Readout of DEUTZ EMR3 Blink-Code

Readout of DEUTZ
Blink Codes
(for machines equipped with a EMR3)

HAMM AG 1/10 # 2138392


30.11.2009
INDEX

INDEX:

1. INSTRUCTIONS FOR USE 3

1.1 LIABILITY EXCLUSION 3


1.2 IMPORTANT SYMBOLS IN THE MANUAL: 3
1.3 SECURITY ADVICE 3

2. SERIES 3000 4

2.1 PREPARATIONS 4
2.2 READOUT OF BLINK-CODES 5

3. SERIES HD 7

3.1 PREPARATIONS 7
3.2 READOUT OF BLINK-CODES 8

NOTES 10

HAMM AG 2/10 # 2138392


30.11.2009
Instructions for use

1. Instructions for use


1.1 Liability exclusion
This manual should assist service technicians with the readout of the Deutz Diagnostic
Trouble codes via Blink-Code. The general safety and accident prevention regulations ap-
ply. Company HAMM AG cannot be made liable for occurrences caused by the application
of the steps recommended in this document.

1.2 Important symbols in the manual:

! Security advices

9 Necessary information

; General information

1.3 Security advice

! Prior to starting work make sure that the battery isolation switch has been
disconnected!

HAMM AG 3/10 # 2138392


30.11.2009
Series 3000

2. Series 3000
2.1 Preparations

8 Ignition switched off!

 Open switchbox (right side of


machine)

 Disassemble four knurled nuts to


remove plastic cover

 Remove plastic cover from main-


board

HAMM AG 4/10 # 2138392


30.11.2009
Series 3000

 Mainboard with diagnose LED


and pushbutton

2.2 Readout of Blink-Codes

9 Ignition on!

8 Diesel engine switched off!!!

The blink code will appear in three flashing sequences with short breaks in
between.

9 Example:
flashing sequence = blink code
D_DD_DDD = 1-2-3

 Switch ignition on!

HAMM AG 5/10 # 2138392


30.11.2009
Series 3000

 Localize pushbutton and LED for


the readout of the EMR3 error
memory.

 Apply pushbutton until red LED


glows
 Release pushbutton and wait for
the blink code

 The blink code will appear. Example:


Please pay attention, count the flashing sequence = blink code
flashes and write down the error
codes D_DD_DDD = 1-2-3

 Apply pushbutton only for a short


click to go to the next error (if pre-
sent)

HAMM AG 6/10 # 2138392


30.11.2009
Series HD

3. Series HD
3.1 Preparations

8 Ignition switched off!

 Open switchbox (cabin floor right


side)

 Loosen two allen screws

HAMM AG 7/10 # 2138392


30.11.2009
Series HD

 Remove cover

 Mainboard with diagnose LED


and pushbutton

3.2 Readout of Blink-Codes

9 Ignition on!

8 Diesel engine switched off!!!

The blink code will appear in three flashing sequences with short breaks in
between.

9 Example:
flashing sequence = blink code
D_DD_DDD = 1-2-3

HAMM AG 8/10 # 2138392


30.11.2009
Series HD

 Switch ignition on!

 Localize pushbutton and LED for the


readout of the EMR3 error memory.

 Apply pushbutton until red LED glows


 Release pushbutton and wait for the
blink code

Beispiel:
 The blink code will appear. Please
pay attention, count the flashes and Blinksequenz = Blink-Code
write down the error codes D_DD_DDD = 1-2-3

 Apply pushbutton only for a short


click to go to the next error (if pre-
sent)

HAMM AG 9/10 # 2138392


30.11.2009
Notes

Notes

HAMM AG 10/10 # 2138392


30.11.2009

You might also like