3108/2022 11:28 Install Battery Harness -omeq 100106 = Service ADVISOR™ e JOHN DEERE omcq100106 - MPA2S00 Planting Monitor - Install Battery Harness BM000255-UN: Battery Harness LEGENI A-12-Pin Connector B- Plastic Seal C-Tie Band D - Fuse Holder (2 used) E- White Cable (+) F - Black Cable (-) 1. Connect 12-pin connector (A) to terminal 2 at rear part of console. 2. NOTE: MPA2500 Planting Monitor operates at 12 VDC or 24 VDC. Connect white cable (+) (E) to positive (+) battery terminal. 3. Connect black cable (-) (F) to negative (-) battery terminal. IMPORTANT: On machines with two batteries, 24 VDC system, black cable (-) (F) should be connected to negative battery terminal (-) of the battery that has its negative machine terminal connected and white cable (+) (E) to positive terminal of the second battery where the positive machine terminal is connected. MPA2S00 Planting Monitor is designed to operate normally even during tractor engine start-up when a system voltage reduction occurs. Itis absolutely necessary that the connection of the power cables (+) (E) and (-) (F) is made directly to the battery of the machine, otherwise, every time the machine starts and the voltage drops the monitor will turn off or will oscillate. | A\caution: serviceadvisorlocal deere.com 3074WebSAmanvalsfomaq100106/0900 1faa8344cbat 1 3108/2022 11:28 Install Battery Harness -omeq 100106 = Service ADVISOR™ Battery terminals should always be clean and connections properly tightened to avoid any monitor supply problem that causes monitor malfunction. (0U90500,0000400-19-20150615 Copyright © Deere & Company, al rights reserved. serviceadvisorlocal deere.com 3074WebSAmanvalsfomaq100106/0900 1faa8344cbat 2