You are on page 1of 1

B

GRID GRID
LINE LINE
NOTES:
A A1
W SP /P273 /S /5023

T25-150 NF & FF T25-150 NF & FF 1. ALL DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE SPECIFIED.
- - 1
T32-125 T2 T32-125 T1 T16-150 EF T25-150 EF 2xT12-150 LINKS
- 2. FOR GENERAL NOTES REFER TO DRAWING NO. WSP /P273 /S /0001 & 0002.

2xT12-150 LINKS LV 3. FOR TYPICAL DETAILS REFER TO DRAWING NO. WSP /P273 /S /0003, 0004 & 0005.
T16-150 LINKS

T25-120 B1
Dwg.No.

2xT32-125 NF & FF 2xT32-125 NF & FF


T12-150 LINKS
T16-150 LINKS T16-150 CLOSED LINKS T32 T32
T32-150 T32-150
T32 T32
2xT12-150 LINKS

A2 T25 T25 T12-150 LINKS


4xT12-150 LINKS
- T32 T32
2xT12-150 LINKS T32 T32
T12-150 LINKS

GROUND LEVEL GROUND LEVEL GROUND LEVEL T16-150 LINKS T16 CLOSED LINKS
+6.80 +6.80 +6.80
T32 T32 T32 T32

T12-150 LINKS
T25 T25 T12-150 LINKS

T32 T32 T32 T32


T25 T25
T12-150 LINKS
T32 T32
T32 T32
T12-150 LINKS

REINFORCEMENT TYPICAL PIER ELEVATION (1250x2000) ELEVATION A SECTION A1 DETAIL 1 SECTION A2


SCALE 1 : 50 SCALE 1 : 50 - SCALE 1 : 50 - SCALE 1 : 25 - SCALE 1 : 25 -

GRID GRID
LINE LINE
B B1 2
T25-150 NF & FF T25-150 NF & FF
- - -
T32-125 T2 T32-125 T1 T32-125 T4 T32-125 T2 2xT12-150 LINKS

2xT12-150 LINKS LV
T16-150 LINKS
B T25-150 EF LV

T16-150 LINKS
T25-120 B1 T25-150 EF LV
B

T25-120 B2

2xT32-125 NF & FF 2xT32-125 NF & FF


T12-150 LINKS
T16-150 LINKS T16-150 CLOSED LINKS T32 T32
T32-150 T32-150
T32 T32
2xT12-150 LINKS

T12-150 LINKS
B2 T25 T25
4xT12-150 LINKS T32 T32
-
T25 T25 T32 T32
2xT12-150 LINKS
T12-150 LINKS LV T16 CLOSED LINKS
GROUND LEVEL GROUND LEVEL GROUND LEVEL
T16-150 LINKSLV
+6.80 +6.80 +6.80 T32 T32 T32 T32

T12-150 LINKS

T25 T25 T32 T32

T12-150 LINKS LV
T32 T32
T32 T32
B T12-150 LINKS

REINFORCEMENT TYPICAL PIER ELEVATION (1400x2000) AT M.J. ELEVATION B SECTION B1 DETAIL 2 SECTION B2
SCALE 1 : 50 SCALE 1 : 50 - SCALE 1 : 50 - SCALE 1 : 25 - SCALE 1 : 25 -

GRID GRID
LINE LINE
C C1
T25-150 NF & FF T25-150 NF & FF
- - 3
T32-125 T2 T32-125 T1 T16-150 EF T25-150 EF 2xT12-150 LINKS
-

2xT12-150 LINKS LV

T25-120 B1

2xT32-125 NF & FF 2xT32-125 NF & FF


T12-150 LINKS
T16-150 LINKS T16-150 CLOSED LINKS T32 T32
T32-150 T32-150
T32 T32
T12-150 LINKS
2xT12-150 LINKS
T32 T32
T32 T32
C2 T25 T25
4xT12-150 LINKS
- T16 CLOSED LINKS
2xT12-150 LINKS
T12-150 LINKS T32 T32 T32 T32
GROUND LEVEL GROUND LEVEL GROUND LEVEL T16-150 LINKS
+6.80 +6.80 +6.80

T12-150 LINKS
T12-150 LINKS
T25 T25

T25 T25
T32 T32 T32 T32
T12-150 LINKS
T32 T32
T32 T32
T12-150 LINKS

0 250 500 750 1000 1250

MILLIMETRES
1:25

REINFORCEMENT TYPICAL PIER ELEVATION (1600x2000) ELEVATION C SECTION C1 DETAIL 3 SECTION C2 0 500 1000 1500 2000 2500

SCALE 1 : 50 SCALE 1 : 50 - SCALE 1 : 50 - SCALE 1 : 25 - SCALE 1 : 25 -


MILLIMETRES 1:50

Rev. Date Description Checked Rev. Date Description Checked Signatures for Approval Key Plan N
Notes :
1. Measurements are based on metric system. A 28JAN2019 ISSUE FOR TENDER ALAN TAM Drawn Date Design Date
Consultant Hong Kong International Airport
2. All levels are in metres to Principal Datum (mPD) unless noted otherwise.
B 03MAY2019 ISSUE FOR LETTER OF CLARIFICATION ALAN TAM CSL 24OCT18 JIMMY CHU 24OCT18 Title
3. Do not scale drawing.
4. Figure dimensions are to be followed. Checkers Date Plot Date
5. Do not use for construction unless expressly permitted. JC 24OCT18 7/9/2019 1:33:31 PM
C18W10 - NORTH COMMERCIAL DISTRICT FOOTBRIDGE 1
6. The Contractor shall verify all conditions on the Site & notify the Employer's
Design Supervisor Date
Representative of any variations from dimensions before construction. in association with
PIER REINFORCEMENT DETAILS
Copyright in this document and all proprietary rights in the information it
contains belong to the AA. It is a condition of the supply of this document,
CALVIN LI 24OCT18 (SHEET 1 OF 2)
Authorised Representative Date
in whatever form, that the recipient shall hold it in confidence and shall not Scale Location Originator Design Ref. Discipline Number Status Revision
duplicate or otherwise reproduce it in whole or in part, nor disclose its contents Airport Authority HKIA Tower, 1 Sky Plaza Road, Hong Kong International Airport, Lantau, Hong Kong
without the written consent of the AA.
TIM ALDEBURGH 24OCT18
WSP/PBA L&O Tel : (852) 2188 7111 Fax : (852) 2824 0717 AS SHOWN Drawing No. WSP / P273 / S / 5023 CONSTRUCTION B

File Name :X:\2512133_P273_FB1\06_Issue Record\Construction\20190708_DIS002(Civil)\CADD\WSP_P273_T_S_5023-B.dgn User Name :liao.james