Professional Documents
Culture Documents
21
Improper Calibration
Action:
HCU diagnostic code "27" is stored if a sensor or valve is not properly calibrated during
the calibration process.
Only proper calibration will clear this diagnostic code. However, an associated
diagnostic code will be stored and will indicate which sensor or valve is the cause.
Do the following to determine the cause of diagnostic code "HCU/27":
Clear HCU code and record all diagnostic codes which reappear.
Do the appropriate test procedure for the displayed diagnostic codes, to make
sure the circuit is good.
NOTE:
If a fault is corrected, the diagnostic code will return (if
cleared) until a successful calibration is completed.
Result:
NOT OK:
Calibrate the hitch until a successful calibration is completed.
RX33672,000076E-19-20001016