You are on page 1of 62

For Official Use Only

भारत सरकार GOVERNMENT OF INDIA


रे ल मंत्रालय MINISTRY OF RAILWAYS

Question Bank on
LHB Coaches
END USER: Coaching Maintenance Staff

CAMTECH/E/EP-03/2020-21/QB-LHB/1.0
March 2021

Maharajpura, Gwalior – 474 005


ii

Question Bank on
LHB Coaches
iii

QUALITY POLICY

“We at RDSO, Lucknow are committed to maintain


and update transparent standards of services to
develop safe, modern and cost effective railway
technology complying with statutory and regulatory
requirements, through excellence in research,
designs and standards by setting quality objectives,
commitment to satisfy applicable requirements and
continual improvements of the quality management
system to cater to growing needs, demand and
expectations of passenger and freight traffic on the
railways through periodic review of quality
management systems to achieve continual
improvement and customer appreciation. It is
communicated and applied within the organization
and making it available to all the relevant interested
parties.”
iv

FOREWARD

Indian Railways started inception & mass production of LHB coaches


from the year 2002. Now the number of LHB coaches is increasing
day by day. These coaches have been manufactured with advanced
technology as compared to ICF coaches to provide better comfort,
safety and modern facilities. The design of LHB coaches is different
from the ICF coaches and so as its maintenance practice.
Dissemination of knowledge regard to LHB coaches & Proper
training of Coach Maintenance staff & supervisors is very important.

CAMTECH has prepared this question bank to meet the training


requirement of staff and supervisors. Providing knowledge of LHB
coaches is the main objective of this handbook. This handbook
"Question Bank (Electricals) on LHB Coaches" contains objective-
type questions related to a brief introduction, technical details,
RMPU, WRA, power car related components & maintenance
schedule of LHB coaches.

I am sure that the handbook will be useful for training of maintenance


related staff and supervisors to ensure trouble-free train operation
service.

CAMTECH Gwalior Jitendra Singh


Date: 22.03.2021 Principal Executive Director
v

PREFACE

The maintenance of LHB-type coaches is quite different from that of


ICF design coaches. Therefore, it has become necessary to provide
different training materials for maintenance staff and supervisors. The
artisans and supervisors involved in maintenance & safety operations
are considered up-to-date respecting the technical knowledge of this
coaching stock.

CAMTECH has prepared a hand booklet on "Question Bank


(Electricals) on LHB Coaches" with a view to assisting the employees
through training in which more than 250 questions related to a brief
introduction, technical and features of various components, and
maintenance activities of LHB coaches have been compiled.

The purpose of this handbook is to assist the employees concerned


and does not supersede any existing instructions from Railway Board,
RDSO or IRCA etc. Most of the data and information mentioned
herein are available in LHB manual and in various books or other
printed matters. If any changes are made, these will be issued in the
form of correction slips.

Technological upgrading and learning is a continuous process. Hence


feel free to write us for any additions/modifications or in case you
have any suggestions to improve the handbook. Your contribution in
this direction will be highly appreciated.

CAMTECH, Gwalior Himanshu Maheshwari


Date: 22.03.2021 Dy. Director (Electrical)
vi

CONTENTS

FOREWARD .................................................................................................. iv
PREFACE........................................................................................................ v
CONTENTS ................................................................................................... vi
ISSUE OF CORRECTION SLIP ........................................................................ vii
DISCLAIMER ................................................................................................viii
OUR OBJECTIVE ..........................................................................................viii
1 GENERAL QUESTIONS ......................................................................... 1
2 MAINTENANCE SCHEDULE ................................................................. 2
3 TECHNICALLY QUESTIONS .................................................................. 4
4 WRA .................................................................................................... 6
5 TECHNICAL DATA RMPU..................................................................... 9
6 REGULATED CUM EMERGENCY BATTERY CHARGER ........................ 15
7 REGULATED BATTERY CHARGER OF REBC........................................ 16
8 EMERGENCY BATTERY CHARGER (OF REBC) .................................... 18
9 PROTECTIONS FOR REGULATED BATTERY CHARGER ....................... 19
10 PROTECTIONS FOR EMERGENCY BATTERY CHARGER ...................... 20
11 LIGHT FITTINGS................................................................................. 21
12 BATTERY ........................................................................................... 23
13 EOG POWER CAR .............................................................................. 27
14 RELAY FOR PROTECTION OF GENERATOR CAR ................................ 32
15 PANTRY CAR AND MINI PANTRY EQUIPMENT ................................. 35
16 LHB NON AC COACH ....................................................................... 39
17 FILL IN THE BLANKS......................................................................... 47
ANSWERS .................................................................................................... 48
vii

ISSUE OF CORRECTION SLIP

The correction slips to be issued in future for this handbook


will be numbered as follows:

CAMTECH/ E/Ep-03/2020-21/QB-LHB/1.0/C.S. # XX date---

Where “XX” is the serial number of the concerned


correction slip (starting from 01 onwards).

CORRECTION SLIPS ISSUED

Sr. No. Date of Issue Page no. & Item no. Remarks
modified
viii

DISCLAIMER
It is clarified that the information given in this booklet does not
supersede any existing provisions laid down by the Railway Board,
RDSO and OEM’s Manual. This document is not statuary and
instructions given are for the purpose of guidance only. If at any
point contradiction is observed, then Railway Board/RDSO guidelines
and OEM’s Maintenance and Operating Manuals may be referred.

OUR OBJECTIVE
To upgrade maintenance technologies and methodologies and
achieve improvement in productivity and performance of all
Railway assets and manpower which inter-alia would cover
reliability, availability, utilization and efficiency.

If you have any suggestion & any specific comment, please write to
us:
Contact person: Dy. Director (Electrical)
Postal Address: Centre for Advanced Maintenance
Technology, Opposite Hotel Adityaz,
Near DD Nagar, Maharajpur, Gwalior
(M.P.) Pin Code – 474 005

Phone : 0751 - 2470740


Fax : 0751 – 2470841
E-mail : direlcamtech@gmail.com
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 1

1 GENERAL QUESTIONS
1. What is the full form of LHB?
a. Lower heavy Bogie b. Linke Hofmann-Busch
c. low height Bogie d. None of these

2. What is the riding index of LHB coach?


a. 2.0 b. 2.5
c. 2.75 d. 3.0

3. What is the length of LHB coaches’ body?


a. 23570 mm b. 23545 mm
c. 23540 mm d. 23565 mm

4. What is the maximum width of LHB coaches’ body?


a. 3260 mm b. 3240 mm
c. 3456 mm d. 2356 mm

5. What is the higher speed potential of LHB coaches?


a. 160 up to 180 Kmph b. 180 up to 200 Kmph
c. 160 up to 200 Kmph d. 200 up to 220 Kmph

6. What is the Length of the LHB Power car body?


a. 24000 mm b. 23540 mm
c. 2400 mm d. 24430 mm

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 2

2 MAINTENANCE SCHEDULE
7. D1 maintenance of LHB coaches done after how long time?
a. 7±1 day b. 15 days
c. Every Trip d. 30 days

8. D2 maintenance of LHB coaches done after how long time?


a. 30 days ± 1days b. 30 days ± 3days
c. 30 days ± 5days d. 30 days ± 7 days

9. D3 maintenance of LHB coaches done after how long time?


a. 90 days ± 7days b. 120 days ± 3days
c. 150 days ± 1days d. 180 days ± 15 days

10. ‘SS-I’ maintenance of LHB coaches done after how long


time?
a. 1 year b. 1.5 year
c. 2 years d. 3 years

11. ‘SS-II’ maintenance of LHB coaches done after how long


time?
a. 1 year b. 1.5 year
c. 2 years d. 3 years

12. ‘SS -III’ maintenance of LHB coaches done after how long
time?
a. 5 years b. 4 years
c. 3 years d. 6 years

13. On KM basis ‘SS- I’ of LHB coach is done -


a. 5 lakhs b. 6 lakhs
c. 9 lakhs d. 12 lakhs

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 3

14. On KM basis ‘SS -II’ of LHB coach is done -


a. 5 lakhs b. 6 lakhs
c. 12 lakhs d. 24 lakhs

15. ‘POH’ maintenance of LHB coaches done after how long


time?
a. 5 lakhs b. 6 lakhs
c. 12 lakhs d. 24 lakhs

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 4

3 TECHNICALLY QUESTIONS
16. The Fire Extinguisher used in AC LHB coaches is –
a. Foam type b. DCP Type
c. CO2 type d. None of these

17. Fire Extinguisher should be refilled -


a. Every month b. Every 3 months
c. After 1 year d. On every trip

18. What is the full form of EOG?


a. End on generation b. Mid on generation
c. Hotel load on generation d. Head on generation

19. What is the full form of HOG?


a. End on generation b. Mid on generation
c. Hotel load on generation d. Head on generation

20. What is the hotel load?


a. Light and Fan load b. Air conditioning load
c. Pantry equipment load d. All of above

21. How many volts are supplied to LHB coaches?


a. 230 volts b. 415 volt 3 phase
c. 750 volt 3 phase d. 1500 volt 3 phase

22. How many feeders are supplied Power to LHB coaches?


a. 1 b. 2
c. 3 d. 4

23. What is the Coil Voltage of the Main feeder contactor in the
LHB AC coach?

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 5

a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC

24. What is the rating of Z-S Coupling?


a. 200 Amp. b. 300 Amp.
c. 400/500 Amp. d. None

25. What is the capacity of the step-down transformer


provided in the coaches?
a. 100 kVA b. 75 kVA
c. 60 kVA d. 50 kVA

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 6

4 WRA
26. What is the full form of WRA?
a. Wire relay appliances b. Water raising apparatus
c. Worker relief d. None of these
arrangement

27. How many water tanks provided under the frame of AC


coach?
a. 4 b. 3
c. 2 d. None

28. What is the Capacity of the Water Tank provided under the
frame of the coach?
a. 500 liter b. 550 liter
c. 600 liter d. 685 liter

29. Where mounted the WRA in the Coach?


a. Bogie b. Under frame
c. A & B d. None

30. Which type of Motor is used in mono-block centrifugal


type WRA?
a. DC b. AC
c. A & B d. None

31. What is the voltage rating of the AC motor used with


WRA?
a. 110V, AC b. 230V, AC
c. 415 V, AC d. None

32. What is the capacity of the motor provided in the WRA?


a. 1 HP b. 0.5 HP
c. 2 HP d. None
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 7

33. Which type of motor used in WRA?


a. Single phase induction b. Two phase induction
motor motor
c. Three phase induction d. None
motor

34. Which type of motor used in the pump set for WRA?
a. Squirrel cage b. Slip ring
c. A (or) B d. None

35. What is the main purpose of the pump controller?


a. To control WSP b. To control WRA
pump
c. To control contactors d. None of the above

36. What is the class of insulation of winding in the pump motor?


a. H- class b. F-class
c. E-class d. none of the above

37. What is the full load current of motor of pump set of WRA?
a. 1.1 Amp b. 1.5 Amps
c. 2.5 Amps d. 3.0 Amps

38. What is the rated speed of the pump set of WRA?


a. 1520 RPM b. 2800 RPM
c. 3000 RPM d. 3200 RPM

39. What is the total head of the pump set for WRA?
a. 3 mts. b. 5 mts.
c. 8 mts. d. 10 mts.
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 8

40. What is the discharging capacity of the pump set?


a. 0.5 LPS b. 0.7 LPS
c. 0.8 LPS d. 1.0 LPS

41. What is the suction flange size of the pump set of WRA?
a. 1” BSP b. 2’’ BSP
c. 3” BSP d. 4” BSP

42. What is the protection used in the monoblock pump set of


WRA?
a. Single phasing b. Overvoltage
c. Dry run d. All of above

43. How many pump sets provided in AC coach?


a. One b. Two
c. Three d. Four

44. Each pump in coach is alternately switched by the pump


controller for how many hours?
a. 6 hours b. 4 hours
c. 3 hours d. 2 hours

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 9

5 TECHNICAL DATA RMPU


45. What is the voltage of contactor coils of the LHB Variant
RMPUs control panel?
a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC

46. How many AC Package Unit (RMPU) provided in the


coaches?
a. 2 b. 3
c. 4 d. 1

47. What are the Main Features of Air Conditioning System?


a. Microprocessor b. Humidity control
controlled RMPU
c. NTC type d. All the above
temperature sensor

48. What is the Output Cooling capacity per unit?


a. 5.0 TR b. 6.0 TR
c. 7.0 TR d. 8.0 TR

49. What is the Output Heating capacity per unit?


a. 5.0 kW b. 6.0 kW
c. 7.0 kW d. 8.0 kW

50. What is the capacity of the Compressor motors per unit?


a. 5.0 kW b. 4.9 kW
c. 7.0 kW d. 6.0 kW

51. What is the Nominal power of unit?


a. 15 kVA b. 17.5 kVA
c. 16.5 kVA d. 17 kVA

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 10

52. What is the capacity of the Condenser Fan motor?


a. 1.5 HP b. 2 HP
c. 1 HP d. 2.5 HP

53. What is the capacity of the evaporator Fan motor radial?


a. 1.5 HP b. 2HP
c. 1 HP d. 2.5 HP

54. What is the volume of the Fresh air supply (m3/hr)?


a. 720 b. 820
c. 700 d. 800

55. What is the Maximum power input, cooling (kW)?


a. 12.25 b. 12.50
c. 13.25 d. 13.50

56. What is the Maximum power input, dehumidifying (kW)?

a. 10.0 Approximate b. 11.0 Approximate


c. 09.0 Approximate d. 12.0 Approximate

57. Which Refrigerant is used?


a. R 11 b. R 12
c. R 22, R407 C d. R 32

58. What is the Weight (kg) of unit?


a. 600 Approximate b. 610 Approximate
c. 620 Approximate d. 630 Approximate

59. What are the Dimensions (mm) of unit?


a. 2200 x 2000 x 500 b. 2200 x 2200 x 500
c. 2000 x 2200 x 500 d. 2000 x 2000 x 500
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 11

60. How much quantity of refrigerant is used in RMPU Make


Fedders Lloyd/LELL?
a. 3.2 kg per unit b. 4.2 kg per unit
c. 5.0 kg per unit d. 5.2 kg per unit

61. How much quantity of refrigerant is used in RMPU Make


Amit?
a. 2.0 kg per unit b. 2.2 kg per unit
c. 3.2 kg per unit d. 4.2 kg per unit

62. How much quantity of refrigerant is used in RMPU Make


SIDWAL/INTEC?
a. 1.85 kg per unit b. 2.00 kg per unit
c. 3.85 kg per unit d. 2.85 kg per unit

63. Each air conditioning package unit has how many cooling
circuits?
a. 1 b. 2
c. 3 d. 4

64. Each RMPU has how many compressors?


a. 4 b. 3
c. 2 d. 1

65. Each RMPU has how many condenser fans?


a. 3 b. 1
c. 4 d. 2

66. Each RMPU has how many Heating assemblies?


a. 1 b. 2
c. 3 d. 4

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 12

67. How many Maintenance covers are provided in the Each


RMPU?
a. 4 b. 6
c. 8 d. 10

68. How many Air inlets are provided for circulating air in each
RMPU?
a. 4 b. 3
c. 2 d. 1

69. How many Air inlets are provided for fresh air in each
RMPU?
a. 3 b. 1
c. 4 d. 2

70. How many Air outlet are provided for supply air in each
RMPU?
a. 1 b. 2
c. 3 d. 4

71. Each RMPU has how many mixed air filters?


a. 1 each b. 2 each
c. 3 each d. 4 each

72. Each RMPU has how many Fresh air filters?


a. 1 each b. 2 each
c. 3 each d. 4 each

73. How many Sealed Compressors are provided in the coach?


a. 1 b. 2
c. 3 d. 4

74. How many Condenser Motors are provided in the coach?


a. 4 b. 3
c. 2 d. 1
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 13

75. How many Heater units are provided in the coach?


a. 1 b. 2
c. 3 d. 4

76. How many Condenser Coil are provided in the coach?


a. 1 each b. 2 each
c. 3 each d. 4 each

77. How many Cooling Coil are provided in the coach?


a. 1 each b. 2 each
c. 3 each d. 4 each

78. What is the Amperes setting of Overload relay for the


Compressor Motor?
a. 09 Amperes b. 10 Amperes
c. 11 Amperes d. 12 Amperes

79. What is the Operation Time of the Compressor Motor


Overload Relay?
a. 24 Second b. 30 Second
c. 35 Second d. 40 Second

80. What is the Amperes setting of the Condenser Motor


Overload Relay?
a. 2.0 Amperes b. 2.4 Amperes
c. 3.0 Amperes d. 3.4 Amperes

81. What is the Operation Time of the Condenser Motor


Overload Relay?
a. 24 Second b. 30 Second
c. 34 Second d. 40 Second

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 14

82. What is the Amperes setting of the Blower Motor Overload


relay?
a. 1.0 Amperes b. 1.5 Amperes
c. 2.0 Amperes d. 2.4 Amperes

83. What is the Operation Time of the Blower Motor Overload


Relay?
a. 24 Second b. 30 Second
c. 34 Second d. 40 Second

84. What is the setting of the LP Cut Out?


a. 09 PSI b. 10 PSI
c. 11 PSI d. 12 PSI

85. What is the Operation Time of the LP Cut Out?


a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second

86. What is the setting of the HP Cut Out?


a. 200 PSI b. 225 PSI
c. 250 PSI d. 275 PSI

87. What is the Operation Time of the HP Cut Out?


a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 15

6 REGULATED CUM EMERGENCY BATTERY


CHARGER
88. What is the full form of RBC?
a. Regulated Battery b. Rectifier battery
Charger charger
c. Re generative battery d. None
charger

89. What is the full form of EBC?


a. Emergency Battery b. Electronic battery
Charger charger
c. Efficient battery charger d. None

90. What is the full form of REBC?


a. Regulated Cum b. Rectifier battery
Emergency Battery charger
Charger
c. Re generative battery d. None
charger

91. What is the Voltage rating & type of Battery used in LHB
AC coaches?
a. 1100 Ah’ VRLA b. 320 Ah’ VRLA
c. 120 Ah’ VRLA d. 70 Ah’ VRLA

92. What is the Voltage rating of each cell module in LHB AC


coaches?
a. 6 volts b. 12 volts
c. 18 volts d. 24 volts

93. What is the rating of the Regulated Battery Charger (of


RBC)?
a. 4.0 kW b. 4.5 kW
c. 5.0 kW d. 6.5 kW
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 16

7 REGULATED BATTERY CHARGER OF REBC


94. What is the capacity/output power of the Regulated Battery
Charger (of REBC)?
a. 4.0 kW b. 4.5 kW
c. 5.0 kW d. 6.5 kW

95. What is the Input Voltage of Regulated Battery Charger (of


REBC)?
a. 110 Volt AC b. 110 Volt DC
c. 220 Volt AC d. 415 Volt AC

96. What is the output Voltage of Regulated Battery Charger (of


REBC)?
a. 110 to 135 Volts DC b. 110 to 135 Volts AC
c. 220 to 235 Volts DC d. 220 to 235 Volts AC

97. What is the output Voltage of Regulated Battery Charger (of


REBC) during normal operation of battery charging?
a. 122 volts ±10% b. 122 volts ±2%
c. 110 volts ±20% d. 120 volts ±20%

98. What is the Output current of Regulated Battery Charger (of


REBC)?
a. 15 A b. 20 A
c. 25 A d. 35 A

99. What is the voltage ripple of a Regulated Battery Charger


(of REBC)?
a. ≤ 1 % of the set voltage b. ≤ 2 % of the set voltage
c. ≤ 3 % of the set voltage d. ≤ 4 % of the set voltage

100. What is the Current ripple of RBC (OF REBC)?


a. ≤ 1 % of the set Current b. ≤ 2 % of the set Current
c. ≤ 3 % of the set Current d. ≤ 4 % of the set Current
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 17

101. What is the Dimension of the charger unit as per RDSO


Specification?
a. 900x400x600 mm b. 950x440x650 mm
c. 920x450x650 mm d. 900x440x650 mm

102. What is the Weight of the charger unit as per RDSO


Specification?
a. <100 kg. b. <110 kg.
c. <120 kg. d. <130 kg

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 18

8 EMERGENCY BATTERY CHARGER (OF REBC)


103. What is the capacity/output power of the Emergency Battery
Charger (of REBC)?
a. 1.0 kW b. 1.5 kW
c. 2.0 kW d. 2.5 kW

104. What is the Input Voltage of Emergency Battery Charger (of


REBC)?
a. 240 V ± 15% AC b. 415 V ± 15% AC
c. 110 V ± 15% DC d. 240 V ± 15% DC

105. What is the Output current of Emergency Battery Charger


(of REBC)?
a. 15 A b. 20 A
c. 22 A d. 30 A

106. What is the Efficiency of Emergency Battery Charger (of


REBC)?
a. ≥ 80% @ Full Load b. ≥ 85% @ Full Load
c. ≥ 90% @ Full Load d. ≥ 95% @ Full Load

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 19

9 PROTECTIONS FOR REGULATED BATTERY


CHARGER
107. What is the voltage setting for the input AC under-voltage
protection?
a. 280 ± 5V AC b. 300 ± 5V
c. 320 ± 5V d. 380 ± 5V

108. What is the voltage setting for the input AC over-voltage


protection?
a. 430 ± 5V b. 450 ± 5V
c. 480 ± 5V d. 460 ± 5V

109. What is the voltage setting for the output over-voltage


protection?
a. 120 ± 2 V DC b. 130 ± 2 V DC
c. 136 ± 2 V DC d. 140 ± 2 V DC

110. What is the Ampere setting for the Overload protection?


a. 15+20% Amp. b. 20+20% Amp.
c. 35+10% Amp. d. 35+20% Amp.

111. How many amperes three pole MCBs are installed for AC
input protection?
a. 10 Amp. b. 15 Amp.
c. 20 Amp. d. 25 Amp.

112. Which fuses are installed for output protection?


a. 20 Amp. HRC fuse b. 25 Amp. HRC fuse
c. 30 Amp. HRC fuse d. 40 Amp. HRC fuse

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 20

10 PROTECTIONS FOR EMERGENCY BATTERY


CHARGER
113. How many volts set for the Input supply overvoltage?
a. 240 +05%V b. 240 +10%V
c. 240 +15%V d. 240 +20%V

114. How many volts set for the Input supply under-voltage?
a. 240- 05%V b. 240 - 10%V
c. 240 - 15%V d. 240 - 20%V

115. How many ampere single pole MCBs are installed for AC
input protection?
a. 10 Amp. b. 15 Amp.
c. 20 Amp. d. 25 Amp.

116. What is the current limit for Output?


a. 10 Amps. b. 15 Amps.
c. 20 Amps. d. 24 Amps.

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 21

11 LIGHT FITTINGS
117. What is the rating of the control Transformer used for the
Mobile/laptop charger circuit?
a. 1 kVA b. 2.5 kVA
c. 3 kVA d. 5 kVA

118. What is the input voltage of the control Transformer used


for the Mobile/laptop charger circuit?
a. 110 V AC b. 230 V AC
c. 415 V AC d. 750 V AC

119. What is the Lighting circuit operating Voltage?


a. 12 V DC b. 24 V DC
c. 110 V DC d. 110 V AC

120. What is the type of Toilet exhaust fans used in the LHB AC
coach?
a. Single inlet b. Double inlet
centrifugal type centrifugal type
c. Radial type d. None

121. What is the minimum insulation resistance of 750 Volts


wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms

122. What is the minimum insulation resistance of 415 Volts


wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 22

123. What is the minimum insulation resistance of 110 Volts


wiring and equipment?
a. 1 Mega Ohms b. 2 Mega Ohms
c. 3 Mega Ohms d. 5 Mega Ohms

124. What is the rating of DC main fuses in LHB Coach?


a. 16 Amps b. 25 Amps
c. 40 Amps d. 60 Amps

125. What is the setting of the feeder earth leakage relay?


a. 1 Amps b. 2 Amps
c. 3 Amps d. 5 Amps

126. What is the setting of the feeder overload load relay?


a. 200 Amps b. 250 Amps
c. 300 Amps d. 400 Amps

127. What is the rating of Transformer provided for Feeder


contactor control?
a. 100 VA b. 150 VA
c. 200 VA d. 250 VA

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 23

12 BATTERY
128. What is the rating of the battery provided in the LHB Non-
AC coach?
a. 70 AH b. 100 AH
c. 110 AH d. 120 AH

129. How many 70 Ah VRLA battery modules are used in the


LHB coach?
a. 56 cells b. 18 mono block
c. 9 modules of 12V d. 19 modules of 6V
each each

130. What is the rating of Battery fuse in LHB Non-AC coaches?


a. 16 A b. 32 A
c. 35 A d. 40 A

131. What is the type of tray provided inside the battery box for
the placing of batteries?
a. FRP tray b. Steel tray
c. Plastic tray d. On battery box directly

132. What is the means of the FRP?


a. Fire Retardant b. Fibre Reinforced Plastic
Plastic
c. Fire Reduced Plastic d. Fire Retardant Pipe

133. What is the kind of paint used to paint the battery box?
a. Ordinary Enamel b. Distemper paint
c. Anti-corrosive Fire d. None of the above
retardant

134. Which type of material is used to make a battery container?


a. Hard rubber or PPCP b. PVC
c. Steel d. FRP
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 24

135. What is Liberation of gases at anode and cathode of a Lead


Acid cell called?
a. Recombination b. Gassing
c. Stratification d. None of the above

136. What is method adopted to keep the cells Voltage in


uniform condition?
a. Boost charging b. Normal charging
c. Equalizing charging d. Trickle charging

137. What are the means of Boost charging and with what
capacity charging is done?
a. 1/2th of rated current b. Higher rate for short
for 5 Hours period @ 2.25 V/cell
c. Rated current for 1 hour d. None of the above

138. What is the charging current for boost charging?


a. 1.5 X normal charge b. 2 times the normal
rate current
c. 2.5 times the normal d. 3 times the normal
current current

139. What is the voltage per cell maintained for float charging?
a. 1.8 V/cell at constant b. 2.0V/cell at constant
potential mode potential mode
c. 2.2V/cell at constant d. 2.4V/cell at constant
potential mode potential mode

140. What is the capacity of the battery is expressed in?


a. Ampere hours b. Watts
c. Watt -Hours d. Horse Power

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 25

141. What are the modes of charging a Lead Acid Battery?


a. Constant potential b. Constant current mode
mode
c. Both A&B d. None of the above

142. What is the full form of VRLA?


a. Valve Regulated b. Valve released lead Acid
Lead Acid Cell Cell
c. Valve Regulated d. None of the above
Low Acid Cell

143. What is the working principle of the VRLA battery?


a. Pressure release b. Hydrogen recombination
c. Oxygen d. None of the above
recombination

144. What else is a VRLA battery called?


a. Maintenance-free b. Sealed maintenance-free
batteries (SMF) Cell
c. Sealed Cell d. None of the above

145. To increase the voltage of the battery, cells are connected in


a. Series b. Parallel
c. Series/Parallel d. None of the above

146. What is the main purpose for providing the battery bank?
a. Alternator b. Supply to the coach in
Voltage is case of feeder supply
fluctuating failure.
c. Battery Voltage is d. None of the above
constant

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 26

147. What is the applied with cell connecter to prevent


sulphation?
a. Paint b. Kerosene
c. Grease d. Petroleum jelly

148. What is the method of charging recommended for VRLA


batteries?
a. Constant current b. Constant voltage
c. Constant Voltage d. None of the above
Constant Current

149. What is the open-circuit voltage of the battery bank used for
AC Coaches with VRLA battery?
a. 100 V b. 105 V
c. 115V d. 130 V

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 27

13 EOG POWER CAR


150. What is the Speed potential of a power car coach?
a. 140 kmph. b. 160 kmph.
c. 180 kmph. d. 200 kmph.

151. What is the capacity of roof mounted AC unit in a power


car?
a. 1x6 Ton b. 2x6 Ton
c. 1x7 Ton d. 2x7 Ton

152. How many Power Transformers provided in the power car?


a. 1 b. 2
c. 3 d. 4

153. What is the capacity of Transformers provided in the power


car?
a. 60 kVA, Star- Delta b. 60 kVA, Star -Star
c. 60 kVA, Delta - d. 60 kVA, Delta- Star
Delta

154. What is the input Voltage of Transformers?


a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None

155. What is the output Voltage of Transformers?


a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 28

156. How many DG set provided in the power car?


a. 1 b. 2
c. 3 d. 4

157. What is the capacity of the DG Set Engine?


a. 450 BHP b. 470 BHP
c. 496 BHP d. 500 BHP

158. What is the capacity of the DG Set Alternator?


a. 300 kVA at NTP b. 400 kVA at NTP
c. 500 kVA at NTP d. 600 kVA at NTP

159. What is the output Voltage of the Alternator?


a. 190 Volts, Single b. 230 Volts, Single
Phase, 2 wires Phase, 2 wires
c. 415 Volts, 3 Phase, 4 d. 750 Volts, 3 Phase, 4
wires wires

160. What is the Rating of the Air-Circuit breaker used for


Alternator output?
a. 410 amps b. 520 amps
c. 610 amps d. 800 amps

161. What is the Rating of feeder contactor used in LHB Power


car?
a. 400 amps b. 520 amps
c. 630 amps d. 800 amps

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 29

162. In LHB Power Car NWP contactor means?


a. Non-Working Power b. New working power
Car contactor contactor
c. Network power d. None
contactor

163. What is AVR means in LHB Power Car?


a. Automatic variable b. Automatic voltage
regulator regulator
c. Anti vibration d. None
regulator

164. How many Diesel tanks provided in the LHB Power Car?
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.

165. What is the total capacity of the Diesel tank provided in the
LHB Power Car?
a. 1500 liters b. 2000 liters
c. 2500 liters d. 3000 liters

166. What is the capacity of each Diesel tank in the LHB Power
Car?
a. 1500 liters b. 2000 liters
c. 2500 liters d. 3000 liters

167. How much Water storage tank provided?


a. 1 x 685 litres b. 2 x 685 litres
c. 1 x 650 litres d. 1 x 665 litres

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 30

168. What is the capacity of the DG Set Radiator fan?


a. 30 HP b. 40 HP
c. 50 HP d. 60 HP

169. What is the input Voltage for the DG Set Radiator fan
motor?
a. 750 Volts, 3Phase b. 415 Volts, 3Phase
c. 215 Volts, 1Phase d. None

170. What should be used in radiators for cooling of the D G set?


a. Ordinary Water b. Distilled Water
c. Coolants d. None

171. How many Ventilation fans provided in the power car?


a. 1 b. 2
c. 3 d. 4

172. How many Ventilation Motors provided in the power car?


a. 1 No. b. 2 Nos.
c. 3 Nos. d. 4 Nos.

173. What is the capacity of the Ventilation fans motor?


a. 6.0 HP b. 6.5 HP
c. 7.0 HP d. 7.5 HP

174. What is the capacity of the Starter battery?


a. 120 Ah b. 290 Ah
c. 320 Ah d. 1100 Ah

175. What is the input voltage of the Starter battery Charger?


a. 110 V, DC b. 230 V, AC
c. 415 V, AC d. None
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 31

176. Which type of temperature controller is installed?


a. Fine control in 3 b. Fine control in 4
steps steps
c. Fine control in 5 d. Fine control in 6
steps steps

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 32

14 RELAY FOR PROTECTION OF GENERATOR CAR


177. What is the setting of the over-speed relay switch?
a. 1400 ± 4.5 % RPM b. 1600 ± 4.5 % RPM
c. 1800 ± 4.5 % RPM d. 2000 ± 4.5 % RPM

178. What are the permissible limits of LOP (Low Oil Pressure)
for Cummins engine?
a. 2.166.33 kg/sqcm. b. 3.16, 6.33 kg/sqcm.
c. 3.16,6.50 kg/sqcm. d. 4.16, 6.33 kg/sqcm.

179. How many Amperes are set for the alternator earth leakage
relay?
a. 2.0 Amperes b. 2.5 Amperes
c. 3.0 Amperes d. 3.5 Amperes

180. What is the Operation Time of the Alternator Earth Leakage


Relay?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second

181. How many Amperes are set for the Feeder earth leakage
relay?
a. 2.0 Amperes b. 2.5 Amperes
c. 3.0 Amperes d. 3.5 Amperes

182. What is the Operation Time of the Feeder Earth Leakage


Relay?
a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second

183. How many Volts are set for the Under-Voltage relay?
a. 300 Volts b. 350 Volts
c. 375 Volts d. 400 Volts
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 33

184. What is the Operation Time of the Under-Voltage Relay?


a. 6.0 Second b. 7.0 Second
c. 8.0 Second d. 9.0 Second

185. How many Amperes are set for the Feeder Overload Relay?
a. 200 Amperes b. 300 Amperes
c. 350 Amperes d. 400 Amperes

186. What is the Operation Time of the Feeder Overload Relay?


a. 20 Second b. 25 Second
c. 30 Second d. 35 Second

187. How many Amperes are set for the Air Circuit Breaker?
a. 300 Amperes b. 360 Amperes
c. 350 Amperes d. 400 Amperes

188. What is the Operation Time of the Air Circuit Breaker?


a. 0.5 Second b. 1.0 Second
c. 1.5 Second d. 2.0 Second

189. How many RPM is set for the Over Speed Relay?
a. 1600 RPM b. 1700 RPM
c. 1800 RPM d. 1900 RPM

190. What is the Operation Time of the Over Speed Relay?


a. < 1Second b. > 1Second
c. < 2 Second d. > 2 Second

191. How much is set for the High-Water Temperature INTAC


Engine?
a. 100 ºC b. 107 ºC
c. 110 ºC d. 115 ºC
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 34

192. How much is set for the High-Water Temperature


CUMMINS Engine?
a. 90 ºC b. 95 ºC
c. 97 ºC d. 100 ºC

193. Which type of Fire extinguishers is used in the power car?


a. Soda Acid type b. Water Foam based type.
c. Dry Powder Type d. C.T.C & CO2 type

194. Which capacity fuses are used for the protection of the
incoming side of 750 volts in LHB?
a. 3 x 60 A HRC b. 3 x 63 A HRC fuses
fuses
c. 3 x 65 A HRC d. Incoming feeder directly
fuses on the contactors

195. Which capacity fuses are used for the protection of the
incoming side of 415 volts?
a. 3 x 60 A HRC b. 3 x 70 A HRC fuses
fuses
c. 3 x 80 A HRC d. 3 x 100 A HRC
fuses fuses
196. What is the Coach length of the LHB power car?
a. 23.3 meters b. 23.5 meters
c. 23.8 meters d. 24.0 meters

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 35

15 PANTRY CAR AND MINI PANTRY EQUIPMENT

197. What are the Dimensions of Hot case provided in mini pantry
of coaches?
a. 900 x 1050 x 600 mm b. 900 x 1050 x 605 mm
c. 910 x 1092 x 600 mm d. 950 x 1092 x 600 mm

198. What is the operating volt of hot case provided in mini pantry
of coaches?
a. 110 Volt b. 230 Volt
c. 415 Volt d. 110 Volt DC

199. What is the capacity of the Heating element of hot case


provided in the mini pantry of coaches?
a. 3 x 500 Watt or 2 x 500 watt b. 750 Watt
c. 1800 Watt d. 2000 Watt

200. What is the Operating temperature of hot case provided in the


mini pantry of coaches?
a. 60 ºC b. 70 ºC
c. 80 ºC d. 90 ºC

201. What is the range of the Thermostat of Hot case provided in


the mini pantry of coaches?
a. 30 – 80° C b. 40 – 80° C
c. 50 – 80° C d. 60 – 80° C

202. What are the Dimensions of Refrigerating Unit provided in


mini pantry of coaches?
a. 1100 x 595 x 1195 mm b. 1157 x 550 x 1195 mm
c. 1157 x 595 x 1195 mm d. 1157 x 595 x 1150 mm

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 36

203. What is the power of the Refrigerating Unit provided in the


mini pantry of coaches?
a. 500 Watt b. 600 Watt
c. 700 Watt d. 800 Watt

204. What is the Refrigeration capacity of the Refrigerating Unit


provided in the mini pantry of coaches?
a. 550 kCal/Hr. b. 560 kCal/Hr.
c. 570 kCal/Hr. d. 580 kCal/Hr.

205. Which Refrigerant is used in the Refrigerating Unit provided


in the mini pantry of coaches?
a. R11 b. R12
c. R22 d. R32

206. What is the Thermostat range of the Deep freezer provided in


the mini pantry of coaches?
a. -18 to -25°C b. -20 to -25°C
c. -20 to -30°C d. -22 to -25°C

207. What is the Thermostat range of the Bottle cooler provided in


the mini pantry of coaches?
a. 2 to + 10°C b. 3 to + 5°C
c. 0 to + 05°C d. 3 to + 15°C

208. What is the capacity of the Bottle cooler provided in the mini
pantry of coaches?
a. 70 Bottle of 1.0 liter b. 80 Bottle of 1.0 liter
c. 90 Bottle of 1.0 liter d. 100 Bottle of 1.0 liter

209. What is the Thermostat range of the Cooling compartment of


the Refrigerating Unit provided in the mini pantry of
coaches?
a. 0 to + 03°C b. 0 to + 05°C
c. 0 to + 10°C d. 0 to + 15°C
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 37

210. What are the Dimensions of the Bottle Cooler provided in the
mini pantry of coaches?
a. 900x600x900 b. 910x620x900 mm
c. 910x600x940 mm d. 910x600x900 mm

211. What is the Power consumption of the Bottle Cooler provided


in the mini pantry of coaches?
a. 200 watt b. 400 watt
c. 450 watt d. 500 watt

212. What is the Capacity of the Soup Warmer for Food insert
provided in the mini pantry of coaches?
a. 10 litres b. 12 litres
c. 13 litters d. 14 litres

213. What is the Capacity of the Soup Warmer for heating medium
provided in the mini pantry of coaches?
a. 0.4 litres of water b. 0.5 litres of water
c. 0.6 litres of water d. 0.7 litres of water

214. What is the maximum power of the Soup Warmer provided in


the mini pantry of coaches?
a. 450 watts b. 475 watts
c. 500 watts d. 550 watts

215. What is the nominal current of the Soup Warmer provided in


the mini pantry of coaches?
a. 1.5 Amp. b. 2.0 Amp.
c. 2.2 Amp. d. 2.5 Amp.

216. What is the Weight of the Soup Warmer provided in the mini
pantry of coaches?
a. 4.0 kg b. 4.5 kg
c. 5.0 kg d. 5.5 kg
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 38

217. What is the Thermostat Lower temperature range of the Soup


Warmer provided in the mini pantry of coaches?
a. 60-62° C b. 62-65° C
c. 70-72° C d. 72-75° C

218. What is the Thermostat High-temperature range of the Soup


Warmer provided in the mini pantry of coaches?
a. 80-82° C b. 82-85° C
c. 85-87° C d. 90-92° C

219. The cooking table is divided into how many parts.


a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.

220. How many Insect killers provided in the pantry car?


a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.

221. How many Oven Toaster Griller provided in the pantry car?
a. 1 no. b. 2 nos.
c. 3 nos. d. 4 nos.

222. What is the Capacity of hot water boiler provided in Mini-


pantry of LHB AC coach?
a. 12 litres b. 15 litres
c. 20 litres d. 25 litres

223. What is the rating of hot water boiler provided in LHB AC


coach?
a. 2 KW b. 3 KW
c. 5 KW d. None

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 39

16 LHB NON AC COACH


224. How much input Voltage of feeder contactor coil is in the
LHB Non-AC coaches?
a. 110 V AC b. 110 V DC
c. 415 V AC d. None of the above

225. What is the rating of feeder contactor coil circuit


Transformer in LHB Non-AC coaches?
a. 100 VA b. 110 VA
c. 150 VA d. None of the above

226. What is the rating of the main power transformer in LHB


Non-AC chair car coaches?
a. 09 KVA b. 10 KVA
c. 12 KVA d. 15 KVA

227. The no. of panels available in LHB Non-AC coach are


a. 2 b. 3
c. 4 d. None of the above

228. What is the rating of the main power transformer in LHB


Non-AC coaches?
a. 09 KVA b. 10 KVA
c. 12 KVA d. None of the above

229. How many fuses available in a Power transformer?


a. 3 Nos. b. 5 Nos.
c. 7 Nos. d. 9 Nos.

230. What is the input voltage of the power transformer?


a. 230 V b. 415 V
c. 750 V d. None of the above

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 40

231. What is the output voltage of the power transformer?


a. 190/110 V b. 415 V
c. Both A & B d. None of the above

232. Power transformer is connected in


a. star-delta b. delta-delta
c. star-star d. delta- star

233. What is the class of insulation of winding in the


transformer?
a. H- class b. F-class
c. E-class d. none of the above

234. The transformer fitted in the under slung with How much
anti-vibration?
a. 2 b. 4
c. 6 d. none of the above

235. How much secondary winding available in the power


transformer?
a. 1 b. 2
c. 3 d. 4

236. What is the rating of fuse provided for the main HT 750
Volts of Transformer input circuit in LHB Non-AC coach?
a. 16 Amp b. 25 Amp
c. 30 Amp d. 40 Amp

237. What is the purpose of RCBO provided in LHB non-ac


coaches?
a. Protection against b. Protection for
electric shock equipment
c. both a & b d. None of the above
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 41

238. What is the operating Voltage of Lights & fans in the LHB
Non-AC coach?
a. 415 V AC b. 230 V AC
c. 110 V AC d. 110 V DC

239. What are the meaning of an HV?


a. High voltage b. Heavy voltage
c. Both A & B d. None of the above

240. Where HV panel is mounted in the coach?


a. Near the LV Panel b. Roof
c. Under frame d. None of the above

241. What are the meaning of an LV?


a. Lower voltage b. Low voltage
c. Both A & B d. None of the above

242. Where LV panel is mounted in the coach?


a. Near the HV Panel b. Onboard
c. Under frame d. None of the above

243. What is the size of the fuse provided for the main circuit of
lights and fans?
a. 06 Amps b. 10 Amps
c. 16 Amps d. 20 Amps

244. Which type of light used for night lights in LHB Non-AC
coach?
a. IC lamps b. CFL
c. FL d. LED

245. How much total connected load in 3 Tier Sleeper LHB Non-
AC coaches?
a. 1104 W b. 1906 W
c. 2206 W d. 3000 W
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 42

246. How much total connected load in GS (LS) LHB Non-AC


coaches?
a. 1906 W b. 2124 W
c. 2206 W d. 3000 W

247. How much total connected load in Chair Car LHB Non-AC
coaches?
a. 1906 W b. 2124 W
c. 2193 W d. 3000 W

248. How many fans available in LHB Non-AC coaches?


a. 27 b. 30
c. 33 d. 36

249. What is the rating of BLDC, carriage fans used in LHB


Non-AC coaches?
a. 27 W b. 30 W
c. 38 W d. 40 W

250. What is the size of the fan used in LHB Non-AC coaches?
a. 100 mm sweep b. 200 mm sweep
c. 300 mm sweep d. 400 mm sweep

251. What is the suitable range of working voltage of the BLDC


fan?
a. 80 -110 V DC b. 80 -120 V DC
c. 90 -140 V DC d. 90 -140 V AC

252. How many mm wide color bands are there on the


circumference of the fan body in a BLDC fan?
a. 10 mm b. 20 mm
c. 30 mm d. 40 mm

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 43

253. Which color of the two bands is in BLDC fan?


a. Green & Yellow b. Green & Red
c. Red & Yellow d. Blue & Yellow

254. How many Emergency lights (AEL) are provided in LHB


Non-AC coach?
a. 2 b. 4
c. 6 d. 8

255. What is the charging Voltage of the Accident Emergency


light?
a. 415 V AC b. 230 V AC
c. 110 VAC d. 110 VDC

256. What is the type of cables used in LHB Non-AC coaches?


a. Elastomeric cable b. PILC
c. XLPE d. PVC

257. Which color is adopted for the wiring of light positive cable
in LHB Non-AC coaches?
a. RED b. YELLOW
c. BLUE d. BLACK

258. Which color is adopted for the wiring of fan negative cable
in LHB Non-AC coaches?
a. RED b. YELLOW

c. BLUE d. BLACK

259. Which color is adopted for the wiring of fan positive cable
in LHB Non-AC coaches?
a. RED b. BLUE
c. BLACK d. YELLOW
Question Bank on LHB Coaches (Electrical) March, 2021
CAMTECH/E/EP-03/202-21/QB-LHB/1.0 44

260. Which color is adopted for the wiring of all negative except
fan negative cable in LHB Non-AC coaches?
a. RED b. YELLOW
c. BLUE d. BLACK

261. Which is the main feeder contactor for feeder 1?


a. K 01 b. K 02
c. Both A & B d. None of the above

262. Which is the main feeder contactor for feeder 2?


a. K 01 b. K 02
c. Both A & B d. None of the above

263. What is the purpose of the push-button provided in the LV


panel?
a. To check Rotary b. To check Mobile charger
switch
c. To check Emergency d. None of the above
light

264. How many types of voltages are used in an under-slung HV


panel?
a. 750 V b. 415 V
c. 190/110 V d. All the above

265. How many types of voltages are used in an onboard LV


panel?
a. 190 V AC b. 110 V AC
c. 110 V DC d. All the above

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 45

266. What is the size of cable used for R, Y, B phases in the


feeder junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm

267. What is the size of cable used for Neutral in a feeder


junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm

268. What is the size of cable used for Earth in the feeder
junction box?
a. 70 sq. mm b. 95 sq. mm
c. 125 sq. mm d. 150 sq. Mm

269. What is the size of the cable used for the control cable?
a. 1.5 sq. mm b. 2.5 sq. mm
c. 10 sq. mm d. 25 sq. Mm

270. What is the size of cable used from Feeder to HV panel?


a. 10 sq. mm b. 16 sq. mm
c. 25 sq. mm d. 35 sq. Mm

271. What is the size of cable used from HV panel to Power


Transformer?
a. 10 sq. mm b. 25 sq. mm
c. 35 sq. mm d. 70 sq. Mm

272. What is the Disconnecting and earthing device?


a. OFF load switch b. ON load switch
c. Both A & B d. None of the above

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 46

273. Which equipment is used to prevent return current flow


through-axle bearing?
a. D & ED b. Transformer
c. Wheel set earthing d. None of the above
equipment

274. What is the rating of the glass fuse used in the mobile
charging socket?
a. 200 mA b. 500 mA
c. 600 mA d. None of the above

275. What is the operating voltage of Pantry equipment in an


LHB Non-AC chair car?
a. 110 V DC b. 110 V AC
c. 230 V AC d. 415 V AC

276. What is the meaning of WSP?


a. Pump b. Pantry
c. AC Plant d. Anti Skid Device

277. What is the meaning of AVM?


a. Anti vibration b. Auto vibration
mounting mounting
c. Automatic voltages d. None of the above
monitor

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 47

17 FILL IN THE BLANKS


What are the codes of various LHB coaches in Indian Railways?

Fill in the blanks.

a. Code of First AC EOG LHB Coaches is the...........................

b. Code of AC 2 Tier SG LHB Coaches is the............................

c. Code of AC 2 Tier EOG LHB Coaches is the.........................

d. Code of AC 3 Tier SG LHB Coaches is the............................

e. Code of AC 3 Tier EOG LHB Coaches is the.........................

f. Code of Executive AC chair car of is the …….......................

g. Code of AC chair car EOG LHB Coaches is the....................

h. Code of AC Pantry Car EOG LHB Coaches is the................

i. Code of Generator Car LHB Coaches is the..........................

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 48

ANSWERS

1. GENERAL QUESTIONS
1. - (b) 2. - (c) 3. - (c) 4. - (b) 5. - (c)
06. - (d)

2. MAINTENANCE SCHEDULE
07. - (c) 08. - (b) 09. - (d) 10. - (b) 11. - (d)
12. - (d) 13. - (b) 14. - (c) 15. - (d)

3. TECHNICALLY QUESTIONS
16. - (b) 17. - (c) 18. - (a) 19. - (d) 20. - (d)
21. - (c) 22. - (b) 23. - (a) 24. - (c) 25. - (c)

4. WRA
26. - (b) 27. - (b) 28. - (d) 29. - (b) 30. - (b)
31. - (c) 32. - (b) 33. - (c) 34. - (a) 35. - (b)
36. - (b) 37. - (a) 38. - (b) 39. - (c) 40. - (b)
41. - (a) 42. - (d) 43. - (b) 44. - (b)

5. TECHNICAL DATA RMPU


45. - (a) 46. - (a) 47. - (d) 48. - (c) 49. - (b)
50. - (b) 51. - (c) 52. - (c) 53. - (a) 54. - (b)
55. - (c) 56. - (b) 57. - (c) 58. - (d) 59. - (a)

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 49

60. - (b) 61. - (c) 62. - (d) 63. - (b) 64. - (c)
65. - (d) 66. - (a) 67. - (b) 68. - (c) 69. - (d)
70. - (a) 71. - (d) 72. - (d) 73. - (d) 74. - (a)
75. - (b) 76. - (d) 77. - (d) 78. - (b) 79. - (d)
80. - (b) 81. - (c) 82. - (b) 83. - (a) 84. - (b)
85. - (a) 86. - (b) 87. - (a)

6. REGULATED CUM EMERGENCY BATTERY


CHARGER

88. - (a) 89. - (a) 90. - (a) 91. - (d) 92. - (b)
93. - (d)

7. REGULATED BATTERY CHARGER OF REBC

94. - (b) 95. - (d) 96. - (a) 97. - (b) 98. - (d)
99. - (b) 100. - (c) 101. - (d) 102. - (c)

8. EMERGENCY BATTERY CHARGER (OF REBC)

103. - (d) 104. - (a) 105. - (c) 106. - (c)

9. PROTECTIONS FOR REGULATED BATTERY


CHARGER

107. - (b) 108. - (c) 109. - (c) 110. - (d) 111. - (c)
112. - (d)

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 50

10. PROTECTIONS FOR EMERGENCY BATTERY


CHARGER
113. - (c) 114. - (c) 115. - (c) 116. - (d)

11. LIGHT FITTING


117. - (b) 118. - (b) 119. - (c) 120. - (b) 121. - (d)
122. - (c) 123. - (b) 124. - (b) 125. - (c) 126. - (c)
127. - (a)

12. BATTERY
128. - (a) 129. - (c) 130. - (d) 131. - (a) 132. - (b)
133. - (c) 134. - (a) 135. - (b) 136. - (c) 137. - (b)
138. - (a) 139. - (d) 140. - (a) 141. - (c) 142. - (a)
143. - (c) 144. - (b) 145. - (a) 146. - (b) 147. - (d)
148. - (c) 149. - (c)

13. EOG POWER CAR


150. - (b) 151. - (c) 152. - (c) 153. - (b) 154. - (a)
155. - (b) 156. - (b) 157. - (c) 158. - (c) 159. - (d)
160. - (d) 161. - (c) 162. - (a) 163. - (b) 164. - (b)
165. - (d) 166. - (a) 167. - (c) 168. - (b) 169. - (b)
170. - (c) 171. - (b) 172. - (b) 173. - (d) 174. - (b)
175. - (b) 176. - (c)

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 51

14. RELAY FOR PROTECTION OF GENERATOR CAR


177. - (c) 178. - (b) 179. - (b) 180. - (a) 181. - (c)
182. - (a) 183. - (c) 184. - (c) 185. - (b) 186. - (c)
187. - (b) 188. - (a) 189. - (c) 190. - (a) 191. - (b)
192. - (c) 193. - (c) 194. - (b) 195. - (d) 196. - (b)

15. PANTRY CAR AND MINI PANTRY EQUIPMENT

197. - (c) 198. - (b) 199. - (a) 200. - (c) 201. - (a)
202. - (c) 203. - (d) 204. - (b) 205. - (c) 206. - (a)
207. - (b) 208. - (c) 209. - (c) 210. - (d) 211. - (a)
212. - (b) 213. - (c) 214. - (b) 215. - (c) 216. - (b)
217. - (c) 218. - (d) 219. - (c) 220. - (b) 221. - (a)
222. - (b) 223. - (a)

16. LHB NON AC COACH


224. - (c) 225. - (a) 226. - (d) 227. - (a) 228. - (a)
229. - (d) 230. - (c) 231. - (c) 232. - (c) 233. - (a)
234. - (b) 235. - (b) 236. - (b) 237. - (a) 238. - (d)
239. - (a) 240. - (c) 241. - (b) 242. - (b) 243. - (c)
244. - (d) 245. - (c) 246. - (b) 247. - (c) 248. - (b)
249. - (c) 250. - (d) 251. - (c) 252. - (b) 253. - (a)
254. - (b) 255. - (d) 256. - (a) 257. - (b) 258. - (d)
259. - (a) 260. - (c) 261. - (a) 262. - (b) 263. - (c)

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 52

264. - (d) 265. - (d) 266. - (d) 267. - (b) 268. - (a)
269. - (b) 270. - (c) 271. - (b) 272. - (a) 273. - (c)
274. - (b) 275. - (c) 276. - (d) 277. - (a)

17. FILL IN THE BLANKS: CODES OF VARIOUS LHB


COACHES
a. LWFAC b. LWGACCW c. LWACCW
d. LWGACCN e. LWACCN f. LWFCZAC
g. LWSCZAC h. LWCBAC i. LWLRRM

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 53

 NOTE 

Question Bank on LHB Coaches (Electrical) March, 2021


CAMTECH/E/EP-03/202-21/QB-LHB/1.0 54

CAMTECH is continuing its efforts in the documentation and up-gradation


of information on maintenance practices of electrical assets. Over the years a
large number of publications on electrical assets have been prepared in the
form of handbooks, pockets books, pamphlets & video films etc. These
publications have been uploaded on the internet as well as rail net.

For downloading these publications please do following:

1. On internet visit :www.rdso.indianrailways.gov.in

Go to Directorates  CAMTECH  Publications for download


Electrical Engineering

2. On Railnet visit RDSO website at 10.100.2.19

Go to Directorates  CAMTECH Publications for download 


Electrical Engineering

For any further information regarding publications please contact:

Dy. Director (Elect.) BSNL: 0751- 2470740 (O)


Rly. : 03747203
SSE/Electrical : 9425341810

E-mail : direlcamtech@gmail.com
Fax : 0751- 2470841
Write at : Dy. Director (Electrical)
Indian Railways
Centre for Advanced Maintenance
technology, In front of Hotel Adityaz,
Airport Road, Maharajpur,
Gwalior, Pin code – 474 005

Question Bank on LHB Coaches (Electrical) March, 2021