DOC.

NO FM-QCC-004

CHECK SHEET INSPECTION


REV. NO 01
REV. DATE 17 January, 2019

PT. DFFI PAGE of

Customer : Part No. : Inspection by :


Job No. : Dwg No. : Inspection Report :
Quantity : pcs Material : ASTM A182 F316/L

Part Name : Standard


Meas. Actual Dimension
SPECTACLE BLIND 3" 300# FF Item No. Position Remark
Device Nominal Tol
(ASME B16.48)
Drawing / Sketch : MTC No V
Visual V

not specified
B Inside Diameter VC 89mm in ASME
B16.48-2005

not specified
O Outside Diameter VC 146mm in ASME
B16.48-2006

not specified
A Centerline Dimension VC 170mm in ASME
B16.48-2007

-0,0mm,
t Thickness VC 9,7mm
+3,0mm

not specified
B Web Width VC 64mm in ASME
B16.48-2007

NOTE :
Measuring tool used : Inspected by Reviewed by
-V = Visual - HG = Height Gauge -SR = Steel Ruller
- VC = Vernier Caliper - BP = Bevel Protactor
- UT = Ultrasonic Thickness
Date : Date :
DOC. NO FM-QCC-004

CHECK SHEET INSPECTION


REV. NO 01
REV. DATE 17 January, 2019

PT. DFFI PAGE of

Customer : Part No. : Inspection by :


Job No. : Dwg No. : Inspection Report :
Quantity : pcs Material : ASTM A182 F316/L

Part Name : Standard


Meas. Actual Dimension
SPECTACLE BLIND 3" 300# FF Item No. Position Remark
Device Nominal Tol
(ASME B16.48)
Drawing / Sketch : MTC No V
Visual V

not specified
B Inside Diameter VC 89mm in ASME
B16.48-2005

not specified
O Outside Diameter VC 146mm in ASME
B16.48-2006

not specified
A Centerline Dimension VC 170mm in ASME
B16.48-2007

-0,0mm,
t Thickness VC 9,7mm
+3,0mm

not specified
B Web Width VC 64mm in ASME
B16.48-2007

NOTE :
Measuring tool used : Inspected by Reviewed by
-V = Visual - HG = Height Gauge -SR = Steel Ruller
- VC = Vernier Caliper - BP = Bevel Protactor
- UT = Ultrasonic Thickness
Date : Date :

You might also like