Physical specifications
Electrical specifications

Environmental specifications

Safety certifications

Link to product overview information

Link to product related documents

Physical specifications
Description
Specification
SFF Drives LFF Drives

4.29 x 43.46 x 70.7 cm (1.69 x


Dimensions (H x W x D) 4.29 x 43.46 x 74.98 cm (1.69 x 17.11 x 29.5 in)
17.11 x 27.83 in)

Minimum: 13.04 kg (28.74


Ib)
(1 Drive, 1 processor, 1
power supply, 2 heatsinks, 1 Minimum: 13.77 kg (30.36 Ib)
Smart Array controller, and 5 (1 Drive, 1 processor, 1 power supply, 2 heatsinks, 1 Smart Array
fans) controller and 5 fans)
Weight (Approximate)
Maximum: 16.27 kg (35.86 Maximum: 16.78 kg (37 Ib)
Ib)
(4 Drives, 2 processors, 2 power supplies, 2 heatsinks, 1 Smart
(10 Drives, 2 processors, 2 Array controller and 7 fans)
power supplies, 2 heatsinks,
1 Smart Array controller and
7 fans)

top

Electrical specifications
Specification Description

Rated line voltage


For 1600 W (Platinum): 200-240 V ac
For 800 W (Titanium) power supply: 200-240 V ac
Input requirement (Per power supply)
For 800 W (Platinum): 100-240 V ac
 
For 800 W (Universal) power supply: 200-277 V ac
For 800 W (-48 V dc): (-40) to (-72) V dc
500 W (Platinum) power supply: 100-240 V ac

about:blank 1/4
12/8/22, 9:02 HPE ProLiant DL360 Gen10 Server - Specifications

Specification Description

Maximum:
For 1600 W power supply:
5918 BTU/hr (At 200 V ac)
5888 BTU/hr (At 220 V ac)
5884 BTU/hr (At 240 V ac)
For 800 W (Titanium) power supply:
2905 BTU/hr (At 200 V ac)
2899 BTU/hr (At 220 V ac)
2893 BTU/hr (At 240 V ac)
For 800 W (Platinum) power supply:
3067 BTU/hr (At 100 V ac)
2958 BTU/hr (At 200 V ac)
2949 BTU/hr (At 240 V ac)
BTU rating For 800 W (Universal) power supply:
2964 BTU/hr (At 200 V ac)
2951 BTU/hr (At 230 V ac)

2936 BTU/hr (At 277 V ac)


For 800 W (-48) V dc power supply:
2983 BTU/hr (At (-40) V dc))
2951 BTU/hr (At (-48) V dc)
, 2912 BTU/hr (At (-72) V dc)
For 500 W (Platinum) power supply:
1902 BTU/hr (At 100 V ac)
1840 BTU/hr (At 200 V ac)
1832 BTU/hr (At 240 V ac)

Power supply output (Per power supply) Rated steady-state power:


For 1600 W power supply:
1600 W (At 240 V ac)
1600 W (At 240 V dc) for china only
For 800 W (Titanium) power supply:
800 W (At 200 V ac)
800 W (At 240 V ac)
800 W (At 240 V dc) for china only
For 800 W (Platinum) power supply:
800 W (At 100 V ac)
800 W (At 240 V ac)
800 W (At 240 V dc) input for china only
For 800 W (-48) V dc power supply:
800 W (At (-40) V dc)
800 W (At (-72) V dc)
For 800 W (Universal) power supply:
800 W (At 200 V ac)
800 W (At 277 V ac)
For 500 W (Platinum) power supply:
500 W (At 100 V ac)
500 W (At 240 V ac)
500 W (At 240 V dc) input for china only

about:blank 2/4
12/8/22, 9:02 HPE ProLiant DL360 Gen10 Server - Specifications

Specification Description

Maximum peak power:


For 1600 W power supply:
1600 W (At 200 to 240 V ac)
1600 W (At 240 V dc) input for china only
For 800 W (Titanium) power supply:
800 W (At 200 V ac)
800 W (At 240 V ac)
800 W (At 240 V dc) for china only
For 800 W (Platinum) power supply:
800 W (At 100 V ac)
800 W (At 240 V ac)
800 W (At 240 V dc) input for china only
For 800 W (Universal) power supply:

800 W (At 200 V ac)


800 W (At 277 V ac)
For 800 W (-48) V dc power supply:
800 W (At (-40) V dc)
800 W (At (-72) V dc)
For 500 W (Platinum) power supply:
500 W (At 100 V ac)
500 W (At 240 V ac)
500 W (At 240 V dc) input for china only

top

Environmental specifications
Specification Description

Standard operating support Extended ambient operating support

10° to 35°C (50° to 95°F) at sea level


with an altitude derating of 1.0°C per
every 305 m (1.8°F per every 1000 ft)
above sea level to a maximum of 3050 m
(10,000 ft), no direct sustained sunlight
Maximum rate of change is 20° C/hr (36°
F/hr) For approved hardware configurations,
The upper limit and rate of change may the supported system inlet range is
be limited by the type and number of extended to be: 40° to 45°C (104° to
options installed 113°F) at sea level with an altitude
System inlet temperature derating of 1.0°C per every 125 m (1.8°F
System performance during standard per every 410 ft) above 900 m (2953 ft)
operating support may be reduced if to a maximum of 3050 m (10,000 ft)
operating with a fan fault or above 30°C
(86°F) System performance may be reduced if
operating in the extended ambient
For approved hardware configurations, operating range or with a fan fault
the supported system inlet range is
extended to be: 5° to 10°C (41° to 50°F)
and 35° to 40°C (95° to 104°F) at sea
level with an altitude derating of 1.0°C
per every 175 m (1.8°F per every 574 ft)
above 900 m (2953 ft) to a maximum of
3050 m (10,000 ft).

Operating humidity Non-Operating humidity


Relative humidity
(Non-Condensing) 8% to 90% - Relative humidity, 28°C maximum 5% to 95% Relative humidity, 38.7°C (101.7°F)
wet bulb temperature maximum wet bulb temperature

Operating Non-Operating

3050 m (10,000 ft)


(This value may be limited by the type and 9144 m (30,000 ft)
Altitude
number of options installed) Maximum allowable altitude change rate is 457
Maximum allowable altitude change rate is 457 m/min (1500 ft/min)
m/min (1500 ft/min)

about:blank 3/4
12/8/22, 9:02 HPE ProLiant DL360 Gen10 Server - Specifications

Specification Description

Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C
ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).

Configuration SKU Entry Base Performance

Idle

Acoustic noise1 LWAd 5.1 B 5.1 B 5.2 B

LpAm 35 dBA 35 dBA 36 dBA

Operating

LWAd 5.3 B 5.2 B 5.9 B

LpAm 36 dBA 38 dBA 45 dBA

NOTE: 1. Acoustics levels presented here are generated by the test configuration only. Acoustics levels will vary depending on system configuration.
Values are subject to change without notification and are for reference only

top

Safety certifications
Specifications Description

To view the regulatory information for the product, view the Safety and
Compliance Information for Server, Storage, Power, Networking, and Rack
Emissions Classification (EMC) - Regulatory information Products, available at the Hewlett Packard Enterprise Support Center
Click here to view the Safety and Compliance Information for Server,
Storage,Power, Networking, and Rack Products (Multilingual) .

top

Link to product overview information


Click here to view the product overview document .
top

Link to product related documents


Click here to view the list of product related documents .
top

©Copyright 2022 Hewlett Packard Enterprise Development LP

Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein.
The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor
its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime
cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or
software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise
Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of
Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names
mentioned herein may be trademarks of their respective owners.

about:blank 4/4

You might also like