01
JUL2013
02
05 COMPANY
06 QUALITY
POLICY
07 REGULATORY
ASPECTS
08 TECHNICAL
SYMBOLS
09 TYPES OF
COLUMNS
11 BRACKETS
12 TC1 SERIES
15 TC2 SERIES
22 TC3 SERIES
03
COMPANY
Where we come from, who we are and what we do.
Headquartered in Braga and with more than 6 decades of experience in its field, O FELIZ -
Metalomecânica is a company specialized in metallic construction, sheet profiling, cutting and
bending of sheets, construction of lighting columns and communication towers, metalworking
in stainless steel and laser cutting.
A policy of continuous investment in state of the art equipment and a focus on highly qualified
and competent staff allows the company to maintain a production capacity and an immediate
response to the market’s demands and requests, making it a reference in its fields of action.
With a portfolio of well-known projects and clients, the company has the required knowledge and
means to serve in the global market, with solutions starting at the conception and elaboration of
the project, all the way to the construction and final assembly.
By focusing on the efficiency of the procedures and keeping a strong market orientation, the
company has been able to establish itself in an extremely competitive market, conquering its
customer’s trust due to the quality of the final product and the ability to follow through within
the deadlines.
With a growth strategy aimed at internationalization, O FELIZ - Metalomecânica exports to several
countries and has an industrial unit in Angola which has production capacity and the ability to
offer solutions for the market’s needs and requests.
05
QUALITY
Quality policy.
Working in an extremely competitive market, where clients are more and more demanding, the
Administration of O FELIZ believes that only with a real involvement, a strong market orientation,
the optimization of all resources and a reduction of the activities which do not add value, as
well as a strict compliance with the legal and statutory requirements applicable to the product, a
sustained growth can be possible.
We are committed to this goal, believing that together we will improve the performance of our
organization and we will stand as a reference company.
CE marking.
The CE marking exists to allow the free product
circulation within the European Economic Space,
while the voluntary markings aim at adding value
and differentiating the products in their market.
The compliance with the CE marking is evaluated
every year by the Certif association, through audits
which are external to the product, throughout its
entire production process.
Therefore, the European Commission considers the
CE marking a “passport” which allows the free and
legal circulation of merchandise within its borders,
in accordance with their high quality and security
standards, both for people and the environment.
06
REGULATORY
ASPECTS
Legal framework.
The Public Lighting columns presented in this PARTIAL SECURTITY FACTORS
catalogue meet the requirements set by the
standard EN 40 – Lighting Columns, and they The partial security factors were defined
are subject to the EC Conformity Verification, according to section 5.4 of the EN 40-3-3:2003.
in accordance to the Directive 89/106/EEC –
Construction Products. TYPE OF ACTION
Class
Wind Permanents
The safety verifications for Ultimate Limit A 1.4 1.2
used the contents of the EN 1991-1-4:2005 Maximum Horizontal 0,04 0,06 0,10
Actions in Structures – Wind Actions. The base Deflection (h+w) (h+w) (h+w)
values for the wind’s speed that we used were
h – column’s nominal height
the following: w – bracket’s horizontal projection
Zone Vref
A 28 m/s
The service conditions tables were defined
B 31 m/s
for a Class 3 maximum horizontal deflection.
The exposure areas mentioned in the service
Zone A: The entire Portuguese territory, except for Zone B; conditions tables refer to a maximum area of
wind exposure per lantern.
Zone B: The Azores and Madeira and the regions of the mainland
located in a coastal area of 5 km of width or with altitudes higher
than 600 m.
In order to verify the safety of the columns, we
adopted a lantern with a characteristic mass of
25 kg.
NOTE:
If you have any doubts about the conditions for applicability of
a product mentioned in this catalog, please contact the Public
Lighting Columns Department at O Feliz.
07
TECHNICAL
SYMBOLS
Technical symbols used in this document.
h – nominal height.
top
- top diameter.
base
- base diameter.
f - flange width.
g - distance between holes.
08
TYPES OF COLUMNS
CONICAL COLUMNS
Single or double bracket. Setting by flange or planting.
top top
h
Planting Solution
base base
The size of the foundation was defined for a ground Hot dip galvanizing in accordance with the standard S275JR steel in accordance with the standard EN
with an admissible tension of 300 kPa. In its design, NP EN ISO 1461. The columns can be delivered with a 10025-2.
we considered Class C20/25 concrete and A400NR different painting scheme.
reinforcement steel frame.
09
TYPES OF COLUMNS
CONICAL COLUMNS
Triple or quadruple bracket. Setting by flange or planting.
top top
base base
The size of the foundation was defined for a ground Hot dip galvanizing in accordance with the standard S275JR steel in accordance with the standard EN
with an admissible tension of 300 kPa. In its design, NP EN ISO 1461. The columns can be delivered with a 10025-2.
we considered Class C20/25 concrete and A400NR different painting scheme.
reinforcement steel frame.
10
BRACKETS
TYPES OF BRACKETS
Cylindrical geometry.
SINGLE BRACKET
DOUBLE BRACKET
TRIPLE BRACKET
QUADRUPLE BRACKET
CROSS PIECES
Top.
11
TC1 O Feliz reserves the right to change the technical characteristics of the columns, without prior notice. It is advised to contact the Public
Lightning Columns Department to verify the accuracy of the information in this document.
GENERAL CHARACTERISTICS
Post top conical columns. Setting by flange.
12
TC1 O Feliz does not take any responsibility for an incorrect interpretation of the service conditions listed in this document.
If you have any doubts, please contact the Public Lighting Columns Department.
SERVICE CONDITIONS
Load tables. Maximum wind exposure area per lantern [m2].
13
TC1
POST TOP CONICAL COLUMN
Setting by flange or planting.
14
TC2 O Feliz reserves the right to change the technical characteristics of the columns, without prior notice. It is advised to contact the Public
Lightning Columns Department to verify the accuracy of the information in this document.
GENERAL CHARACTERISTICS
Post top conical columns with single or double bracket. Setting by flange.
Post top conical columns with single or double bracket. Setting by planting.
15
TC2 O Feliz does not take any responsibility for an incorrect interpretation of the service conditions listed in this document.
If you have any doubts, please contact the Public Lighting Columns Department.
SERVICE CONDITIONS
Load tables. Maximum wind exposure area per lantern [m2].
16
TC2
POST TOP CONICAL COLUMN
Single bracket. Setting by flange.
17
TC2
POST TOP CONICAL COLUMN
Single bracket. Setting by planting.
18
TC2
POST TOP CONICAL COLUMN
Double bracket. Setting by flange.
19
TC2
POST TOP CONICAL COLUMN
Double bracket. Setting by planting.
20
TC3 O Feliz reserves the right to change the technical characteristics of the columns, without prior notice. It is advised to contact the Public
Lightning Columns Department to verify the accuracy of the information in this document.
GENERAL CHARACTERISTICS
Post top conical columns with triple or quadruple bracket. Setting by flange.
Post top conical columns with triple or quadruple bracket. Setting by planting.
21
TC3 O Feliz does not take any responsibility for an incorrect interpretation of the service conditions listed in this document.
If you have any doubts, please contact the Public Lighting Columns Department.
SERVICE CONDITIONS
Load tables. Maximum wind exposure area per lantern [m2].
22
TC3
POST TOP CONICAL COLUMN
Triple bracket. Setting by flange.
23
TC3
POST TOP CONICAL COLUMN
Triple bracket. Setting by planting.
24
TC3
POST TOP CONICAL COLUMN
Quadruple bracket. Setting by flange.
25
TC3
POST TOP CONICAL COLUMN
Quadruple bracket. Setting by planting.
26
28