You are on page 1of 2
SABRATHA PLATFORM PROJECT No. 33320 Eaanny BECO mr F* Saipem | [PAAGIP GAS BV Libyan branch) “sspoxenanszc0 | C1 Eni Western Libya Gas Project [Subcontractorivendor Rev. os Contract N° 0140/NC/02 |Document No a x2781.810 cs Sheet Tore ‘SubcontractorVendor Originator Petreco Internati SABRATHA PLATFORM HYUNDAI PO NO. JESAB-M17 PETRECO REFERENCE X279 OILY WATER PUMPS 60-560-PC-101A/B MOTOR DATA SHEET OILY WATER SYSTEMS 540-560 60-560-VV-101 FLOATATION SEPARATOR STATUS LEGEND t= COT [Revieweo AND APPROVED Oram APERGAAe. |2=_L__I|APPROVED WHTH COMMENTS 3 FOR APPROVAL COMBE funtens Petreco) Oo Limited SIGNATURE o_[aati | Issued As Final an | w_|Wo es At] 7210808} INITIAL ISSUE au av} [Rew] Date Desenpton Frepored_| verted | Reproved | Peproved | Rapored Document Data ‘SubeonracerVendor [Convector] Company | ASYNCHRONOUS ELECTRIC MOTOR DATA SHEET PURCHASER INFORMATION MOTOR MANUFACTURER DATA Jo: eouiement ta6 nots Moxa, Meneat 29|wanurACTURER via Joo]ouawry wo. 30)MoTOR TPE INDUCTION Jos) surevy vowrace 009 3H 0H, si FRAME REF via osJoury RECOVERED OM. s2]RaTING ¢ow via los|aMoleNT TEMPERATURE CC) 441-135 s3]FULLLoao SPEED (RPM) via os|PoweR AasoRBED (W) via s4]FULL Loan cuRRENT (4) ves or|sPeeD (syncHRoNoUs) (RPN) via [Fut LoaD ToRQUE vrs os] DEGREE OF PROTECTION ss as|sranminc cuRRENT (HFLC) via. oo) TYPE OF ENCLOSURE [AIR COOLED (VTA) 7 |STaRTING TOROUE (uFLT) vita. }o|AREA CLASSIFICATION 7ONE2 183 selwa NA 11|HAZAROOUS AREA PROTECTION REQ ‘Bbxdle (VTA) 289 [EFFICIENCY sooseL | 78%eL | some, jz|imsuLATION CLASS z CLASS 40 |wa vra | vra | vera }12|STARTING METHOD . . Dor. 41 ]POWER FACTOR aooweL | 736FL | sOmFL, |wAXIMUM START-UP CURRENT (HFLC) vrA 42|Nia - vra_| va | vra 15)eRe/ E vrA 43 STATOR CONNECTION ra 6 z PUMP FLANGE (VTA) aa[wa . NA 17|ROTATION (FROMNDE) EE vt [NA NA 18] TERMINAL BOX (FROM NDE) ae | 46] Numeer oF POLES: vra, }i9[TERMINAL BOXENTRY ___ METRIC(VTA SIZE) ee ae NA faolcaBleGLANDSZE | BY CLIENT. JEARTH STUD SiZE (INTERNAL) vrA ar|svsTeMNEUTRAL | GROUNDED 48 | INSULATION CLASS ae: j22|ANTLCOND HEATER VOLTAGE _SEENOTES }s0/LUBRICATION a ra . J2s|TEMPERATURE RISE CLASS CLASS F Ey ae lala NA 52) BEARING TYPE (NDE) ie a a jas|PAINTFINISH ‘NOTE? ta a ianeete = fas|MOTOR ORE "DIRECT T0 PUMP SO _ eee jar|caBle SE /TYPE pycurnticor) | [s5|wA = Na zea ae a 6 |WA aa = sna tere L NOTES. If. MOTOR SHALL BE SUITABLE FOR ZONE 2 IIB T3 HAZARDOUS AREA. PAINT FINISH TO BE SUITABLE FOR OFFSHORE MARINE ENVIRONMENT TO CLIENT SPEC, Js. MOTORS 7.5kW AND ABOVE TO BE FITTED WITH AN ANTL-CONDESATION HEATER 230Vac S0Hz 1 PHASE. VTA SIZE IF APPLICABLE ‘TERMINAL BOX TO BE ON RIGHT HAND SIDE LOOKING FROM COUPLING SIDE. I5. RH 40% Min 95% Max BAROMETRIC PRESSURE MIN 990 mBar 1037 mBar MAX ATMOSPHERE WILL BE SALT LADEN WITH 0.01pm H2S CONTINUOUSLY WITH Sppm H2S AND 2ppm S02 FOR OCCASIONAL ‘SHORT PERIODS. BID x279-K.003 (CLIENT STANDARDS TO BE READ IN CONJUNCTION WITH THIS DATA SHEET 20167.EQP.ELE-FUN Rev0 ASYNCHRONOUS MOTORS. 03-S-£-0003-00 Rev C1 ELECT SYS FOR PACKAGE PLANT P03-S-P-0004-00 Rev C1 APPENDIX PAINTING SPEC PROJECT X279 Peireco) BocuMeNENS cr ats ISHEET 2 OF 2 ferwational Limited 6 \Projects'X279\Dsta\CIE\BSPO3KNO032.00_Ai Floatation Pump Motor Data Sheet xis.

You might also like