You are on page 1of 9

5/29/2022

DATE

1:33:07
EXISTING SITE PLAN NEW SITE PLAN

AM
60' 60'

Construction drawings.
5' UTILITY ESMT. 5' UTILITY ESMT.

DESCRIPTION
FND CAP

FND CAP
ON CONC.
STORAGE

#13979

#13979
ADDITION /
GARAGE /

GARAGE /
STORAGE

STORAGE
33' - 5"

ADU

MARK
12' - 5"

A101
SHEET NO.
1' 1'

135'

135'
135'

135'
40.2' 40.2'

14.1' 14.1'

RESIDENCE RESIDENCE
31.6'

31.6'
34.6'

34.6'
5.7' 5.7'
17.4' 17.4'
12.3' 12.3'
10.5' 10.5'
RETAINING

RETAINING

1612 VASSAR DR. SE


25.0'

25.0'

ALBUQUERQUE NM
WALL

WALL

COLIN SLEEPER

87106, USA.
CURBLINE CURBLINE
FND 'X' FND 'X'
ON CURB FND 'X' ON CURB FND 'X'
1
OLD SITE PLAN
1612 VASSAR DR. SE ON CURB
2
NEW SITE PLAN
1612 VASSAR DR. SE ON CURB
1/8" = 1'-0"
50' R.O.W. 1/8" = 1'-0"
50' R.O.W.
12' - 1 1/2"

2' - 7"
2' - 7"

7' - 4"
7' - 4"

9' - 8 1/2"
9' - 8 1/2"

12' - 1 1/2"

COLIN SLEEPER
1612 VASSAR DR. SE
SHEET NO. MARK DESCRIPTION DATE
ALBUQUERQUE NM Construction drawings. 5/29/2022
87106, USA. 1:33:07
A102 AM
12' - 1 1/2"

2' - 7"
2' - 7"

7' - 4"
7' - 4"

9' - 8 1/2"
9' - 8 1/2"
8' - 9 1/2"

12' - 0"

5' - 0"
2' - 10 1/4"

12' - 1 1/2"

COLIN SLEEPER
1612 VASSAR DR. SE
SHEET NO. MARK DESCRIPTION DATE
ALBUQUERQUE NM Construction drawings. 5/29/2022
87106, USA. 1:33:07
A103 AM
5' - 0"

5' - 10"
2' - 11"

9' - 9 1/2" 7' - 0"

3' - 6" 3' - 0"


3' - 0"

8' - 8"
1. Ground Floor
2. Ground Ceiling
3. Top

0' - 0"
8' - 8"
9' - 9 1/2"

8' - 8" 1' - 1 1/2"


1. Ground Floor
2. Ground Ceiling
3. Top

0' - 0"
8' - 8"
9' - 9 1/2"

COLIN SLEEPER
1612 VASSAR DR. SE MARK DESCRIPTION DATE
SHEET NO.
ALBUQUERQUE NM Construction drawings. 5/29/2022
1:33:08
87106, USA. A104 AM
2' - 11"

5' - 0"

8' - 8" 1' - 1 1/2"


1. Ground Floor
2. Ground Ceiling
3. Top

0' - 0"
8' - 8"
9' - 9 1/2"

8' - 8" 1' - 1 1/2"


1. Ground Floor
2. Ground Ceiling
3. Top

0' - 0"
8' - 8"
9' - 9 1/2"

COLIN SLEEPER
1612 VASSAR DR. SE MARK DESCRIPTION DATE
SHEET NO.
ALBUQUERQUE NM Construction drawings. 5/29/2022
1:33:08
87106, USA. A105 AM
5/29/2022
DATE

1:33:08
AM
2' - 7" 7' - 4" 9' - 8 1/2" 8' - 9 1/2"

CIRCUIT BOARD
EXHAUST

Construction drawings.
FAN/VENT

DESCRIPTION
5' - 0"
GFI

GFI
12' - 1 1/2"

MARK
SD

A106
SHEET NO.
SD

GFI GFI GFI GFI

2' - 7" 7' - 4" 9' - 8 1/2" 12' - 0"

ELECTRICAL NOTES
SYMBOL DESCRIPTION
1. THE FOLLOWING NOTES APPLY TO THE ELECTRICAL CONTRACTOR. PROVIDE ALL
LABOR AND MATERIAL FOR ELECTRICAL ROUGH-INS.
2. ALL ELECTRICAL WORK SHALL CONFORM TO ALL STATE AND LOCAL CODES.
CEILING LIGHTS
3. PROVIDE ALL JUNCTION BOXES, RECEPTACLES, SWITCHES, DISCONNECT
SWITCHES, ETC., AND MAKE ALL ELECTRICAL CONNECTIONS TO FOOD SERVICE WALL LIGHTS

1612 VASSAR DR. SE


EQUIPMENT.

ALBUQUERQUE NM
4. INTERCONNECT ALL CONTROL SWITCHES AS REQUIRED FOR EQUIPMENT SHOWN
AND ALL OTHER COMPONENTS WHICH COME AS PART OF ANY EQUIPMENT SHOWN. 220V DUPLEX RECEPTACLE OUTLET

COLIN SLEEPER
5. INTERWIRE JUNCTION BOX WITH OUTLET ABOVE HOODS.
GFI
6. REFER TO ELECTRICAL DRAWINGS FOR GENERAL USE CONVENIENCE OUTLETS
NOT SHOWN.
220V GFI RECEPTACLE OUTLET

87106, USA.
7. BRANCH STUB-UPS TO ALL ELECTRICAL CONNECTIONS FOR EQUIPMENT
(EQUIPMENT TERMINAL BLOCK OR RECEPTACLE) SD SMOKE DETECTORS
8. BRANCH STUB-UPS TO ALL ELECTRICAL CONNECTIONS FOR EQUIPMENT
(EQUIPMENT TERMINAL BLOCK OR RECEPTACLE).
9. DETERMINE THE ELECTRICAL REQUIREMENTS FOR EQUIPMENT MARKED
"EXISTING", "BY OWNER" & "BY OTHERS" IN THE EQUIPMENT LIST.
5/29/2022
DATE

1:33:08
WATER CONNECTED TO MAIN HOUSE

AM
BOILER

Construction drawings.
5' - 0"

DESCRIPTION
MARK

A107
SHEET NO.
GENERAL PLUMBING REQUIREMENTS: STRUCTURE.
1. UNLESS OTHERWISE NOTED, THE WORK DESCRIBED ON THE PLANS 7. NO DOMESTIC WATER, HEATING WATER OR CONDENSER WATER
AND SPECIFICATIONS SHALL INCLUDE THE FURNISHING AND INSTALLATION LINES SHALL BE LOCATED EXPOSED IN FINISHED SPACES OR BELOW THE
OF ALL LABOR AND MATERIALS NECESSARY FOR COMPLETE AND BUILDING SLAB UNLESS SHOWN OTHERWISE ON THE DRAWINGS.
OPERATIONAL HVAC AND PLUMBING SYSTEMS. CONTRACTOR SHALL 8. NO GAS LINES SHALL BE LOCATED BELOW BUILDING SLAB.
FURNISH THESE EVEN IF ITEMS REQUIRED TO ACHIEVE THIS (I.E. OFFSETS, (A) PIPE INSTALLATION:
ISOLATION AND BALANCING DEVICES, MAINTENANCE CLEARANCES, ETC.) (1) ALL PIPING SHALL BE ADEQUATELY SUPPORTED FROM THE
LEGENDS ARE NOT SPECIFICALLY SHOWN. BUILDING STRUCTURE TO PREVENT SAGGING, POCKETING, SWAYING OR
2. DATA GIVEN ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. DISPLACEMENT BY MEANS OF HANGERS AND SUPPORTS. PIPING IS NOT TO
ABSOLUTE ACCURACY IS NOT GUARANTEED AND THE CONTRACTOR SHALL BE SUPPORTED BY EQUIPMENT.
OBTAIN AND VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE (2) PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR MATERIALS.
SYMBOL DESCRIPTION REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES, ETC. AT THE (3) PROVIDE MANUAL AIR VENTS AND CAPPED HOSE-END DRAINS WITH
SITE AND SHALL SATISFACTORILY ADAPT HIS WORK TO ACTUAL CONDITIONS ISOLATION VALVE AT PIPING HIGH AND LOW POINTS.
AT THE BUILDINGS. THE DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND (4) WELD PIPE IN ACCORDANCE WITH APPLICABLE CODES AND
DOMESTIC COLD WATER SHALL NOT BE SCALED. HOWEVER, THIS DOES NOT RELIEVE ANY STANDARDS. WELDERS SHALL BE CERTIFIED FOR TYPE OF WELD BEING
SUBCONTRACTOR FROM COORDINATING HIS WORK WITH ALL OTHER TRADES PERFORMED.
AND FROM ADJUSTING HIS WORK AS REQUIRED BY THE ACTUAL CONDITIONS (5) FLUSH OUT PIPING AND REMOVE CONTROL DEVICES BEFORE
OF THE PROJECT. THE CONTRACTOR SHALL VISIT THE SITE BEFORE PERFORMING PRESSURE TEST. DO NOT USE PIPING SYSTEM VALVES TO

1612 VASSAR DR. SE


ALBUQUERQUE NM
SUBMITTING A BID TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL ISOLATE SECTIONS WHERE TEST PRESSURE EXCEEDS VALVE PRESSURE
DOMESTIC HOT WATER CONDITIONS OF THE PROJECT. RATING. PRESSURIZE PIPING AT 100 PSIG. IF LEAKAGE IS OBSERVED OR IF
3. COORDINATE AND ADJUST ALL WORK BETWEEN TRADES AND TEMPERATURE COMPENSATED PRESSURE DROP EXCEEDS 1% OF TEST

COLIN SLEEPER
EXISTING CONDITIONS IN ORDER TO ACCOMPLISH A NEAT, INTEGRATED AND PRESSURE, REPAIR LEAKS AND RETEST. DO NOT USE AIR PRESSURE TO TEST
EFFICIENT INSTALLATION. EXAMINE THE CONTRACT DOCUMENTS OF ALL PLASTIC PIPE.
SANITARY PIPE TRADES (I.E. THE ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL (6) PROVIDE SUPPORT UNDER ELBOWS ON PUMP SUCTION AND
LIGHTING PLAN, ETC.). COORDINATE NECESSARY EQUIPMENT, DUCTWORK DISCHARGE LINES.

87106, USA.
AND PIPING LOCATIONS SO THAT THE FINAL INSTALLATION IS COMPATIBLE (7) ALL STRAINERS SHALL BE FURNISHED WITH A "ROUGHING" SCREEN
WITH THE MATERIALS AND EQUIPMENT OF THE OTHER TRADES. PREPARE AND TWO (2) SCREENS FOR NORMAL OPERATION. INSTALL STRAINER WITH
SHOP DRAWINGS FOR INSTALLATION OF ALL NEW WORK BEFORE ROUGHING SCREEN AND OPERATE SYSTEM FOR 24 HOURS MINIMUM (RUN
INSTALLATION TO VERIFY COORDINATION OF WORK BETWEEN TRADES. DOMESTIC WATER SYSTEMS AT MAX FLOW FOR A MINIMUM OF ONE HALF (1/2)
4. ALL CAPACITIES ARE SCHEDULED AT JOBSITE ALTITUDE OF 6500 FT. HOUR. REMOVE ROUGHING SCREEN AND INSTALL NORMAL SCREEN, AFTER
5. VERIFY THE ELECTRICAL SERVICE PROVIDED BY THE ELECTRICAL TWO WEEKS OF NORMAL OPERATION INSTALL NEW NORMAL SCREEN.
CONTRACTOR BEFORE ORDERING ANY MECHANICAL EQUIPMENT REQUIRING
ELECTRICAL CONNECTIONS.
6. SUSPEND EACH TRADE'S WORK SEPARATELY FROM THE
CT.
5/29/2022
DATE

1:33:09
AM
HVAC PLAN
Construction drawings.
DESCRIPTION
4"

MARK

A108
SHEET NO.
4" 4" 4"

HVAC NOTES
1. SUPPLY FAN INTERNAL STATIC PRESSURE IS TO INCLUDE AN ALLOWANCE OF 0.3" WG., PD FOR FILTER LOADING NOT INCLUDED IN THE
SUPPLY ESP. THE DIRTY FILTER PRESSURE DROP IS CONSIDERED TO BE A UNIT LOAD.
2. THE SUPPLY FAN MOTOR WILL BE CONTROLLED USING AN ELECTRONICALLY COMMUTED MOTOR (ECM) CONTROLLER AND SHALL RAMP
THE MOTOR RPM UP OR DOWN AS REQUIRED TO MAINTAIN A CONSTANT DISCHARGE STATIC PRESSURE AS FILTERS LOAD.
3. GENERAL: PROVIDE EACH UNIT WITH A 14" HIGH ROOF CURB, COMPLETE WITH INSULATION, WOOD NAILER AND 1/2" THICK COMPRESSION
GASKET ON TOP EDGE OF CURB TO SEAL VOIDS AND PROVIDE MORE UNIFORM LOADING. 200 LBS CURB WEIGHT IS INCLUDED IN LISTED

1612 VASSAR DR. SE


ALBUQUERQUE NM
MAXIMUM UNIT WEIGHT.
4. GENERAL: OUTDOOR AIR SUMMER DESIGN CONDITIONS ARE BASED ON 98.0ºF DB/77.3ºF WB; SUPPLY AIR DEWPOINT SHALL BE 55°F OR
LOWER. WINTER DESIGN CONDITIONS ARE BASED ON 2.3º F DB / 2.2° F WB.

COLIN SLEEPER
5. MAXIMUM FILTER FACE VELOCITY NOT TO EXCEED 400 FPM.
6. MANUFACTURER TO PROVIDE SINGLE POINT POWER CONNECTION AND INTEGRAL NON-FUSED DISCONNECT SIZED PER NEC. UNIT WILL BE
PROVIDE WITH UNIT MOUNTED 120V/1P RECEPTACLE POWERED BY UNIT SINGLE POINT CONNECTION.

87106, USA.
7. PROVIDE STAND ALONE CONTROLLER WITH CONNECTION BACK TO VRF CENTRAL CONTROLER WITH PASS THOUGH OF POINTS TO DDC
SYSTEM FOR ALARM MONITORING.
8. UNITS SHALL HAVE MINIMUM 10:1 MODULATING GAS HEATER TURNDOWN.
9. PROVIDE MERV 8 PREFILTERS UPSTREAM OF THE EACH SIDE OF THE ENERGY RECOVERY WHEEL AND MERV 8 FINAL FILTERS UPSTREAM
OF THE COOLING COIL.
10. PROVIDE DOA-1 WITH A SMOKE DETECTOR AT THE EXHAUST BACK TO UNIT FROM THE BUILDING.
5/29/2022
DATE

1:33:09
GENERAL NOTES INSULATION EXTERIOR ENVELOPE

AM
1. THESE DRAWINGS INDICATE IN GENERAL THE PROJECT IN TERMS OF 1. FOR EXTERIOR WALL INSULATION PROVIDE RIGID, NON-COMBUSTIBLE EXTRUDED POLYSTYRENE 1. THE EXTERIOR WALL AS SHOWN SHALL BE COMPLETE SYSTEM INCLUDING ALL
ARCHITECTURAL DESIGN INTENT, THE DIMENSIONS OF THE BUILDING, THE MAJOR WITH WATER REPELLANT COATING ON INNER SIDE. THE INSULATION SHALL PROVIDE "U" VALUE HOT DIPPED GALVANISED STEEL SUPPORTS, STIFFENERS, FASTENERS, SEALANT,
ARCHITECTURAL ELEMENTS AND TYPE OF STRUCTURAL,MECHANICAL AND AS/SPECS. JOINERY, MISC, PIECES, AND MATERIAL THICKNESS AS REQUIRED TO FORM HIGH
ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT NECESSARILY INDICATE OR QUALITY SYSTEM IN ACCORDANCE WITH THE SPECIFICATIONS AND THE PROFILES
DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF 2. ALL INSULATION PANELS TO BE OVERSIZED TO CREATE A TIGHT JOINT BETWEEN PANELS. ALL SHOWN.
THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. AS INDICATED OR JOINTS AND EXPOSED EDGES TO BE FOIL TAPED.

Construction drawings.
DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE 2. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE
PROPER EXECUTION AND COMPLETION OF THE WORK. 3. PROVIDE INSULATION AT ALL CONNECTION AND JOINTS TO MAINTAIN A CONSTANT U FACTOR. SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED,

DESCRIPTION
2. THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL FLOOR/WALL CONSULT THE ENGINEER BEFORE PROCEEDING WITH WORK.
SLEEVES AND SHAFTS IN CONCRETE SLABS/WALLS WITH MECHANICAL, 4. ALL INTERIOR INSULATION TO UNDERSIDE OF SLABS AND TO INSIDE SURFACE OF EXTERNAL
PLUMBING, FIRE PROTECTION, ELECTRICAL, STRUCTURAL AND ARCHITECTURAL WALLS SHALL BE SEMI RIGID (FIBRE GLASS WOOL) BOARDS. 3. ALL DETAILS ARE TO BE COORDINATED WITH THE STRUCTURAL FRAMING,
DRAWINGS AND DISCREPANCIES, IF ANY, TO BE BROUGHT TO NOTICE OF THE INTERIOR FINISHES AND OTHER RELATED BUILDING COMPONENTS IN ORDER TO

NOTES
ENGINEER PRIOR TO EXECUTION OF WORK. INSULATION TABLE PROVIDE A COMPLETE ENCLOSURE OF FINISH MATERIALS.
3. THE CONTRACTOR SHALL CONDUCT HIS OWN SITE SURVEY OF THE EXISTING WALL AND ROOF ASSEMBLY MAXIMUM U-VALUE:
GROUND AND CURB ELEVATIONS (LEVELS) AND REPORT ACTUAL ELEVATIONS 4. THE ANCHORAGE ANGLES, SHAPES AND DETAILS ARE SUGGESTIVE AND ARE
(LEVELS) TO THE ENGINEER. THE THERMAL INSULATION MATERIAL USED IN THE BUILDING EXTERNAL WALL / ROOF MUST NOT TO BE ENGINEERED AND DETAILED AS REQUIRED. THE CONTRACTOR IS TO
4. CONTRACTOR'S SHOP DRAWINGS SHOULD INDICATE ACTUAL ELEVATIONS EXCEED THE FOLLOWING VALUE: COORDINATE ALL ANCHORAGE DETAILS WITH APPROPRIATE TRADES.
(LEVELS).
5. ALL ELEVATIONS (LEVELS) ARE IN METERS. ROOF: 0.437 W/m² °C (0.077 BTU/h ft² °F) 5. ALL FASTENERS ARE TO BE CONCEALED, EXCEPT AS SPECIFICALLY SHOWN.
6. ALL DIMENSIONS ARE IN MM AND ANGLES IN DEGREES UNLESS OTHERWISE ALL BUTT JOINTS ARE TO HAVE CONCEALED BACK-UP ROD WITH CAPTIVE
NOTED. EXTERNAL WALL: 0.568 W/m² °C (0.100 BTU/h ft² °F) SEALANT.

MARK
7. ONLY WRITTEN DIMENSIONS IN ALL CASES SHALL BE FOLLOWED.
8. ALL EXISTING OR PROPOSED ELEVATIONS (LEVELS) AND DIMENSIONS, ON SITE WINDOW REQUIREMENTS 6. ATTACHMENT AND DETAILS FOR THE EXTERIOR WALL AND EXTERIOR GLASS
AND ON DRAWINGS MUST BE CHECKED AND VERIFIED BY THE CONTRACTOR WINDOW WALL RATIO MAXIMUM U-VALUE MAXIMUM SHADING SYSTEMS ARE SHOWN SCHEMATICALLY AND TOGETHER WITH THE
BEFORE THE PREPARATION OF SHOP DRAWINGS OR COMMENCEMENT OF ANY (WWR) W/m² °C (BTU/ft²h °F COEFFICIENT (SC) SPECIFICATIONS AND THE PROFILES SHOWN ARE INTENDED TO ESTABLISH
ITEM OF WORK ON THE SITE. PERFORMANCE AND MATERIAL QUALITIES DESIRED. THE CONTRACTOR SHALL BE

A109
SHEET NO.
9. ARCHITECTURAL DRAWINGS MUST ALWAYS BE READ IN CONJUNCTION WITH 5-40% 3.30 (0.58) 0.4000 RESPONSIBLE FOR THE DEVELOPMENT OF FINAL EXTERIOR WALL DETAILS TO
ALL OTHER RELEVANT SERVICES DRAWINGS AND CONTRACT DOCUMENTS. ANY ABOVE 40% 1.90 (0.33) 0.3500 ACCOMMODATE THE FABRICATION, ERECTION AND INSTALLATION OF THE WORK
DISCREPANCY BETWEEN THESE DRAWINGSAND DOCUMENTS SHOULD BE IN ACCORDANCE WITH THE DESIGN INTENT SHOWN.
REPORTED TO THE ENGINEER FOR CLARIFICATION AND VERIFICATION.
10. ALL ALUMINUM TRIMS SHALL BE POWDER COATED FINISH. 7. SEALANT DRAINAGE SYSTEM GASKETS AND WATERPROOFING MEMBRANE
11. ALL PLASTERED SURFACES SHALL BE PAINTED. SHALL BE ASSEMBLED IN SUCH A MANNER TO PROVIDE A HIGH QUALITY
12. ALL WALL FINISHES OR CEMENT PLASTERING WORKS ARE TO BE EXTENDED 10 WEATHERPROOF BUILDING ENCLOSURE.
CM. ABOVE SUSPENDED CEILING LEVEL (ELEVATION) OR AS INDICATED.
13. ALL UNDIMENSIONED WALL SHOULDERS SHALL BE 100MM WIDE 8. ALL PROPOSED DETAILS FOR EACH TYPE OF GLAZING ARE TO BE SUBMITTED TO
14. REFER SCHEDULE OF WALL TYPES FOR DIFFERENT WALL SITUATIONS. THE ENGINEER FOR REVIEW.
15. ALL BLOCKWALLS ENCLOSING THE FIRE ZONES SHALL BE LIGHT WEIGHT METAL WORKS
CONCRETE BLOCKWALL AND EXTENDED UP TO THE SOFFIT OF THE SLAB TO 9. COLOR OF SEALANT SHALL MATCH ADJACENT MATERIALS OR AS SPECIFIED BY
PROVIDE 2 HRS FIRE RATING. .1. ALL MILD STEEL WORKS (I.E. RAILS,ANGLES ETC.) SHOWN ON THE CONTRACT DRAWINGS/DETAILS SHALL THE ENGINEER.
16. ALL SHAFT WALLS TO PROVIDE FOR 2 HRS. FIRE RATING. BE PRIMED AND SHALL BE PAINTED WITH TWO COATS OF EPOXY PAINT.
17. ALL SHAFTS SHALL BE SEALED AT BOTTOM & TOP TO PROVIDE 2 HRS. FIRE 10. COORDINATE LOCATION OF EXTERIOR WALL ANCHORS, SEALANT POSITIONS
RATING. 2. STEEL ELEMENTS NOT SHOWN IN THE CONTRACT DRAWINGS, BUT ARE DEEMED NECCESSARY FOR THE WITH ADJACENT WORK INCLUDING MATERIALS AND OTHER CONTIGUOUS
18. ALL FIRE DOORS SHALL HAVE SMOKE SEAL INTEGRAL WITH IT. SATISFACTORY COMPLETION OF THE WORKS SHALL BE GALVANISED STEEL PRIMED & PAINTED WITH TWO SEALANTS.
19. ALL PLUMBING H.V.A.C. OPENINGS IN FIRE RATED WALLS & SLABS SHALL BE COATS OF EPOXY PAINT FOR ALL INTERIOR SITUATIONS AND STAINLESS STEEL (#316) FOR ALL EXTERIOR
PROVIDED WITH FIRE SMOKE SEALS OF THE SAME FIRE RATING AS OF THE WALLS SITUATIONS. 11. THE DESIGN OF THE EXTERIOR WALL IS TO TAKE INTO CONSIDERATION
& SLABS THEY PENETRATE THROUGH. BUILDING MOVEMENTS DUE TO WIND LOADS, THERMAL EXPANSION AND
20. CONTRACTOR TO LOCATE ALL ACCESS PANEL IN THE GYPSUM BOARD CEILING 3. ALL WELDED STEEL JOINT SHALL BE GRINDED SMOOTH, PRIMED & PAINTED. CONTRACTION, FLOOR DEFLECTIONS, SHRINKAGE, CREEP AND SIMILAR
FOR SERVICES ACCESS. MOVEMENTS.
21. FOR AREAS WITHOUT SUSPENDED CEILING HAVING EXPOSED SLAB AND 4. ALL WELDING SHALL BE OF SUITABLE TYPE TO STEEL WORKS.
BEAMS, WALL FINISH MATERIAL SHALL BE FROM FLOOR LEVEL TO BOTTOM OF 12. DESIGN, FABRICATE AND INSTALL COMPONENT PARTS SO THAT THE
SLAB LEVEL. (UNLESS NOTED OTHERWISE) 5. PROVIDE 125X125 SILL ANGLE SUPPORT, PIT LADDER & HOISTING HOOK FOR 300KG SUSPENDED LOAD IN COMPLETED EXTERIOR WALL ASSEMBLY INCLUDING GLASS AND STONE
22. THE CONTRACTOR SHALL SUBMIT SAMPLES AND SHOP DRAWINGS FOR ALL MACHINE ROOM. CLADDING WILL WITHSTAND THE INWARD AND OUTWARD WIND SPEED OF 140
WORKS WITH ALL NECESSARY DETAILS AND DESIGN INFORMATION FOR KM/HOUR
APPROVAL. 6. LOCATION OF CATWALK IN THESE DOCUMENTS ARE SUGGESTED POSITIONS. FINAL LOCATIONS ARE TO BE
23. NOTES APPEARING ON VARIOUS DRAWINGS FOR DIFFERENT SYSTEMS AND CO-ORDINATED WITH THE INTERIOR DESIGN SUSPENDED CEILING PROFILES. 13. PROVIDE ALLOWANCE FOR EXPANSION AND CONTROL JOINTS WHERE SHOWN
MATERIALS ARE TO BE REVIEWED, COORDINATED AND ARE TO BE APPLIED TO AND AS REQUIRED. LOCATION OF ALL JOINTS SHALL BE REVIEWED WITH THE
ALL RELATED DRAWINGS AND DETAILS. ENGINEER.
B. CONCRETE MASONRY WALL (BLOCK WALL)
1. PROVIDE CONTROL JOINT AT: 14. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH
9000 MM SPACING AT LONG STRAIGHT WALLS, OTHER AS REQUIRED TO PREVENT MOLECULAR BREAKDOWN.

1612 VASSAR DR. SE


ALBUQUERQUE NM
AT MAJOR CHANGES IN WALL HEIGHTS,
AT CHANGES IN WALL THICKNESS, 15. ALL ALUMINUM DOOR/WINDOW FRAMES, LOUVERS, SHALL BE FINISED AS PER
ABOVE JOINTS IN FOUNDATIONS, DOOR, WINDOW, LOUVER SCHEDULE. REFER DRAWINGS OF SERIES AD.500,

COLIN SLEEPER
AT COLUMNS AND PILASTERS, AD.600 & AD.700.
AT ONE OR BOTH SIDES OF WALL OPENINGS AND AT WALL INTERSECTIONS.
ALL CONTROL JOINTS SHOULD CONTINUE ALL THROUGH VERTICALLY. EXTERIOR SOFFIT
ALL CONTROL JOINTS ARE TO BE FILLED WITH APPROVED COMPRESSIBLE FILLER

87106, USA.
AND 1. ALL EXTERIOR SOFFITS BELOW AIR-CONDITIONED SPACES SHALL HAVE A MINIMUM 75 MM THICK
ALL EXPOSED SURFACES TO BE SEALED WITH APPROVED SEALANT AND BACK- INSULATION (SEMI-RIGID INSULATION ATTACHED DIRECTLY TO STRUCTURAL SOFFIT & LINED WITH GYPSUM
UP ROD. BOARD) TO PROVIDE REQUIRED "U" VALUE.
2. REFER SCHEDULE OF WALL TYPES FOR DIFFERENT WALL SITUATIONS.
3. ALL BLOCKWALLS ENCLOSING THE FIRE ZONES SHALL BE LIGHT WEIGHT 2. ALL STONE PIECES FOR SOFFITS SHALL BE MECHANICALLY HUNG.
CONCRETE BLOCKWALL AND EXTENDED UP TO THE SOFFIT OF THE SLAB TO
PROVIDE SPECIFIED FIRE RATING 3. THE CONTRACTOR SHALL ENGINEER STONE SOFFITS STEEL BACK-UP STRUCTURE WITH STAINLESS STEEL
4. ALL BLOCKWALLS INDICATED ON PLAN ARE TO EXTEND TO THE SOFFIT OF THE (#316) STRUCTURAL SECTIONS, TO WITHSTAND WIND SPEED OF 140KM/HR. AND SELF-LOAD OF STONE. IN
SLAB, EXCEPT INTERNAL TOILET PARTITION, INTERNAL KITCHEN PARTITION, ADDITION, BACK-UP SYSTEM AND STONE FIXING DEVICES SHALL BE DESIGNED TO AVOID SOFFITS SAGGING,
INTERNAL OFFICE PARTITIONS AND SMALL SPACES SUCH AS STORES. BREAKAGE, CRACKS ETC.. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL.

You might also like