18

These calculations assume the minimum 30 mm overlap between the bifurcated stent graft and the ETUF 28 14 C 102 EE 18
contralateral iliac limb per the Endurant™ II Stent Graft System Instructions for Use. When using the 124 mm
length bifurcated stent graft, subtract 10 mm from Total Contralateral Covered Length with Bifurcated. ETUF 32 14 C 102 EE 20
§
The 3-5 stent overlap is available only with select limbs. Please refer to the Instructions for Use for more ETUF 36 14 C 102 EE 20
information.

6 7

UC201806182aEE Aortic Catalog.indd 8-9 5/20/19 4:10 PM


Endurant II/IIs ™

AAA Stent Graft System

PLACEMENT AND SIZING GUIDELINES Each Endurant™ II/Endurant™ IIs AAA stent graft must be ordered
in a size that is appropriate to fit the patient’s anatomy. Proper
Use the proximal radiopaque markers to position
sizing of the Endurant™ II/Endurant™ IIs AAA stent graft is the
the top edge of the graft material.
responsibility of the physician. The following suggestions for stent
graft diameters are based on vessel inner wall measurements.
e-SHAPED MARKER ASSISTS
WITH A/P ORIENTATION
BIFURCATIONS, AUI AND AORTIC EXTENSIONS
Recommended
Native Vessel (mm) Endurant™ II System
Diameter (mm)
Standard EVAR† ChEVAR‡
19 – 20 n/a 23

21 – 22 19-20 25

23 – 25 21-23 28

26 – 28 24-26 32

29 – 32 27-30 36

ILIAC EXTENSIONS
Recommended
Native Vessel (mm) Endurant™ II System
Diameter (mm)

RADIOPAQUE MARKERS 8–9 10


10 –11 13
15 –18 20
For the contralateral side: The radiopaque markers at the proximal 19 –22 24
limb should be aligned with the radiopaque markers at the flow 23 –25 28
divider of the Endurant™ II system or Endurant™ IIs system bifurs.
LIMBS
Recommended
For the ipsilateral side: Depending on the limb configuration used, Native Vessel (mm) Endurant™ II System
the radiopaque markers at the proximal end of the limb should be Diameter (mm)
aligned to the distal radiopaque marker on the ipsilateral leg or the 8–9 10
flow divider marker of the Endurant™ IIs system bifur. Select limbs will 10 –11 13
allow a 3-5 stent overlap adjustment during the case. Please refer to 12 –14 16
the Instructions for Use for more information as needed. 15 –18 20
19 –22 24
23 –25 28


EVAR: Bifurs, Cuff, AUI, Tube Configuration

ChEVAR Indication not approved globally. Check local regulatory status.
For complete product information visit www.medtronic.com/manuals. Consult instructions
for use at this website. Manuals can be viewed using a current version of any major internet
browser. For best results, use Adobe Acrobat® Reader with the browser.
Adobe and Acrobat reader are registered trademarks of Adobe Systems incorporated
in the United States and/or other countries.

8 9

UC201806182aEE Aortic Catalog.indd 10-11 5/20/19 4:10 PM


Endurant II/IIs ™

AAA Stent Graft System

COMPONENT PLACEMENT GUIDE†


ENDURANT™ II SYSTEM ENDURANT™ IIs SYSTEM BIFURCATED
23, 25, 28, PROXIMAL
32, 36 mm MARKERS

BIFURCATED LIMBS
23, 25, 28, PROXIMAL
32, 36 mm PROXIMAL
MARKERS MARKERS

LIMBS
PROXIMAL 16 mm
MARKERS ‡

GRAFT 103 mm
BIFURCATED
LIMBS
16 mm PROXIMAL
MARKERS 16 mm

82, 93, 124, 156, 199 mm


BIFURCATED GRAFT

ALIGN MARKERS

LIMBS
124†, 145, 166 mm

14
mm

12, 14 14
mm mm

10, 13,
82, 93, 124, 156, 199 mm

16, 20, 24,

82, 93, 124, 156, 199 mm


28 mm
LIMBS

LIMBS
13, 16,
20 mm

DISTINCT RADIOPAQUE MARKERS

• Radiopaque markers

• e-shaped proximal markers

— Internal ring marker—only seen under fluoroscopy



Reference product codes for available size combinations.

The 3-5 stent overlap is available only with select limbs.
Please refer to the Instructions for Use for more information.
10, 13, 10, 13,
16, 20, 24, 16, 20, 24,
28 mm 28 mm

10
10 11

UC201806182aEE Aortic Catalog.indd 12-13 5/20/19 4:10 PM


Endurant II/IIs ™

AAA Stent Graft System

COMPONENT PLACEMENT GUIDE

AUI
23, 25, 28, PROXIMAL AORTIC
32, 36 mm MARKERS EXTENSION ILIAC
PROXIMAL EXTENSION
MARKERS PROXIMAL
MARKERS

LIMBS 23, 25, 28,


PROXIMAL 32, 36 mm 10, 13, 20,
MARKERS ‡ 24, 28 mm

16 mm

AUI GRAFT
102 mm

ILIAC EXTENSION ‡
AORTIC EXTENSION /
ABDOMINAL TUBE ‡

82 mm
49, 70 mm
ALIGN MARKERS

14
mm
23, 25, 10, 13,
28, 32, 20, 24,
28 mm
82, 93, 124, 156, 199 mm

36 mm
LIMBS†

DISTINCT RADIOPAQUE MARKERS

• Radiopaque markers

• e-shaped proximal markers

† The limb mates with the AUI stent graft on the


ipsilateral side.

10, 13, Requires minimum 3 stent overlap. See Instructions for Use
16, 20, 24, for more information.
28 mm

12 13

UC201806182aEE Aortic Catalog.indd 14-15 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

PROXIMAL
23, 25, 28,
32, 36 mm DIAMETERS
ENDURANT ™ II SYSTEM BIFURCATIONS–STRAIGHT LIMBS
Product Code

Proximal Distal Total Graft Dimensions


Graft Graft Distal Covered Delivery (mm)
Diameter Diameter Design Length System
(mm) (mm) (mm) A B C D

ETBF 23 13 C 124 EE 12 40 74 25
ETBF 23 13 C 145 EE 12 50 84 25
ETBF 23 13 C 166 EE 12 50 84 25
B ETBF 25 13 C 124 EE 14 40 74 27
ETBF 25 13 C 145 EE 14 50 84 27
C ETBF 25 13 C 166 EE 14 50 84 27
ETBF 25 16 C 124 EE 14 40 74 30
TOTAL COVERED LENGTH

D ETBF 25 16 C 145 EE 14 50 84 30
ETBF 25 16 C 166 EE 14 50 84 30
ETBF 28 13 C 124 EE 14 40 74 27
ETBF 28 13 C 145 EE 14 50 84 27
ETBF 28 13 C 166 EE 14 50 84 27
A
ETBF 28 16 C 124 EE 14 40 74 30
ETBF 28 16 C 145 EE 14 50 84 30
ETBF 28 16 C 166 EE 14 50 84 30
ETBF 32 16 C 124 EE 14 40 74 30
ETBF 32 16 C 145 EE 14 50 84 30
ETBF 32 16 C 166 EE 14 50 84 30
ETBF 36 16 C 145 EE 14 50 84 30
ETBF 36 16 C 166 EE 14 50 84 30

13, 16 mm

ENDURANT ™ II SYSTEM BIFURCATIONS–STRAIGHT LIMBS

14 15

UC201806182aEE Aortic Catalog.indd 16-17 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

23, 28, PROXIMAL


32, 36 mm DIAMETERS

ENDURANT ™ II SYSTEM BIFURCATIONS–FLARED LIMBS


Product Code

Proximal Distal Total Graft Dimensions


Graft Graft Distal Covered Delivery (mm)
Diameter Diameter Design Length System
(mm) (mm) (mm) A B C D E F

ETBF 23 16 C 124 EE 12 40 74 25 10 30
B ETBF 23 16 C 145 EE 12 50 84 25 10 40
ETBF 23 16 C 166 EE 12 50 84 25 10 60
C ETBF 28 20 C 124 EE 14 40 74 30 10 30
ETBF 28 20 C 145 EE 14 50 84 30 10 40
TOTAL COVERED

ETBF 28 20 C 166 EE 14 50 84 30 10 60
D
LENGTH

ETBF 32 20 C 124 EE 14 40 74 30 10 30
ETBF 32 20 C 145 EE 14 50 84 30 10 40
ETBF 32 20 C 166 EE 14 50 84 30 10 60

E A ETBF 36 20 C 145 EE 14 50 84 30 10 40
ETBF 36 20 C 166 EE 14 50 84 30 10 60

16,
20 mm

ENDURANT ™ II SYSTEM BIFURCATIONS-FLARED LIMBS

16 17

UC201806182aEE Aortic Catalog.indd 18-19 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

PROXIMAL
23, 25, 28, DIAMETERS
32, 36 mm

ENDURANT ™ IIs SYSTEM BIFURCATIONS


Product Code
Proximal Distal Total Graft Dimensions
Graft Graft Distal Covered Delivery (mm)
Diameter Diameter Design Length System
(mm) (mm) (mm) A B C D
B
ESBF 23 14 C 103 EE 14 50 84 28
ESBF 25 14 C 103 EE 14 50 84 28
TOTAL COVERED

ESBF 28 14 C 103 EE 14 50 84 28
C
LENGTH

ESBF 32 14 C 103 EE 14 50 84 28
D ESBF 36 14 C 103 EE 14 50 84 28

14 mm

ENDURANT ™ IIs SYSTEM BIFURCATIONS

18 19

UC201806182aEE Aortic Catalog.indd 20-21 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

TAPERED LIMBS STRAIGHT LIMBS


Product Code Product Code

Proximal Distal Total Graft Proximal Distal Total


Graft Graft Distal Covered Delivery Dimensions Graft Graft Distal Covered Delivery
Diameter Diameter Design Length System (mm) Diameter Diameter Design Length System
(mm) (mm) (mm) (mm) (mm) (mm)
A B
ETLW 16 16 C 82 EE
ETLW 16 10 C 82 EE 20 30
ETLW 16 16 C 93 EE
ETLW 16 10 C 93 EE 20 40
ETLW 16 16 C 124 EE
ETLW 16 10 C 124 EE 20 40
ETLW 16 16 C 156 EE
ETLW 16 10 C 156 EE 20 72
ETLW 16 16 C 199 EE
ETLW 16 10 C 199 EE 20 115
ETLW 16 13 C 82 EE 10 30
ETLW 16 13 C 93 EE 10 40
PROXIMAL
ETLW 16 13 C 124 EE 10 40 16 mm DIAMETER
ETLW 16 13 C 156 EE 10 72
ETLW 16 13 C 199 EE 10 115

16 mm PROXIMAL
DIAMETER

TOTAL COVERED
LENGTH
TOTAL COVERED

A
LENGTH

10, 16 mm
13 mm

TAPERED LIMBS STRAIGHT LIMBS


20 21

UC201806182aEE Aortic Catalog.indd 22-23 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

PROXIMAL FLARED LIMBS


16 mm DIAMETER
Product Code
Proximal Distal Total Graft
Graft Graft Distal Covered Delivery Dimensions
Diameter Diameter Design Length System (mm)
(mm) (mm) (mm) A B
ETLW 16 20 C 82 EE 10 30
ETLW 16 20 C 93 EE 10 40
ETLW 16 20 C 124 EE 10 40
ETLW 16 20 C 156 EE 10 40
ETLW 16 20 C 199 EE 10 40
TOTAL COVERED

ETLW 16 24 C 82 EE 20 30
LENGTH

ETLW 16 24 C 93 EE 20 40
ETLW 16 24 C 124 EE 20 40
A
ETLW 16 24 C 156 EE 20 40
ETLW 16 24 C 199 EE 20 40
ETLW 16 28 C 82 EE 20 30
ETLW 16 28 C 93 EE 20 40
B
ETLW 16 28 C 124 EE 20 40
ETLW 16 28 C 156 EE 20 40
ETLW 16 28 C 199 EE 20 40

20, 24, 28 mm

FLARED LIMBS

22 23

UC201806182aEE Aortic Catalog.indd 24-25 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

ILIAC EXTENSIONS AUI


Product Code Product Code

Proximal Distal Total Proximal Distal Total Graft


Graft Graft Distal Covered Delivery Graft Graft Distal Covered Delivery Dimensions
Diameter Diameter Design Length System Diameter Diameter Design Length System (mm)
(mm) (mm) (mm) (mm) (mm) (mm) A B
ETEW 10 10 C 82 EE ETUF 23 14 C 102 EE 30 40
ETEW 13 13 C 82 EE ETUF 25 14 C 102 EE 30 40
ETEW 20 20 C 82 EE ETUF 28 14 C 102 EE 30 40
ETEW 24 24 C 82 EE ETUF 32 14 C 102 EE 30 40
ETEW 28 28 C 82 EE ETUF 36 14 C 102 EE 30 40

23, 25, 28, PROXIMAL


10, 13, PROXIMAL 32, 36 mm DIAMETERS
20, 24, DIAMETERS
28 mm
TOTAL COVERED
LENGTH

TOTAL COVERED
A

LENGTH
B

10, 13,
20, 24,
28 mm 14 mm

ILIAC EXTENSIONS AUI

24 25

UC201806182aEE Aortic Catalog.indd 26-27 5/20/19 4:11 PM


Endurant II/IIs ™

AAA Stent Graft System

AORTIC EXTENSIONS ABDOMINAL TUBES


Product Code Product Code

Proximal Distal Total Proximal Distal Total


Graft Graft Distal Covered Delivery Graft Graft Distal Covered Delivery
Diameter Diameter Design Length System Diameter Diameter Design Length System
(mm) (mm) (mm) (mm) (mm) (mm)

ETCF 23 23 C 49 EE ETTF 23 23 C 70 EE
ETCF 25 25 C 49 EE ETTF 25 25 C 70 EE
ETCF 28 28 C 49 EE ETTF 28 28 C 70 EE
ETCF 32 32 C 49 EE ETTF 32 32 C 70 EE
ETCF 36 36 C 49 EE ETTF 36 36 C 70 EE

23, 25, 28, PROXIMAL


32, 36 mm DIAMETERS
23, 25, 28, PROXIMAL
32, 36 mm DIAMETERS
TOTAL COVERED

TOTAL COVERED
LENGTH

LENGTH
23, 25, 28,
32, 36 mm

23, 25, 28,


32, 36 mm

AORTIC EXTENSIONS ABDOMINAL TUBES

26 27

UC201806182aEE Aortic Catalog.indd 28-29 5/20/19 4:11 PM


Talent Occluder

with Occluder Delivery System

FEATURES
TALENT ™ OCCLUDER
Double spring configuration securely anchors in the iliac artery to

TALENT
seal the lumen and to prevent retrograde blood flow. Product Code

Proximal/
Distal Total Catheter
COMPONENT PLACEMENT GUIDE Diameter Length Diameter
(mm) (mm) (Fr)
PRODUCT CODE DESCRIPTION
OCL 8 31 17.5
OCL 8 31 17.5
OCL 10 31 17.5
OCL 12 31 17.5
OCL 14 33 17.5
OCL 16 33 17.5
Catheter Diameter OCL 18 33 17.5
OCL 20 35 17.5
Total Length
OCL 22 35 17.5
OCL 24 35 17.5
Proximal / Distal Diameter

Device Confi guration OCCLUDER SYSTEM COMPONENT


TALENT™ OCCLUDER

OCL - Occluder Suggested


Native
31–35 mm

Stent Graft Oversizing


Vessel
Diameter (mm)
(mm)
(mm)
19–20 24 4–5
18 22 4
16–17 20 3–4
14–15 18 3–4
13 16 3
11–12 14 2–3
9–10 12 2–3
7–8 10 2–3
8–24 mm
6 8 2

Radiopaque markers

28 29

UC201806182aEE Aortic Catalog.indd 30-31 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

The Freedom to Do More COMPONENT GUIDE

Low profile, easy-to-use delivery system designed


for expanded access with smooth navigation
20–46 mm 25–46 mm
FEATURES 10 mm 10 mm 20–46 mm 25–46 mm
6 or 7 6 or 7
peaks peaks
Delivery System

VALIANT NAVION
Tip Capture: for controlled delivery and deployment on
both FreeFlo and CoveredSeal configurations

COVEREDSEAL STRAIGHT

COVEREDSEAL TAPERED
Designed for simplified navigation: flexible, kink-resistant

FREEFLO STRAIGHT

FREEFLO TAPERED

186, 200 & 207 mm


hydrophilic-coated catheter

173 & 185 mm


59-229 mm

52-223 mm
Shorter tapered tip designed to decrease vessel impact

Stent Graft
Multi-filament thoracic graft material based on Endurant™
stent graft yarn designed for flexibility and superior
permeability resistance
Aligned stent peaks and valleys designed for increased
flexibility throughout the stent graft
Increased distance between stents designed to optimize 20–46 mm 20-40 mm 20–46 mm 20-40 mm
migration resistance & conformability

Proven Platforms
Leverages proven design of the Valiant™ and Endurant™
stent graft system platforms DISTINCT RADIOPAQUE MARKER

100K+ thoracic and 300K abdominal patients treated † • Spherical RO Marker

Over 20 years of endovascular experience with deep


clinical history


Data on file at Medtronic.

30 31

UC201806182aEE Aortic Catalog.indd 32-33 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

Each Valiant Navion™ thoracic Aneurysms or PAU Dissection Blunt Thoracic Aortic Injury
stent graft device must be Suggested Suggested Suggested
Native Native Native
ordered in a size appropriate to Vessel
Stent Graft Oversizing
Vessel
Stent Graft Oversizing
Vessel
Stent Graft Oversizing
Diameter (mm) Diameter (mm) Diameter (mm)
fit the patient’s anatomy. Proper (mm)
(mm)
(mm)
(mm)
(mm)
(mm)
sizing of the Valiant Navion™ 16 20 4 19 20 1 16 20 4
thoracic stent graft is the 17 20 3 20 22 2 17 20 3
responsibility of the physician. 18 22 4 21 22 1 18 22 4
19 22 3
19 22 3 22 22 0
Aneurysms, Penetrating 20 22 2
20 25 5 23 25 2 20 25 5
Ulcers (PAU): 21 25 4 24 25 1 21 25 4
Oversize the aortic portion of 22 25 3 25 25 0 22 25 3
the stent graft by 3 to 7 mm, 23 28 5 26 28 2 23 25 2
as appropriate for the patient. 24 28 4 27 28 1 23 28 5
The following table is provided 25 28 3 28 28 0 24 28 4
25 28 3
as a guideline. 26 31 5 29 31 2
26 28 2
27 31 4 30 31 1 26 31 5
Dissection: 28 31 3 31 34 3 27 31 4
Do not oversize the stent graft 28 34 6 32 34 2 28 31 3
more than 10% of the healthy 29 34 5 33 34 1 29 31 2
aorta nominal diameter. The 30 34 4 34 37 3 28 34 6
29 34 5
following table is provided 31 34 3 35 37 2
30 34 4
as a guideline. 30 37 7 36 37 1
31 34 3
31 37 6 37 40 3 32 34 2
For Additional Sections: 32 37 5 38 40 2 30 37 7
When the stent graft junction is 33 37 4 39 40 1 31 37 6
located within the aneurysmal 33 40 7 39 43 4 32 37 5
34 40 6 40 43 3 33 37 4
sac or is not supported by tissue, 34 37 3
35 40 5 41 43 2
6 mm oversizing between 35 37 2
36 40 4 42 43 1
the primary component 33 40 7
36 43 7 42 46 4 34 40 6
and additional section is 37 43 6 43 46 3 35 40 5
recommended. In the case when 38 43 5 44 46 2 36 40 4
a 20 mm stent graft is used as an 39 43 4 45 46 1 37 40 3
outside component, the diameter 39 46 7 38 40 2
36 43 7
of the inside component should 40 46 6
37 43 6
be oversized by 5 mm relative to 41 46 5
38 43 5
the outside component. 42 46 4 39 43 4
When the stent graft junction 40 43 3
41 43 2
is supported by tissue (e.g., 39 46 7
dissections), the stent graft 40 46 6
should be oversized relative to 41 46 5
the supporting native vessel. 42 46 4
43 46 3
44 46 2
32 33

UC201806182aEE Aortic Catalog.indd 34-35 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

VALIANT NAVION™ SYSTEM FREEFLO STRAIGHT


PRODUCT CODE DESCRIPTION Product Code
VN M C 22 22 C 100 TE 22 Proximal Distal Stent Graft Catheter
Graft Graft Covered Outer
Diameter Diameter Length Diameter
(mm) (mm) (mm) (Fr)
VNMF 20 20 C 96 TE 18
VNMF 22 22 C 96 TE 18
Catheter Outer
Diameter VNMF 22 22 C 185 TE 18
VNMF 25 25 C 96 TE 18
VNMF 25 25 C 185 TE 18
Delivery System
VNMF 28 28 C 97 TE 20
TE - Thoracic VNMF 28 28 C 174 TE 20
VNMF 31 31 C 97 TE 20
Nominal Stent Graft Covered Length VNMF 31 31 C 174 TE 20
VNMF 31 31 C 229 TE 20
Distal Design VNMF 34 34 C 59 TE 20
VNMF 34 34 C 97 TE 20
VNMF 34 34 C 174 TE 20
VNMF 34 34 C 229 TE 20
20–46 mm
Distal Diameter VNMF 37 37 C 59 TE 20
VNMF 37 37 C 97 TE 20
10 mm VNMF 37 37 C 174 TE 20
Proximal Diameter 6 or 7 peaks VNMF 37 37 C 229 TE 20
VNMF 40 40 C 62 TE 22
Proximal Design VNMF 40 40 C 103 TE 22
C - CoveredSeal VNMF 40 40 C 183 TE 22
F - FreeFlo VNMF 40 40 C 223 TE 22
VNMF 43 43 C 62 TE 22
Device Confi guration VNMF 43 43 C 103 TE 22
FREEFLO STRAIGHT

M - Main Stent Graft VNMF 43 43 C 183 TE 22


Overlap VNMF 43 43 C 223 TE 22
Product Name marker
59-229 mm

VNMF 46 46 C 62 TE 22
VN - Valiant Navion™ System VNMF 46 46 C 103 TE 22
VNMF 46 46 C 183 TE 22
VNMF 46 46 C 223 TE 22

LOCATION OF OVERLAP MARKER


Proximal Overlap Marker positioning
Diameter (distance from fabric edge)
(mm) FreeFlo straight confi guration (mm)
20 48.0
22 48.0
25 48.0
28 56.5
31 56.5
20–46 mm
34 56.5
37 56.5
40 59.0
FREEFLO 43 59.0
STRAIGHT 46 59.0

34 35

UC201806182aEE Aortic Catalog.indd 36-37 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

FREEFLO TAPERED
Product Code
Proximal Distal Stent Graft Catheter
Graft Graft Covered Outer
Diameter Diameter Length Diameter
(mm) (mm) (mm) (Fr)
25–46 mm
VNMF 25 20 C 185 TE 18

VNMF 28 22 C 173 TE 20

VNMF 31 25 C 173 TE 20
0 VNMF 34 28 C 173 TE 20

VNMF 37 31 C 173 TE 20

VNMF 40 34 C 185 TE 22
-1
VNMF 43 37 C 185 TE 22

VNMF 46 40 C 185 TE 22
5 mm or 6 mm TAPERING

-2
FREEFLO TAPERED

GRADUATED TAPERING SPECIFICATIONS


173 & 185 mm

FREEFLO TAPERED FREEFLO TAPERED FREEFLO TAPERED


CONFIGURATION CONFIGURATION CONFIGURATION
-3 (5mm taper) (6mm taper) (6mm taper)

28mm x 22mm x 173mm


40mm x 34mm x 185mm
31mm x 25mm x 173mm
25mm x 20mm x 185mm 43mm x 37mm x 185mm
34mm x 28mm x 173mm
-4 37mm x 31mm x 173mm
46mm x 40mm x 185mm

Distance Distance Distance


from 1mm Taper from 1mm Taper from 1mm Taper
proximal Increments proximal Increments proximal Increments
-5 edge (mm) edge (mm) edge (mm)

0 0 0 0 0 0

37 -1 29 -1 31 -1
-6 74 -2 58 -2 62 -2

111 -3 87 -3 93 -3
20-40 mm 148 -4 115 -4 123 -4

185 -5 144 -5 154 -5

173 -6 185 -6

Available in nominal length of ~175mm length

FREEFLO TAPERED

36 37

UC201806182aEE Aortic Catalog.indd 38-39 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

COVEREDSEAL STRAIGHT
Product Code
Proximal Distal Stent Graft Catheter
Graft Graft Covered Outer
Diameter Diameter Length Diameter
(mm) (mm) (mm) (Fr)
VNMC 20 20 C 94 TE 18
20–46 mm VNMC 22 22 C 94 TE 18
VNMC 22 22 C 180 TE 18
VNMC 25 25 C 94 TE 18
VNMC 25 25 C 180 TE 18
VNMC 28 28 C 90 TE 20
VNMC 28 28 C 182 TE 20
VNMC 31 31 C 90 TE 20
VNMC 31 31 C 182 TE 20
VNMC 31 31 C 223 TE 20
VNMC 34 34 C 52 TE 20
VNMC 34 34 C 90 TE 20
VNMC 34 34 C 182 TE 20
COVEREDSEAL STRAIGHT

Overlap
marker VNMC 34 34 C 223 TE 20
VNMC 37 37 C 52 TE 20
VNMC 37 37 C 90 TE 20
52-223 mm

VNMC 37 37 C 182 TE 20
VNMC 37 37 C 223 TE 20
VNMC 40 40 C 55 TE 22
VNMC 40 40 C 95 TE 22
VNMC 40 40 C 175 TE 22
VNMC 40 40 C 218 TE 22
VNMC 43 43 C 55 TE 22
VNMC 43 43 C 95 TE 22
VNMC 43 43 C 175 TE 22
VNMC 43 43 C 218 TE 22
VNMC 46 46 C 55 TE 22
VNMC 46 46 C 95 TE 22
VNMC 46 46 C 175 TE 22
VNMC 46 46 C 218 TE 22

LOCATION OF OVERLAP MARKER


Proximal Overlap Marker positioning
Diameter (distance from fabric edge)
20–46 mm (mm) CoveredSeal straight confi guration (mm)
20 46.5
22 46.5
25 46.5
28 52.5
31 52.5
34 52.5
37 52.5
COVEREDSEAL 40 55.5
43 55.5
STRAIGHT
46 55.5

38 39

UC201806182aEE Aortic Catalog.indd 40-41 5/20/19 4:11 PM


Valiant Navion ™

Thoracic Stent Graft System

COVEREDSEAL TAPERED
Product Code
Proximal Distal Stent Graft Catheter
Graft Graft Covered Outer
Diameter Diameter Length Diameter
(mm) (mm) (mm) (Fr)
25–46 mm VNMC 25 20 C 186 TE 18

VNMC 28 22 C 207 TE 20

0 VNMC 31 25 C 207 TE 20

VNMC 34 28 C 207 TE 20

VNMC 37 31 C 207 TE 20
-1 VNMC 40 34 C 200 TE 22

VNMC 43 37 C 200 TE 22
COVEREDSEAL TAPERED

5 mm or 6 mm TAPERING
VNMC 46 40 C 200 TE 22
-2
186, 200 & 207 mm

GRADUATED TAPERING SPECIFICATIONS

-3 COVEREDSEAL TAPERED
CONFIGURATION
COVEREDSEAL TAPERED
CONFIGURATION
COVEREDSEAL TAPERED
CONFIGURATION
(5mm taper) (6mm taper) (6mm taper)

28mm x 22mm x 207mm


40mm x 34mm x 200mm
-4 25mm x 20mm x 186mm
31mm x 25mm x 207mm
34mm x 28mm x 207mm
43mm x 37mm x 200mm
46mm x 40mm x 200mm
37mm x 31mm x 207mm

Distance Distance Distance


from 1mm Taper from 1mm Taper from 1mm Taper
-5 proximal Increments proximal Increments proximal Increments
edge (mm) edge (mm) edge (mm)

0 0 0 0 0 0

-6 37 -1 35 -1 33 -1

74 -2 69 -2 67 -2

20-40 mm 112 -3 104 -3 100 -3

149 -4 138 -4 133 -4

186 -5 173 -5 167 -5

207 -6 200 -6

Available in ~ 175mm nominal length only for the smallest device


Devices from 28mm to 46mm available in ~200mm nominal length
COVEREDSEAL
TAPERED

40 41

UC201806182aEE Aortic Catalog.indd 42-43 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

FEATURES COMPONENT PLACEMENT GUIDE

Conformability Delivered
22–46 26–46 DISTINCT RADIOPAQUE MARKERS
Sinusoidal shape and placement of nitinol springs provide mm mm
flexibility and conformability 8 Figur8 marker

Super-elastic nitinol springs exert active radial force to ~12 mm 8-Peak 0 Zer0 marker
enhance seal and conformability 8 8 8 8

(PROXIMAL COMPONENT) 107–212 mm


FREEFLO STRAIGHT

(PROXIMAL COMPONENT) 152–167 mm


FREEFLO TAPERED
Confidence in Control
22–46 26–46 22–46
Tip capture provides controlled deployment and precise mm mm mm
placement in the thoracic aorta 8 8
Tip capture release handle provides simple turn-and-pull 8 8 8 8 8 8

(DISTAL COMPONENT) 107–117 mm


DISTAL BARE SPRING STRAIGHT
(DISTAL COMPONENT) 100–205 mm
CLOSED WEB STRAIGHT

(DISTAL COMPONENT) 150–160 mm


CLOSED WEB TAPERED
motion to release proximal stents

VALIANT CAPTIVIA
Advanced Design†
Proximal 8-Peak FreeFlo configuration evenly distributes
0 0 8 8 8
radial force over multiple apices 22–46 22–42
mm mm
Platinum iridium Figur8 markers provide high visibility
and assist deployment
Broad selection of proximal and distal components treats 0
a variety of patients
0 0
Optimised Access 22–46
mm
Crossing profile is similar to or lower than other thoracic 22–46 22–42
mm mm
stent grafts
Hydrophilic coating facilitates stent graft delivery ~12 mm
OVERLAP LENGTH 8-Peak
Easy three-step deployment process Proximal Diameter Overlap Length
of Stent Graft (mm) (mm)
22 50
24 50
26 50
28 55
30 55
32 55
34 55
36 60
38 60
40 60
42 60

Test data on file at Medtronic. Bench test results may not be indicative of 44 65
clinical performance. 46 65
Overlap lengths may vary by ± 5 mm

42 43

UC201806182aEE Aortic Catalog.indd 44-45 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

VALIANT ™ CAPTIVIA™ SYSTEM PROXIMAL FREEFLO STRAIGHT


PRODUCT CODE DESCRIPTION Product Code
VA M F 22 22 C 100 TE 22 112 Proximal Distal Catheter
Stent
Graft
Graft Graft Distal Outer
Covered
Stent Graft Diameter Diameter Design Diameter
Length
Covered Length (mm) (mm) (Fr)
(mm)
VAMF 22 22 C 100 TE 22 112
Catheter Outer VAMF 24 24 C 100 TE 22 112
Diameter
VAMF 26 26 C 100 TE 22 112
Delivery System VAMF 28 28 C 100 TE 22 117
TE - Thoracic VAMF 30 30 C 100 TE 22 117
VAMF 32 32 C 100 TE 22 117
Nominal Stent Graft Covered Length VAMF 34 34 C 100 TE 24 107
VAMF 36 36 C 100 TE 24 107
Distal Design
VAMF 38 38 C 100 TE 24 107
C - Closed Web1
VAMF 40 40 C 100 TE 24 107
B - Bare Spring
22–46 mm VAMF 42 42 C 100 TE 25 112
Distal Diameter VAMF 44 44 C 100 TE 25 112
VAMF 46 46 C 100 TE 25 112
Proximal Diameter
VAMF 22 22 C 150 TE 22 152
VAMF 24 24 C 150 TE 22 152
Proximal Design
VAMF 26 26 C 150 TE 22 152
C - Closed Web1
F - FreeFlo VAMF 28 28 C 150 TE 22 157
VAMF 30 30 C 150 TE 22 157
Device Confi guration VAMF 32 32 C 150 TE 22 157
TOTAL COVERED

M - Main Stent Graft


107–212 mm

VAMF 34 34 C 150 TE 24 167


LENGTH

Product Name VAMF 36 36 C 150 TE 24 167


VA - Valiant™ System VAMF 38 38 C 150 TE 24 167
VAMF 40 40 C 150 TE 24 167
VAMF 42 42 C 150 TE 25 157
VAMF 44 44 C 150 TE 25 157
VAMF 46 46 C 150 TE 25 162
VAMF 30 30 C 200 TE 22 192
VAMF 32 32 C 200 TE 22 192
VAMF 34 34 C 200 TE 24 212
VAMF 36 36 C 200 TE 24 207
22–46 mm
VAMF 38 38 C 200 TE 24 207
VAMF 40 40 C 200 TE 24 212
VAMF 42 42 C 200 TE 25 207
1
The proximal end of all Valiant™ stent grafts PROXIMAL FREEFLO VAMF 44 44 C 200 TE 25 212
include a mini support spring. STRAIGHT
VAMF 46 46 C 200 TE 25 212

44 45

UC201806182aEE Aortic Catalog.indd 46-47 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

26–46 mm

PROXIMAL FREEFLO TAPERED


Product Code
Stent
Proximal Distal Catheter
Graft
Graft Graft Distal Outer
Covered
Diameter Diameter Design Diameter
Length
(mm) (mm) (Fr)
(mm)
VAMF 26 22 C 150 TE 22 152

VAMF 28 24 C 150 TE 22 157

VAMF 30 26 C 150 TE 22 157


TOTAL COVERED
152–167 mm

VAMF 32 28 C 150 TE 22 157


LENGTH

VAMF 34 30 C 150 TE 24 167

VAMF 36 32 C 150 TE 24 167

VAMF 38 34 C 150 TE 24 167

VAMF 40 36 C 150 TE 24 167

VAMF 42 38 C 150 TE 25 157

VAMF 44 40 C 150 TE 25 157

VAMF 46 42 C 150 TE 25 162

22–42 mm

PROXIMAL FREEFLO
TAPERED

46 47

UC201806182aEE Aortic Catalog.indd 48-49 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

Each Valiant™ thoracic stent graft device must be ordered in a Dissection:


size appropriate to fit the patient’s anatomy. Proper sizing of the Do not oversize the stent graft more than 10% of the healthy aorta
Valiant™ thoracic stent graft is the responsibility of the physician. nominal diameter. The following table is provided as a guideline:
Aneurysms, Penetrating Ulcers and Traumatic Ruptures: Suggested Stent Graft
Native Vessel (mm) Oversizing (mm)
Oversize the aortic portion of the stent graft by 3 to 5 mm, Diameter (mm)
as appropriate for the patient. The following table is provided 20 22 2
as a guideline: 21 22 1
22 24 2
Suggested Stent Graft 23 24 1
Native Vessel (mm) Oversizing (mm)
Diameter (mm) 24 26 2
25 26 1
18 22 4
26 28 2
19 22 3
27 28 1
20 24 4
28 30 2
21 24 3
29 32 3
22 26 4
30 32 2
23 26 3
31 34 3
24 28 4
32 34 2
25 28 3
33 36 3
25 30 5
34 36 2
26 30 4
35 38 3
27 30 3
36 38 2
27 32 5
37 40 3
28 32 4
38 40 2
29 32 3
39 42 3
29 34 5
40 42 2
30 34 4
40 44 4
31 34 3
41 44 3
31 36 5
42 44 2
32 36 4
42 46 4
33 38 5
43 46 3
34 38 4
44 46 2
35 40 5
36 40 4
37 42 5 For Additional Sections:
38 42 4 When the stent graft junction is located within the aneurismal sac or
39 44 5 is not supported by tissue, a 4 mm oversizing between the primary
40 44 4 component and additional section is recommended. When the stent
41 46 5 graft junction is supported by tissue (e.g., dissections), less oversizing
42 46 4 may be appropriate to satisfy the oversizing recommendations
listed above.

48 49

UC201806182aEE Aortic Catalog.indd 50-51 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

CLOSED WEB STRAIGHT


Product Code
Stent
Proximal Distal Catheter
Graft
Graft Graft Distal Outer
Covered
Diameter Diameter Design Diameter
22–46 mm Length
(mm) (mm) (Fr)
(mm)
VAMC 22 22 C 100 TE 22 105
VAMC 24 24 C 100 TE 22 105
VAMC 26 26 C 100 TE 22 105
VAMC 28 28 C 100 TE 22 110
VAMC 30 30 C 100 TE 22 110
VAMC 32 32 C 100 TE 22 110
VAMC 34 34 C 100 TE 24 100
VAMC 36 36 C 100 TE 24 100
VAMC 38 38 C 100 TE 24 100
VAMC 40 40 C 100 TE 24 100
VAMC 42 42 C 100 TE 25 105
TOTAL COVERED

VAMC 44 44 C 100 TE 25 105


100–205 mm

VAMC 46 46 C 100 TE 25 105


LENGTH

VAMC 22 22 C 150 TE 22 145


VAMC 24 24 C 150 TE 22 145
VAMC 26 26 C 150 TE 22 145
VAMC 28 28 C 150 TE 22 150
VAMC 30 30 C 150 TE 22 150
VAMC 32 32 C 150 TE 22 150
VAMC 34 34 C 150 TE 24 160
VAMC 36 36 C 150 TE 24 160
VAMC 38 38 C 150 TE 24 160
VAMC 40 40 C 150 TE 24 160
VAMC 42 42 C 150 TE 25 150
VAMC 44 44 C 150 TE 25 150
VAMC 46 46 C 150 TE 25 155
VAMC 30 30 C 200 TE 22 185
VAMC 32 32 C 200 TE 22 185
22–46 mm VAMC 34 34 C 200 TE 24 205
VAMC 36 36 C 200 TE 24 200
VAMC 38 38 C 200 TE 24 200
VAMC 40 40 C 200 TE 24 205
VAMC 42 42 C 200 TE 25 200
VAMC 44 44 C 200 TE 25 205
VAMC 46 46 C 200 TE 25 205

CLOSED WEB STRAIGHT

50 51

UC201806182aEE Aortic Catalog.indd 52-53 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

26–46 mm

CLOSED WEB TAPERED


Product Code
Stent
Proximal Distal Catheter
Graft
Graft Graft Distal Outer
Covered
Diameter Diameter Design Diameter
Length
(mm) (mm) (Fr)
(mm)
VAMC 26 22 C 150 TE 22 150

VAMC 28 24 C 150 TE 22 150


TOTAL COVERED

VAMC 30 26 C 150 TE 22 150


150–160 mm
LENGTH

VAMC 32 28 C 150 TE 22 150

VAMC 34 30 C 150 TE 24 160

VAMC 36 32 C 150 TE 24 160

VAMC 38 34 C 150 TE 24 160

VAMC 40 36 C 150 TE 24 160

VAMC 42 38 C 150 TE 25 150

VAMC 44 40 C 150 TE 25 150

VAMC 46 42 C 150 TE 25 155

22–42 mm

CLOSED WEB TAPERED

52 53

UC201806182aEE Aortic Catalog.indd 54-55 5/20/19 4:11 PM


Valiant Captivia ™ ™

Thoracic Stent Graft Delivery System

22–46 mm

DISTAL BARE SPRING STRAIGHT


Product Code
Stent
Proximal Distal Catheter
Graft
Graft Graft Distal Outer
Covered
Diameter Diameter Design Diameter
Length
(mm) (mm) (Fr)
(mm)
VAMC 22 22 B 100 TE 22 112

VAMC 24 24 B 100 TE 22 112


TOTAL COVERED

VAMC 26 26 B 100 TE 22 112


107–117 mm
LENGTH

VAMC 28 28 B 100 TE 22 117

VAMC 30 30 B 100 TE 22 117

VAMC 32 32 B 100 TE 22 117

VAMC 34 34 B 100 TE 24 107

VAMC 36 36 B 100 TE 24 107

VAMC 38 38 B 100 TE 24 107

VAMC 40 40 B 100 TE 24 107

VAMC 42 42 B 100 TE 25 112

VAMC 44 44 B 100 TE 25 112

VAMC 46 46 B 100 TE 25 112

22–46 mm

DISTAL BARE SPRING STRAIGHT

54 55

UC201806182aEE Aortic Catalog.indd 56-57 5/20/19 4:11 PM


Heli-FX ™

EndoAnchor™ System HELI-FX ™ GUIDE

HELI-FX ™ APPLIER
FEATURES

Enhance outcomes and durability†


Helical EndoAnchor™ implants provide the stability of a
surgical anastomosis‡
Enhances the inherent sealing and fixation mechanisms ENDOANCHOR™
of an endograft CASSETTE
Simplifies revision surgery for endograft migration and
Type Ia endoleak
When used in combination with the Endurant™ II/IIs
stent graft system, indicated for AAA patients with neck
lengths <10mm down to 4mm
Tailor seal and fixation in primary and revision
EVAR and TEVAR
Steerable guide for precise and accurate EndoAnchor™
implant placement
Motorized, intuitive controls for precise placement TIP
DEFLECTION
of EndoAnchor™ implants LENGTH

Allow safe and effective treatment of more


complex anatomies

HELI-FX
Maximize outcomes in complex cases
Confidently and rapidly target and seal Type Ia endoleaks

EVAR ORDERING INFORMATION TEVAR ORDERING INFORMATION


Defl ected Recommended Working Defl ected Recommended Working
AAA O.D. Catalog TAA O.D. Catalog
Tip Reach Neck Diameter Length Tip Reach Neck Diameter Length
Components (mm) (Fr) Number Components (mm) (Fr) Number
(mm) (mm) (cm) (mm) (mm) (cm)
Heli-FX ™ System Heli-FX ™ System
22 18-28 62 16 SG-64 22 18-28 90 18 HG-18-90-22
Guide, 22 Guide, 22
Heli-FX System

Heli-FX System

28 28-32 62 16 HG-16-62-28 32 28-38 90 18 HG-18-90-32
Guide, 28 Guide, 32
Heli-FX Applier
™ Heli-FX System

42 38-42 90 18 HG-18-90-42
and EndoAnchor™ Guide, 42
Cassette (w/10 NA NA 86 12 SA-85 Heli-FX Applier

EndoAnchor™ and EndoAnchor™
Implants) Cassette (w/10 NA NA 114cm 12 HA-18-114
Ancillary EndoAnchor™
EndoAnchor™ Implants)
Cassette (w/5 NA NA NA NA EC-05 Ancillary
EndoAnchor™ EndoAnchor™
Implants) Cassette (w/5 NA NA NA NA EC-05
EndoAnchor™

Bench test data on file at Medtronic. Test data not indicative of clinical performance. Implants)

Melas N, et al. Helical EndoAnchor Implants Provide the Stability of a Surgical
Anastomosis. J Vasc Surg. 2012;55(6):1726-1733.
56 57

UC201806182aEE Aortic Catalog.indd 58-59 5/20/19 4:11 PM


TourGuide ™

Steerable Sheath

FEATURES
Precisely Guide Your Up to 180 degree Inner Diameter 6.5 Fr 7 Fr 8.5 Fr
deflection with Compatibility
Next Intervention† curve retention and
2.20 mm/
0.090”
2.50 mm/
0.099”
2.90 mm/
0.117”
For use with aortic
a radiopaque tip†
Quickly Access Indicated and peripheral 8.5 Fr 9.5 Fr 12 Fr
2.80 mm/ 3.20 mm/ 4.0 mm/
Anatomy with the TourGuide™ interventional devices 0.112” 0.125” 0.157”
Hydrophobic coated
Steerable Sheath.
sheath in three
TIP TIP TIP
Conformability working lengths: 2.20 mm/ 2.40 mm/ 2.80 mm/
45 cm, 55 cm, 0.088” 0.097” 0.112”
Steerable sheath improves and 90 cm
access to hard-to-reach Three Working Lengths
sites and eliminates need Can access challenging
to change sheaths to reach anatomy in order to
desired position 45 cm
perform aortic and 55 cm
Versatility peripheral interventions 90 cm

The TourGuide™ sheath


has a wide variety of Reinforced braid Adjustable Tip Deflection
applications within the technology ensures May reduce overall procedure
human vasculature, from kink resistance and
time by minimizing multiple
22 mm
17 mm
the periphery to the torque control while
maintaining optimal exchanges associated with 9 mm
intracardiac different catheter selections
flexibility even in
Control the most tortuous
Precise deflection using anatomy
the self-locking rotating ORDERING INFORMATION
knob allows you to Catalog Inner Diameter Usable Defl ection Length
maintain control of the

TOURGUIDE
Number Size (Fr) Length (cm) @ 180° (mm)
full procedure TG0654509 6.5 45 9
Self-locking TG0654517 6.5 45 17
rotating knob TG0655509 6.5 55 9
TG0655517 6.5 55 17
TG0659009 6.5 90 9
TG0704509 7.0 45 9
TG0704517 7.0 45 17
TG0705509 7.0 55 9
TG0705517 7.0 55 17
TG0709009 7.0 90 9
TG0854517 8.5 45 17
TG0854522 8.5 45 22

Bench Test Data on fi le at Medtronic.
TG0855517 8.5 55 17
Test data not indicative of clinical
performance TG0855522 8.5 55 22
TG0859017 8.5 90 17

58 59

UC201806182aEE Aortic Catalog.indd 60-61 5/20/19 4:11 PM


Sentrant ™

Introducer Sheath with Hydrophilic Coating

FEATURES THE CHOICE FOR SUPERIOR HEMOSTASIS†

Engineered to deliver procedural confidence


RADIOPAQUE MARKER BAND
EnsureSeal Technology delivers superior leak resistance
Smooth dialator to
versus competitors† sheath transition
Coil-reinforced tubing for added stability and kink resistance

WORKING LENGTHS:
28 cm AND 64 cm
Maintains lubricity after multiple insertions HYDROPHILIC
COATING
Radiopaque dilator shaft and sheath tip for accurate REINFORCED
COILED TUBING
visualization and guidance
64 cm configuration launched to service a broader range of
anatomies and procedures
Compatible with a wide range of endovascular portfolios GUIDEWIRE DIAMETER:
0.035"/0.89 mm

Superior leak resistance versus Cook Check-Flo


Performer™* introducer sheath and Gore DrySeal™*
Flex introducer sheath† LOCKING MECHANISM
ON DILATOR HANDLE
Compatible with Endurant™
Average Leakage (ml) per Product
and Valiant Navion™ stent graft
delivery systems
Average leakage over 2.5 hours (ml)

350 322 ml
300
ORDERING INFORMATION
250
200 Inner Diameter Usable Length
Catalog Number
(Fr) (cm)
150
SENSH1228W 12 28
100
64 ml SENSH1428W 14 28
50 SENSH1628W 16 28
0 ml
0 SENSH1828W 18 28
Cook Medical Gore DrySeal™* Medtronic
Check-Flo Flex Introducer Sentrant™ SENSH2028W 20 28
Performer™* Sheath Introducer SENSH2228W 22 28
Introducer Sheath Sheath
SENSH2428W 24 28

SENTRANT
SENSH2628W 26 28
Product (16Fr) SENSH1264W 12 64
SENSH1464W 14 64
*
Third party brands are trademarks of their respective owners

Leak Resistance Bench Test Data on file at Medtronic. Test data not indicative of SENSH1664W 16 64
clinical performance. Bench Test compared Cook Check-Flo Performer™* 16 Fr and SENSH1864W 18 64
Gore DrySeal™* Flex 16 Fr to Sentrant™ 16 Fr. Graph shows average leakage over an SENSH2064W 20 64
extrapolated 2.5 hour procedure. SENSH2264W 22 64
Disclaimer: 64 cm working length sheath may not be available in your region or country.
Please consult the approved indications for use. Content on specific Medtronic products SENSH2464W 24 64
is not intended for users in markets that do not have authorization for use. SENSH2664W 26 64
60 61

UC201806182aEE Aortic Catalog.indd 62-63 5/20/19 4:11 PM


Reliant ™

Stent Graft Balloon Catheter

FEATURES MULTIPLE PURPOSES, SINGLE SOLUTION

Expand Possibilities INTRODUCER SHEATH:


COMPATIBLE WITH 12Fr
A single-solution balloon catheter for your stent graft
procedure needs

Clinical uses include:


MATERIAL TYPE:
Abdominal and thoracic use COMPLIANT POLYURETHANE INFLATION DIAMETER:
(NON-LATEX) 10–46 mm
Endograft modeling
Endoleak sealing support

USABLE LENGTH:
Wide Range of Balloon Inflation Diameters

100 cm
BALLOON INFLATION TABLE
46 mm Balloon
SHAFT SIZE:
Diameter MI 8Fr
(mm) (cc)
10 3
20 9
30 19
40 41
46 † 60
CAUTION: This table is only a guide. Balloon expansion should be carefully
monitored under fluoroscopy. Do not exceed maximum inflation diameter
(46 mm). Rupture of balloon may occur.

PRODUCT INFORMATION

RELIANT ™ STENT GRAFT BALLOON CATHETER‡


Infl ation Shaft Usable Sheath GUIDEWIRE DIAMETER:
Product
Diameter Size Length Compatibility 0.038" / 0.9652 mm
Code
(mm) (Fr) (cm) (Fr) OR SMALLER
AB46 10–46 8 100 12

Please reference appropriate product Instructions for Use for a more detailed
list of indications, warnings, precautions and potential adverse events.

RELIANT

Maximum inflation diameter.

Does not contain latex.

62 63

UC201806182aEE Aortic Catalog.indd 64-65 5/20/19 4:11 PM


NOTES

65

UC201806182aEE Aortic Catalog.indd 66-67 5/20/19 4:11 PM


Invatec S.p.A. Medtronic
Via Martiri della Libertà 7 710 Medtronic Parkway NE
25030 Roncadelle (BS) Minneapolis, MN 55432
Italy USA
Tel: +39.030.2589311 Tel: +1.763.514.4000

Medtronic International Medtronic of Canada Ltd.


Trading Sàrl 99 Hereford Street
Route du Molliau 31 Brampton, Ontario L6Y 0R3
CH-1131 Tolochenaz Canada
Switzerland Tel: +1.905.460.3800
Tel: +41.21.802.7000

Medtronic Latin America Medtronic International Ltd.


3750 NW 87th Avenue, Suite 700 49 Changi South Avenue 2
Miami, FL 33178 Singapore 486056
USA Tel: +65.6436.5000
Tel: +1.786.709.4200

Medtronic Australasia Pty Ltd. Medtronic New Zealand


2 Alma Road, Unit N16, Mezzanine Level 5
Macquarie Park, NSW 2113 Gloucester Park Road
Australia Onehunga
Tel: +61.29857.9000 Auckland
Medtronic Korea Co., Ltd. Medtronic META FZ-LLC
5F, Sajo Building Office Park, Block D, 2nd Floor
1001 Daechi-dong, Kangnam-ku PO Box 500638
Seoul, 135-280 Dubai Internet City | Dubai,
Korea United Arab Emirates
Tel: +82.2.3404.3600 Tel: +971.4.818.2666

medtronic.com/aortic
UC201806182a EE © 2019 Medtronic. All rights reserved. Medtronic, Medtronic
logo and Further, Together are trademarks of Medtronic. ™*Third party brands are
trademarks of their respective owners. All other brands are trademarks of a
Medtronic company. Not for distribution in the USA, Japan or France. 05/19

C201806182aEE Aortic Catalog.indd 68 5/20/19 4:11 PM

You might also like