You are on page 1of 64

250 G.P.M.

912 SERIES Section 912 Page 401


Date June 1999
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 401
Dated December 1992

SIZE : 2.5-481-10B / 2.5-483-10B MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


150 IMP. PATT. NO. 444A251
200
CASE PATT. NO.
40% 50% 180A023 UPPER (ALL)
125 60% 180A024 LOWER (481)
65%
180A071 LOWER (483)
68%
160 167 PSI
70%
100
140 PSI 68%
65%
120
(METERS of H 2O)

60%
75 110 PSI

52
P.S.I.

50
80
80 PSI to
167
40
52 PSI
P.S.I.
25 250 BHP
100
375
BHP FOR 167 PSI CURVE
75

50

BHP FOR 52 PSI CURVE 25

0
U.S. GPM 100 200 300 400 500 600 700
L/S 10 20 30 40
M 3/HR 25 50 75 100 125 150
PC-147558A

SIZE : 3-481-10 / 3-483-10 MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A131

CASE PATT. NO.


120 180A027 UPPER (ALL)
80 180A028 LOWER (481)
55% 65% 180A073 LOWER (483)
75%
100
100 PSI

60
80
80 PSI
(METERS of H 2O)

75%

40
60
40 60 PSI 70%
P.S.I.

40
to
100
40 PSI

20
250 375
20 P.S.I.
BHP FOR 100 PSI CURVE BHP
50
40
30
BHP FOR 40 PSI CURVE 20
10
0
U.S. GPM 100 200 300 400 500 600 700 800 900 1000 1100
L/S 15 30 45 60 75
M 3/HR 50 100 150 200 250
PC-117424
Section 912 Page 402 500 G.P.M. 912 SERIES
Date October 2005 ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 402
Dated April 2000
SIZE : 3-492-10A MODEL: 492 IMPELLER : Enclosed R. P. M. : 3535
IMP. PATT. NO. 444A725
180
240 CASE PATT. NO. 190A041 UPPER
190A040 LOWER

150
200

65%
(METERS of H2O)

120 69%
160 165 PSI
P.S.I.

150 PSI
125
69%
65%
to
90
120 125 PSI

165 500
61%

P.S.I. 60
80 750

BHP
BHP FOR 165 PSI CURVE
100
30 40 80
60
BHP FOR 125 PSI CURVE
40
20
0
U.S. GPM 100 200 300 400 500 600 700 800
L/S 10 20 30 40 50
M3/HR 40 80 120 160 200
PC-168435
500 G.P.M. 912 SERIES Section 912 Page 403
Date January 2001
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 403
Dated October 2000

SIZE : 3-481-10 / 3-483-10 MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


150 IMP. PATT. NO. 444A131
200
CASE PATT. NO.
180A027 UPPER (ALL)
125 180A028 LOWER (481)
180A073 LOWER (483)
160 55% 65% 75%
80%
100 150 PSI

120 125 PSI 80%


(METERS of H 2O)

75
75%
100 PSI
50
P.S.I.

50
80
75 PSI
to
70% 150
40
50 PSI P.S.I.
25 BHP
500 BHP FOR 150 PSI CURVE 100
750

75

50
BHP FOR 50 PSI CURVE
25

0
U.S. GPM 200 400 600 800 1000 1200
L/S 20 40 60 80
M 3/HR 50 100 150 200 250 300
PC-117427

SIZE : 4-481-11A / 4-483-11A MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A325

50 70 CASE PATT. NO.


180A035 UPPER (ALL)
180A036 LOWER (481)
60% 180A076 LOWER (483)
60 75%
80%
40
83%
55 PSI
50
50 PSI
83%
30
80%
(METERS of H 2O)

40
40 PSI

40
75%
P.S.I.

70%
30
20

500
to
55
750
20

10 P.S.I.
10

BHP
BHP FOR 55 PSI CURVE 40

20
BHP FOR 40 PSI CURVE

0
U.S. GPM 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
L/S 15 30 45 60 75
M 3/HR 50 100 150 200 250 300
PC-117425
Section 912 Page 404 500 G.P.M. 912 SERIES
Date January 2001
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 404
Dated April 2000

SIZE : 4-481-15 / 4-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A326

CASE PATT. NO.


60 70% 180A037 UPPER (ALL)
75% 180A038 LOWER (481)
80
80 PSI 180A078 LOWER (483)
75%
50

70%
60
40 60 PSI
(METERS of H 2O)

60%

60 30
P.S.I.

to
40

80 20

P.S.I. 20
500 750

10

BHP
BHP FOR 80 PSI CURVE
60

40

BHP FOR 60 PSI CURVE


20

0
U.S. GPM 200 400 600 800 1000 1200
L/S 15 30 45 60 75
M 3/HR 50 100 150 200 250 300
PC-117426

SIZE : 4-485-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A335 &
200 444A336
280
CASE PATT. NO.
180A160 UPPER (485)
180A159 LOWER (485)
240
55% 60% 65%
70%
150 71%
210 PSI
200 71%
70%
195 PSI
(METERS of H 2O)

170 PSI

150
160
P.S.I.

100 150 PSI

to
210 120 500

750
P.S.I. BHP
80 200
50
BHP FOR 210 PSI CURVE

100

BHP FOR 150 PSI CURVE

0
U.S. GPM 100 200 300 400 500 600 700 800 900
L/S 10 20 30 40 50 60
M 3/HR 40 80 120 160 200
PC-117428
500 G.P.M. 912 SERIES Section 912 Page 405
Date JULY 2007
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 405
Dated July 2001

SIZE : 5-485-12 MODEL: 480 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444R430
400 444R431
40%
50% CASE PATT. NO.
180A441 UPPER
500 60% 180A442 LOWER
65%
476 PSI 66%
320
67%
400 66%
385 PSI 65%
(METERS of H 2O)

240
60%
300 315 PSI
228
P.S.I.

275 PSI
to
476
160 228 PSI
200
500
P.S.I.
750 BHP
BHP FOR 476 PSI CURVE
80 400
100
300

200
BHP FOR 228 PSI CURVE

0 0 100

0
U.S. GPM 200 400 600 800 1000 1200 1400
L/S 15 30 45 60 75 90
M 3/HR 50 100 150 200 250 300 350
PC-174441

SIZE : 3-491-9C MODEL: 491 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A701

125 180
CASE PATT. NO. 190A002 UPPER
190A001 LOWER
160

65%
100 71%
140
140 PSI 73%
75%
(METERS of H 2O)

120

75
75%
73%
95
P.S.I.

100
to
140
95 PSI

80
50
500 P.S.I.
60 750

BHP
BHP FOR 140 PSI CURVE
40 80
25
BHP FOR 95 PSI CURVE
20 40

0
U.S. GPM 100 200 300 400 500 600 700 800 900 1000
L/S 15 30 45 60
M 3/HR 40 80 120 160 200 240
PC-168434
Section 912 Page 406 500 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 406
Dated June 1999

SIZE : 4-492-10 MODEL: 492 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A734
60%
65%
70%
120
170 PSI 75% CASE PATT. NO. 190A054 UPPER
160 77% 190A053 LOWER
78%

78%
100 140
77%
138 PSI
75%
120
(METERS of H 2O)

80
70%
110 PSI

110
100
P.S.I.

65%

to 60
80
500
750

170
P.S.I. 40
60

40
BHP
BHP FOR 170 PSI CURVE 150
20
20 100

BHP FOR 110 PSI CURVE 50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 80 160 240 320 400
PC-168436

SIZE : 4-492-14 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A703
80

100 CASE PATT. NO. 190A004 UPPER


190A003 LOWER

60 60% 65%
80 69%

75 PSI
69%
65%
60
(METERS of H 2O)

40 65 PSI
60%

40
P.S.I.

to
40
40 PSI

75 20

20
P.S.I. 500 BHP
50
750

40

BHP FOR 75 PSI CURVE 30

20

BHP FOR 40 PSI CURVE


10

0
U.S. GPM 100 200 300 400 500 600 700 800 900
L/S 10 20 30 40 50
M 3/HR 40 80 120 160 200
PC-168437
500 G.P.M. 912 SERIES Section 912 Page 407
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 407
Dated June 1999

SIZE : 4-492-18 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A726
160

CASE PATT. NO. 190A006 UPPER


200 190A005 LOWER

120
160

50%
60%
(METERS of H 2O)

65%
120 125 PSI
65%
80
76
P.S.I.

60%

to
100 PSI

80
76 PSI 125
40
500 P.S.I.
40
750
BHP
BHP FOR 125 PSI CURVE
100
80
BHP FOR 76 PSI CURVE 60
40
20
0
U.S. GPM 100 200 300 400 500 600 700 800 900
L/S 10 20 30 40 50
M 3/HR 40 80 120 160 200
PC-168438

SIZE : 6-491-12A MODEL: 491 IMPELLER : Enclosed R. P. M. : 3565


240 IMP. PATT. NO. 444A709

CASE PATT. NO. 190A018 UPPER


300 60% 190A017 LOWER
65%
200 70%
278 PSI
75%

250
76%
160 75%
(METERS of H 2O)

200 70%

191
191 PSI
P.S.I.

120 65%

150
500 750 60%
to
278
80
100
BHP
250
P.S.I.
200
BHP FOR 278 PSI CURVE
150

BHP FOR 191 PSI CURVE 100

50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 15 30 45 60 75 90 105
M 3/HR 75 150 225 300 375
PC-168439
Section 912 Page 408 750 G.P.M. 912 SERIES
Date June 1, 2007 ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 408
Dated April 2000

SIZE : 4-481-11A / 4-483-11A MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A325

CASE PATT. NO.


60% 180A035 UPPER (ALL)
60 75% 180A036 LOWER (481)
40 80% 180A076 LOWER (483)
83%

50
50 PSI

83%

30
(METERS of H 2O)

80%
40
40 PSI

40
P.S.I.

75%

to
70%
30
20
50
750
P.S.I. 20 1125
BHP
40
BHP FOR 50 PSI CURVE

10

BHP FOR 40 PSI CURVE 20

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800
L/S 20 40 60 80 100 120
M 3/HR 100 200 300 400
PC-117429

SIZE : 4-481-11C / 4-483-11C MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


240 IMP. PATT. NO. 444A135

160
50% CASE PATT. NO.
60% 180A035 UPPER (ALL)
70% 180A036 LOWER (481)
200 75% 180A076 LOWER (483)
80%
192 PSI
82%
120 80%
170 PSI
160
75%
150 PSI
70%
(METERS of H 2O)

65 80
120 125 PSI

to
P.S.I.

192
100 PSI

80

P.S.I. 65 PSI
40

40
BHP
750
1125 240
BHP FOR 192 PSI CURVE
160

BHP FOR 65 PSI CURVE 80

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 75 150 225 300 375
PC-148512
750 G.P.M. 912 SERIES Section 912 Page 409
Date July 2007
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 409
Dated June 2007

SIZE : 4-481-11D/4-483-11D MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A476

250 CASE PATT. NO.


180A497 UPPER (ALL)
180A498 LOWER (481)
30 180A499 LOWER (483)
40% 50%
60%
200 65%
192 PSI
70%
75%
80%
2O)

20 150
(METERS of H

83
P.S.I.

100 to
10
83 PSI
192
750
P.S.I.
50
1125 BHP
200
BHP FOR 192 PSI CURVE
0 0 150
100
BHP FOR 83 PSI CURVE
50
0
U.S. GPM 250 500 750 1000 1250 1500
L/S 20 40 60 80
M3/HR 100 200 300
PC-173677
Section 912 Page 410 750 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 410
Dated June 1999

SIZE : 4-481-15 / 4-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A326

CASE PATT. NO.


120 180A037 UPPER (ALL)
180A038 LOWER (481)
80
180A078 LOWER (483)
70%
75%
100

95 PSI 75%

60 70%
85 PSI
80
(METERS of H 2O)

71 71 PSI
60%
P.S.I.

to
60
40

95
40
P.S.I.
750
20 1125 BHP
BHP FOR 95 PSI CURVE 80

BHP FOR 71 PSI CURVE 40

0
U.S. GPM 200 400 600 800 1000 1200 1400
L/S 15 30 45 60 75 90
M 3/HR 50 100 150 200 250 300 350
PC-117431

SIZE : 5-481-15 / 5-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A328
60%
70%
50 CASE PATT. NO.
70 180A041 UPPER (ALL)
70 PSI
180A042 LOWER (481)
80% 180A080 LOWER (483)
60
60 PSI
40

50 80%
50 PSI
(METERS of H 2O)

30
50 40
70%
P.S.I.

to 750
30 60%
70 20
1125
P.S.I. 20

10 BHP
10 80
BHP FOR 70 PSI CURVE

BHP FOR 50 PSI CURVE 40

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000
L/S 20 40 60 80 100 120
M 3/HR 75 150 225 300 375 450
PC-117430
750 G.P.M. 912 SERIES Section 912 Page 410.1
ELECTRIC MOTOR DRIVE Date June 2008
Supersedes Section 912 Page 410.1
Dated July 2001

SIZE : 6-485-12 MODEL: 480 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444R432
444R433
CASE PATT. NO.
400
40% 180A443 UPPER
50%
60% 180A444 LOWER
63% 65%
500
506 PSI
70%
320
71%

400 70%
390 PSI
65%
(METERS of H 2O)

240 63%

60%
300 310 PSI

310
P.S.I.

160 750
to
200
1125
BHP FOR 506 PSI CURVE
BHP 506
500
80
P.S.I.
100 400

300
BHP FOR 310 PSI CURVE

0 0 200

100

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800
L/S 20 40 60 80 100
M 3/HR 50 100 150 200 250 300 350 400
PC-174444

158
to
211
P.S.I.
Section 912 Page 410.2 750 G.P.M. 912 SERIES
Date February 2011
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 410.2
Dated July 2001

SIZE: 6-485-16B MODEL: 485 IMPELLER : Enclosed R. P. M. : 1770


250 IMP. PATT. NO. 444A496 & 444A497
CASE PATT. NO. Upper : 180A511
Lower : 180A512
40%
50%
100 60%
200 203 PSI 65%

70%
183 PSI

150 158 PSI


50
(METERS of H2O)

750 GPM

158
P.S.I.

1125 GPM

100
to
203
P.S.I. 50
BHP
200

BHP FOR 203 PSI CURVE 150


BHP FOR 183 PSI CURVE
BHP FOR 158 PSI CURVE 100

50

0
U.S. GPM 500 1000 1500 2000 2500
L/S 50 100 150
M3/HR 200 400
PC-204621
750 G.P.M. 912 SERIES Section 912 Page 411
Date June 1999
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 411
Dated June 1992

SIZE : 6-485-17A MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 4238 & 4239

200 CASE PATT. NO.


280 180A164 UPPER (485)
60% 180A163 LOWER (485)
70%
75%
240 245 PSI 80%

225 PSI
150
80%
200
200 PSI
(METERS of H 2O)

175 PSI
160
160 PSI

140
P.S.I.

100 75%
140 PSI
120
750 1125 to
245
80
50 P.S.I.
BHP
40 400
BHP FOR 245 PSI CURVE

200
BHP FOR 140 PSI CURVE

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000
L/S 20 40 60 80 100 120
M 3/HR 75 150 225 300 375 450
PC-153362

SIZE : 4-491-11A MODEL: 491 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A723
67%
160 60% 65% 72%

70% CASE PATT. NO. 190A010 UPPER


74%
190A009 LOWER
100 140 143 PSI
78%

74%
120
80 72%
70%
(METERS of H 2O)

100 67%
100 PSI
65%

100
P.S.I.

60
80
750 to
60
143
40 1125
P.S.I.
BHP
BHP FOR 143 PSI CURVE
40 120

BHP FOR 100 PSI CURVE 60

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 75 150 225 300 375
PC-168440
Section 912 Page 412 750 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 412
Dated June 1999

SIZE : 4-491-11A MODEL: 491 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A723

175 CASE PATT. NO. 190A010 UPPER


240 60% 65% 190A009 LOWER
70%
75%
77%
221 PSI 80%
150
81%
200
80%

125 77%
(METERS of H 2O)

75%
160

144
P.S.I.

100
144 PSI

to 120 750

221
BHP
75
1125 250

P.S.I. 80
BHP FOR 221 PSI CURVE
200
50
150
BHP FOR 144 PSI CURVE
100

50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800
L/S 20 40 60 80 100
M 3/HR 75 150 225 300 375
PC-168442

SIZE : 4-491-11A MODEL: 491 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A723

175 CASE PATT. NO. 190A010 UPPER


240 190A009 LOWER
60% 65% 70%
75%
77%
225 PSI 80%
150
80%
200 78%
750 75%
125 1125
(METERS of H 2O)

160
P.S.I.

100

225 120
P.S.I. 75

BHP
80 BHP FOR 225 PSI CURVE 250
50
200

150

100

50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800
L/S 20 40 60 80 100
M 3/HR 75 150 225 300 375
PC-168780
750 G.P.M. 912 SERIES Section 912 Page 413
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 413
Dated June 1999

SIZE : 4-491-11C MODEL: 491 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A705
240
160

70% CASE PATT. NO. 190A010 UPPER


75% 190A009 LOWER
200 77%
200 PSI

120
77%
160
75%
(METERS of H 2O)

145 PSI
70%

120
145
750
P.S.I.

80

1125 to
200
80

40 BHP
200
P.S.I.
BHP FOR 200 PSI CURVE
150

100
BHP FOR 145 PSI CURVE
50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 75 150 225 300 375
PC-168441

SIZE : 4-491-14C MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A704
80

CASE PATT. NO. 190A008 UPPER


100 70% 190A007 LOWER
75%
78%
90 PSI
60
80 78%

75%
(METERS of H 2O)

60 70%
40
55
P.S.I.

55 PSI

750
to
40
90
20 1125 P.S.I.
20

BHP
BHP FOR 90 PSI CURVE 80

40
BHP FOR 55 PSI CURVE
0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 80 160 240 320 400
PC-168443
Section 912 Page 414 750 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 414
Dated June 1999

SIZE : 4-492-18 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A726
160

CASE PATT. NO. 190A006 UPPER


200 190A005 LOWER

120
160

50%
60%
(METERS of H 2O)

70%
120 125 PSI
80
100 70%
P.S.I.

111 PSI

100 PSI

to 80 750

125 1125
40
P.S.I.
40
BHP
BHP FOR 125 PSI CURVE 120
100
80
BHP FOR 100 PSI CURVE 60
40
20
0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 20 40 60 80 100
M 3/HR 80 160 240 320
PC-168444

SIZE : 5-495-15 MODEL: 495 IMPELLER : Enclosed R. P. M. : 1770


50% 55% IMP. PATT. NO. 444A728&9
60%
65%

180 70% CASE PATT. NO. 190A045 UPPER


125 180 PSI 71% 190A044 LOWER

72%
160
72%

155 PSI
71%
100
140 70%
(METERS of H 2O)

125
P.S.I.

120 125 PSI

to 750
75
180 100

P.S.I.
80
1125 BHP
50 BHP FOR 180 PSI CURVE
150

60 100
BHP FOR 125 PSI CURVE
50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 15 30 45 60 75 90 105
M 3/HR 80 160 240 320 400
PC-168445
750 G.P.M. 912 SERIES Section 912 Page 415
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 415
Dated June 1999

SIZE : 5-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


180 IMP. PATT. NO. 444A708
125

160 CASE PATT. NO. 190A016 UPPER


65% 190A015 LOWER
70%
100 75%
140 77%
140 PSI

78%
120 77%
75%
75
(METERS of H 2O)

70%
100
65%
90
P.S.I.

90 PSI
80
50 to
60
750

1125
140
P.S.I.
40
25
BHP
BHP FOR 140 PSI CURVE
20 160

120

80
BHP FOR 90 PSI CURVE
40

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000
L/S 20 40 60 80 100 120
M 3/HR 100 200 300 400
PC-168446

SIZE : 6-491-12A MODEL: 491 IMPELLER : Enclosed R. P. M. : 3565


240 IMP. PATT. NO. 444A709

CASE PATT. NO. 190A018 UPPER


300 60% 190A017 LOWER
65%
200 70%
75%
266 PSI
250
76%
160 75%
(METERS of H 2O)

200 70%

180
P.S.I.

120 180 PSI 65%

150 750
60% to
266
80 BHP P.S.I.
100 1125 250

200
BHP FOR 266 PSI CURVE
150

BHP FOR 180 PSI CURVE 100

50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600
L/S 15 30 45 60 75 90 105
M 3/HR 75 150 225 300 375
PC-168447
Section 912 Page 416
Date April 2000
Supersedes Section 912 Page 416
Dated June 1999

THIS PAGE LEFT INTENTIONALLY BLANK


1000 G.P.M. 912 SERIES Section 912 Page 417
Date June 2002
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 417
Dated November 2001

SIZE : 5-481-11B / 5-483-11B MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A177
200 280
CASE PATT. NO.
180A263 UPPER (ALL)
180A262 LOWER (481)
240 180A264 LOWER (483)
60%
70% 75%
150
200 80%
200 PSI

185 PSI 83%


(METERS of H 2O)

160 165 PSI

100 150 PSI 80%


120
P.S.I.

135 PSI 75%


120
120 PSI 70%
to
80
200
50
1000 P.S.I.
BHP
1500
40 200

BHP FOR 200 PSI CURVE

100
BHP FOR 120 PSI CURVE

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
L/S 25 50 75 100 125
M 3/HR 100 200 300 400 500
PC-123055

SIZE : 5-481-11C / 5-483-11C MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A184
240
160 CASE PATT. NO.
180A263 UPPER (ALL)
180A262 LOWER (481)
200 180A264 LOWER (483)
60% 70%
75%
120 80%
160
160 PSI
150 PSI 83%

135 PSI 80%


(METERS of H 2O)

120
80 120 PSI 75%
105 PSI 70% 90
P.S.I.

80
90 PSI
to
40 160
40 1000
1500
P.S.I.
BHP
200
BHP FOR 160 PSI CURVE

BHP FOR 90 PSI CURVE 100

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
L/S 25 50 75 100 125
M 3/HR 100 200 300 400 500
PC-123056
Section 912 Page 418 1000 G.P.M. 912 SERIES
Date June 2002
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 418
Dated April 2000

SIZE : 5-481-15 / 5-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A328

CASE PATT. NO.


120 180A041 UPPER (ALL)
80 180A042 LOWER (481)
60% 180A080 LOWER (483)
70%
100
80%

60 90 PSI 82%
80 82%
75 PSI 80%
(METERS of H 2O)

50 40
60
60 PSI 70%
P.S.I.

to 40
50 PSI 60%

90 20 1000

P.S.I. 20 BHP
1500
100

BHP FOR 90 PSI CURVE

50

BHP FOR 50 PSI CURVE

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
L/S 25 50 75 100 125 150
M 3/HR 100 200 300 400 500
PC-119725

SIZE : 5-481-17 / 5-483-17 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A329
70%
CASE PATT. NO.
125 PSI
120 80% 180A041 UPPER (ALL)
180A044 LOWER (481)
80 180A081 LOWER (483)

100 100 PSI 80%

90 PSI
60 75%
80
2O)
(METERS of H

90 1000
P.S.I.

to 40
60

125 1500

40
P.S.I.
20 BHP
20 200
BHP FOR 125 PSI CURVE

BHP FOR 90 PSI CURVE


100

400 800 1200 1600 2000 2400 2800 3200 0


U.S. GPM
L/S 40 80 120 160 200
M3/HR 100 200 300 400 500 600 700 800
PC-119726
1000 G.P.M. 912 SERIES Section 912 Page 418.1
Date July 2007
ELECTRIC MOTOR DRIVE

SIZE : 6-481-11HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A479
300
200 CASE PATT. NO. 180A492 UPPER
180A493 LOWER
250
40% 50%
60% 65%
70%
75%
150 218 PSI 80%
200
(METERS of H2O)

P.S.I.

100
150 88
to
100
BHP
218
88 PSI
300 P.S.I.
50 1000 1500 BHP FOR 219 PSI CURVE
250
50
200
150

0 0 BHP FOR 88 PSI CURVE 100


50
0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
PC - 186044

SIZE : 6-481-14HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A447
500

CASE PATT. NO.


180A489 UPPER (481)
300 180A490 LOWER (481)
400

40% 50% 60%


65% 70%
300 75% 80%
200
(METERS of H2O)

287 PSI
P.S.I.

200 154
100 154 PSI
to
100
1000 287
1500 BHP
500
P.S.I.
BHP FOR 287 PSI CURVE 400
0 0
300

BHP FOR 145 PSI CURVE 200

100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
DRAWN BY: APPROVED BY: DATE : 11/4/04 PC - 185603
Section 912 Page 418.2
Date February 2005

THIS PAGE LEFT INTENTIONALLY BLANK


1000 G.P.M. 912 SERIES Section 912 Page 419
ELECTRIC MOTOR DRIVE Date June 2008
Supersedes Section 912 Page 419
Dated June 1999

SIZE : 6-481-11 / 6-483-11 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A327

50 70 CASE PATT. NO.


180A045 UPPER (ALL)
180A046 LOWER (481)
180A082 LOWER (483)
60
70%
40
80%
85%
50
50 PSI 87%

30 45 PSI
87%
(METERS of H 2O)

40
40 PSI 85%

40
80%
P.S.I.

30
20

1000
to
20 1500 50
10
P.S.I.
10
BHP
BHP FOR 50 PSI CURVE
50

BHP FOR 40 PSI CURVE 25

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
L/S 25 50 75 100 125 150
M 3/HR 100 200 300 400 500
PC-117433

149
to
202
P.S.I.
Section 912 Page 419.1 1000 G.P.M. 912 SERIES
Date February 2011
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 419.1
Dated June 2008

SIZE: 6-485-16B MODEL: 485 IMPELLER : Enclosed R. P. M. : 1770


250 IMP. PATT. NO. 444A496 & 444A497
CASE PATT. NO. Upper : 180A511
Lower : 180A512
40%
50%
100 60%
200 65%

188 PSI 70%

170 PSI

150
50 144 PSI
(METERS of H2O)

75%

144
P.S.I.

1000 GPM
100
to
188
1500 GPM

P.S.I. 50
BHP
200

BHP FOR 188 PSI CURVE 150


BHP FOR 170 PSI CURVE
BHP FOR 144 PSI CURVE 100

50

0
U.S. GPM 500 1000 1500 2000 2500
L/S 50 100 150
M3/HR 200 400
PC-204622

SIZE : 6-485-17A MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 4238 & 4239

200 CASE PATT. NO.


280 180A164 UPPER (485)
60% 180A163 LOWER (485)
70%
75%
240 80%
240 PSI

225 PSI
150
80%
200
200 PSI
(METERS of H 2O)

175 PSI
160
160 PSI

130
P.S.I.

100 75%

to 120 130 PSI

1000
240
80
P.S.I. 50 1500

BHP
40 400
BHP FOR 240 PSI CURVE

200
BHP FOR 130 PSI CURVE

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000
L/S 20 40 60 80 100 120
M 3/HR 75 150 225 300 375 450
PC-153363
Section 912 Page 419.2
Date June 1999
Supersedes Section 912 Page 419.2

THIS PAGE LEFT INTENTIONALLY BLANK


Section 912 Page 420 1000 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 420
Dated June 1999

SIZE : 5-492-18 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A730
100 140
68%
CASE PATT. NO. 190A047 UPPER
73% 190A046 LOWER
125 PSI
120
80

73%
100 104 PSI
70%
68%
60
(METERS of H 2O)

80

50
80 PSI
P.S.I.

to 40
60 62 PSI

125 50 PSI

P.S.I. 40
1000
20
1500
20
BHP

BHP FOR 125 PSI CURVE 150

100
BHP FOR 50 PSI CURVE
50

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800
L/S 20 40 60 80 100 120
M 3/HR 80 160 240 320 400
PC-168448

SIZE : 5-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


180 IMP. PATT. NO. 444A708
125

160 CASE PATT. NO. 190A016 UPPER


65% 190A015 LOWER
70%
100 75%
140 77%
135 PSI
78%
120 77%
75%
75
(METERS of H 2O)

70%
100
85 65%
P.S.I.

to 80 85 PSI

50
135 60
1000

P.S.I.
40 1500
25
BHP
BHP FOR 135 PSI CURVE
20 160

120

80
BHP FOR 85 PSI CURVE
40

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000
L/S 20 40 60 80 100 120
M 3/HR 100 200 300 400
PC-168449
1000 G.P.M. 912 SERIES Section 912 Page 421
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 421
Dated June 1999

SIZE : 6-495-17 MODEL: 495 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A712&3

60%
180 65%
70% CASE PATT. NO. 190A024 UPPER
72% 190A023 LOWER
240 244 PSI
75%
160
76%

76%
140 200
198 PSI 75%
(METERS of H 2O)

72%
120 70%
144
P.S.I.

160

100
144 PSI
to
120
1000
244
80 P.S.I.
1500
BHP FOR 244 PSI CURVE BHP
60
80 320
240
BHP FOR 144 PSI CURVE
160
80
0
U.S. GPM 400 800 1200 1600 2000 2400 2800
L/S 25 50 75 100 125 150 175
M 3/HR 100 200 300 400 500 600
PC-168450
Section 912 Page 422
Date April 2000
Supersedes Section 912 Page 422
Dated June 1999

THIS PAGE LEFT INTENTIONALLY BLANK


1250 G.P.M. 912 SERIES Section 912 Page 422.1
Date July 2007
ELECTRIC MOTOR DRIVE

SIZE : 6-481-11HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A479
300
200 CASE PATT. NO. 180A492 UPPER
180A493 LOWER
250
40% 50%
60% 65%
70%
75%
150 80%
216 PSI
200
(METERS of H2O)

80%
P.S.I.

100
150
132
132 PSI
to
100
1250 1875 BHP 216
50
BHP FOR 216 PSI CURVE 300
P.S.I.
250
50
200
BHP FOR 130 PSI CURVE 150

0 0 100
50
0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
DRAWN BY: APPROVED BY: DATE : PC - 186045

SIZE : 6-481-14HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A447
500

CASE PATT. NO.


180A489 UPPER (481)
300 180A490 LOWER (481)
400

40% 50% 60%


65% 70%
300 75% 80% 80%
200 75%
70%
(METERS of H2O)

287 PSI
65%
P.S.I.

200
145
100 145 PSI to
1250
100
BHP
287
1875 500 P.S.I.
BHP FOR 287 PSI CURVE
400
0 0
300

BHP FOR 145 PSI CURVE 200

100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
DRAWN BY: APPROVED BY: DATE : 11/4/04 PC - 185604
Section 912 Page 422.2
Date February 2005

THIS PAGE LEFT INTENTIONALLY BLANK


1250 G.P.M. 912 SERIES Section 912 Page 423
Date April 2003
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 423
Dated April 2000

SIZE : 6-481-15 / 6-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A330
80
CASE PATT. NO.
180A047 UPPER (ALL)
60% 70% 180A048 LOWER (481)
100
180A083 LOWER (483)
80%
96 PSI

83%
60
85 PSI
80
83%
75 PSI
(METERS of H 2O)

80%

65 PSI 55
P.S.I.

60 70%
40
55 PSI
to
96
40 P.S.I.
1250
20 1875 BHP
BHP FOR 96 PSI CURVE 150

100
BHP FOR 55 PSI CURVE
50

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 40 80 120 160 200
M 3/HR 100 200 300 400 500 600 700
PC-147678

SIZE : 6-481-15C / 6-483-15C MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A439
80
CASE PATT. NO.
60% 65% 180A047 UPPER (ALL)
70% 180A048 LOWER (481)
100 180A083 LOWER (483)
95 PSI 76%

60 85 PSI
80 78%

75 PSI
2O)
(METERS of H

76%

55
P.S.I.

65 PSI
60
40
55 PSI to
95
40 P.S.I.
1250
20 1875 BHP

BHP FOR 95 PSI CURVE 150

100
BHP FOR 55 PSI CURVE
50

400 800 1200 1600 2000 2400 2800 3200 0


U.S. GPM
L/S 40 80 120 160 200
M3/HR 100 200 300 400 500 600 700
PC-179386
Section 912 Page 423.1 1250 G.P.M. 912 SERIES
Date June 2008
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 423.1
Dated April 2003

139
to
189
P.S.I.
Section 912 Page 423.2
Date July 2008
Supersedes Section 912 Page 423.2

THIS PAGE LEFT INTENTIONALLY BLANK


Section 912 Page 424 1250 G.P.M. 912 SERIES
Date May 2004
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 424
Dated April 2003

SIZE : 6-481-18B / 6-483-18B MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A131
60%
150 70%
75%
100 CASE PATT. NO.
140 PSI 80% 180A217 UPPER (ALL)
180A218 LOWER (481)
180A260 LOWER (483)
125 83%

80 117 PSI

80%
100 100 PSI
(METERS of H2O)

75%
70%
60
75
100
P.S.I.

60%
1250
to 40

140 50
1875
P.S.I. BHP FOR 140 PSI CURVE
BHP
20
25 200

BHP FOR 100 PSI CURVE

100

400 800 1200 1600 2000 2400 2800 3200 0


U.S. GPM
L/S 40 80 120 160 200
M3/HR 100 200 300 400 500 600 700
PC-147680

SIZE : 6-481-20 / 6-483-20 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 2-7-113
160
CASE PATT. NO.
180A049 UPPER (ALL)
180A050 LOWER (481)
200
180A084 LOWER (483)

60%
120 70%
75%
168 PSI
160 80%
(METERS of H 2O)

83%

85 133 PSI
83%
P.S.I.

80%
to
120
80
75%

168 104 PSI

70%
P.S.I. 80 85 PSI
BHP
1250 400
40
BHP FOR 168 PSI CURVE
1875 300

200
BHP FOR 85 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500
L/S 40 80 120 160 200 240
M 3/HR 200 400 600 800
PC-147682
1250 G.P.M. 912 SERIES Section 912 Page 425
Date April 2003
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 425
Dated April 2000

SIZE : 8-481-12 / 8-483-12 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A330

CASE PATT. NO.


60 180A055 UPPER (ALL)
180A056 LOWER (481)
80
180A087 LOWER (483)

45
40% 50%
60 60%
70%
75%
(METERS of H 2O)

53 PSI

80%

45
30 82%
P.S.I.

45 PSI
40
82%

1250
80% to
15
1875 75% 53
20
BHP P.S.I.
80
BHP FOR 53 PSI CURVE

60

BHP FOR 45 PSI CURVE 40

20

0
U.S. GPM 500 1000 1500 2000 2500 3000
L/S 40 80 120 160 200
M 3/HR 100 200 300 400 500 600 700
PC-147676

SIZE : 8-481-21 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1775


IMP. PATT. NO. 444A279

CASE PATT. NO.


240 180A166 UPPER (ALL)
180A167 LOWER (481)
160
60% 70% 75% 82%
80%
200
195 PSI
83%

82%
120 80%
(METERS of H 2O)

160 166 PSI


75%

136
P.S.I.

70%
to
136 PSI
120
80
195
80 1250 1875
P.S.I.
BHP
500
40
400
40 BHP FOR 195 PSI CURVE
300

200
BHP FOR 136 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 40 80 120 160 200 240 280
M 3/HR 200 400 600 800 1000
PC-147684
Section 912 Page 426 1250 G.P.M. 912 SERIES
Date April 2003
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 426
Dated April 2000

SIZE : 5-491-14A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1780


IMP. PATT. NO. 444A707
100 140

CASE PATT. NO. 190A014 UPPER


120 190A013 LOWER

75
100 65% 72%
78% 81%
83%

80 84 PSI 83%
(METERS of H 2O)

50 81%
78%
60 72%
64
64 PSI
P.S.I.

65%
1250
to 40
25
84 1875

P.S.I. 20

BHP
BHP FOR 84 PSI CURVE 120

60
BHP FOR 64 PSI CURVE

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
L/S 25 50 75 100 125
M 3/HR 100 200 300 400 500
PC-168451

SIZE : 5-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1780


IMP. PATT. NO. 444A708

180
CASE PATT. NO. 190A016 UPPER
120 190A015 LOWER
160 60%
65%
70%
75%
100 77%
140
134 PSI 78%

77%
(METERS of H 2O)

120
119 80 119 PSI 75%

to
P.S.I.

100 70%

134
65%
60 1250 60%
80
P.S.I.
1875
60 BHP
40
200
BHP FOR 134 PSI CURVE
160

120
BHP FOR 119 PSI CURVE
80

40

0
U.S. GPM 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
L/S 20 40 60 80 100 120 140
M 3/HR 100 200 300 400 500
PC-168529
1500 G.P.M. 912 SERIES Section 912 Page 426.1
Date February 2005
ELECTRIC MOTOR DRIVE

SIZE : 6-481-11HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A479
300
200 CASE PATT. NO. 180A492 UPPER
180A493 LOWER
250
40% 50%
60% 65%
70%
75%
150 80%
200 216 PSI
(METERS of H2O)

80%
P.S.I.

150
100 142 PSI 142
to
100
1500 2250
BHP 216
BHP FOR 216 PSI CURVE 300
50 P.S.I.
250
50
BHP FOR 142 PSI CURVE 200
150

0 0 100
50
0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
DRAWN BY: APPROVED BY: DATE : PC - 186046

SIZE : 6-481-14HH MODEL: 480 IMPELLER : Enclosed R. P. M. : 3560


IMP. PATT. NO. 444A447
500

CASE PATT. NO.


180A489 UPPER (481)
300 180A490 LOWER (481)
400

40% 50% 60%


65% 70%
300 75% 80% 80%
200 75%
70%
(METERS of H2O)

283 PSI 65%


P.S.I.

200 158
158 PSI
to
100

100
1500 283
2250
BHP P.S.I.
500
BHP FOR 283 PSI CURVE
400
0 0
300
BHP FOR 158 PSI CURVE
200

100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 50 100 150 200
M3/HR 100 200 300 400 500 600 700
DRAWN BY: APPROVED BY: DATE : 11/4/04 PC - 185604A
Section 912 Page 426.2
Date February 2005

THIS PAGE LEFT INTENTIONALLY BLANK


1500 G.P.M. 912 SERIES Section 912 Page 427
Date April 2003
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 427
Dated April 2000

SIZE : 6-481-15 / 6-483-15 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A330
80
CASE PATT. NO.
180A047 UPPER (ALL)
60% 70% 180A048 LOWER (481)
100
180A083 LOWER (483)
80%

90 PSI 83%
60
80
80 PSI
83%
(METERS of H 2O)

80%
70 PSI

50
P.S.I.

60 70%
to
60 PSI
40

50 PSI
90
40 P.S.I.
1500
20 BHP
2250 BHP FOR 90 PSI CURVE 150

100
BHP FOR 50 PSI CURVE
50

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 40 80 120 160 200
M 3/HR 100 200 300 400 500 600 700
PC-117438

SIZE : 6-481-15C / 6-483-15C MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A439
80
CASE PATT. NO.
60% 65% 180A047 UPPER (ALL)
70% 180A048 LOWER (481)
100 180A083 LOWER (483)
76%
91 PSI
60
80 78%
80 PSI
2O)
(METERS of H

71 PSI 76%

71
P.S.I.

60
40 to
1500 91
40 P.S.I.
2250
20 BHP
BHP FOR 91 PSI CURVE 150

100
BHP FOR 71 PSI CURVE
50

400 800 1200 1600 2000 2400 2800 3200 0


U.S. GPM
L/S 40 80 120 160 200
M3/HR 100 200 300 400 500 600 700
PC-179387
Section 912 Page 428 1500 G.P.M. 912 SERIES
Date July 2007
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 428
Dated April 2003

SIZE : 6-481-18B / 6-483-18B MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A181
60%
150 70%
75%
100 CASE PATT. NO.
80% 180A217 UPPER (ALL)
180A218 LOWER (481)
125 130 PSI 180A260 LOWER (483)
83%

80
110 PSI
80%
100
95 PSI 75%
(METERS of H 2O)

60 70%

95 75
P.S.I.

60%

to 40
1500

130 50

P.S.I. 2250
BHP
20
25 BHP FOR 130 PSI CURVE 200

BHP FOR 95 PSI CURVE

100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200
L/S 40 80 120 160 200
M 3/HR 100 200 300 400 500 600 700
PC-123058

SIZE : 6-481-20 / 6-483-20 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 2-7-113
160
CASE PATT. NO.
180A049 UPPER (ALL)
180A050 LOWER (481)
200
180A084 LOWER (483)

60%
120 70%
75%
160 165 PSI 80%
(METERS of H 2O)

83%

80 83%
P.S.I.

130 PSI 80%


to
120
80
75%

165 100 PSI


70%

P.S.I. 80 80 PSI
BHP
1500 400
40
BHP FOR 165 PSI CURVE
2250 300

200
BHP FOR 80 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500
L/S 40 80 120 160 200 240
M 3/HR 200 400 600 800
PC-117440A
1500 G.P.M. 912 SERIES Section 912 Page 429
Date April 2003
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 429
Dated April 2000

SIZE : 8-481-12 / 8-483-12 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A330

CASE PATT. NO.


60 180A055 UPPER (ALL)
180A056 LOWER (481)
80
180A087 LOWER (483)

45
60 40% 50%
60%
70%
(METERS of H 2O)

75%
50 PSI
80%
30
40
P.S.I.

40 82%
40 PSI

to
82%
80%
1500
75% 50
15 20 2250
BHP
P.S.I.
80
BHP FOR 50 PSI CURVE

60

40
BHP FOR 40 PSI CURVE
20

0
U.S. GPM 500 1000 1500 2000 2500 3000
L/S 40 80 120 160 200
M 3/HR 100 200 300 400 500 600 700
PC-117437

SIZE : 8-481-21 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A279

CASE PATT. NO.


240 180A166 UPPER (ALL)
180A167 LOWER (481)
160
60% 70% 75% 82%
80%
200
83%
195 PSI
82%
120 80%
(METERS of H 2O)

160 165 PSI


75%

135
P.S.I.

135 PSI
70%

80
120
to
195
80 1500 2250
BHP P.S.I.
500
40
400
40 BHP FOR 195 PSI CURVE
300

200
BHP FOR 135 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 40 80 120 160 200 240 280
M 3/HR 200 400 600 800 1000
PC-144927A
Section 912 Page 430 1500 G.P.M. 912 SERIES
Date February 2005
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 430
Dated April 2003

SIZE : 6-492-10 MODEL: 492 IMPELLER : Enclosed R. P. M. : 3550


IMP. PATT. NO. 444A711
50% 60% 67%
65% 70%
180 CASE PATT. NO. 190A022 UPPER
125 75%
175 PSI 79% 80% 190A021 LOWER

160

80%
100 79%
140
75%
136 PSI
(METERS of H 2O)

70%
120

100
P.S.I.

67%
75

to 100
100 PSI 60%

175
80
P.S.I. 50
1500
60
BHP
2250 BHP FOR 175 PSI CURVE
300

200

BHP FOR 100 PSI CURVE 100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200 3600
L/S 40 80 120 160 200 240
M 3/HR 200 400 600 800
PC-168453
2000 G.P.M. 912 SERIES Section 912 Page 431
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 431
Dated June 1999

SIZE : 6-481-15B / 6-483-15B MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A143
150
100 CASE PATT. NO.
180A047 UPPER (ALL)
180A048 LOWER (481)
125 180A083 LOWER (483)
60%
70%
75%
80 80%

100 83%
100 PSI

80%
(METERS of H 2O)

90 PSI
60

80
75 80 PSI
75%
P.S.I.

to
70%
40
50
2000 100
3000
BHP
P.S.I.
20
25 BHP FOR 100 PSI CURVE 200

BHP FOR 80 PSI CURVE 100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200 3600
L/S 50 100 150 200
M 3/HR 200 400 600 800
PC-123057

SIZE : 6-481-18C / 6-483-18C MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A183
160

CASE PATT. NO.


200 180A217 UPPER (ALL)
180A218 LOWER (481)
180A260 LOWER (483)
120
70% 75%
160 80% 85%

140 PSI
85%

120 80%
(METERS of H 2O)

80 120 PSI
75%
105 PSI
70%

100
100 PSI
P.S.I.

80 60%

40 2000 to
40
3000
140
P.S.I.
BHP
BHP FOR 140 PSI CURVE 300

BHP FOR 100 PSI CURVE


150

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000
L/S 40 80 120 160 200 240
M 3/HR 200 400 600 800
PC-123059
Section 912 Page 432 2000 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 432
Dated June 1999

SIZE : 6-481-20 / 6-483-20 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 2-7-113
160
CASE PATT. NO.
180A049 UPPER (ALL)
180A050 LOWER (481)
200
180A084 LOWER (483)

60%
120 70%
75%
160 80%
(METERS of H 2O)

150 PSI
83%
83%

123
P.S.I.

120 80%
123 PSI
80
to 75%

150 70%
80
P.S.I. BHP
2000 400
40 3000

BHP FOR 150 PSI CURVE 300

200
BHP FOR 123 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500
L/S 40 80 120 160 200 240
M 3/HR 200 400 600 800
PC-117444A

SIZE : 8-481-17B / 8-483-17B MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A137
200
CASE PATT. NO.
180A059 UPPER (ALL)
180A060 LOWER (481)
120
180A089 LOWER (483)
160

70%
80% 85%
88%
130 PSI
120
80 88%
(METERS of H 2O)

85%
100 PSI

53 80
80%
P.S.I.

80 PSI

to 40
130 40
53 PSI

2000
P.S.I. 3000
BHP
400

BHP FOR 130 PSI CURVE

200
BHP FOR 53 PSI CURVE

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 50 100 150 200 250 300
M 3/HR 200 400 600 800 1000
PC-149176
2000 G.P.M. 912 SERIES Section 912 Page 433
Date June 2008
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 433
Dated April 2000

SIZE : 8-481-21 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A279

CASE PATT. NO.


240 180A166 UPPER (ALL)
180A167 LOWER (481)
160
60% 70% 75% 82%
80%
200
195 PSI
83%

82%
120 80%
(METERS of H 2O)

160
155 PSI 75%

130
P.S.I.

70%
130 PSI

to
120
80

195
80 2000 3000 BHP
P.S.I.
500
40
400
40 BHP FOR 195 PSI CURVE
300

200
BHP FOR 130 PSI CURVE
100

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 40 80 120 160 200 240 280
M 3/HR 200 400 600 800 1000
PC-144928

SIZE: 8-481-24 MODEL: 480 TYPE : ELECTRIC IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A797
300
CASE PATT. NO. 180A509 UPPER (481)
200 180A510 LOWER (481)

250
40% 50%
60% 65%
70%
72%
150 214 PSI 75%
200
(METERS of H 2O)

167
P.S.I.

167 PSI

150 2000
100 3000
to
214
100
BHP P.S.I.
BHP FOR 214 PSI CURVE 600
50
500
50 BHP FOR 167 PSI CURVE 400
300
200
100
0
U.S. GPM 1000 2000 3000 4000 5000
L/S 100 200 300
M3/HR 300 600 900 1200
PC- 196151
Section 912 Page 434 2000 G.P.M. 912 SERIES
Date June 2008
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 434
Dated April 2000

SIZE : 6-491-19A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A722

180 CASE PATT. NO. 190A038 UPPER


190A037 LOWER
120
74%
78%
160
80%
155 PSI
82%
100
140 82%
(METERS of H 2O)

115 80%
P.S.I.

78%
to
120
80
115 PSI 74%
155
100
P.S.I. 2000

60
80
BHP
3000 400
BHP FOR 155 PSI CURVE
300

200
BHP FOR 115 PSI CURVE
100

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200 3600
L/S 40 80 120 160 200
M 3/HR 150 300 450 600 750
PC-168455
2500 G.P.M. 912 SERIES Section 912 Page 435
Date June 2008
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 435
Dated June 1999

SIZE : 8-481-17B / 8-483-17B MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A137
200
CASE PATT. NO.
180A059 UPPER (ALL)
180A060 LOWER (481)
120
180A089 LOWER (483)
160
60%
70%
80%
85%
130 PSI
87%
120 87%
80
85%
(METERS of H 2O)

100 PSI
80%
80
75
P.S.I.

75 PSI

40 to
40 2500
3750 130
P.S.I.
BHP
400

BHP FOR 130 PSI CURVE

BHP FOR 75 PSI CURVE 200

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 50 100 150 200 250 300
M 3/HR 200 400 600 800 1000
PC-117445A

SIZE : 8-481-21A MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A370
240
CASE PATT. NO.
160
60% 180A166 UPPER (ALL)
70%
75% 180A167 LOWER (481)
80%
200 82%

193 PSI
82%
120 80%
160
75%
155 PSI
(METERS of H 2O)

123
120 123 PSI
P.S.I.

80

to
80 2500
193
3750
40 P.S.I.
40

BHP
BHP FOR 193 PSI CURVE 600

400

200
BHP FOR 123 PSI CURVE
0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500
L/S 50 100 150 200 250 300
M 3/HR 200 400 600 800 1000
PC-153774
Section 912 Page 435.1 2500 G.P.M. 912 SERIES
Date June 2008
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 435.1
Dated June 1999

SIZE: 8-481-24 MODEL: 480 TYPE : ELECTRIC IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A797
300
CASE PATT. NO. 180A509 UPPER (481)
200 180A510 LOWER (481)

250
40% 50%
60% 65%
70%
72%
75%
150 215 PSI
200
(METERS of H2O)

75%

158
P.S.I.

160 PSI
150
to 100 2500

215 3750

P.S.I. 100
BHP

BHP FOR 215 PSI CURVE 600


50
500
BHP FOR 160 PSI CURVE
50 400
300
200
100
0
U.S. GPM 1000 2000 3000 4000 5000 6000
L/S 100 200 300
M3/HR 250 500 750 1000 1250
PC- 196155
Section 912 Page 435.2
Date June 1999
Supersedes Section 912 Page 435.2

THIS PAGE LEFT INTENTIONALLY BLANK


Section 912 Page 436 2500 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 436
Dated June 1999

SIZE : 8-491-14A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A719

120 CASE PATT. NO. 190A032 UPPER


80 190A031 LOWER

100

60
80
(METERS of H 2O)

60 78%
40 70%
75% 77%
P.S.I.

77%

50 40
50 PSI 79%
78%
75%
70%
P.S.I. 20 2500

20 3750

BHP
BHP FOR 50 PSI CURVE 120

60

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200 3600 4000
L/S 50 100 150 200 250
M 3/HR 150 300 450 600 750 900
PC-168457

SIZE : 8-491-14A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A719

90
CASE PATT. NO. 190A032 UPPER
60 190A031 LOWER
70%
80 75%
80%
75 PSI 84%
50 70
86%

86%
(METERS of H 2O)

60

55
40 84%
55 PSI
P.S.I.

80%
to
50
2500

75 30
40

P.S.I. 3750
30
20
BHP
BHP FOR 75 PSI CURVE 200

100
BHP FOR 55 PSI CURVE

0
U.S. GPM 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 4800
L/S 50 100 150 200 250 300
M 3/HR 200 400 600 800 1000
PC-168458
2500 G.P.M. 912 SERIES Section 912 Page 437
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 437
Dated June 1999

SIZE : 8-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A720
240
160
CASE PATT. NO. 190A034 UPPER
190A033 LOWER
200

120
160
70% 75%
(METERS of H 2O)

80%
82%
135 PSI
84%
120
P.S.I.

80 84%
82%

2500
80%
75%
135
80
3750 70%
P.S.I.
40
BHP
40 400
BHP FOR 135 PSI CURVE

200

0
U.S. GPM 600 1200 1800 2400 3000 3600 4200 4800 5400
L/S 80 160 240 320
M 3/HR 200 400 600 800 1000 1200
PC-168459
Section 912 Page 438 3000 G.P.M. 912 SERIES
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 438
Dated June 1999

SIZE : 10-481-18 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1775


150 IMP. PATT. NO. 444A146
200
CASE PATT. NO.
180A223 UPPER (ALL)
125 180A224 LOWER (481)
* MAX. FM RATING 140 PSI
50%
160 60%
70% 75%
100 80%
145 PSI*
85% 86%
135 PSI
87%
120 125 PSI
(METERS of H 2O)

75 110 PSI

99 99 PSI
P.S.I.

to 80

145
50 3000 4500 BHP

600
P.S.I. BHP FOR 145 PSI CURVE
40 500
25
400
BHP FOR 99 PSI CURVE
300

200

100

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000
L/S 80 160 240 320 400 480
M 3/HR 400 800 1200 1600
PC-126288B

SIZE : 8-491-14A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A719
96
70%
75%
78% CASE PATT. NO. 190A032 UPPER
60 84 82% 190A031 LOWER
85%

80 PSI 87%

50 72

87%
85%
(METERS of H 2O)

60
60 PSI 82%
60
40
78%
P.S.I.

to 48 75%

80 30

3000
P.S.I. 36
4500

20 BHP
BHP FOR 80 PSI CURVE
24 200

BHP FOR 60 PSI CURVE


100

0
U.S. GPM 600 1200 1800 2400 3000 3600 4200 4800 5400
L/S 80 160 240 320
M 3/HR 200 400 600 800 1000 1200
PC-168556
3000 G.P.M. 912 SERIES Section 912 Page 439
Date April 2000
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 439
Dated June 1999

SIZE : 8-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A720
160

CASE PATT. NO. 190A034 UPPER


190A033 LOWER
100 140
70%
75%
80%
120 82%
80 115 PSI 84%
(METERS of H 2O)

100 104 PSI 84%


82%
80%
104
P.S.I.

60 3000 75%
80
70% to
60 4500
115
40
P.S.I.
BHP
400
BHP FOR 115 PSI CURVE

200
BHP FOR 104 PSI CURVE

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
L/S 75 150 225 300
M 3/HR 200 400 600 800 1000
PC-168460

SIZE : 8-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A720
160

CASE PATT. NO. 190A034 UPPER


190A033 LOWER
100 140 70%
75%
80%
82%
125 PSI
120 84%
120 PSI
80
84%
(METERS of H 2O)

100 82%
3000 80%
120
P.S.I.

60 75%
80 70%
to
4500 125
60
40
P.S.I.
BHP
400
BHP FOR 125 PSI CURVE

BHP FOR 120 PSI CURVE


200

0
U.S. GPM 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
L/S 75 150 225 300
M 3/HR 200 400 600 800 1000
PC-168461
Section 912 Page 440 3000 G.P.M. 912 SERIES
Date February 2005
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 440
Dated April 2000

SIZE : 8-491-18A MODEL: 491 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A720
240
160
CASE PATT. NO. 190A034 UPPER
190A033 LOWER
200

120
160
70% 75%
(METERS of H 2O)

80%
82%
84%
120 130 PSI
84%
P.S.I.

80
82%
80%
130 75%
70%
80
P.S.I. 3000
4500
40
BHP
40 400
BHP FOR 130 PSI CURVE

200

0
U.S. GPM 600 1200 1800 2400 3000 3600 4200 4800 5400
L/S 80 160 240 320
M 3/HR 200 400 600 800 1000 1200
PC-168462

SIZE : 10-481-18D MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A478

120
CASE PATT. NO.
180A495 UPPER
150 40% 50% 60% 180A496 LOWER (481)
65% 70%
75% 80%
138 PSI
90
(METERS of H2O)

100
P.S.I.

90 60 90 PSI

to 3000
4500
138 50
P.S.I. 30 BHP

600
BHP FOR 138 PSI CURVE 500
400
0 0 300
BHP FOR 90 PSI CURVE
200
100
0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000
L/S 100 200 300 400
M3/HR 500 1000 1500
PC - 186075
3000 G.P.M. 912 SERIES Section 912 Page 440.1
Date February 2005
ELECTRIC MOTOR DRIVE

SIZE : 10-492-18 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A721

140 200
CASE PATT. NO. 190A036 UPPER
190A035 LOWER
180
120
160 75% 80%

153 PSI
84%
100 85%
140
84%
(METERS of H 2O)

131 PSI 80%


120
80
100
P.S.I.

75%

100
to
100 PSI

60
80 153
3000
4500 BHP P.S.I.
60 BHP FOR 153 PSI CURVE 600
40

400
BHP FOR 100 PSI CURVE

200

0
U.S. GPM 600 1200 1800 2400 3000 3600 4200 4800 5400 6000 6600
L/S 80 160 240 320 400
M 3/HR 200 400 600 800 1000 1200 1400
PC-168463
Section 912 Page 440.2
Date February 2005

THIS PAGE LEFT INTENTIONALLY BLANK


3500 G.P.M. 912 SERIES Section 912 Page 441
Date February 2005
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 441
Dated May 2004

SIZE : 10-481-18 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1775


150 IMP. PATT. NO. 444A146
200
CASE PATT. NO.
180A223 UPPER (ALL)
125 180A224 LOWER (481)
50%
160 60%
70% 75%
100 80%
140 PSI
85% 86%
135 PSI
87%
120 125 PSI
(METERS of H 2O)

75 110 PSI

98
P.S.I.

98 PSI

50
80
3500
BHP
to
140
5250
600

40
BHP FOR 140 PSI CURVE
500 P.S.I.
25
400
BHP FOR 98 PSI CURVE
300

200

100

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000
L/S 80 160 240 320 400 480
M 3/HR 400 800 1200 1600
PC-126289B

SIZE : 10-481-18D MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A478

120
CASE PATT. NO.
180A495 UPPER
150 40% 50% 60% 65% 180A496 LOWER (481)
70%
75%
80% 85%
135 PSI
90
(METERS of H2O)

100
P.S.I.

60
88
88 PSI

3500
5250 to
50 135
30 BHP
P.S.I.
600
BHP FOR 135 PSI CURVE 500
400
0 0 BHP FOR 88 PSI CURVE 300
200
100
0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000
L/S 100 200 300 400
M3/HR 500 1000 1500
PC - 186076
Section 912 Page 442 3500 G.P.M. 912 SERIES
Date February 2005
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 442
Dated April 2000

SIZE : 10-492-18 MODEL: 492 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A721

140 200
CASE PATT. NO. 190A036 UPPER
190A035 LOWER
180
120
160 75% 80%
84%
100 151 PSI 85%
140
84%
(METERS of H 2O)

94 128 PSI 80%


120
P.S.I.

80
to
75%
100

151
94 PSI

60
80
P.S.I. 3500
BHP
60 600
40 5250

BHP FOR 151 PSI CURVE 400

BHP FOR 94 PSI CURVE 200

0
U.S. GPM 600 1200 1800 2400 3000 3600 4200 4800 5400 6000
L/S 80 160 240 320 400
M 3/HR 200 400 600 800 1000 1200 1400
PC-168464
4000 G.P.M. 912 SERIES Section 912 Page 443
Date July 2007
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 443
Dated February 2005

SIZE : 10-481-18 MODEL: 480 IMPELLER : Enclosed R. P. M. : 1775


IMP. PATT. NO. 444A146
150
100 CASE PATT. NO.
180A223 UPPER (ALL)
40% 180A224 LOWER (481)
50% 60%
125 70%
75%
80%
80 83%
110 PSI
105 PSI
100
95 PSI
(METERS of H 2O)

60

75
4000
95
P.S.I.

to
6000
40
50
110
BHP
P.S.I.
20
25 500
BHP FOR 110 PSI CURVE

BHP FOR 95 PSI CURVE 250

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000
L/S 80 160 240 320 400 480
M 3/HR 400 800 1200 1600
PC-126290

SIZE : 10-481-18D MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A478

120
CASE PATT. NO.
180A495 UPPER
40% 50% 60%
150 65% 180A496 LOWER (481)
70%
75%
80%
85%
134 PSI
90
(METERS of H2O)

100
P.S.I.

60 85 PSI
85
to
4000
6000 134
50
30 BHP P.S.I.
600
BHP FOR 135 PSI CURVE
500
400
0 0 BHP FOR 85 PSI CURVE 300
200
100
0
U.S. GPM 2000 4000 6000 8000 10000 12000
L/S 100 200 300 400 500 600 700
M3/HR 500 1000 1500 2000 2500
PC - 186077
Section 912 Page 444 4000 G.P.M. 912 SERIES
Date February 2005
ELECTRIC MOTOR DRIVE
Supersedes Section 912 Page 444
Dated April 2000

SIZE : 10-491-20 MODEL: 491 IMPELLER : Enclosed R. P. M. : 1785


IMP. PATT. NO. 444A732

240 CASE PATT. NO. 190A049 UPPER


160 190A048 LOWER
70%
78%
200 85%
88%
198 PSI

120 89% 88%


160
85%
(METERS of H 2O)

78%

94 80
120
70%
P.S.I.

to 80
94 PSI

198 40
4000

P.S.I. 40
6000
BHP
BHP FOR 198 PSI CURVE
1000

800

600
BHP FOR 94 PSI CURVE
400

200

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
L/S 100 200 300 400 500 600 700
M 3/HR 400 800 1200 1600 2000 2400
PC-168636
4500 G.P.M. 912 SERIES Section 912 Page 445
Date February 2005
ELECTRIC MOTOR DRIVE

SIZE : 10-481-18D MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A478

120
CASE PATT. NO.
180A495 UPPER
40% 50% 60%
150 65%
70% 180A496 LOWER (481)
75%
80%
85%
90 132 PSI
(METERS of H2O)

100 85%
P.S.I.

80%
60
81 PSI
81
4500
to
50
132
6750
30 BHP P.S.I.
BHP FOR 132 PSI CURVE 600
500
400
0 0 BHP FOR 81 PSI CURVE 300
200
100
0
U.S. GPM 2000 4000 6000 8000 10000 12000
L/S 100 200 300 400 500 600 700
M3/HR 500 1000 1500 2000 2500
PC - 186078

SIZE : 10-491-20 MODEL: 491 IMPELLER : Enclosed R. P. M. : 1785


IMP. PATT. NO. 444A732

240 CASE PATT. NO. 190A049 UPPER


160 190A048 LOWER
70%
78%
200 85%
88%
195 PSI

120 89% 88%


160
85%
(METERS of H 2O)

78%
120
80 70% 90
P.S.I.

80 90 PSI to
40
4500 195
40 6750
BHP
P.S.I.
BHP FOR 195 PSI CURVE
1000

800

600
BHP FOR 90 PSI CURVE
400

200

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
L/S 100 200 300 400 500 600 700
M 3/HR 400 800 1200 1600 2000 2400
PC-168637
Section 912 Page 446 5000 G.P.M. 912 SERIES
Date February 2005
ELECTRIC MOTOR DRIVE

SIZE : 10-481-18D MODEL: 480 IMPELLER : Enclosed R. P. M. : 1770


IMP. PATT. NO. 444A478

120
CASE PATT. NO.
180A495 UPPER
40% 50% 60%
150 65% 180A496 LOWER (481)
70%
75%
80%
85%
90 130 PSI
(METERS of H2O)

100 85%
P.S.I.

80%
91 60 91 PSI

to 5000

130
50
P.S.I. 30 7500 BHP

BHP FOR 130 PSI CURVE 600


500
400
BHP FOR 91 PSI CURVE
0 0 300
200
100
0
U.S. GPM 2000 4000 6000 8000 10000 12000
L/S 100 200 300 400 500 600 700
M3/HR 500 1000 1500 2000 2500
PC - 186079

SIZE : 10-491-20 MODEL: 491 IMPELLER : Enclosed R. P. M. : 1785


IMP. PATT. NO. 444A732
100 140

70% CASE PATT. NO. 190A049 UPPER


78% 190A048 LOWER
120
80 80%

109 PSI
100 81%

60 80%
88 PSI
80 78%
(METERS of H 2O)

88 60
70%
P.S.I.

40
to 5000

109 40
7500

P.S.I. 20
20
BHP

BHP FOR 109 PSI CURVE 500

400

300
BHP FOR 88 PSI CURVE
200

100

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
L/S 100 200 300 400 500 600
M 3/HR 400 800 1200 1600 2000 2400
PC-168638
5000 G.P.M. 912 SERIES Section 912 Page 447
Date February 2005
ELECTRIC MOTOR DRIVE

SIZE : 10-491-20 MODEL: 491 IMPELLER : Enclosed R. P. M. : 1785


IMP. PATT. NO. 444A732

240 CASE PATT. NO. 190A049 UPPER


160 190A048 LOWER
70%
78%
200 85%
88%
195 PSI

120 89% 88%


160
85%
(METERS of H 2O)

78%
120
80
110
70%
P.S.I.

110 PSI

80 to
40 195
P.S.I.
40 5000
BHP
7500 BHP FOR 195 PSI CURVE 1000

800

600
BHP FOR 110 PSI CURVE
400

200

0
U.S. GPM 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000
L/S 100 200 300 400 500 600 700
M 3/HR 400 800 1200 1600 2000 2400
PC-168639
Section 912 Page 448
Date February 2005

THIS PAGE LEFT INTENTIONALLY BLANK

You might also like