You are on page 1of 1

Outdoor Directional Quad-band Antenna

ODV-065R17EKJJ-G
XXXX Pol, 65°
790-960/1710-2170/1710-2690/1710-2690MHz
16.2/16.2/16.4/16.8dBi, E-Tilt: 0-10/0-10/0-12/0-12

Electrical Specifications
Frequency Range (MHz)
790-960 1710-2170 1710-2690 1710-2690
Parameters / Specifications
1710- 1920- 2490-
790-896 880-960 1710- 1990 1920-2170
1990 2170 2690
Polarization 45°
Top 15.8 16.1 16.4
Gain (dBi) 15.8 16.2 16.0 16.2
Bottom 16.2 16.5 16.8
Horizontal Beamwidth (°) 64 62 67 62 67 64 61
Vertical Beamwidth (°) 10.2 9.2 7.7 7.2 9.2 8.3 6.4
Electrical Downtilt (°) 0-10 0-10 0-12 / 0-12
≥17(0o) ≥17(0o) ≥17(0 o)
1st Upper Sidelobe Suppression (dB) ≥16(5 o) ≥16(5 o), ≥16(6 o)
≥15(10 o) ≥15(10 o) ≥15(12 o)
Front-To-Back Ratio 180°30°(dB) ≥25
Cross-polar Discrimination @0°(dB) ≥18(typ.)
Beam Tracking Avg. (dB) 2
VSWR ≤1.5:1
Isolation Intra-system (dB) ≥28
Isolation Inter-system (dB) ≥30
IMD3 (2x43 dBm Carrier) (dBc) <-150
Maximum Power per Port (W) 500 300 250
Impedance (Ω) 50

Mechanical Specifications
Parameters Specifications
Dimensions, HxWxD (mm) / (in) 2000x380x138 / 78.7x15.0x5.4
Weight, w/o Mounting Kit (kg) / (lb) 33.5 / 73.6
Weight, with Mounting Kit (kg) / (lb) 39.0 / 86.0
Radome Material and Color Fiberglass, Light Grey
Mounting Kit 00-ZJ10(08)
Connector Type and Location 8 x 7/16 DIN-Female, Bottom
Operational Temperature (oC) -50 to +70
Operational Humidity (%) ≤95
Operational/Max Wind Speed (km/h) 150 / 200
Wind Load @150km/h
1460 / 297 / 1734
Frontal / Lateral / Rearside (N)
Shipping Dimensions, HxWxD (mm) / (in) 2340x490x270 / 92.1x19.3x10.6
Shipping Weight (kg) / (Ib) 46.8 / 103.2
Lightning Protection Direct Ground

Connector Position

1710-2690 1710-2690 1710-2170 790-960


+45° +45° -45° -45°

1710-2690 1710-2690 1710-2170 790-960


-45° -45° +45° +45°

DIN 7/16” F DIN 7/16” F DIN 7/16” F DIN 7/16” F DIN 7/16” F DIN 7/16” F DIN 7/16” F DIN 7/16” F

© 2013 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering. Page 1 of 1
Specifications may differ depending on region and customers’ requirements.
DS-Control: 2-0-0 / 0914