2

The most recent evolution of the family of Keratron topographers,


represents a standard of excellence in corneal topography.
The only portable topographer, able to capture and process images, process maps on
board and which has an internal patient database exportable via LAN or USB.
Main functions:
Wide Range Corneal Topography and Fast Acquisition
Corneal Aberrometry
Pupillometry
Non-invasive Break-up Time
is equipped with an easy and intuitive software and a colour touch
screen display which allows quick access to the image processing system, ensuring
highly repeatable and reliable results even in the most complex cases.
The simplicity of the capturing system and the “mires cone”, with dual functionality Near/
Far, offer the advantages of a superior corneal coverage and an easier/faster capturing,
ensuring a better efficiency and a lower number of repeated attempts.
The accuracy of the data helps to optimise testing of contact lenses, helping the specialist
in difficult and particular conditions. The large colour screen gives instant visualization
of the topographic maps, pupillometry in visible light and infrared, Sim-K and E-values.
The transfer of data is fast and direct to external PC for archiving and processing.
3

ON-BOARD DATABASE
5.7” TOUCH SCREEN AND MAP PROCESSING

ENHANCED LIVE IMAGE


BIVALENT CONE FOR WIDE
CORNEAL COVERAGE
AND FAST ACQUISITION

FAST BURST
ACQUISITION MODE

USB/LAN
CONNECTIVITY
4

Technical Specifications

PARAMETER SPECIFICATION
Model Keratron™ Nova
Ref. 161601
VIDEOKERATOSCOPE
Configuration Mountable on the most popular slit lamps
Area of Analysis 10mm x 14mm (visible on the monitor)
Keratoscope Cone 28 border mires equally spaced on a 43D sphere.
Bivalent cone with Near/Far selection by touch screen
Analysed Points Over 80,000
Measured Points 7,168
Corneal Coverage From 0.33 mm (minimum diameter on a 43D sphere) up to
11mm on a normal eye
Measured Area 90% of the corneal surface (normal eyes) with near cone
selection. 75% of the corneal surface (normal eyes) with far
cone seletion
Dioptric Power Range From 1D to over 120D
Resolution ±0,01D - 1 micron
Focusing Device Eye Positioning Control System (EPCS patented) and
automatic acquisition with decentration correction
Videocamera Monocromatic - high sensitivity (CCD)
Monitor 5.7’’ TFT display with touch screen
Other Features Processing on videokeratoscope of rings, axial, curvatures,
spherical offset and Gaussian maps, TBUT, Sim-K, E-values,
pupil data. Internal patients database
Accessories Included Calibration sphere, touch pen, USB memory stick, Scout
software, footswitch, power supply, Ethernet cross-over cable
Capturing Images Capturing by footswitch or button. Capturing in semi-
automatic mode (“burst”)
Communication External PC and VK Via Ethernet cable (cross) provided for connecting “peer
to peer” with the external PC (not supplied), or via a LAN
network. Exams export to USB stick
Power Supply 100-240VAC, 50/60Hz, with medical power supply
provided
COMPUTER (Recommended Minimal Requirements)
Operating System MS Windows 7/8/10 (32 e 64 bit)
Processor/Memory Intel i3, 2GB RAM
Disks Internal 180 GB HD, CD-ROM
Monitor Super VGA color monitor 14”,1024x768 points 16 millions
color
Printer Color printer
Ports Ethernet, USB 2.0 high speed
5

SOFTWARE
Dioptric Scale Absolute, normalised, adjustable
Keratometric Values and Indices K-readings, meridians, hemi-meridians, Maloney indices,
eccentricity, CLMI keratoconus indices, keratoconus follow-up
Pupil Definition of the edge, diameter and decentering (angle K)
Zone and Grids Indication of the diameters 3, 5 and 7 mm, Cartesian axes,
and millimeter grid
Maps Local curvature, axial curvature, wavefront OPD or wavefront
error (WFE) refraction and height map with 3D insert
Axis Moving Position of the axis selectable as corneal vertex, pupil center
on any other choice
Print Print screen with header of the institution or personalized print
templates
Special Functions Profiles, difference, repeatability check, maps comparison
caliber, refraction calculator
Image Acquisition and Videos Enabled with TV camera mounted on slit lamp and any video
capture board (not included)
On-line Help Detailed on line multi language help detailed for all functions
Contact Lenses Fluorescein pattern simulation of most international contact
lenses manufacturer geometries. Tilting to simulate lid
pressure. Lens displacement in any position. Eccentricity
measure at 6 and 8 mm, over refraction calculator.
Personalised auto-fit for customised lenses. Ortho-K custom
fitting. Adjustable clearance scale. Link to third party
software.
Internet Connection Maps can be sent as attachments to e-mails
Local Network and Database Management of one or more independent databases
shareable in a network
OPTIONALS
Kit for Contact Lenses Analysis (Ref. 162216)
Base with joystick and left/right sensor (Ref. 163204)
CONFORMITY
CE MARK Directive 93/42/CEE

L x W x H:
270 x 155 x 285 mm
6

Keratron™ has represented for more than 20 years the standard of excellence in
Corneal Topography for its precision characteristic, elevated repeatability and capacity
to highlight the smallest details.
Main functions:
Wide Range Corneal Topography and Fast Acquisition
Corneal Aberrometry
Pupillometry
Non-invasive Break-up Time
New Keratron™, with colour touch screen display, adds the possibility to process the
main maps on the same device.
Its bivalent cone responds to the need for an ample corneal range and faster topographic
exam.
The ample corneal range is extremely important for the examination of the transition
areas.
In refractory surgery, for a correct simulation of the contact lenses and for the diagnosis
of peripheral alterations.
The measuring cone, combined with the other property algorithms, measures the
curvature and altimetries of each point in the cornea with a precision to the micron or
less, improving the process of implementation of the refractive surgery treatment and
LAC custom.
The exclusive EPCS (Eye Position Control System) guarantees the acquisition of correct
measurements, automatically adjusting eventual off-centres and enabling an effective
repeatability.
The large colour screen gives instant visualization of the topographic maps, pupillometry
in visible light and infrared, Sim-K and E-values.
The transfer of data is fast and direct to external PC for archiving and processing.
7

BIVALENT CONE FOR WIDE


CORNEAL COVERAGE
AND FAST ACQUISITION

LARGE 7”TOUCH SCREEN

PROCESSING OF MAPS IN REAL TIME


8

Technical Specifications

PARAMETER SPECIFICATION
Model KeratronTM
Ref. 161501
VIDEOKERATOSCOPE
Area of Analysis 10mm x 14mm (visible on the monitor)
Keratoscope Cone 28 border mires, equally spaced on a 43D sphere
Bivalent cone, with touch screen “Near/Far” selection
Analyzed Points Over 80,000
Measured Points 7,168
Corneal Coverage From 0.33mm (minimum diameter) on a 43D sphere up
to 11mm on a normal eye
Measured Area 90% of the corneal surface (normal eyes) with “Near” cone selection
75% of the corneal surface (normal eyes) with “Far” cone selection
Dioptric Power Range From 1D to over 120D
Resolution +/- 0.01D - 1 micron
Focusing Device Eye Positioning Control System (EPCS patented) and automatic
acquisition, with decentration correction
Camera High resolution (C.C.I.R.)
Monitor 7’’ color monitor with touch screen, width 800x480
OD/OS automatic recognition
Videokeratoscope processing:
rings, axial maps and curves, pupillary data
Accessories Included Table top with head rest, calibration kit, USB memory stick, Scout
software
Power Supply Mains (100-240 Vac, 50/60Hz)
Image Acquisition Acquisition through joystick and EPCS, digital conversion, processing
and transferring from the touch screen
Communication External PC and VK Via Ethernet cable (cross) provided for connecting “peer to peer” with
the external PC (not supplied), or via a LAN network
COMPUTER (Recommended Minimal Requirements)
Operating System Windows 7/8/10 (32 e 64 bit) and Windows updates
Processor/Memory Intel I3, 2 Gb RAM
Disks Internal 180 GB HD, CD-ROM
Monitor Super VGA color monitor 14”,1024x768 points, 16 millions color
Printer Color printer
Ports Ethernet
9

SOFTWARE
Dioptric Scale Absolute, normalised, adjustable
Keratometric Values and Indices K-readings, meridians, hemi-meridians, Maloney indices, eccentricity,
CLMI keratoconus indices, keratoconus follow-up
Pupil Definition of the edge, diameter and decentering (angle K),
infrared pupillometry
Zone and Grids Indication of the diameters 3, 5 and 7mm,
Cartesian axes and millimeter grid
Maps Local curvature, axial curvature, wavefront OPD or wavefront error
(WFE) and refraction, height map with 3D insert
Axis Moving Position of the axis selectable as corneal vertex, pupil center on any
other choice
Print Print screen with header of the institution or personalized print templates
Special Functions Profiles, difference, repeatability check, maps comparison, caliber,
refraction calculator, follow-up, TBUT
Image Acquisition and Videos Enabled with TV camera mounted on slit lamp and any video capture
board (not included)
On-line Help Detailed on-line multi language help for all functions
Contact Lenses Fluorescein pattern simulation of most international contact
lenses manufacturer geometries. Tilting to simulate lid
pressure. Lens displacement in any position. Eccentricity
measure at 6 and 8 mm, over refraction calculator.
Personalised auto-fit for customised lenses. Ortho-K custom
fitting. Adjustable clearance scale. Link to third party software.
Internet Connection Maps can be sent as attachments to e-mails
Local Network and Database Management of one or more independent database shareable in a
network
OPTIONALS
Power Lifting Base Stative for the supplied top (Ref. 163102)
Kit for Contact Lenses Analysis Permits obtaining the topographic map of the inner and outer
surfaces of gas permeable contact lenses with continuous surface.
By manually positioning up to three rings on the maps in the areas
to be measured, the mean radius, apical radius and eccentricity are
measured (Ref. 162216)
REGULATORY
CE Mark Directive 93/42/CEE

WEIGHT:
11 Kg approx.

L x W x H:
460 x 210 x 440 mm
10

Keratron™ Scout, in its three configurations - portable, fixed, intraoperative – is a


compact, transportable and practical device. It adds flexibility of use to the precision,
high repeatability and the capacity to highlight the slightest details, characteristics that
have made Keratron™ the topographer of reference in the sector.
The exclusive design of the “mires cone” with EPCS (Eye Position Control System) makes
Keratron™ Scout fully adaptable to the most complex cases, ensuring the best efficiency
and a lower number of repeated attempts.
Main functions:
Wide Range Corneal Topography
Corneal Aberrometry
Pupillometry
Non-invasive Break-up Time
Keratron™ Scout, with integrated display, offers full control during the process of image
acquisition and enables a rapid transfer of these to the PC.
11

EPCS ALIGNMENT SYSTEM


WITH RECLINABLE AND
REAL TIME IMAGE DISPLAY INTERCHANGEABLE MIRES CONE

INFRARED PUPILLOMETRY
12

Technical Specifications

PARAMETER SPECIFICATION
Model KeratronTM Scout
Ref. 161204
CONFIGURATIONS
Portable Battery or cable operated
Fixed Easily mounted on any slit lamp
Intraoperative Balanced arm surgical trolley and disposable sterile plastic covers
VIDEOKERATOSCOPE
Area of Analysis 10mm x 14mm (visible on the monitor)
Keratoscope Cone 28 border mires, equally spaced on a 43D sphere
Analyzed Points Over 80,000
Measured Points 7,168
Corneal Coverage From 0.33mm (minimum diameter on a 43D sphere) up to 11mm on a
normal eye
Dioptric Power Range From 1D to over 120D
Resolution +/- 0.01D - 1 micron
Focusing Device Eye Positioning Control System (EPCS patented) and automatic
acquisition, with decentration correction
Other Features “OK” button and OD/OS acquisition keys, reverse OR keys, low-power
standby function, tiltable mires cone (0°-10°)
Camera High resolution (C.C.I.R.)
Monitor 4” B&W
Accessories Included Calibration set, Scout software
COMPUTER (Recommended Minimal Requirements)
Operating System Windows 7/8/10 (32 e 64 bit) and Windows updates
Processor/Memory Intel i3, 2GB RAM
Disks Internal 180 GB HD, CD-ROM
Monitor Super VGA color monitor 14”,1024x768 points, 16 millions color
Printer Color printer
Ports Ethernet
SOFTWARE
Dioptric Scale Absolute, normalised, adjustable
Keratometric Values and Indices K-readings, meridians, hemi-meridians, Maloney indices, eccentricity,
CLMI keratoconus indices, keratoconus follow-up
Pupil Definition of the edge, diameter and decentering (angle K),
infrared pupillometry
Zone and Grids Indication of the diameters 3, 5 and 7 mm,
Cartesian axes and millimeter grid
Maps Local curvature, axial curvature, wavefront OPD or wavefront error
(WFE) and refraction, height map with 3D insert
Axis Moving Position of the axis selectable as corneal vertex, pupil center on any
other choice
Print Print screen with header of the institution or personalized print templates
Special Functions Profiles, difference, repeatability check, maps comparison, caliber,
refraction calculator, follow-up, TBUT
13

Image Acquisition and Videos Enabled with TV camera mounted on slit lamp and any video capture
board (not included)
On-line Help Detailed on-line multi language help for all functions
Contact Lenses Fluorescein pattern simulation of most international contact lenses
manufacturer geometries. Tilting to simulate lid pressure. Lens
displacement in any position. Eccentricity measure at 6 and 8 mm, over
refraction calculator. Personalised auto-fit for customised lenses. Ortho-K
custom fitting. Adjustable clearance scale. Link to third party software.
Internet Connection Maps can be sent as attachments to e-mails
Local Network and Database Management of one or more independent database shareable in a
network
OPTIONALS
Support Base Support for Keratron™ Scout with LAF kit and recharging station for the
battery version. This powers the videokeratoscope and interfaces it with
the PC by means of USB port (Ref. 162202)
L.A.F. Kit Slide for fitting in LAF standard accessories hole D=8mm with expander
pin, cable for connecting to the support base and pedal (Ref. 162206)
Battery Module Can be connected to the videokeratoscope for acquisition in portable
mode. 2100 mAh batteries (about 1 hour of continuous use)
(Ref. 162205)
Headrest Device To be fitted above the videokeratoscope for manual acquisition with LAF
kit cable (Ref. 162206) or battery (Ref. 162205)
Far Mires Cone For deep set eyes, 28 border mires, 3mm more than standard cone,
corneal coverage 75-80% (Ref. 162211)
OR Sterile Covers Covers standard border mires cone (Ref. 196201) or far cone
(Ref. 196203), sterile and disposable
Movable Base with Joystick with table and chin-rest (Ref. 163202)
Instrument Case For the unit and accessories: with shaped sponge and wheels
(Ref. 169201)
Kit for Contact Lenses Analysis Permits obtaining the topographic map of the inner and outer
surfaces of gas permeable contact lenses with continuous surface.
By manually positioning up to three rings on the maps in the areas
to be measured, the mean radius, apical radius and eccentricity are
measured (Ref. 162216)
Power Lifting Base Stative for base with joystick (Ref.163102)
REGULATORY
CE Mark Direttiva 93/42/CEE

WEIGHT:
1 Kg

L x W x H:
280 x 100 x 240 mm
14

Keratron™ Piccolo combines excellent performance with transportability and easy handling.
Thanks to its limited size it guarantees maximum compatibility with any slit lamp, ensuring
the same precision, performance, repeatability and corneal range of the other instruments
of the Keratron™ family.
The exclusive design of the “mires cone” with EPCS (Eye Position Control System) makes
Keratron™ Piccolo fully adaptable to the most complex cases, ensuring the best efficiency
and a lower number of repeated attempts.
Main fuctions:
Wide Range Corneal Topography
Corneal Aberrometry
Non-invasive Break-up Time
Real Time Control of Eye Position on the PC Screen
15

EPCS ALIGNMENT SYSTEM


WITH RECLINABLE AND
INTERCHANGEABLE MIRES CONE

QUICK PLUGIN
FOR THE SLIT LAMP

SUPPORT BASE WITH


INTEGRATED CHARGER
16

Technical Specifications

PARAMETER SPECIFICATION
Model KeratronTM Piccolo
Ref. 161301
CONFIGURATIONS
Portable Easily mounted on any slit lamp
VIDEOKERATOSCOPE
Area of Analysis 10mm x 14mm (visible on the monitor)
Keratoscope Cone 28 border mires, equally spaced on a 43D sphere
Analyzed Points Over 80,000
Measured Points 7,168
Corneal Coverage From 0.33mm (minimum diameter) on a 43D sphere up to 11mm on
a normal eye
Measured Area 90% of the corneal surface (normal eyes)
Dioptric Power Range From 1D to over 120D
Resolution +/- 0.01D - 1 micron
Focusing Device Eye Positioning Control System (EPCS patented) and automatic
acquisition, with decentration correction
Camera High resolution (C.C.I.R.)
Other Features Tiltable mires cone (0°-10°)
Accessories Included Calibration kit, Scout software
COMPUTER (Recommended Minimal Requirements)
Operating System Windows 7/8/10 (32 e 64 bit) and Windows updates
Processor/Memory Intel i3, 2GB RAM
Disks Internal 180 GB HD, CD-ROM
Monitor Super VGA color monitor 14”,1024x768 points, 16 millions color
Printer Color printer
Ports Ethernet
SOFTWARE
Dioptric Scale Absolute, normalised, adjustable
Keratometric Values and Indices K-readings, meridians, hemi-meridians, Maloney indices, eccentricity,
CLMI keratoconus indices, keratoconus follow-up
Pupil Definition of the edge, diameter and decentering (angle K)
Zone and Grids Indication of the diameters 3, 5 and 7mm, Cartesian axes and
millimeter grid
Maps Local curvature, axial curvature, wavefront OPD or wavefront error
(WFE) and refraction, height map with 3D insert
Axis Moving Position of the axis selectable as corneal vertex, pupil center on any
other choice
Print Print screen with header of the institution or personalized print
templates
Special Functions Profiles, difference, repeatability check, maps comparison, caliber,
refraction calculator, follow-up, TBUT
Image Acquisition and Videos Enabled with TV camera mounted on slit lamp and any video capture
board (not included)
17

On-line Help Detailed on-line multi language help for all functions
Contact Lenses Fluorescein pattern simulation of most international contact lenses
manufacturer geometries. Tilting to simulate lid pressure.
Lens displacement in any position. Eccentricity measure at 6 and 8
mm, over refraction calculator. Personalised auto-fit for customised
lenses. Ortho-K custom fitting. Adjustable clearance scale.
Link to third party software.
Internet Connection Maps can be sent as attachments to e-mails
Local Network and Database Management of one or more independent database shareable in a
network
OPTIONALS
Kit for Contact Lenses Analysis Permits obtaining the topographic map of the inner and outer
surfaces of gas permeable contact lenses with continuous surface.
By manually positioning up to three rings on the maps in the areas
to be measured, the mean radius, apical radius and eccentricity are
measured (Ref. 162216)
Power Lifting Base Stative for base with joystick (Ref. 163102)
Far Mires Cone For deep set eyes, 28 border mires, 3mm more than standard cone,
corneal coverage 75-80% (Ref. 162211)
Movable Base with Joystick with table and chin-rest (Ref. 163202)
REGULATORY
CE Mark Directive 93/42/CEE

PESO:
1 Kg

L x P x H:
110 x 160 x 250 mm
18

KERATOKONUS LOCAL AND AXIAL MAPS ALTIMETRIC MAPS (SPHERICAL OFF-SET)


The map of the local curvatures, contrary to that of the axial maps, highlight ELEVATIONS, 3D
even the smallest details, enabling a certain diagnosis in the presence of The altimetries of all the corneal points are representable with respect to a
peripheral phenomena or ones of very small entity. sphere of reference that can be positioned at will.
The altrimetric differential maps (for example, Post-Pre Op) are obtained by
aligning the three reference points and cancelling the relative “Tilting”.

BEST FIT (MALONEY) AND CLMI INDICES FOLLOW-UP


Designed and validated statistically by Doctor Roberts and her colleagues of The evolution in time of the topography of the eye can be represented on any
OSU (Ohio State University) support the clinical diagnosis and follow-up of the kind of map, together with the chart of a chosen parameter among the CLMI,
keratoconus, indicating the KPP (Keratoconus Percentage Probability), as well Sim-K, Best Fit indices or quantity of RMS of the main corneal aberrations.
as the position and average power of the apex on the map.

Corneal Topography Maps


19

VISUS PUPILLOMETRY
CORNEAL ABERROMETRY The double lights of the Placido rings, visible and infrared, measuring the
The examination of the corneal aberrations has opened a new chapter in the pupil’s dimensions and centre in the different lighting conditions.
“Topographic Link” with various excimer lasers.
The cornea is examined in order to measure the contribution to the wave front
or rather the corneal aberrometry.

GAUSSIAN MAP REFRACTIVE FUNCTIONS


The Gaussian curvature is an independent map from the axis and from the fix MAX STREHL RATIO CALCULATION
point. It enables to highlight ectasias and other inelastic corneal deformities. The “Max Strehl” function searches a spherical-cylindrical-axis adjustment that
Concealing the permanent astigmatisms it enables, for example, to objectively optimises the visus of eyes with complex aberrations. Ideal if calculated on the
localise the apex of a peripheral keratoconus or a pellucida. front of the ocular wave front measured with Keratron™ Onda. It can in any
case provide a useful evaluation also of the corneal wave front (if the internal
component is less critical).
20

Contact Lenses
The kit for analysing contact lenses enables to measure the curvature but also the geometry
of the lens and the a-spherical measurements of each area.
Therefore it is possible to verify if the characteristics of the lens have changed over time
or, if the origin of the lens is unknown, find its original shape and characteristics.
The device consists in a support on which the lens is placed with the help of a drop of
water. Two different racks enable to measure the two faces of the lens.
The photograph of the lens with the Placido rings reflected from the topographer gives
an idea of the quality level on the regularity of the surfaces and the presence of deposits.
The map gives curvature measurements of each surface point and detects the geometry
of the lens.
The system is very accurate and repeatable and finally allows to document the status and
the parameters of the lenses in an unmistakeable and evidentiary manner; in fact being
in possession of archive document that can be used in case of claims by the user or the
user’s ophthalmologist has become today increasingly recommended. It should be noted,
however, that since the method is based on the reflection of Placido rings, the system only
works if the surface is continuous.
This device enables the Keratron™, Keratron™ Nova, Keratron™ Scout and Keratron™
Piccolo corneal topographers an important added function that enables the use of the
topographer in contactology in a complete manner.
21

A sophisticated software enables the perfectly realistic simulation of the fluorescenic


patterns of any RGP contact lens according to the following:
Choice of lens of production
Use of personal automatic protocol
Automatic choice recommended by the producer
Custom lenses (CALCO, Wave etc.)
The geometries of the main RGP contact lenses producers are available.
The user can easily create new trial sets.
Some laboratories have provided protocols for automatic selection of the best lens which,
when put in practice, have recognised to be the best choice in 90% of cases.
Personalised autofit methods enable to standardise one’s own application choice with
lenses that have an optimal fit on the cornea at all times.
In this way custom-made lenses of any geometry may be made, including inverse
geometry lenses for orthokeratology or cases of post refractive surgery.
The possibility to connect the topographic data to a computer for the production of
personalised geometry special lenses enables the production of the “Custom Cornea”
lenses.
22

LENS ADJUSTMENT

CHOICE OF TRIAL SET AUTOMATIC PROTOCOLS


23

AUTOFIT PROGRAM: PROJECT FOR A LENS FOR ORTHO-K

PROJECT FOR A A-SPHERICAL “CONTOUR” LENS


24

162202 Docking base for Keratron™ Scout 162208 Head rest for Keratron™ Scout

162205 Rechargeable battery for Keratron™ Scout 162211 Far mire cone for Keratron™ Scout/
Keratron™ Piccolo

162206 Slit lamp adaptor kit for Keratron™ Scout 162212 Slit lamp adaptor eccentric spacer for
Keratron™ Scout

Accessories
25

162216 Analysing contact lenses kit 169201 Suitcase for Keratron™ Scout 163204 Base with joystick for Keratron™ Nova

163102 Electric stand for Keratron™/Keratron™ 196201 Sterile cover for Keratron™ Scout standard
Scout/Keratron™ Piccolo cone (6pcs)

163202 Base with joystick for Keratron™ Scout / 196203 Sterile cover for Keratron™ Scout far cone
Keratron™ Piccolo (6pcs)
26
27

family
AMERICA AFRICA EUROPE MIDDLE EAST ASIA

DANDELIO www.dandelio.com
Argentina Algeria Austria United Kingdom Saudi Arabia Bangladesh
Bolivia Egypt Belgium Czech Republic Bahrain China
Brazil Morocco Denmark Russia Jordan South Korea
Canada South Africa France Serbia Iran Philippines

DANDELIO
Chile Sudan Germany Slovakia Iraq Japan
Colombia Tunisia Greece Spain Israel Hong Kong
Costa Rica Italy Switzerland Lebanon India

Cover photo by Jason e Anna Ball


Cuba Netherlands Turkey Pakistan Indonesia
Ecuador Poland Ukraine Syria Nepal
Mexico Portugal Hungary Yemen Thailand
Paraguay Taiwan
USA Vietnam
Venezuela

161501/07/17/English
Distribuited by:

CUSTOMER SERVICE
OPTIKON 2000 S.p.A. Rome office - Italy
Via del Casale di Settebagni, 13 Via del Casale di Settebagni, 13 - 00138 Roma
00138 Roma - Italia ph. +39 06 8888355 - fax +39 06 8888440
www.optikon.com e-mail: sales@optikon.it

You might also like