You are on page 1of 235

/

woobs
AIR MOVEMENT

JM Aerofoil 50 Hz
Performance and Specification Details
Long & Short Cased Axial Fans
For Ducted Applications
JMAEROFOIL
CONTENTS
woos’1
AIR MOVEMENT

Page:

JM Aerofoil - Introduction 4 5 -

Specification 6 7 -

Quality Systems 8

HowTo Specify 9

Guide To Fan Selection - Total Pressure 10-11


Static Pressure 12 13 -

Motor Frame Size Schedules - Single Phase Single Speed 15 17


- -

Three Phase Single Speed 18 -30


-

Three Phase -Two Speed 31 -60

Performance Curves SKi 1685-


SK11865

Dimensions and Weights 61 - 66

Ancillaries 67 68 -

Useful Information 69

3
JM AEROFOIL INTRODUCTION -

Air movement technology is a world of In fact Woods products are marketed and
specialised knowledge and one in which Woods installed in over 100 countries, with applications
Air Movement Limited are not just the specialists ranging from the world’s largest engineering
but the acknowledged leaders. Woods extensive projects to the smallest poultry houses.
knowledge of designs and applications extends Whatever the product size or cost it is Woods
back over 90 years of experience as one of the policy to provide the highest quality at
world’s largest manufacturers of fans and air competitive prices, all backed by dedicated staff,
moving equipment. fully trained to provide customer satisfaction.

Based in Colchester, in the U.K., Woods have Woods Air Movement Limited is a BS EN ISO
extensive laboratories that constantly develop 9001 :94 Registered Company.
new concepts and product ranges, enabling the
company to maintain its market leadership. In In line with the Company’s strict adherence to
addition Woods have three sales centres in the the highest quality assurance standards, regular
U.K. together with subsidiary companies in Italy, quality audits occur ensuring that the Woods JM
Germany, Finland, France, Singapore and the Aerofoil consistently meet the catalogue
U.S.A. plus, a network of fully trained local staff specifications, now independently endorsed by
in 70 different countries with intimate knowledge the Air Movement and Control Association
of local needs. International (AMCA).

WOODI
AIR MOVEMENT
All Aluminium Precision Die-Cast
Impeller
A unique high efficiency aerofoil section blade
within a purposely smoothed hub and clamp- Fixings
plate for adjustable pitch angle flexibility. The All fixings are protected with an organically
Woods impellers are all precision die-cast to offer based zinc coating to provide excellent
thin aerofoil sections for low generation of noise corrosion resistance.
levels. Every cast aluminium component is X
rayed using Real Time Radiography inspection
prior to assembly. This feature can provide
evidence of casting quality against product liability
legislation if
specified.

Arms
Mounting arms are specially designed to offer
“V’ Slot /Pad Mounted Fan Motors minimal resistance to airflow.These arms are
All Woods JM range of fans incorporate an carefully spaced away from the impeller to
electrical power drive specifically designed to minimise noise generation.
optimise fan performance, and minimise the The arms also improve the cooling of the motor,
obstruction to airflow. hence increasing motor performance and life.
Totally enclosed, pad mounted design to All arms are hot dipped galvanised after
designation lP55, Class F insulation as standard. manufacture for maximum resistance to
Directly coupled to the fan impeller to minimise
drive losses. Overheat protection is included on
single phase machines and available on others.

Casings
Available in either a long cased form complete
with an externally mounted pre-wired electrical
terminal box, or short cased for duct or plate
Testing
installation. Casings are spun from sheet
Performance data has been obtained in
steel with integral pre-drilled flanges, fully
accordance with the internationally recognised
welded seams and hot-dipped galvanised after
standard ISO58O1 :1997 installation category D
manufacture for excellent durability.
-

(AMCA approved) for aerodynamic performance


and BS 848 Part 2 (1985) for acoustic
performance.

5 WOODS
AIR MOVEMENT
JM AEROFOIL
wooisI
AIR MOVEMENT

SPECIFICATION
Motors performance and minimise the generation of
noise. The thin sections obtained by precision
Constructed from aluminium up to frame size die cast manufacturing techniques help promote
D160, cast iron above as standard with special these particular features whilst also allowing a
“T” slot or pad mounted fixings. lighter weight assembly to be produced.
Suitable for horizontal through to vertical shaft Precision die cast aluminium hub and clamp-
operation. plate, with equally spaced, fully adjustable, high
Supplied 1P55, with removable drain plugs. pressure die cast aerof oil section blades.
Bearings lubricated with wide temperature range All rotating aluminium components are X-ray
grease, sealed for life. examined prior to machining to assure quality.
Continuous operating range -40° C to +50° C, Balanced to BS6861 Part 1 1987 (ISO 1940-
minimum starting temperature -20°C(for other 1986) Grade G6.3. Corrosion resistant and
operating temperatures please enquire). suitable for continuous outside use from -40°C to
Insulation class F as standard. +50°C, (for other operating temperatures please
2 speed operation by Delta/Star(A/A) enquire).
reconnection available on most three phase
motor up to frame size F22. Non-overloading
Integral pre-wired capacitor on most single phase JM Aerofoil fans have a non-overloading
fans. characteristic; the peak power input occurs within
Ratings comply with BS5000 Part 99 and IEC 34-1. the range of normal operating pressures and is
Two speed motors available always exceeded by the motor rating.
Pole Change (PC) or Dahlander Ancillaries
Two speeds can be obtained by reconnecting a single
Motor and Impeller side guards to comply with
winding via six winding terminals to give two separate
BS848 Pt 5., and draft ISO standard.
pole numbers.
Choice of auto-transformer or electronic speed
Dual Wound
controllers.
Thistypeofmotorhastwoseparate individual windings
2 speed switch for Delta/Star (s/A) reconnection,
of the requisite poles to give the speeds required.
Silencers.
Electrical Supply Mounting Feet for both horizontal or vertical
220-240 V 50 Hz single phase (1(p) operation.
Matching Flanges, Flexible Connectors.
380-420 V 50 Hz three phase (3(p)
(60 Hz variants and other voltages are available Air Operated Dampers for horizontal or vertical 0
on request). up operation. Bellmouth inlets. Vibration Isolators.
Speed control can be provided by Woods Air Control gear complete with BMS contacts
Movement’s range of electronic and auto available on request.
transformertype speed controllers. Speed control Finish
details are based on the adoption of the more Fan casings, motor mounting arms, mounting
usual and technically superior three-wire circuit. feet, matching flanges and guards are all hot
Referto Colchester if two wire control is required. dipped galvanised after manufacture, (in
The single phase controller rating may be less accordance with BS EN ISO 1461:1999).
than the full load current, as only the “U” phase Motors, aluminium self finish,or painted to motor
voltage is varied. manufacturers specification.
Many of the regulatable, three phase motors
may be offered for2 speed applications by Delta!
Star (\/A) reconnection.
Impellers
JM Aerofoil impellers have a unique aerodynamic
section blade to optimise the efficiency of

6
JM AEROFOIL
C’ SPECIFICATION
Reversal of Airflow A further factor that must be considered in
assessing the life of the impeller is the quality of
Woods Air Movement has developed the JM the casting. Extensive testing of the alloys we
Aerofoil to give the optimum aerodynamic and use has established relationships between life,
acoustic performance. To optimise the perform operational stresses, and casting quality.
ance Woods Air Movement used the latest de Therefore to further ensure reliable operation of
sign software to establish the blade shape and our impellers all alloy impeller castings are
in particular the aerodynamic blade sections. assessed using x-ray against rigorous
The results of laboratory testing demonstrated acceptance criteria.
world class aerodynamic and acoustic perform
ance that is AMCA approved. Since the stresses experienced in the reverse
mode are generally higher than those in forward
As part of our commitment to fan engineering operation some impeller configurations are not
and total quality Woods Air Movement have es suitable for applications that require continuous
tablished the operational limits of the impellers or regular reverse operation. Where this is the
? case we have highlighted the fact on each
in all circumstances. Under laboratory conditions
relevant performance chart within this catalogue.
Woods Air Movement have tested JM impellers If these fans are required to be operated in
when run forwards, and in reverse. By measur reverse in other than cases of emergency, then
ing the stresses on the impellers under these each instance should be referred to Colchester
conditions, and relating these stresses to the for qualification or re-selection of impeller type.
properties of the alloys used for impeller con
struction, it is possible to determine the All other impeller configurations can be safely
maximum speed of the impeller for reliable life operated in reverse. Reversal is obtained by in
long operation. terchanging electrical connections.

Forms of Running Test Methods


The direction of airflow through the fan and the Testing
fan mounting position are defined as the “Form The air and sound performance data has been
of running”. measured by the latest version of British and
On each chart is shown the standard Form(s) of International Standards:
running for that particular fan, when mounted ISO 5801:1997 method for testing air
(J horizontally. For vertical operation add suffix “U” performance (dual numbered BS848 Ptl 1997).
for airflow up, or suffix “D” for airflow down. BS848 Pt 2 1985, method of noise testing.
The standard Form of running offered will be It is essential, when comparing fan performances,
Form B. When an alternative is available: see that the same installation category and test
chart information, please request when the fan standards are used at all times.
is ordered. Form of running is especially relevant
when weatherproofed motors are required. Acoustic Data
Arrows indicating correct rotation and direction The sound levels quoted are based on tests
of airflow are incorporated in the duct nameplate. carried out under the Woods certified laboratory
conditions. Using the spectrum corrections stated
on each performance chart, an unweighted sound
power spectrum can be obtained for the fan.

Form A Form B Form AD Motor Ratings


The motor ratings, starting, full load currents
and speeds refer to the maximum output of
the motor. When the impeller does not require
the full output, the power and currentwill be less
Form AU Form BU Form BD than the maximum quoted.

7
JM AEROFOIL
woo’
AIR MOVEMENT

QUALITY SYSTEMS

ACCREDITED LABORATORY

I,,s is 5o tersily sha,

•d Cs.fr.I AsI.cI.tI.m frmn.II..I,

r’
V
ii
— —

im / Woods Air Movement Limited certifies that the JM Aerofoil shown herein is licensed to bear
FED//
the AMCA Seal. The ratings shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and comply with the requirements of the AMCA
fIR Certified Ratings Program.

Quality Systems
Woods Air Movement Limited is committed to Quality Assurance. Registration to BS EN ISO 9001 .94, means
that Woods design is quality assured as well as the manufacture. ‘C
Our commitment to Quality Assurance doesn’t stop with the hardware. The performance data comes from
standard tests carried out in Woods own laboratory which is British Standard and AMCA accredited. Those fans
which are AMCA licensed for aerodynamic performance are identified by the AMCA Seal on the appropriate
characteristic curve(s).

A JM Aerofoil can be bought with the confidence as with all Woods products, that it will achieve the published
performance data and match the assured quality. All the Woods JM Aerofoils are fitted with P55 motors as
standard, and come with a 2 year ex works warranty.

All fans as detailed in this publication can be supplied for a one off emergency operation at temperatures up
to 200°C for 2 hours (H.T. Category 200/2). This facility is independently certified by the Loss Prevention
Certification Board (LPCB), Certificate number 386a Issue 2. Certain fans can be supplied for a one off
emergency operation at temperatures up to 400°C for 2 hours (H.T. Category 400/2 LPCB approved) Please
refer to Publication JM/HT for details. (

8
JM AEROFOIL
C HOW TO SPECIFY
Specifying The Fan Ordering The Fan
Having chosen the fan most suitable for your After identifying the best fan for your
individual application. application please order as follows:-
Please specify as follows:

1. The fan shall be manufactured by Woods 1. Fan type: JM Aerofoil Long cased (L-type),
Air Movement Limited model type JM or Short Cased (S-type) Form A or Form B.
Aerofoil, long or short cased (L or S-type).

2. Motors, squirrel cage type, insulated to class 2. Fan Code:


F, bearings lubricated with wide temperature eg: 63JM/20!8/6!24
grease, keyed shaft. To comply with BS5000 where: 63 denotes the Fan impeller
Pt 99 and IEC 34-1. Weatherproof to 1P55. diameter in centimetres.
(Overheat protection provided on most JM denotes Fan Type.
single phase motors). /20 denotes impeller hub diameter
in centimetres.
3. Impellers, precision die cast aluminium /8 denotes a nominal 8 pole speed.
hub and clamp-plate, with equally spaced, /6 denotes the number of blades.
fully adjustable precision die cast Aerofoil /24 denotes the Pitch Angle for the
section blades. All rotating aluminium required duty.
components to be X-ray examined prior to
machining to assure quality of castings. 3. Quantity required.

4. Casings, either a long cased form complete 4• Duty required at standard air and
with an externally mounted pre-wired temperature e.g. 1.60 3
m
/ s @ 50 Pa.
electrical terminal box, or short cased for
duct or plate installation. Casings are spun 5. Motor. eg: CT5
from sheet steel with integral pre-drilled
flanges, fully welded seams and hot-dipped 6. Electrical Supply:
galvanised after manufacture for excellent 220-240V/50 Hz! 14
durability. 380-420 V /50 Hz! 30

5. Mounting Arms, manufactured from mild 7. Ancillary items required.


steel hot dipped galvanised after
manufacture. Mounting Feet.
Impeller and Motor Side Guards.
6. Performance shall be independantly Silencers with or without pod.
approved by AMCA, and established in Speed Controller (electronic or auto-
accordance with 1S05801 :1997 installation transformer) or 2 speed switch type
category D, method of testing air MDS3.1 0.
performance and B5848 Pt 2 1985 method Air Operated Dampers.
of noise testing. Matching Flanges
Beilmouth Inlets.
7. Ancillaries as required. Flexible Connectors.
Vibration Isolators.

9
JM AEROFOIL
GUIDE TO FAN SELECTION AIR MOVEMENT
a
SELECTION EXAMPLE -TOTAL PRESSURE
There are two principle methods of expressing 3. Selection on Individual Fan Charts
the pressure requirements, namely, F (Total) The data provided on each performance chart is
and SF (Static) pressure. The two types of pres specifically for ducted Type D (ducted)
-

sure are related: installations for both long or short cased (S-type)
fans. Providing reasonable Type D conditions
= SF
+
dF F
= Fan Total pressure are maintained in installation of the fans, no
SF
= Fan Static pressure additional factors to volume flow or pressure
dF
= Fan Dynamic pressure need be incorporated for a suitable selection to
be made.
The international convention considers fan per
formance in terms of total pressure, but there is Plot the duty on the selected fan charts to establish
also established practice relating to the use of blade angle, sound level, absorbed power, motor
static pressure. For this reason Woods’ selec size and rating, for the particular arrangement.
tion charts are laid out on a total pressure major
scale and include a secondary grid for static ® Duty Point Required @ Standard Air (1.2
). 0.55 m
3
kg/rn
-

/s @ 100 Pa total pressure.


3
(Z
pressure. The facility to display fan performance
in terms of static pressure is necessary in order
to avoid total pressure fan selections being made Volume Flow = 0.55 3
m
/ s
based on static pressure system requirements.
Fan Total Pressure = 100 Pa
The guide selections are made for either total or
static pressures of 1 0OPa. The resulting selec Overall inlet Sound Power Level = 72 Lw
tions are quite different and highlight the conse (Interpolated from surrounding levels).
quences of selecting static pressure from charts
that only display performance in terms of total Pitch Angle required to achieve
pressure. Duty Point = 28°

Corrections to overall Sound Power level


Procedure Total Pressure
-
(F) for 28° Pitch Angle.
(Operating Point is Below shaded area):
1. Guide to Chart Numbers Frequency Hz
of Possible Selections
The charts are arranged in order of fan diameter,
starting at3l 5 mm, upto 1600 mm diameter, and
in order of fan speed for each diameter, 3,5,6,9
Sound Power
Level

(9
Inlet
Outlet
63 125 250 500 1K 2K 4K 8K
65 67 64 65 60 54 51 45 Lw
67 70 65 65 60 54 52 46 Lw

Absorbed Power @ Duty Point @ 28°


I
& 12 bladed fan impellers as available. Pitch Angle = 0.09 kW.

NOTE: The chart numbers lead to a variety of Suitable Motor for fixed speed
fan sizes, impeller configurations and speeds. application,3 phase supply, from motor
The fan selected from the alternatives available schedules = BT4
will depend on the most critical factor for the Motor Data:
particular application Volume Flow and Pressure
-
Motor Rating (kW) = 0.15
required, Size, Power Consumption, Sound Level Full Load (A) = 0.5
or First Cost. Starting Current (A) = 2.0

Speed Regulatable Versions


2. Required Duty If a speed regulatable version is required, (or
Establish the volume flow and total pressure Delta/Star(A/A) reconnect on 3 phase versions)
required of an individual fan at Standard Air (1 .2 the dutyvolume flow required should be multiplied
).
3
kg/rn by 1 .05 prior to fan selection being made. C
10
JM AEROFOIL
Fan Code: 35JM/1 6/4/5/...
WOODS AIR MOVEMENT
C
355 mm 1420 rev/mm 5 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performanceshown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effectsof appurtenances.
-

/min
3
ft 0 500 1000 1500 2000 2500
I I I I mm in
I I I I I I I I wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
16
0.6

14

0.5
12

a
( -0.4
a
D
Cl)
Cl,
a
0
a 8
0 - 0.3
I—
C
a
U
6
0.
- 0.2

4.

• 0.1
2

mo,tmtnr
flflD 000TROI
TITOCIRIIOT
InTeTflnyIonTI, Inc.

0- •0.0

( a
0

-D
a
.0
0
Cl)
.0

0..

q, — Volume Flow (m’Is)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k Angle ••
125 250 500 1k 2k 4k 8k
9 .7 -5 -5 -13 -20 -27 -35 -6 -5 -4 -5 -13 -20 -27 .35
8
-14 -10 -7 -3 -10 -16 -22 -31 -12 -8 -7 -3 -9 -16 -20 -29
-12 -6 -6 5 -13 -15 -21 -27 10 -3 -6 -5 -12 -14 -21 -27
16
-10 -6 -7 -6 -9 -12 -17 -24 -9 -3 -6 -6 -9 -12 -17 -24
v5 -6 -7 -8 -14 -18 -23 -28 .5 7 7 -13 -17 -21 -26
24- 40
- -

L L1ii 2.
SK11689 04/03/99
JM AEROFOIL
GUIDE TO FAN SELECTION WOODS AIR MOVEMENT
C
SELECTION EXAMPLE STATIC PRESSURE -

There are two principle methods of expressing 3. Selection on Individual Fan Charts
the pressure requirements, namely, F (Total) The data provided on each performance chart is
and SF (Static) pressure. The two types of pres specifically for ducted Type D (ducted)
-

sure are related: installations for both long or short cased (S-type)
fans. Providing reasonable Type D conditions
= SF
+
d
= Fan Total pressure are maintained in installation of the fans, no
SF
= Fan Static pressure additional factors to volume flow or pressure
dF
= Fan Dynamic pressure need be incorporated for a suitable selection to
be made.
The international convention considers fan per
formance in terms of total pressure, but there is Plot the duty on the selected fan charts to establish
also established practice relating to the use of blade angle, sound level, absorbed power, motor
static pressure. For this reason Woods’ selec size and rating, for the particular arrangement.
tion charts are laid out on a total pressure major
scale and include a secondary grid for static
pressure. The facility to display fan performance
Duty Point Required @ Standard Air (1.2
kg/rn
)
3 . 0.55 m
-

/s @ 100 Pa static pressure.


3
C)
in terms of static pressure is necessary in order
to avoid total pressure fan selections being made Volume Flow = 0.55 m
/s
3
based on static pressure system requirements.
Fan Static Pressure = 100 Pa
The guide selections are made for either total or
static pressures of lOOPa. The resulting selec Overall inlet Sound Power Level = 74 Lw
tions are quite different and highlight the conse
quences of selecting static pressure from charts Pitch Angle required to achieve
that only display performance in terms of total Duty Point = 32°
pressure.
Corrections to overall Sound Power level
for 32° Pitch Angle.
Procedure Static Pressure
-
(SF) (Operating Point is above shaded area):-
Frequency Hz
1. Guide to Chart Numbers Sound Power 63 125 250 500 1K 2K 4K 8K
of Possible Selections
The charts are arranged in order of fan diameter,
Level Inlet
Outlet
69 68 67 66 60 56 51 46 Lw
71 69 67 67 61 57 53 48 Lw C)
starting at315 mm, upto 1600mm diameter, and Absorbed Power @ Duty Point @ 32°
in order of fan speed for each diameter, 3,5,6,9 Pitch Angle = 0.11 kW.
& 12 bladed fan impellers as available.
Suitable Motor for fixed speed
NOTE: The chart numbers lead to a variety of application,3 phase supply, from motor
fan sizes, impeller configurations and speeds. schedules = BT4
The fan selected from the alternatives available
will depend on the most critical factor for the Motor Data:
particular application Volume Flow and Pressure
-
Motor Rating (kW) = 0.15
required, Size, PowerConsumption, Sound Level Full Load (A) = 0.5
or First Cost. Starting Current (A) = 2.0

Speed Regulatable Versions


2. Required Duty If a speed regulatable version is required, (or
Establish the volume flow and static pressure Delta/Star(A/A) reconnect on 3 phase versions)
required of an individual fan at Standard Air (1 .2 the duty volume flow required should be multiplied
).
3
kg/rn by 1 .05 prior to fan selection being made.

12
JM AEROFOIL
, Fan Code: 35J Mu 6/4/5/... WOODS AIR MOVEMENT

355 mm 1420 rev/mm 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for instalfationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.
-

/min
3
ft 0 500 1000 1500 2000 2500
t I mm in
I I I I I I I wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
16
0.6

14’

• 0.5
12

0- 10 • 0.4

8
0.3

• 0.2

4-

‘0.1
2-

flDCOATROI
flISOCIATIOA
flTIRITATIOAM. INC.
0- 0.0

01
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle ‘•
500 Bk Angle E E
-9 -7 -5 -5 -13 -20 -27 -6 -5 .4 -5 -13 -20 -27 .35
8
-14 -10 -7 -3 -10 -16 -22 -31 -12 -8 -7 -3 9 -16 -20 -29
-12 -6 -6 -5 -13 -15 -21 -27 -10 -3 -6 -5 -12 -14 -21 -27
16 16
-10 -6 .7 -6 -9 -12 -17 - -24 -9 -3 -5 -6 -9 -12 -17 -24
5 -6 -7 -8 -14 -18 -23 -28 .5 -7 -7 -13 -17 -21 -26
24- 40 24 40
i -5 -a -7 -12 -16 -21 -2711 -5 -2 -7 -7 12116 -20 -26

SK11689 04/03/99
C

(C

C
JM AEROFOIL
Motor Frame Size Schedules
220—240 V / 50 Hz I 1 p Speed Regulation Details
Pitch I Pitch Speed Controller
Speed Motor Full Load Starting Efficiency Power
Angle
Code Range Motor Rating Current Current Factor Capacitor Angle Auto-
Range Electronic
rev/mm (kW) (A) d.o.l. (A) % cos 0 l- Transformer
(°) I L (°)
31 JM/1 6/6/5/... 900 16-40 BT5 0.04 0.5 0.7 44 0.91 2
22-40 BT5 0.04 0.5 0.7 44 0.91 2 22-40 ME1.1 MT1.1
31 JM/1 6/4/5/... 1420 12-36 BT5 0.07 0.6 1.8 60 0.92 4
24-38 BT5 0.07 0.6 1.8 60 0.92 4 24-38 ME1.1 MT1.1
31 JM/1 6/2/5/... 2840 8-14 BT5 0.2 1.5 4 63 0.95 10
18-20 875 0.3 2.1 5 64 0.95 15
26-32 BT9 0.5 3.3 9 68 0.98 20
36-40 CT5 0.75 4.9 8.5 71 0.93 20

35JM/16/6/5/... 900 12-40 875 0.04 0.5 0.7 44 0.91 2 12-40 ME1.1 MT1.1

35JM/16/4/5/... 1420 8-22 BT5 0.07 0.6 1.8 60 0.92 4


16-24 BT5 0.07 0.6 1.8 60 0.92 4 16-24 ME1.1 MT1.1
28-40 BT4 0.13 1 2 58 0.95 6 28-40 MEl .1 MT1 .1
35JM/16/2/5/... 2840 10-12 BT5 0.3 2.1 5 64 0.95 15
16-20 BT9 os 33 9 68 0.98 20
24-28 CT5 0.75 4.9 8.5 71 0.93 20
32-34 CT5 1 5.9 11.5 74 0.99 i 30
36-40 I CT9 1.4 8.3 27 74 0.99 50

4OJM/16/6/5/... 900 8-28 BT5 0.04 0.5 0.7 44 0.91 2 8-28 ME1.1 MT1.1
32-40 BT5 0.09 0.8 1.6 50 0.95 5 32-40 ME1.1 MT1.1
4OJM/16/4/5/... 1420 10-12 BT5 0.07 0.6 1.8 60 0.92 4 10-12 ME1.1 MT1.1
18-24 BT4 0.13 1 2 58 0.95 6 18-24 ME1.1 MT1.1
26-28 BT5 0.16 1.2 2.7 62 0.95 5 26-28 MEl .3 MT1 .5
30-36 BT5 0.23 1.6 2.7 64 0.95 8
34-40 BT9 0.25 1.7 3.8 66 0.97 10 34-40 MEl .3 MT1 .5
4OJM/1 6/2/5/... 2840 10-10 BT9 0.5 3.3 9 68 0.98 20
14-16 CT5 0.75 4.9 8.5 71 0.93 20
20-22 CT5 1 5.9 11.5 74 0.99 30
24-28 CT9 1.4 8.3 27 74 0.99 50

45JM/l6/6/5/... 900 18-24 BT4 0.06 0.6 1 46 0.95 4 18-24 ME1.1 MT1.1
22-34 BT5 0.09 0.8 1.6 50 0.95 5 22-34 ME1.1 MT1.1
36-40 BT9 0.12 1.1 2.2 54 0.92 8 36-40 ME1.3 MT1.5
45JM/16/4/5/... 1420 10-14 BT4 0.13 1 2 58 0.95 6 10-14 ME1.1 MT1.l
18-18 BT5 0.16 1.2 2.7 62 0.95 5 18-18 ME1.3 MT1.5
22-22 BT5 0.2 1.5 2.7 62 0.95 8 22-22 ME1.3 MT1.5
24-26 BT9 0.25 1.7 3.8 66 0.97 10 24-26 ME1.3 MT1.5
, 24-30 BT9 0.3 2.1 5.3 65 0.95 10 24-30 ME1.3 . MT1.5
36-40 CT5 0.45 2.9 7 68 0.99 15 36-40 ME1.3 MT1.5
45JM/16/2/5/...: 2840 8-10 CT5 0.75 4.9 8.5 71 0.93 20
12-14 CT5 1 5.9 11.5 74 0.99 30
16-18 CT9 1.4 8.3 27 74 0.99 50

45JM/20/6/3/... 900 8-24 BT5 0.04 ! 0.5 0.7 44 0.91 2 8-24 ME1.1 MT1.1
24-34 BT4 0.06 0.6 1 46 0.95 4 24-34 MEl .1 MT1.1
28-36 BT5 0.09 0.8 1.6 50 0.95 5 28-36 MEl .1 MT1,1
45JM/20/4/3/... 1420 10-12 875 0.07 0.6 1.8 60 0.92 4 10-12 ME1.l MT1.1
16-22 BT4 0.13 1 2 58 0.95 6 16-22 ME1.1 MT1 .1
24-26 BT5 0.16 1.2 2.7 62 0.95 5 24-26 MEl .3 MT1.5
30-30 BT5 0.2 1.5 2.7 62 0.95 8 30-30 ME1.3 MT1.5
32-36 BT9 0.25 1.7 3.8 66 0.97 10 32-36 ME1.3 MT1 .5
45JM/20/2/3/... 2910 10-10 BT9 0.5 3.3 9 68 0.98 20
14-16 CT5 0.75 4.9 8.5 71 0.93 20
18-20 CT5 1 5.9 11.5 74 0.99 30
22-24 CT9 1.4 8.3 27 74 0.99 50
Although motors are rated 220/240 V electrical supply capacitors should be rated f x 450 V AC

15
JM AEROFOIL
woo’
AIR MOVEMENT

Motor Frame Size Schedules 0


220—240 V / 50 Hz I 1 ( Speed Regulation Details
Speed Pitch Pitch Speed Controller
Motor Full Load Starting Efficiency Power
Angle Capacitor. Angle
Code Motor Rating Current Current Factor Range Electronic Auto
Range
rev/rn in (0) (kW) (A) do]. (A) % cos 0 ‘f (°) Transformer
4OJIVI/ZU/b/b/... 900 16-24 BT4 0.06 0.6 46 0.95 4 16-24 ME1.1 MT1.1
22-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.l
34-40 BT9 0.12 1.1 2.2 54 0.92 8 34-40 ME1.3 MT1.5

45JM/20/4/6/... 1420 10-12 BT4 0.13 2 58 0.95 6 10-12 ME1.1 MT1.1


16-16 BT5 0.16 1.2 2.7 62 0.95 5 16-16 ME1.3 MT1.5
22-28 BT9 0.3 2.1 5.3 65 0.95 10 22-28 ME1.3 MT1.5
34-40 CT5 0.45 2.9 7 68 0.99 15 34-40 MEl .3 MT1.5

45JM/20/2/6t.. 2910 12-12 CT5 1 5.9 11.5 74 0.99 30


14-16 CT9 1.4 8.3 27 74 0.99 50

5OJM/16/6/5/... 915 16-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1.1
24-28
30-32
BT9
BT9
0.12
0.14
1.1
1.2
2.2
2.8
54
54
0.92
0.92
8
8
24-28
30-32
ME1.3
ME1.3
MT1.5
MT1.5 Q)
36-40 CT5 0.19 1.8 3 48 0.96 8 36-40 ME1.3 MT1.5

5OJM/16/4/5/... 1420 14-14 BT5 0.2 1.5 2.7 62 0.95 8 14-14 ME1.3 MT1.5
16-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
26-28 CT5 0.45 2.9 7 68 0.99 15 26-28 ME1.3 MT1.5
32-34 CT5 0.55 3.7 9.5 65 0.99 25 32-34 MEl .6 MT1 .5
38-40 CT9 0.68 4.2 11 76 0.96 25 38-40 MEl .6 MT1.5

5OJM/20/6/3/... 915 18-24 BT4 0.06 0.6 46 0.95 4 18-24 ME1.1 MT1.1
22-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.1
34-36 BT9 0.12 1.1 2.2 54 0.92 8 34-36 ME1.3 MT1.5

5OJM/20/4/3/... 1420 12-14 BT4 0.13 2 58 0.95 6 12-14 ME1.1 MT1.1


16-18 BT5 0.16 1.2 2.7 62 0.95 5 16-18 ME1.3 MT1.5
24-30 BT9 0.3 2.1 5.3 65 0.95 10 24-30 ME1.3 MT1.5
34-36 CT5 0.45 2.9 7 68 0.99 15 34-36 ME1.3 MT1.5

5OJM/20/2/3/... 2910 12-12 CT5 1 5.9 11.5 74 0.99 30


14-16 CT9 1.4 8.3 27 74 0.99 50

5OJM/20/6/6/... 915 10-14 BT4 0.06 0.6 46 0.95 4 10-14 ME1.1 MT1.1
14-22 BT5 0.09 0.8 1.6 50 0.95 5 14-22 ME1.1 MT1.1
24-26 BT9 0.12 1.1 2.2 54 0.92 8 24-26 ME1.3 MT1.5
28-30 BT9 0.14 1.2 2.8 54 0.92 8 28-30 ME1.3 MT1.5
34-40 CT5 0.19 1.8 3 48 0.96 8 34-40 ME1.3 MT1.5
C
50JM/20/4/6/... 1420 14-16 BT9 0.25 1.7 3.8 66 0.97 10 14-16 ME1.3 MT1 .5
16-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
24-26 CT5 0.45 2.9 7 68 0.99 15 24-26 ME1.3 MT1.5
30-32 CT5 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.5
36-38 CT9 0.68 4.2 11 76 0.96 25 36-38 ME1.6 MT1 .5
38-40 CT9 0.97 6.2 19 72 0.95 40 38-40 . ME1.12 MT1.8

56JM/16/6/5/... 900 8-14 BT5 0.09 0.8 1.6 50 0.95 5 8-14 ME1.1 MT1 .1
20-22 BT9 0.14 1.2 2.8 54 0.92 8 20-22 ME1.3 MT1.5
24-28 CT5 0.19 1.8 3 48 0.96 8 24-28 ME1.3 MT1.5
32-34 CT5 0.24 2.1 4 51 0.98 12 32-34 ME1.3 MT1.5
38-40 CT5 0.3 2.4 4 56 0.98 15 38-40 ME1.3 MT1.5

56JM/16/4/51... 1420 10-12 BT9 0.3 2.1 5.3 65 0.95 10 10-12 ME1.3 MT1.5
16-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1 .5
22-22 CT5 0.55 3.7 9.5 65 0.99 25 22-22 MEl .6 MT1.5
24-26 CT9 0.7 5 15 64 0.96 40 24-26 ME1.6 MT1.8
28-32 CT9 0.97 6.2 19 72 0.95 40 28-32 ME1.12 MT1.8
36-38 CT9 1.1 7.2 23 70 0.95 50 36-38 N/A MT1 .12

56JM/20/6/3/... 900 12-16 BT4 0.06 0.6 46 0.95 4 12-16 ME1.1 MT1.1
16-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1 .1
24-28 BT9 0.12 1.1 2.2 54 0.92 8 24-28 ME1.3 MT1.5
30-30
34-36
BT9
CT5
0.14
0.19
1.2
1.8
2.8
3
54
48
0.92
0.96
8
8
30-30
34-36
ME1.3
ME1.3
MT1.5
MT1.5 C
Although motors are rated 220/240 V electrical supply capacitors should be rated l.Lf x 450 V AC

16
JM AEROFOIL
WOODS
AIR MOVEMENT
Motor Frame Size Schedules
220—240 V I 50Hz / 1 0 Speed Regulation Details
Speed Motor Full Load Starting Efficiency Power Pitch Speed Controller
Ar
Code Range Motor Rating Current Current Factor Capacitor Angle Auto
rev/mm
.

% Range Electronic
(kW) (A) d.o.I. (A) cos 0 () Transformer
56JM/20/4/3/... 1420 0.2 1.5 2.7 62 0.95 8 14-14 ME1.3 MT1.5
0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
26-28 CT5 0.45 2.9 7 68 0.99 15 26-28 ME1.3 MT1.5
30-32 CT5 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.5
34-36 CT9 0.68 4.2 11 76 0.96 25 34-36 ME1.6 MT1.5
56JM/20/2/3/... 2910 14-18 F2225 2.7 14 50 84 0.98 90
56JM/20/6/6/... 900 8-12 BT5 0.09 0.8 1.6 50 0.95 5 8-12 ME1.1 MT1.1
16-18 BT9 0.12 1.1 2.2 54 0.92 8 16-18 ME1.3 MT1.5
20-20 BT9 0.14 1.2 2.8 54 0.92 8 20-20 ME1.3 MT1.5
24-26 CT5 0.19 1.8 3 48 0.96 8 24-26 ME1.3 MT1.5
30-32 CT5 0.24 2.1 4 51 0.98 12 30-32 ME1.3 MT1.5
36-38 CT5 0.3 2.4 4 56 0.98 15 36-38 ME1.3 MT1.5
1
56JM/20/4/6/... 1420 10-10 8T9 0.3 2.1 5.3 65 0.95 10 10-10 ME1.3 MT1.5
16-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1.5
20-20 CT5 0.55 3.7 9.5 65 0.99 25 20-20 ME1.6 MT1.5
22-26 CT9 0.7 5 15 64 0.96 40 22-26 ME1.6 MT1.8
26-30 CT9 0.97 6.2 19 72 0.95 40 26-30 ME1.12 MT1.8
34-36 CT9 1.1 7.2 23 70 0.95 50 34-36 N/A MT1.12
63JM/20/6/3/... 900 8-10 BT5 0.09 0.8 1.6 50 0.95 5 8-10 ME1.1 MT1.1
12-14 BT9 0.12 1.1 2.2 54 0.92 8 12-14 ME1.3 MT1.5
16-16 BT9 0.14 1.2 2.8 54 0.92 8 16-16 ME1.3 MT1.5
20-22 CT5 0.19 1.8 3 48 0.96 8 20-22 ME1.3 MT1.5
26-26 CT5 0.24 2.1 4 51 0.98 12 26-26 ME1.3 MT1.5
30-32 CT5 0.3 2.4 4 56 0.98 15 30-32 ME1.3 MT1.5
63JM/20/4/3/... 1420 14-14 CT5 0.45 2.9 7 68 0.99 15 14-14 ME1.3 MT1.5
20-20 CT9 0.68 4.2 11 76 0.96 25 20-20 ME1.6 MT1.5
20-22 CT9 0.7 5 15 64 0.96 40 20-22 ME1.6 MT1.8
22-26 CT9 0.97 6.2 19 72 0.95 40 22-26 ME1.12 MT1.8
28-30 CT9 1.1 7.2 23 70 0.95 50 28-30 N/A MT1.12
63JM/20/6/6/... 900 12-14 CT5 0.19 1.8 3 48 0.96 8 12-14 ME1.3 MT1.5
18-18 CT5 0.24 2.1 4 51 0.98 12 18-18 ME1.3 MT1.5
22-22 CT5 0.3 2.4 4 56 0.98 15 22-22 ME1.3 MT1.5
28-30 CT9 0.43 3.3 7.5 59 0.96 15 28-30 ME1.6 MT1.5
34-34 CT9 0.52 4 9.2 59 0.95 20 34-34 MEl .6 MT1 .8
63JM/20/4/6/... 1420 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1.8
14-16 CT9 0.97 6.2 19 72 0.95 40 14-16 ME1.12 MT1.8
20-22 CT9 1.1 7.2 23 70 0.95 50 20-22 N/A MT1.12
71JM/20/6/3/... 900 12-12 CT5 0.19 1.8 3 48 0.96 8 12-12 ME1.3 MT1.5
16-18 CT5 0.24 2.1 4 51 0.98 12 16-18 ME1.3 MT1.5
20-22 CT5 0.3 2.4 4 56 0.98 15 20-22 ME1.3 MT1.5
26-28 CT9 0.43 3.3 7.5 59 0.96 15 26-28 ME1.6 MT1.5
32-32 CT9 0.52 4 9.2 59 0.95 20 32-32 ME1.6 MT1.8
71JM/20/4/3/... 1440 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1.8
14-16 CT9 0.97 6.2 19 72 0.95 40 14-16 ME1.12 MT1.8
20-20 CT9 1.1 7.2 23 70 0.95 50 20-20 N/A MT1.12
71JM/20/6/6/... 900 12-12 CT5 0.3 2.4 4 56 0.98 15 12-12 ME1.3 MT1.5
18-18 CT9 0.43 3.3 7.5 59 0.96 15 18-18 ME1.6 MT1.5
22-22 CT9 0.52 4 9.2 59 0.95 20 22-22 ME1.6 MT1.8
8OJM/20/6/3/... 935 14-14 CT5 0.3 2.4 4 56 0.98 15 14-14 ME1.3 MT1.5
18-20 CT9 0.43 3.3 7.5 59 0.96 15 18-20 ME1.6 MT1.5

Although motors are rated 220/240 V electrical supply capacitors should be rated ILl x 450 V AC

17
JM AEROFOIL
Motor Frame Size Schedules a
380-420 V / 50 Hz /3 0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
% Range Electronic Auto
rev/mm Angle (0)
(kW) (A) d.o.l. (A) cos 0 (0)
Transformer
31JM/16/6/5/... 900 40 BT4 0.06 0.3 0.8 46 0.6 NRatt is angle

31 JM/1 6/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 34-40 ME3.2D MT3.0.5

31 JM/1 6/2/5/... 2840 24 BT5 0.35 0.9 3.6 66 0.85


36 BT9 0.58 1.4 6 71 0.85
40 CT5 0.95 2 9.5 75 0.9

35JM/1 6/6/5/... 900 40 BT4 0.06 0.3 0.8 46 0.6 28-40 ME3.2D MT3.0.5

35JM/1 6/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 22-40 ME3.2D MT3.0.5

35JM/1 6/2/5/... 2840 14


22
34
BT5
BT9
CT5
0.35
0.58
0.95
0.9
1.4
2
3.6
6
9.5
66
71
75
0.85
0.85
0.9
C
40 CT9 1.7 3.5 20 78 0.9

40JM/1 6/6/5/... 900 38 BT4 0.06 0.3 0.8 46 0.6 18-3 8 ME3.2D MT3.0.5
40 BT5 0.09 0.5 1.2 50 0.58 36-40 ME3.2D MT3.0.5

4OJM/1 6/4/5/... 1420 24 BT4 0.13 0.5 1.8 58 0.7 14-24 ME3.2D MT3.0.5
34 BT5 0.2 0.7 2.4 62 0.7 26-34 ME3.2D MT3.1
40 BT9 0.3 0.9 4.6 65 0.75 36-40 ME3.2D MT3.1

40JM/1 6/2/5/... 2840 12 BT9 0.58 1.4 6 71 0.85


20 CT5 0.95 2 9.5 75 0.9
32 CT9 1.7 3.5 20 78 0.9

45JM/1 6/6/5/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
28 BT4 0.08 0.4 50 0.6
34 BT5 0.09 0.5 1.2 50 0.58 26-34 ME3.2D MT3.0.5
38 BT5 0.12 0.5 1.2 54 0.7
40 BT9 0.14 0.6 1.8 54 0.66 36-40 ME3.2D MT3.1

45JM/1 6/4/5/... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.2D MT3.0.5
22 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.1
30
36
40
BT9
BT9
CT5
0.3
0.39
0.58
0.9
1.1
1.7
4.6
4.6
6.5
65
67
67
0.75
0.75
0.74
24-30

40-40
ME3.2D

ME3.2D
MT3.1

MT3.2
0
45JM/1 6/2/5/... 2840 12 CT5 0.95 2 9.5 75 0.9
20 CT9 1.7 3.5 20 78 0.9

45JM/20/6/3/... 900 34 BT4 0.06 0.3 0.8 46 0.6 16-34 ME3.2D MT3.0.5
36 BT5 0.09 0.5 1.2 50 0.58 32-36 ME3.2D MT3.0.5

45JM/20/4/3/... 1420 22 BT4 0.13 0.5 1.8 58 0.7 12-22 ME3.2D MT3.0.5
30 BT5 0.2 0.7 2.4 62 0.7 22-30 ME3.2D MT3.1
36 BT9 0.3 0.9 4.6 65 0.75 32-36 ME3.2D MT3.1

45JM/20/2/3/... 2910 12 BT9 0.58 1.4 6 71 0.85


18 CT5 0.95 2 9.5 75 0.9
28 CT9 1.7 3.5 20 78 0.9
36 F2225 3.8 7.1 44 84 0.92

45JM/20/6/6/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
32 BT5 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.5
36 BT5 0.12 0.5 1.2 54 0.7
40 8T9 0.14 0.6 1.8 54 0.66 34-40 ME3.2D MT3.1

18
JM AEROFOIL
Motor Frame Size Schedules
380—420 V I 50 Hz / 3 (P Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle —_____________

Range Electronic Auto


rev/mm Angle (0)
(kW) (A) d.o.l. (A) % cos 0 (0)
Transformer
45JM/20/4/6/... 1420 12 BT4 0.13 0.5 1.8 58 0.7 8-12 ME3.2D MT3.0.5
20 BT5 0.2 0.7 2.4 62 0.7 14-20 ME3.2D MT3.1
28 8T9 0.3 0.9 4.6 65 0.75 22-28 ME3.2D MT3.1
34 BT9 0.39 1.1 4.6 67 0.75
40 CT5 0.58 1.7 6.5 67 0.74 38-40 ME3.2D MT3.2
‘45JM/20/2/6/... 2910 12
20 3.5 20 78 0.9
34 F2225 3.8 7.1 44 84 0.92
40 P2229 6.2 11 90 86 I 0.92

5OJM/16/6/5/... 915 16 BT4 0.06 0.3 0.8 46 0.6 8-16 ME3.2D MT3.0.5
22 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.5
26 BT5 0.12 0.5 1.2 54 0.7
32 BT9 0.14 0.6 1.8 54 0.66 24-32 ME3.2D MT3.1
36 BT9 0.19 0.7 1.8 59 0.66
40 CT5 0.22 0.8 2.5 55 0.7 36-40 ME3.2D MT3.1
5OJM/1614151... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
34 CT5 0.58 . 1.7 6.5 67 0.74 28-34 ME3.2D MT3.2
38 CT5 0.71 1.9 6.5 71 0.75
40 CT9 0.9 2.3 9 72 0.78 36-40 ME3.2D MT3.2

50JM1201613/... 915 24 8T4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
32 BT5 i 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.5
36 BT9 0.14 0.6 1.8 54 0.66 34-36 ME3.2D MT3.1

5OJM/20/4/31... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.2D MT3.0.5
22 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.1
30 BT9 0.3 0.9 4.6 65 075 24-30 ME3.2D MT3.1
36 CT5 0.58 1.7 6.5 67 0.74 36-36 ME3.2D MT3.2
5OJM/20/2/3/... 2910 12 CT5 0.95 2 9.5 75 0.9
20 CT9 1.7 3.5 20 78 0.9
34 F2225 3.8 7.1 44 84 0.92
36 P2229 6.2 11 90 86 0.92

50JM120/6161... 915 14 BT4 0.06 0.3 0.8 46 0.6 8-14 ME3.2D MT3.0.5
22 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.5
30 BT9 0.14 0.6 1.8 I 54 0.66 24-30 ME3.2D MT3.1
34 BT9 0.19 0.7 1.8 59 0.66
40 CT5 0.22 0.8 2.5 55 0.7 34-40 ME3.2D MT3.1

5OJM/20/4/6/... 1420 12 BT5 0.2 0.7 2.4 62 0.7 10-12 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
32 CT5 0.58 1.7 6.5 67 0.74 26-32 ME3.2D MT3.2
36 CT5 0.71 1.9 6.5 71 0.75
40 CT9 0.9 2.3 9 72 0.78 34-40 ME3.2D i MT3.2

5OJM/20/2/6/... 2910 12 CT9 1.7 3.5 20 78 0.9


24 F2225 3.8 7.1 44 84 0.92
34 F2229 6.2 11 90 86 0.92

56JM/16/8/5/... 680 24 BT5 0.065 0.5 0.8 34 0.57 20-24 ME3.5S MT3.0.5
32 BT9 0.09 0.5 0.9 42 0.57 26-32 ME3.2D MT3.1
40 CT5 0.13 0.7 1.5 47 0.6 34-40 I ME3.2D MT3.1

19
JM AEROFOIL
WOODS
AIR MOVEMENT

Motor Frame Size Schedules C

380—420 V I 50 Hz / 3 0 Speed Regulation Details


Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
Range Electronic Auto
rev/mm Angle (0)
(kW) (A) d.o.l. (A) % COS 0 Transformer
56JM/1 6/6/5/... 900 10 BT4 0.08 0.4 50 0.6
14 BT5 0.09 0.5 1.2 50 0.58 10-14 ME3.2D MT3.0.5
22 BT9 0.14 0.6 1.8 54 0.66 16-22 ME3.2D MT3.1
32 CT5 0.22 0.8 2.5 55 0.7 24-32 ME3.2D MT3.1
40 CT5 0.3 1.1 3.3 56 0.7 34-40 ME3.2D MT3.2

56JM/1 6/4/5/... 1420 12 BT9 0.3 0.9 4.6 65 0.75 10-12 ME3.2D MT3.1
24 CT5 0.58 1.7 6.5 67 0.74 18-24 ME3.2D MT3.2
26 CT5 0.71 1.9 6.5 71 0.75
32 CT9 0.9 2.3 9 72 0.78 26-32 ME3.2D MT3.2
40 CT9 1.15 3 14 71 0.78 34-40 ME3.2D N/A

56JM/20/6/3/... 900 16
22
30
BT4
BT5
BT9
0.06
0.09
0.14
0.3
0.5
0.6
0.8
1.2
1.8
46
50
54
0.6
0.58
0.66
8-16
18-22
24-30
ME3.2D
ME3.2D
ME3.2D
MT3.0.5
MT3.0.5
MT3.1
C,,
34 BT9 0.19 0.7 1.8 59 0.66
36 CT5 0.22 0.8 2.5 55 0.7 34-36 ME3.2D MT3.1

56JM/20/4/3/... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
32 CT5 0.58 1.7 6.5 67 0.74 28-32 ME3.2D MT3.2
34 CT5 0.71 1.9 6.5 71 0.75
36 CT9 0.9 2.3 9 72 0.78 34-36 ME3.2D MT3.2

56JM/20/2/3/... 2910 12 CT9 1.7 3.5 20 78 0.9


24 F2225 3.8 7.1 44 84 0.92
34 F2229 6.2 11 90 86 0.92

56JM/20/6161... 900 12 BT5 0.09 0.5 1.2 50 0.58 10-12 ME3.2D MT3.0.5
20 BT9 0.14 0.6 1.8 54 0.66 16-20 ME3.2D MT3.1
24 BT9 0.19 0.7 1.8 59 0.66
30 CT5 0.22 0.8 2.5 55 0.7 24-30 ME3.2D MT3.1
38 CT5 0.3 1.1 3.3 56 0.7 32-38 ME3.2D MT3.2
40 CT9 0.4 1.5 5.3 66 0.6 40-40 ME3.2D MT3.2

56JM/20/4161... 1420 10
14
22
BT9
BT9
CT5
0.3
0.39
0.58
0.9
1.1
1.7
4.6
4.6
6.5
65
67
67
0.75
0.75
0.74
10-10

18-22
ME3.2D

ME3.2D
MT3.1

MT3.2
C
24 CT5 0.71 1.9 6.5 71 0.75
30 CT9 0.9 2.3 9 72 0.78 24-30 ME3.2D MT3.2
36 CT9 1.15 3 14 71 0.78 32-36 ME3.2D N/A
40 CT9 1.4 3.5 14 74 0.77

56JM/20/216/... 2910 14 F2225 3.8 7.1 44 84 0.92


24 F2229 6.2 11 90 86 0.92

63JM/20/8/3/... 680 18 BT5 0.065 0.5 0.8 34 0.57 16-18 ME3.5S MT3.0.5
24 BT9 0.09 0.5 0.9 42 0.57 20-24 ME3.2D MT3.1
32 CT5 0.13 0.7 1.5 47 0.6 26-32 ME3.2D MT3.1
36 CT9 0.18 0.7 1.7 56 0.66 34-36 ME3.2D MT3.1

63JM/20/6/3/... 900 10 BT5 0.09 0.5 1.2 50 0.58 8-10 ME3.2D MT3.0.5
16 BT9 0.14 0.6 1.8 54 0.66 12-16 ME3.2D MT3.1
20 BT9 0.19 0.7 1.8 59 0.66
26 CT5 0.22 0.8 2.5 55 0.7 20-26 ME3.2D MT3.1
32 CT5 0.3 1.1 3.3 56 0.7 28-32 ME3.2D MT3.2
36 CT9 0.4 1.5 5.3 66 0.6 34-36 ME3.2D MT3.2

20
JMAEROFOIL
WOODS
AIR MOVEMENT
CONTENTS

Page:

JM Aerofoil - Introduction 4 5 -

Specification 6 7 -

Quality Systems 8

How To Specify 9

Guide To Fan Selection - Total Pressure 10 -11


Static Pressure 12 13 -

Motor Frame Size Schedules - Single Phase Single Speed 15 17


- -

Three Phase Single Speed 18 -30


-

Three Phase -Two Speed 31 -60

Performance Curves SK11685-


SK11865

Dimensions and Weights 61 - 66

Ancillaries 67 68 -

Useful Information 69

3
JM AEROFOIL INTRODUCTION -

Air movement technology is a world of In fact Woods products are marketed and
specialised knowledge and one in which Woods installed in over 100 countries, with applications
Air Movement Limited are not just the specialists ranging from the world’s largest engineering
but the acknowledged leaders. Woods extensive projects to the smallest poultry houses.
knowledge of designs and applications extends Whatever the product size or cost it is Woods
back over 90 years of experience as one of the policy to provide the highest quality at
world’s largest manufacturers of fans and air competitive prices, all backed by dedicated staff,
moving equipment. fully trained to provide customer satisfaction.

Based in Coichester, in the U.K., Woods have Woods Air Movement Limited is a BS EN ISO
extensive laboratories that constantly develop 9001:94 Registered Company.
new concepts and product ranges, enabling the
company to maintain its market leadership. In In line with the Company’s strict adherence to
addition Woods have three sales centres in the the highest quality assurance standards, regular
U.K. together with subsidiary companies in Italy, quality audits occur ensuring that the Woods JM
Germany, Finland, France, Singapore and the Aerofoil consistently meet the catalogue
U.S.A. plus, a network of fully trained local staff specifications, now independently endorsed by
in 70 different countries with intimate knowledge the Air Movement and Control Association
of local needs. International (AMCA).

wooDs
AIR MOVEMENT *‘
4
All Aluminium Precision Die-Cast
Impeller
A unique high efficiency aerofoil section blade
within a purposely smoothed hub and clamp- Fixings
plate for adjustable pitch angle flexibility. The All fixings are protected with an organically
Woods impellers are all precision die-castto offer based zinc coating to provide excellent
thin aerofoil sections for low generation of noise corrosion resistance.
levels. Every cast aluminium component is X
rayed using Real Time Radiography inspection
prior to assembly. This feature can provide
evidence of casting quality against product liability
legislation if
specified.

Arms
Mounting arms are specially designed to offer
“T” Slot IPad Mounted Fan Motors minimal resistance to airf low. These arms are
All Woods JM range of tans incorporate an carefully spaced away from the impeller to
electrical power drive specifically designed to minimise noise generation.
optimise fan performance, and minimise the The arms also improve the cooling of the motor,
obstruction to airflow. hence increasing motor performance and life.
Totally enclosed, pad mounted design to All arms are hot dipped galvanised after
designation lP55, Class F insulation as standard. manufacture for maximum resistance to
Directly coupled to the fan impeller to minimise corrosion.
drive losses. Overheat protection is included on
single phase machines and available on others. j

Casings
Available in either a long cased form complete
with an externally mounted pre-wired electrical
terminal box, or short cased for duct or plate
Testing
installation. Casings are spun from sheet
Performance data has been obtained in
steel with integral pre-drilled flanges, fully
accordance with the internationally recognised
welded seams and hot-dipped galvanised after
standard 1S05801 :1997 installation category D
manufacture for excellent durability.
-

(AMCA approved) for aerodynamic performance


and BS 848 Part 2 (1985) for acoustic
performance. ,

5 WOODS
AIR MOVEMENT
JM AEROFOIL
SPECIFICATION
I wooii
AIR MOVEMENT
C

Motors performance and minimise the generation of


noise. The thin sections obtained by precision
Constructed from aluminium up to frame size die cast manufacturing techniques help promote
D160, cast iron above as standard with special these particular features whilst also allowing a
“T” slot or pad mounted fixings. lighter weight assembly to be produced.
Suitable for horizontal through to vertical shaft Precision die cast aluminium hub and clamp-
operation. plate, with equally spaced, fully adjustable, high
Supplied 1P55, with removable drain plugs. pressure die cast aerofoil section blades.
Bearings lubricated with wide temperature range All rotating aluminium components are X-ray
grease, sealed for life. examined prior to machining to assure quality.
Continuous operating range 400 C to +500 C, Balanced to BS6861 Part 1 1987 (ISO 1940-
minimum starting temperature -20°C(for other 1986) Grade G6.3. Corrosion resistant and
operating temperatures please enquire). suitable for continuous outside use from -40°C to
Insulation class F as standard. +50°C, (for other operating temperatures please
2 speed operation by Delta/Star(A/A) enquire).
reconnection available on most three phase
motor up to frame size F22. Non-overloading
Integral pre-wired capacitor on most single phase JM Aerofoil fans have a non-overloading
fans. characteristic; the peak power input occurs within
Ratings comply with BS5000 Part 99 and lEO 34-1. the range of normal operating pressures and is
Two speed motors available always exceeded by the motor rating.
Pole Change (PC) or Dahlander Ancillaries
Two speeds can be obtained by reconnecting a single
Motor and Impeller side guards to comply with
winding via six winding terminals to give two separate
BS848 Pt 5., and draft ISO standard.
pole numbers.
Choice of auto-transformer or electronic speed
Dual Wound
controllers.
Thistypeofmotorhastwoseparate individual windings
2 speed switch for Delta/Star (A/A) reconnection,
of the requisite poles to give the speeds required.
Silencers.
Electrical Supply Mounting Feet for both horizontal or vertical
220-240 V 50 Hz single phase (10) operation.
Matching Flanges, Flexible Connectors.
380-420 V 50 Hz three phase (30)
(60 Hz variants and other voltages are available Air Operated Dampers for horizontal or vertical 0
on request). up operation. Belimouth inlets. Vibration Isolators.
Speed control can be provided by Woods Air Control gear complete with BMS contacts
Movement’s range of electronic and auto available on request.
transformertype speed controllers. Speed control Finish
details are based on the adoption of the more Fan casings, motor mounting arms, mounting
usual and technically superior three-wire circuit. feet, matching flanges and guards are all hot
Referto Colchester if two wire control is required. dipped galvanised after manufacture, (in
The single phase controller rating may be less accordance with BS EN ISO 1461:1999).
than the full load current, as only the “U” phase Motors, aluminium self finish,or painted to motor
voltage is varied. manufacturers specification.
Many of the regulatable, three phase motors
may be offered for 2 speed applications by Deltal
Star (A/A) reconnection.
Impellers
JM Aerofoil impellers have a unique aerodynamic
section blade to optimise the efficiency of

6
JMAEROFOIL
n SPECIFICATION
Reversal of Airflow A further factor that must be considered in
assessing the life of the impeller is the quality of
Woods Air Movement has developed the JM the casting. Extensive testing of the alloys we
Aerofoil to give the optimum aerodynamic and use has established relationships between life,
acoustic performance. To optimise the perform operational stresses, and casting quality.
ance Woods Air Movement used the latest de Therefore to further ensure reliable operation of
sign software to establish the blade shape and our impellers all alloy impeller castings are
in particular the aerodynamic blade sections. assessed using x-ray against rigorous
The results of laboratory testing demonstrated acceptance criteria.
world class aerodynamic and acoustic perform
ance that is AMCA approved. Since the stresses experienced in the reverse
mode are generally higher than those in forward
As part of our commitment to fan engineering operation some impeller configurations are not
and total quality Woods Air Movement have es suitable for applications that require continuous
or regular reverse operation. Where this is the
(, tablished the operational limits of the impellers
case we have highlighted the fact on each
in all circumstances. Under laboratory conditions
relevant performance chart within this catalogue.
Woods Air Movement have tested JM impellers If these fans are required to be operated in
when run forwards, and in reverse. By measur reverse in other than cases of emergency, then
ing the stresses on the impellers under these each instance should be referred to Coichester
conditions, and relating these stresses to the for qualification or re-selection of impeller type.
properties of the alloys used for impeller con
struction, it is possible to determine the All other impeller configurations can be safely
maximum speed of the impeller for reliable life operated in reverse. Reversal is obtained by in
long operation. terchanging electrical connections.

Forms of Running Test Methods


The direction of airflow through the fan and the Testing
fan mounting position are defined as the “Form The air and sound performance data has been
of running”. measured by the latest version of British and
On each chart is shown the standard Form(s) of International Standards:
running for that particular fan, when mounted ISO 5801:1997 method for testing air
(. horizontally. Forvertical operation add suffix “U’
for airflow up, or suffix “D” for airflow down.
performance (dual numbered BS848 Ptl 1997).
BS848 Pt 2 1985, method of noise testing.
The standard Form of running offered will be it is essential, when comparing fan performances,
Form B. When an alternative is available: see that the same installation category and test
chart information, please request when the fan standards are used at all times.
is ordered. Form of running is especially relevant
when weatherproofed motors are required. Acoustic Data
Arrows indicating correct rotation and direction The sound levels quoted are based on tests
of airflow are incorporated in the duct nameplate. carried out under the Woods certified laboratory
conditions. Using the spectrum corrections stated
on each performance chart, an unweighted sound
power spectrum can be obtained for the fan.

FormA Form B Form AD Motor Ratings


The motor ratings, starting, full load currents
and speeds refer to the maximum output of
the motor. When the impeller does not require
the full output, the power and current will be less
FormAU FormBU Form BD than the maximum quoted.

7
JM AEROFOIL

QUALITY SYSTEMS C

ACCREDITED LA8OAATORY

WOODS LW cOuc.r,:S, ri,, LIOTTU)

TFITIO)Si’EU)E), I ITS I 511111 AIlOD 05000 I)MITI’I)

hi i, scrüly ,I,o,

AWM.Ten,TTT..dCo,Inh*m.bTh.IM.,,.IioTaI.ITL.

Ih h )qD(W)D ,&DIkJ,)

IS. 5Ill%;)) p.)S.I)d

I
Woods Air Movement Limited certifies that the JM Aerofoil shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on tests and procedures performed in
accordance with AMCA Publication 211 and comply with the requirements of the AMCA
Certified Ratings Program.

Quality Systems
Woods Air Movement Limited is committed to Quality Assurance. Registration to BS EN ISO 9001.94, means
that Woods design is quality assured as well as the manufacture. (,1

Our commitment to Quality Assurance doesn’t stop with the hardware. The performance data comes from
standard tests carried out in Woods own laboratory which is British Standard and AMCA accredited. Those fans
which are AMCA licensed for aerodynamic performance are identified by the AMCA Seal on the appropriate
characteristic curve(s).

A JM Aerofoil can be bought with the confidence as with all Woods products, that it will achieve the published
performance data and match the assured quality. All the Woods JM Aerofoils are fitted with P55 motors as
standard, and come with a 2 year ex works warranty.

All fans as detailed in this publication can be supplied for a one off emergency operation at temperatures up
to 200°C for 2 hours (H.T. Category 200/2). This facility is independently certified by the Loss Prevention
Certification Board (LPCB), Certificate number 386a Issue 2. Certain fans can be supplied for a one off
emergency operation at temperatures up to 400°C for 2 hours (H.T. Category 400/2 LPCB approved) Please
refer to Publication JM/HT for details. C

8
JM AEROFOIL
WOODS
AIR MOVEMENT
C’ HOW TO SPECIFY
Specifying The Fan Ordering The Fan
Having chosen the fan most suitable for your After identifying the best fan for your
individual application. application please order as follows:-
Please specify as follows:

1. The fan shall be manufactured by Woods 1. Fan type: JM Aerofoil Long cased (L-type),
Air Movement Limited model type JM or Short Cased (S-type) Form A or Form B.
Aerofoil long or short cased (L or S-type).
,

2. Motors, squirrel cage type, insulated to class 2. Fan Code:


F, bearings lubricated with wide temperature eg: 63JM/20!8/6/24
grease, keyed shaft. To comply with BS5000 where: 63 denotes the Fan impeller
Pt 99 and IEC 34-1. Weatherproof to 1P55. diameter in centimetres.
(Overheat protection provided on most JM denotes Fan Type.
single phase motors). /20 denotes impeller hub diameter
in centimetres.
3. Impellers, precision die cast aluminium /8 denotes a nominal 8 pole speed.
hub and clamp-plate, with equally spaced, /6 denotes the number of blades.
fully adjustable precision die cast Aerofoil /24 denotes the Pitch Angle for the
section blades. All rotating aluminium required duty.
components to be X-ray examined prior to
machining to assure quality of castings. 3. Quantity required.

4. Casings, either a long cased form complete 4. Duty required at standard air and
with an externally mounted pre-wired temperature e.g. 1 .60 3
m
/ s @ 50 Pa.
electrical terminal box, or short cased for
duct or plate installation. Casings are spun 5. Motor. eg: CT5
from sheet steel with integral pre-drilled
flanges, fully welded seams and hot-dipped 6. Electrical Supply:
galvanised after manufacture for excellent 220-240V/50 Hz! 1p
durability. 380-420 V / 50 Hz! 30

5. Mounting Arms, manufactured from mild 7. Ancillary items required.


steel hot dipped galvanised after
manufacture. Mounting Feet.
Impeller and Motor Side Guards.
6. Performance shall be independantly Silencers with or without pod.
approved by AMCA, and established in Speed Controller (electronic or auto-
accordance with 1SO5801 :1997 installation transformer) or 2 speed switch type
category D, method of testing air MDS3.10.
performance and BS848 Pt 2 1985 method Air Operated Dampers.
of noise testing. Matching Flanges
Beilmouth Inlets.
7. Ancillaries as required. Flexible Connectors.
Vibration Isolators.

9
JM AEROFOIL
GUIDE TO FAN SELECTION AIR MOVEMENT
C
SELECTION EXAMPLE -TOTAL PRESSURE
There are two principle methods of expressing 3. Selection on Individual Fan Charts
the pressure requirements, namely, F (Total) The data provided on each performance chart is
and SF (Static) pressure. The two types of pres- specifically for ducted Type D (ducted)
-

sure are related: installations for both long or short cased (S-type)
fans. Providing reasonable Type D conditions
F = SF
+
dF
= Fan Total pressure are maintained in installation of the fans, no
SF
= Fan Static pressure additional factors to volume flow or pressure
dF
= Fan Dynamic pressure need be incorporated for a suitable selection to
be made.
The international convention considers fan per
formance in terms of total pressure, but there is Plotthedutyontheselectedfanchartstoestablish
also established practice relating to the use of blade angle, sound level,absorbed power, motor
static pressure. For this reason Woods’ selec- size and rating, for the particular arrangement.
tion charts are laid out on a total pressure major
scale and include a secondary grid for static
pressure. The facility to display fan performance
Duty Point Required @ Standard Air (1.2
). 0.55 m
3
kglm
-

/s @ 100 Pa total pressure.


3
0
in terms of static pressure is necessary in order
to avoid total pressure fan selections being made Volume Flow = 0.55 m
/s
3
based on static pressure system requirements.
Fan Total Pressure = 100 Pa
The guide selections are made for either total or
static pressures of lOOPa. The resulting selec- Overall inlet Sound Power Level = 72 LW
tions are quite different and highlight the conse- (Interpolated from surrounding levels).
quences of selecting static pressure from charts
that only display performance in terms of total Pitch Angle required to achieve
pressure. Duty Point = 28°

Corrections to overall Sound Power level


Procedure Total Pressure
-
(F) for 28° Pitch Angle.
(Operating Point is Below shaded area)
1. Guide to Chart Numbers Frequency Hz
63 125 250 500 1K 2K 4K 8K
of Possible Selections Sound Power I
65 67 64 65 60 54 51 45 Lw
I
I
Level I Inlet I
The charts are arranged in order of fan diameter, Outlet 67 70 65 65 60 54 52 46 Lw
startingat3l5mm,uptol600mmdiameter,and
(N Absorbed Power @ Duty Point @ 28°
in order of fan speed for each diameter, .3,5,6,9
Pitch Angle = 0.09 kW.
& 12 bladed fan impellers as available.

NOTE: The chart numbers lead to a variety of Suitable Motor for fixed speed
fan sizes, impeller configurations and speeds. application,3 phase supply, from motor
The fan selected from the alternatives available schedules = BT4
will depend on the most critical factor for the Motor Data:
particular application Volume Flow and Pressure
-
Motor Rating (kW) = 0.15
required, Size, PowerConsumption, Sound Level Full Load (A) = 0.5
or First Cost. Starting Current (A) = 2.0

Speed Regulatable Versions


2. Required Duty If a speed regulatable version is required, (or
Establish the volume flow and total pressure DeltalStar(A/A) reconnect on 3 phase versions)
required of an individual fan at Standard Air (1 .2 the duty volume flow required should be multiplied
).
3
kg/rn by 1.05 prior to fan selection being made. (

10
JM AEROFOIL ] WOODS
Fan Code: 35JM/1 6/4/5/... I AIR MOVEMENT

355 mm 1420 rev/mm 5 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performanceshown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.
-

/min
3
ft 0 500 1000 1500 2000 2500
mm in
wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
16-
0.6

14 -

0.5
12

—. CU
I 0.4
1) 10
U)
Co
ci)
0
CU 8
C 0.3
C
CO
U-
6
a
0.2

0.1
2

0 -0.0

( cC)
C
a
a)
C
Co

a-

— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency Hz)
Angle
•%\
•• ••
4k Angle E 1k r
.9 -7 -5 -5 -13 -20 -27 -35 -6 5 4 5 -13 -20 -27 .35
8
-14 -10 7 -3 -10 -16 -22 -31 -12 -8 -7 -3 -9 -16 -20 -29
-12 -6 -6 -5 -13 -15 -21 -27 -10 -3 -6 5 -12 -14 -21 -27
16 16
-10 6 -7 -6 9 -12 -17 -24 .9 -3 -6 -6 -9 -12 17 -24

-_-
—\\t
2440 - - - - - -
-27
24-40
- - -
- I - - -

SK11689 04/03/99
JM AEROFOIL
GUIDE TO FAN SELECTION w
1
I ooi I AIR MOVEMENT
-

0
SELECTION EXAMPLE STATIC PRESSURE -

There are two principle methods of expressing 3 Selection on Individual Fan Charts
the pressure requirements, namely, F (Total) The data provided on each performance chart is
and (Static) pressure. The two types of pres specifically for ducted Type D (ducted)
-

sure are related: installations for both long or short cased (S-type)
fans. Providing reasonable Type D conditions
=
+ P P = Fan Total pressure are maintained in installation of the fans, no
Ps = Fan Static pressure additional factors to volume flow or pressure
dF
= Fan Dynamic pressure need be incorporated for a suitable selection to
be made.
The international convention considers fan per
formance in terms of total pressure, but there is Plotthe duty on the selected fan charts to establish
also established practice relating to the use of blade angle, sound level, absorbed power, motor
static pressure. For this reason Woods’ selec size and rating, for the particular arrangement.
tion charts are laid out on a total pressure major
scale and include a secondary grid for static
pressure. The facility to display fan performance
Duty Point Required @ Standard Air (1.2
kg/rn
)
3 . 0.55 m
-

/s @ 100 Pa static pressure.


3
C
in terms of static pressure is necessary in order
to avoid total pressure fan selections being made Volume Flow = 0.55 m
/s
3
based on static pressure system requirements.
Fan Static Pressure 100 Pa
The guide selections are made for either total or
static pressures of l0OPa. The resulting selec Overall inlet Sound Power Level = 74 L
tions are quite different and highlight the conse
quences of selecting static pressure from charts Pitch Angle required to achieve
that only display performance in terms of total Duty Point = 32°
pressure.
Corrections to overall Sound Power level
for 32° Pitch Angle.
Procedure Static Pressure (P
- J
5 (Operating Point is above shaded area):-
Frequency Hz
1. Guide to Chart Numbers
of Possible Selections
The charts are arranged in order of fan diameter,
starting at 315 mm, up to 1600mm diameter, and
in order of fan speed for each diameter, 3,5,6,9
L Sound Power
Level Inlet
Outlet
63 125 250 500 1K 2K 4K 8K
69 68 67 66 60 56 51 46Lw
71 69 67 67 61 57 53 48 Lw

Absorbed Power @ Duty Point @ 32°


Pitch Angle = 0.11 kW.
C)
& 12 bladed fan impellers as available.
Suitable Motor for fixed speed
NOTE: The chart numbers lead to a variety of application,3 phase supply, from motor
fan sizes, impeller configurations and speeds. schedules = BT4
The fan selected from the alternatives available
will depend on the most critical factor for the Motor Data:
particular application Volume Flow and Pressure
-
Motor Rating (kW) = 0.15
required, Size, Power Consumption, Sound Level Full Load (A) = 0.5
or First Cost. Starting Current (A) = 2.0

Speed Regulatable Versions


2. Required Duty If a speed regulatable version is required, (or
Establish the volume flow and static pressure Delta/Star(/A) reconnect on 3 phase versions)
required of an individual fan at Standard Air (1 .2 thedutyvolumeflow required should be multiplied
).
3
kg/m by 1 .05 prior to fan selection being made. C
12
JM AEROFOIL
Code: 35J Mu 6/4/5/...
WOODS AIR MOVEMENT
Fan
355 mm 1420 rev/mm 5 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.
-

/min
3
ft 0 500 1000 1500 2000 2500
I I mm in
I I I I I wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
16
0.6

14

0.5
12

(U
1 -0.4
6)
0
0
a)
0
(U 8-
0 - 0.3
H
C
(U

6
0

0.2

4-

0.1
2-

0- P0.0

I q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


‘•‘
Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 125 250 500 1k 2k 4k 8k Angle 63 125 250 500 1k 2k 4k 8k
-9 -7 -5 -5 -13 -20 -27 3 -6 -5 -4 -5 -13 -20 -27 -35
8
-14 -10 7 -3 -10 -16 -22 -31 -12 -8 -7 -3 -9 -16 -20 -29
-12 -6 -6 -5 -13 -15 -21 -27 -10 -3 -6 -5 -12 -14 -21 -27
16
-10 -6 -7 -6 -9 -12 -17 -24 -9 -3 -6 -6 9 -12 -17 -24
-5 -6 -7 -8 -14 -18 -23 -28 -5 -7 -7 -13 -17 -21 -26
24 40
-7 -5 -8 -7 -12 -16 -21 -27 -5 -2 -7 -7 -12 -26
-

16
-
O
2
j-

SK11689 04/03/99
C

C.

C
JM AEROFOIL
C Motor Frame Size Schedules
220—240 V / 50 Hz / 1 c Speed Regulation Details
Speed Pitch Pitch Speed Controller
Motor Full Load Starting Efficiency Power
Angle
Code Range Motor Rating Current Current Factor Capacitor Angle —

Auto-
Range Electronic
rev/mm (kW) (A) do.!. (A) % cos 0 l1
() Transformer
31JM/1616151... 900 16-40 BT5 0.04 0.5 0.7 44 0.91 2
22-40 BT5 0.04 0.5 0.7 44 0.91 2 22-40 ME1.1 MT1.1
31JM116/4/5/... 1420 12-36
24-38
BT5
BT5 .
0.07
0.07
0.6
0.6
1.8
1.8 g 24-38 ME1.1 MT1.1
31JM/16/2/5/... 2840 8-14 BT5 0.2 1.5 4 63 0.95 10
I 18-20 BT5 0.3 2.1 5 64 0.95 15
26-32 BT9 0.5 3.3 9 68 0.98 20
36-40 CT5 0.75 4.9 8.5 71 0.93 20

35JM/16/6/5/... 900 12-40 BT5 0.04 0.5 0.7 44 0.91 2 12-40 ME1.1 MT1.1
35JM/16/4/5/... 1420 8-22 BT5 0.07 0.6 1.8 60 0.92 4
16-24 BT5 0.07 0.6 1.8 60 0.92 4 16-24 ME1.1 MT1.1
28-40 BT4 0.13 1 2 58 0.95 6 28-40 MEl .1 MT1.1
35JM/16/2/5/... 2840 10-12 BT5 0.3 2.1 5 64 0.95 15
16-20 BT9 0.5 3.3 9 68 0.98 20
24-28 CT5 0.75 4.9 8.5 71 0.93 20
32-34 CT5 1 5.9 11.5 74 0.99 30
36-40 CT9 1.4 8.3 27 74 0.99 50
4OJM/16/6/5/... 900 8-28 BT5 0.04 0.5 0.7 44 0.91 2 8-28 ME1.1 MT1.1
32-40 BT5 0.09 0.8 1.6 50 0.95 5 32-40 ME1.1 MT1.1
40JM11614/51...’ 1420 10-12 BT5 0.07 0.6 1.8 60 0.92 4 10-12 ME1.1 MT1.1
18-24 BT4 0.13 1 2 58 0.95 6 18-24 ME1.1 MT1.1
26-28 BT5 0.16 1.2 2.7 62 0.95 5 26-28 ME1.3 MT1.5
30-36 BT5 0.23 1.6 2.7 64 0.95 8
34-40 BT9 0.25 1.7 3.8 66 0.97 10 34-40 ME1.3 MT1.5
4OJM/16/2/5/... 2840 10-10 BT9 0.5 3.3 9 68 0.98 20
14-16 CT5 0.75 4.9 8.5 71 0.93 20
20-22 CT5 1 5.9 11.5 74 0.99 30
24-28 CT9 1.4 8.3 27 74 0.99 50
45JM/161615/... 900 18-24 BT4 0.06 0.6 46 0.95 4 18-24 ME1.1 MT1.1
22-34 BT5 0.09 0.8 1.6 50 0.95 5 22-34 ME1.1 MT1.1
36-40 BT9 0.12 1.1 2.2 54 0.92 8 36-40 ME1.3 MT1.5
45JM/16/4/5/... 1420 10-14 BT4 0.13 1 2 58 0.95 6 10-14 ME1.1 MT1.1
18-18 BT5 0.16 1.2 2.7 62 0.95 5 18-18 ME1.3 MT1.5
22-22 BT5 0.2 1.5 2.7 62 0.95 8 22-22 ME1.3 MT1.5
24-26 BT9 0.25 1.7 3.8 66 0.97 10 24-26 ME1.3 MT1.5
24-30 BT9 0.3 2.1 5.3 65 0.95 10 24-30 ME1.3 MT1.5
36-40 CT5 0.45 2.9 7 68 0.99 15 36-40 ME1.3 MT1.5
45JM/16/2/5/... 2840 8-10 CT5 0.75 4.9 8.5 71 0.93 20
12-14 CT5 1 5.9 11.5 74 0.99 30
16-18 CT9 1.4 8.3 27 74 0.99 50

45JM/20/6/3/... 900 8-24 BT5 0.04 0.5 0.7 44 0.91 2 8-24 ME1.1 MT1.1
24-34 BT4 0.06 0.6 46 0.95 4 24-34 ME1.1 MT1.1
28-36 8T5 0.09 0.8 1.6 50 0.95 5 28-36 ME1.1 MT1 .1
45JM/201413/... 1420 10-12 BT5 0.07 0.6 1.8 60 0.92 4 10-12 ME1.1 MT1.1
16-22 BT4 0.13 1 2 58 0.95 6 16-22 ME1.1 MT1 .1
24-26 BT5 0.16 1.2 2.7 62 0.95 5 24-26 ME1.3 MT1.5
30-30 BT5 0.2 1.5 2.7 62 0.95 8 30-30 ME1.3 MT1.5
32-36 BT9 0.25 1.7 3.8 66 0.97 10 32-36 ME1.3 MT1 .5

45JM/20/2/3/... 2910 10-10 BT9 0.5 3.3 9 68 0.98 20


14-16 CT5 0.75 4.9 8.5 71 0.93 20
C 18-20
22-24
CT5
CT9
1
1.4
5.9
8.3
11.5
27
74
74
0.99
1 0.99
30
50
Although motors are rated 220/240 V electrical supply capacitors should be rated if x 450 V AC

15
JM AEROFOIL
Motor Frame Size Schedules a
220—240 V / 50 Hz / 1 0 Speed Regulation Details
Pitch
]
Speed Motor Full Load Starting Efficiency Power Pitch Speed Controller
Angle Capacitori Angle
Code Range Motor Rating Current Current Factor Range I Auto-
Electronic
rev/mm (0) (kW) (A) d.o.l. (A) % COS 0 l’ (°) Transformer
45JMI2O/6/6/... 900 16-24 BT4 0.06 0.6 46 0.95 4 16-24 ME1.1 MT1.1
22-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.1
34-40 BT9 0.12 1.1 2.2 54 0.92 8 34-40 ME1.3 MT1.5

45JM/20/4/6/... 1420 10-12 BT4 0.13 2 58 0.95 6 10-12 ME1.1 MT1.1


16-16 BT5 0.16 1.2 2.7 62 0.95 5 16-16 ME1.3 MT1.5
22-28 BT9 0.3 2.1 5.3 65 0.95 10 22-28 ME1.3 MT1.5
34-40 CT5 0.45 2.9 7 68 0.99 15 34-40 MEl .3 MT1 .5

45JM/20/2/6/... 2910 12-12 CT5 5.9 11.5 74 0.99 30


14-16 CT9 1.4 8.3 27 74 0.99 50

5OJM/16/6/5/... 915 16-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1.1
24-28
30-32
36-40
BT9
BT9
CT5
0.12
0.14
0.19
1.1
1.2
1.8
2.2
2.8
3
54
54
48
0.92
0.92
0.96
8
8
8
24-28
30-32
36-40
MEl .3
MEl .3
ME1.3
MT1 .5
MT1 .5
MT1.5
C,,
5OJM/1 6/4/5/... 1420 14-14 BT5 0.2 1.5 2.7 62 0.95 8 14-14 ME1.3 MT1.5
16-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
26-28 CT5 0.45 2.9 7 68 0.99 15 26-28 MEl .3 MT1 .5
32-34 CT5 0.55 3.7 9.5 65 0.99 25 32-34 ME1.6 MT1.5
38-40 CT9 0.68 4.2 11 76 0.96 25 38-40 ME1.6 MT1.5

5OJM/20/6/3/... 915 18-24 BT4 0.06 0.6 46 0.95 4 18-24 ME1.1 MT1.1
22-32 BT5 0.09 0.8 1.6 50 0.95 5 22-32 ME1.1 MT1.1
34-36 BT9 0.12 1.1 2.2 54 0.92 8 34-36 MEl .3 MT1 .5

5OJM/20/4/3/... 1420 12-14 BT4 0.13 2 58 0.95 6 12-14 ME1.1 MT1.1


16-18 8T5 0.16 1.2 2.7 62 0.95 5 16-18 ME1.3 MT1.5
24-30 BT9 0.3 2.1 5.3 65 0.95 10 24-3D MEl .3 MT1 .5
34-36 CT5 0.45 2.9 7 68 0.99 15 34-36 MEl .3 MT1 .5

5OJM/20/2/3/... 2910 12-12 CT5 1 5.9 11.5 74 0.99 30


14-16 CT9 1.4 8.3 27 74 0.99 50

5OJM/20/6/6/... 915 10-14 BT4 0.06 0.6 46 0.95 4 10-14 ME1.1 MT1.1
14-22 BT5 0.09 0.8 1.6 50 0.95 5 14-22 ME1.1 MT1.1
24-26 BT9 0.12 1.1 2.2 54 0.92 8 24-26 ME1.3 MT1.5
28-30 BT9 0.14 1.2 2.8 0.92 8 28-30 ME1.3 MT1.5
34-40 CT5 0.19 1.8 3 48 0.96 8 34-40 MEl .3 MT1 .5

5OJM/20/4/6/... 1420 14-16 BT9 0.25 1.7 3.8 66 0.97 10 14-16 ME1.3 MT1.5
16-20 I BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
24-26 CT5 0.45 2.9 7 68 0.99 15 24-26 ME1.3 MT1.5
30-32 CT5 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.5
36-38 CT9 0.68 4.2 11 76 0.96 25 36-38 ME1.6 MT1.5
38-40 CT9 0.97 6.2 19 72 0.95 40 38-40 MEl .12 MT1.8

56JM/1 6/6/5/... 900 8-14 BT5 0.09 0.8 1.6 50 0.95 5 8-14 ME1.1 MT1.1
20-22 BT9 0.14 1.2 2.8 54 0.92 I 8 20-22 ME1.3 MT1.5
24-28 CT5 0.19 1.8 3 48 0.96 8 24-28 ME1.3 MT1.5
32-34 CT5 0.24 2.1 4 51 0.98 12 32-34 MEl .3 MT1 .5
38-40 CT5 0.3 2.4 4 56 0.98 15 38-40 MEl .3 MT1 .5

56JM/16/4/5/... 1420 10-12 BT9 0.3 2.1 5.3 65 0.95 10 10-12 ME1.3 MT1.5
16-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1.5
22-22 CT5 0.55 3.7 9.5 65 0.99 25 22-22 ME1.6 MT1.5
24-26 CT9 0.7 5 15 64 0.96 40 24-26 MEl .6 MT1 .8
28-32 CT9 0.97 6.2 19 72 0.95 40 28-32 ME1.12 MT1.8
36-38 CT9 1.1 7.2 23 70 0.95 50 36-38 N/A MT1.12

56JM/20/6/3/... 900 12-16 BT4 0.06 0.6 46 0.95 4 12-16 ME1.1 MT1.1
16-22 BT5 0.09 0.8 1.6 50 0.95 5 16-22 ME1.1 MT1.1
24-28 8T9 0.12 1.1 2.2 54 0.92 8 24-28 ME1.3 MT1.5
30-30
34-36
BT9
CT5
0.14
0.19
1.2
1.8
2.8
3
54
48
0.92
0.96
8
8
30-30
34-36
ME1.3
MEl .3
MT1.5
MT1 .5 C.
Although motors are rated 220/240 V electrical supply capacitors should be rated t.tf x 450 V AC

16
JM AEROFOIL
WOODSAIR MOVEMENT
Motor Frame Size Schedules
220—240 V / 50 Hz / 1 0 Speed Regulation Details
Pitch
j
Speed Motor Full Load Starting Efficiency I Pitch Speed Controller
Angle Power
Code Range Motor Rating Current Current Factor Capacitor Angle Auto
Range Electronic

56JM/20/4131..i
rev/mm
1420
j (0)

14-14 BT5
(kW)
0.2
(A)
1.5
do.!. (A)
2.7 62
cos 0
0.95
lIt
8
J (0)

14-14 ME1.3
:TransformeH
MT1.5
16-20 BT9 0.3 2.1 5.3 65 0.95 10 16-20 ME1.3 MT1.5
26-28 CT5 0.45 2.9 7 68 0.99 15 26-28 ME1.3 MT1.5
30-32 Cm 0.55 3.7 9.5 65 0.99 25 30-32 ME1.6 MT1.5
34-36 CT9 0.68 4.2 11 76 0.96 25 34-36 ME1.6 MT1.5
56JM/20/2/3/... 2910 14-18 F2225 2.7 14 50 84 0.98 90

56JM/20/6/6/... 900 8-12 BT5 0.09 0.8 1.6 50 0.95 5 8-12 ME1.1 MT1.l
16-18 BT9 0.12 1.1 2.2 54 0.92 8 16-18 ME1.3 MT1.5
20-20 BT9 0.14 1.2 2.8 54 0.92 8 20-20 ME1.3 MT1.5
24-26 CT5 0.19 1.8 3 48 0.96 8 24-26 ME1.3 MT1.5
30-32 CT5 0.24 2.1 4 51 0.98 12 30-32 ME1.3 MT1.5
36-38 CT5 0.3 2.4 4 56 0.98 15 36-38 ME1.3 MT1.5
56JM/20/4/6/... 1420 10-10 BT9 0.3 2.1 5.3 65 0.95 10 10-10 ME1.3 MT1.5
16-18 CT5 0.45 2.9 7 68 0.99 15 16-18 ME1.3 MT1.5
20-20 CT5 0.55 3.7 9.5 65 0.99 25 20-20 ME1.6 MT1.5
22-26 CT9 0.7 5 15 64 0.96 40 22-26 ME1.6 MT1.8
26-30 CT9 0.97 6.2 19 72 0.95 40 26-30 M El. 12 MT1 .8
34-36 CT9 1.1 7.2 23 70 0.95 50 34-36 N/A MT1 .12
63JM/2016/31... 900 8-10 BT5 0.09 0.8 1.6 50 0.95 5 8-10 ME1.l MT1 .1
12-14 BT9 0.12 1.1 2.2 54 0.92 8 12-14 ME1.3 MT1.5
16-16 BT9 0.14 1.2 2.8 54 0.92 8 16-16 ME1.3 MT1.5
20-22 CT5 0.19 1.8 3 48 0.96 8 20-22 ME1.3 MT1.5
26-26 CT5 0.24 2.1 4 51 0.98 12 26-26 ME1.3 MT1 .5
30-32 CT5 0.3 2.4 4 56 0.98 15 30-32 ME1.3 MT1.5
63JM/20/4/3/... 1420 14-14 CT5 0.45 2.9 7 68 0.99 15 14-14 ME1.3 MT1.5
20-20 CT9 0.68 4.2 11 76 0.96 25 20-20 ME1.6 MT1.5
20-22 CT9 0.7 5 15 64 0.96 40 20-22 ME1.6 MT1.8
22-26 CT9 0.97 6.2 19 72 0.95 40 22-26 ME1.12 MT1.8
28-30 CT9 1.1 7.2 23 70 0.95 50 28-30 N/A MT1.12
63JM120/6/61... 900 12-14 CT5 0.19 1.8 3 48 0.96 8 12-14 ME1.3 MT1.5
18-18 CT5 0.24 2.1 4 51 0.98 12 18-18 ME1.3 MT1.5
22-22 CT5 0.3 2.4 4 56 0.98 15 22-22 ME1.3 MT1.5
28-30 CT9 0.43 3.3 7.5 59 0.96 15 28-30 ME1.6 MT1.5
34-34 CT9 0.52 4 9.2 59 0.95 20 34-34 ME1.6 MT1.8
63JM/20/4/6/... 1420 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1.8
14-16 CT9 0.97 6.2 19 72 0.95 40 14-16 MEl .12 MT1 .8
20-22 CT9 1.1 7.2 23 70 0.95 50 20-22 N/A MT1 .12
71 JMI2O/6131... 900 12-12 CT5 0.19 1.8 3 48 0.96 8 12-12 ME1.3 MT1.5
16-18 CT5 0.24 2.1 4 51 0.98 12 16-18 ME1.3 MT1 .5
20-22 CT5 0.3 2.4 4 56 0.98 15 20-22 ME1.3 MT1.5
26-28 CT9 0.43 3.3 7.5 59 0.96 15 26-28 ME1.6 MT1.5
32-32 CT9 0.52 4 9.2 59 0.95 20 32-32 ME1.6 MT1.8
71 JM/20/4/3/... 1440 12-12 CT9 0.7 5 15 64 0.96 40 12-12 ME1.6 MT1 .8
14-16 CT9 0.97 6.2 19 72 0.95 40 14-16 ME1.12 MT1 .8
20-20 CT9 1.1 7.2 23 70 0.95 50 20-20 N/A MT1.12
71JM/20/6/6/... 900 12-12 CT5 0.3 2.4 4 56 0.98 15 12-12 ME1.3 MT1.5
18-18 CT9 0.43 3.3 7.5 59 0.96 15 18-18 ME1.6 MT1.5
22-22 CT9 0.52 4 9.2 59 0.95 20 22-22 ME1.6 MT1.8
8OJM/20/6/3/... 935 14-14 CT5 0.3 2.4 4 56 0.98 15 14-14 ME1.3 MT1 .5
18-20 CT9 0.43 3.3 7.5 59 0.96 15 18-20 ME1.6 I MT1.5

C
Although motors are rated 220/240 V electrical supply capacitors should be rated l.tf x 450 V AC

17
JM AEROFOIL
Motor Frame Size Schedules C’
380-420 V / 50 Hz / 3 0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
Range Electronic Auto-
rev/mm Angle (0)
(kW) (A) d.o.l. (A) % COS 0 (0)
jTransformer
31JM/16/615/... 900 40 BT4 0.06 0.3 0.8 46 0.6 NR at t is angle

31 JM/1 6/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 34-40 ME3.2D MT3.0.5

31 JM/1 6/2/5/... 2840 24 BT5 0.35 0.9 3.6 66 0.85


36 BT9 0.58 1.4 6 71 0.85
40 CT5 0.95 2 9.5 75 0.9

35JM/16/6/5/... 900 40 BT4 0.06 0.3 0.8 46 0.6 28-40 ME3.2D MT3.0.5

35JM/1 6/4/5/... 1420 40 BT4 0.13 0.5 1.8 58 0.7 22-40 ME3.2D MT3.0.5

35JM/1 6/2/5/... 2840 14


22
34
BT5
BT9
CT5
0.35
0.58
0.95
0.9
1.4
2
3.6
6
9.5
66
71
75
0.85
0.85
0.9
C.
40 CT9 1.7 3.5 20 78 0.9

4OJM/1 6/6/5/... 900 38 BT4 0.06 0.3 0.8 46 0.6 18-38 ME3.2D MT3.0.5
40 BT5 0.09 0.5 1.2 50 0.58 36-40 ME3.2D MT3.0.5

4OJM/16/4/5/... 1420 24 BT4 0.13 0.5 1.8 58 0.7 14-24 ME3.2D MT3.0.5
34 BT5 0.2 0.7 2.4 62 0.7 26-34 ME3.2D MT3.1
40 BT9 0.3 0.9 4.6 65 0.75 36-40 ME3.2D MT3.1

4OJM/1 6/2/5/... 2840 12 BT9 0.58 1.4 6 71 0.85


20 CT5 0.95 2 9.5 75 0.9
32 CT9 1.7 3.5 20 78 0.9

45JM/1 6/6/5/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
28 BT4 0.08 0.4 50 0.6
34 BT5 0.09 0.5 1.2 50 0.58 26-34 ME3.2D MT3.0.5
38 8T5 0.12 0.5 1.2 54 0.7
40 BT9 0.14 0.6 1.8 54 0.66 36-40 ME3.2D MT3.1

45JM/1 6/4/5/... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.2D MT3.0.5
22 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.1
30
36
40
BT9
BT9
CT5
0.3
0.39
0.58
0.9
1.1
1.7
4.6
4.6
6.5
65
67
67
0.75
0.75
0.74
24-30

40-40
ME3.2D

ME3.2D
MT3.1

MT3.2
C
45JM/1 6/2/5/... 2840 12 CT5 0.95 2 9.5 75 0.9
20 CT9 1.7 3.5 20 78 0.9

45JM/20/6/3/... 900 34 BT4 0.06 0.3 0.8 46 0.6 16-34 ME3.2D MT3.0.5
36 BT5 0.09 0.5 1.2 50 0.58 32-36 ME3.2D MT3.0.5

45JM/20/4/3/... 1420 22 BT4 0.13 0.5 1.8 58 0.7 12-22 ME3.2D MT3.0.5
30 BT5 0.2 0.7 2.4 62 0.7 22-30 ME3.2D MT3.1
36 BT9 0.3 0.9 4.6 65 0.75 32-36 ME3.2D MT3.1

45JM/20/2/3/... 2910 12 BT9 0.58 1.4 6 71 0.85


18 CT5 0.95 2 9.5 75 0.9
28 CT9 1.7 3.5 20 78 0.9
36 F2225 3.8 7.1 44 84 0.92

45JM/20/6/6/... 900 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
32 BT5 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.5
36 BT5 0.12 0.5 1.2 54 0.7
40 BT9 0.14 0.6 1.8 54 0.66 34-40 ME3.2D MT3.1

C
18
JM AEROFOIL
Motor Frame Size Schedules
380—420 V / 50 Hz / 3 0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Staing Efficiency Power Pitch Speed Controller
Code ! Motor Rating Current Current Factor Angle
%
i
Range Electronic Auto-
rev/mm Angle () (kW) (A) do.!. (A) cos Transformer
45JM/2014161... 1420

12
20
BT4
BT5
0.13
0.2
0.5
0.7
1.8
2.4
58
62
0.7
0.7
8-12
I 14-20
ME3.2D
ME3.2D
MT3.0.5 1
MT3.1
28 BT9 0.3 0.9 4.6 65 0.75 22-28 ME3.2D MT3.1
34 BT9 0.39 1.1 4.6 67 0.75
40 CT5 0.58 1.7 6.5 67 0.74 38-40 ME3.2D MT3.2
45JM/20/2161... 2910 12 CT5 0.95 2 9.5 75 0.9
20 CT9 1.7 3.5 20 78 0.9
34 F2225 3.8 7.1 44 84 0.92
40 F2229 6.2 11 90 86 0.92

5OJM/16/6/5/... 915 16 BT4 0.06 0.3 0.8 46 0.6 8-16 ME3.2D MT3.0.5
C’ 22
26
32
BT5
BT5
BT9
0.09
0.12
0.14
0.5
0.5
1.2
1.2
50
54
0.58
0.7
18-22 ME3.2D MT3.0.5

0.6 1.8 54 0.66 24-32 ME3.2D MT3.1


36 BT9 0.19 0.7 1.8 59 0.66
40 CT5 0.22 0.8 2.5 55 0.7 36-40 ME3.2D MT3.1

5OJM/1 6/4/5/... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
34 CT5 0.58 1.7 6.5 67 0.74 28-34 ME3.2D MT3.2
38 CT5 0.71 1.9 6.5 71 0.75
40 CT9 0.9 2.3 9 72 0.78 36-40 ME3.2D MT3.2

5OJM/20/6/3/... 915 24 BT4 0.06 0.3 0.8 46 0.6 10-24 ME3.2D MT3.0.5
32 BT5 0.09 0.5 1.2 50 0.58 26-32 ME3.2D MT3.0.5
36 BT9 0.14 0.6 1.8 54 0.66 34-36 ME3.2D MT3.1
5OJM/20/4/3/... 1420 14 BT4 0.13 0.5 1.8 58 0.7 8-14 ME3.2D MT3.0.5
22 BT5 0.2 0.7 2.4 62 0.7 16-22 ME3.2D MT3.1
30 BT9 0.3 0.9 4.6 65 0.75 24-30 ME3.2D MT3.1
36 CT5 0.58 1.7 6.5 67 0.74 36-36 ME3.2D MT3.2

5OJM/20/2131... 2910 12 CT5 0.95 2 9.5 75 0.9


20 CT9 1.7 3.5 20 78 0.9
34 F2225 3.8 7.1 44 84 0.92
36 F2229 6.2 11 90 86 0.92

5OJM/20/6/6/... 915 14 BT4 0.06 0.3 0.8 46 0.6 8-14 ME3.2D MT3.0.5
22 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.5
30 BT9 0.14 0.6 1.8 54 0.66 24-30 ME3.2D MT3.1
34 8T9 0.19 0.7 1.8 59 0.66
40 CT5 0.22 0.8 2.5 55 0.7 34-40 ME3.2D MT3.1

5OJM/20/4/6/... 1420 12 BT5 0.2 0.7 2.4 62 0.7 10-12 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
32 CT5 0.58 1.7 6.5 67 0.74 26-32 ME3.2D MT3.2
36 CT5 0.71 1.9 6.5 71 0.75
40 CT9 0.9 2.3 9 72 0.78 34-40 ME3.2D MT3.2
5OJM/20/2/6/... 2910 12 CT9 1.7 3.5 20 78 0.9
24 F2225 3.8 7.1 44 84 0.92
34 F2229 6.2 11 90 86 0.92

56JM/1 6/8/5/.. 680 24 BT5 0.065 0.5 0.8 34 0.57 20-24 ME3.5S MT3.0.5
32 BT9 0.09 0.5 0.9 42 0.57 26-32 ME3.2D MT3.1
40 CT5 0.13 0.7 1.5 47 0.6 34-40 ME3.2D MT3.1

19
JMAEROFOIL
woos’
AIR MOVEMENT

Motor Frame Size Schedules


380-420 V I 50 Hz / 3______ Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
Range Electronic Auto
rev/mm Angle (0)
(kW) (A) d.o.l. (A) % cos 0 Transformer
56JM/16/6/5/... 900 10 BT4 0.08 0.4 1 50 0.6
14 BT5 0.09 0.5 1.2 50 0.58 10-14 ME3.2D MT3.0.5
22 BT9 0.14 0.6 1.8 54 0.66 16-22 ME3.2D MT3.1
32 CT5 0.22 0.8 2.5 55 0.7 24-32 ME3.2D MT3.1
40 CT5 0.3 1.1 3.3 56 0.7 34-40 ME3.2D MT3.2

56JM/16/4/5/... 1420 12 BT9 0.3 0.9 4.6 65 0.75 10-12 ME3.2D MT3.1
24 CT5 0.58 1.7 6.5 67 0.74 18-24 ME3.2D MT3.2
26 CT5 0.71 1.9 6.5 71 0.75
32 CT9 0.9 2.3 9 72 0.78 26-32 ME3.2D MT3.2
40 CT9 1.15 3 14 71 0.78 34-40 ME3.2D N/A

56JM/20/6/3/... 900 16 BT4 0.06 0.3 0.8 46 0.6 8-16 ME3.2D MT3.0.5
22 BT5 0.09 0.5 1.2 50 0.58 18-22 ME3.2D MT3.0.5
30 BT9 0.14 0.6 1.8 54 0.66 24-30 ME3.2D MT3.1
34 BT9 0.19 0.7 1.8 59 0.66
36 CT5 0.22 0.8 2.5 55 0.7 34-36 ME3.2D MT3.1

56JM/201413/... 1420 14 BT5 0.2 0.7 2.4 62 0.7 10-14 ME3.2D MT3.1
20 BT9 0.3 0.9 4.6 65 0.75 16-20 ME3.2D MT3.1
24 BT9 0.39 1.1 4.6 67 0.75
32 CT5 0.58 1.7 6.5 67 0.74 28-32 ME3.2D MT3.2
34 CT5 0.71 1.9 6.5 71 0.75
36 CT9 0.9 2.3 9 72 0.78 34-36 ME3.2D MT3.2

56JM120/2131... 2910 12 CT9 1.7 3.5 20 78 0.9


24 F2225 3.8 7.1 44 84 0.92
34 F2229 6.2 11 90 86 0.92

56JM/20/6/6/... 900 12 BT5 0.09 0.5 1.2 50 0.58 10-12 ME3.2D MT3.0.5
20 BT9 0.14 0.6 1.8 54 0.66 16-20 ME3.2D MT3.1
24 BT9 0.19 0.7 1.8 59 0.66
30 CT5 0.22 0.8 2.5 55 0.7 24-30 ME3.2D MT3.1
38 CT5 0.3 1.1 3.3 56 0.7 32-38 ME3.2D MT3.2
40 CT9 0.4 1.5 5.3 66 0.6 40-40 ME3.2D MT3.2

56JM/20/4/6/... 1420 10 BT9 0.3 0.9 4.6 65 0.75 10-10 ME3.2D MT3.1
14 BT9 0.39 1.1 4.6 67 0.75
22 CT5 0.58 1.7 6.5 67 0.74 18-22 ME3.2D MT3.2
24 CT5 0.71 1.9 6.5 71 0.75
30 CT9 0.9 2.3 9 72 0.78 24-30 ME3.2D MT3.2
36 CT9 1.15 3 14 71 0.78 32-36 ME3.2D N/A
40 CT9 1.4 3.5 14 74 0.77

56JM/20/2/6/... 2910 14 F2225 3.8 7.1 44 84 0.92


24 F2229 6.2 11 90 86 0.92

63JM120/8131... 680 18 BT5 0.065 0.5 0.8 34 0.57 16-18 ME3.5S MT3.0.5
24 BT9 0.09 0.5 0.9 42 0.57 20-24 ME3.2D MT3.1
32 CT5 0.13 0.7 1.5 47 0.6 26-32 ME3.2D MT3.1
36 CT9 0.18 0.7 1.7 56 0.66 34-36 ME3.2D MT3.1

63JM/20/6/3/... 900 10 BT5 0.09 0.5 1.2 50 0.58 8-10 ME3.2D MT3.0.5
16 BT9 0.14 0.6 1.8 54 0.66 12-16 ME3.2D MT3.1
20 BT9 0.19 0.7 1.8 59 0.66
26 CT5 0.22 0.8 2.5 55 0.7 20-26 ME3.2D MT3.1
32 CT5 0.3 1.1 3.3 56 0.7 28-32 ME3.2D MT3.2
36 CT9 0.4 1.5 5.3 66 0.6 34-36 ME3.2D MT3.2

C
20
JM AEROFOIL
WOODI MR MOVEMENT

Motor Frame Size Schedules


380-420 V I 50 Hz I 3 0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
rev/mm Angle (0)
(kW) (A) d.o.l.(A) % cosø (0)

Range Electronic Auto
Transtormejj
63JM12014/3/... 1420 18 CT5 0.58 1.7 6.5 67 0.74 14-18 ME3.2D MT3.2
20 CT5 0.71 1.9 6.5 71 0.75
26 CT9 0.9 2.3 9 72 0.78 20-26 ME3.2D MT3.2
30 CT9 1.15 3 14 71 0.78 28-30 ME3.2D N/A
34 CT9 1.4 3.5 14 74 0.77

63JM12018/6/... 680 10 BT5 0.065 0.5 0.8 34 0.57 10-10 ME3.55 MT3.0.5
16 BT9 0.09 0.5 0.9 42 0.57 14-16 ME3.2D MT3.1
22 CT5 0.13 0.7 1.5 47 0.6 18-22 ME3.2D MT3.1
36 CT9 0.25 1.2 2.6 50 0.6 32-36 ME3.2D MT3.2

63JM/20/6/6/... 900 8 BT9 0.14 0.6 1.8 54 0.66 8- 8 ME3.2D MT3.1


22 CT5 0.3 1.1 3.3 56 0.7 20-22 ME3.2D MT3.2
34 CT9 0.52 1.7 7.5 59 0.74 30-34 ME3.2D MT3.2
36 CT9 0.68 2.2 7.5 60 0.73

63JM/20/4/6/... 1420 10 CT5 0.58 1.7 6.5 67 0.74 10-10 ME3.2D MT3.2
12 CT5 0.71 1.9 6.5 71 0.75
18 CT9 0.9 2.3 9 72 0.78 14-18 ME3.2D MT3.2
22 CT9 1.15 3 14 71 0.78 20-22 ME3.2D N/A
I 24 CT9 1.4 3.5 14 74 0.77
32 F2245 2.1 4.7 30 79 0.82 28-32 N/A N/A
F2245 2.7 5.8 30 81 0.83
36
63JM/25/2J3/... 2910 16 F2225 3.8 7.1 44 84 0.92
22 F2229 6.2 11 90 86 0.92
28 0132/19 8.5 15.9 111 88 0.88
32 D132/22 11 20.3 137 88 0.89

63JM125/4/6/... 1440 36 F2245 2.1 4.7 30 79 0.82 32-36 N/A N/A


36 F2245 2.7 5.8 30 81 0.83

63JM/25/2/61... 2910 8 F2225 3.8 7.1 44 84 0.92


14 F2229 6.2 11 90 86 0.92
20 0132/19 8.5 15.9 111 88 0.88
24 0132/22 11 20.3 137 88 0.89
28 D160/18 13 25 150 88 0.85
34 D160/23 17.5 33 198 89 0.86
36 D160/28 22 40.5 243 89 0.88

63JM/25/619/... 935 40 F2265 1.55 4 15 75 0.75

63JM125/4191... 1440 30 F2245 2.1 4.7 30 79 0.82 26-30 N/A N/A


36 F2245 2.7 5.8 30 81 0.83
40 F2249 4.4 9.3 52 83 0.83

63JM/251219/... 2910 10 F2229 6.2 11 90 86 0.92


16 01321191 8.5 15.9 111 88 0.88
20 . 01321221 11 20.3 137 88 0.89
28 D160/23 17.5 33 198 89 0.86
34 0160/28 22 40.5 243 89 0.88
40 D160/32 27 49.5 334 89 0.88

71JM/2018/3/... 680 22 CT5 0.13 0.7 1.5 47 0.6 18-22 ME3.2D MT3.1
. 36 CT9 0.25 1.2 2.6 50 0.6 30-36 ME3.2D MT3.2

71JM/20/6/3/... 900 22 CT5 0.3 1.1 3.3 56 0.7 18-22 ME3.2D MT3.2
32 CT9 0.52 1.7 7.5 59 0.74 28-32 ME3.2D MT3.2
34 CT9 0.68 2.2 7.5 60 0.73
36 F2265 1.55 4 15 75 0.75

21
JM AEROFOIL
Motor Frame Size Schedules C
380—420 V I 50 Hz / 3 0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Pitch Speed Controller
Power
Code Motor Rating Current Current Factor Angle
Range Electronic Auto-
rev/mm AngIe (°) (kW) (A) d.o.l. (A) % cos Transformer
71 JM/20/4/3/... 1440 10 CT5 0.71 1.9 6.5 71 0.75
16 CT9 0.9 2.3 9 72 0.78 12-16 ME3.2D MT3.2
20 CT9 1.15 3 14 71 0.78 18-20 ME3.2D N/A
22 CT9 1.4 3.5 14 74 0.77
30 F2245 2.1 4.7 30 79 0.82 28-30 N/A N/A
36 F2245 2.7 5.8 30 81 0.83

71JM/20/8/6/... 680 12 CT5 0.13 0.7 1.5 47 0.6 10-12 ME3.2D MT3.1
24 CT9 0.25 1.2 2.6 50 0.6 20-24 ME3.2D MT3.2
36 F2265 0.65 2.4 8 63 0.62 36-36 ME3.2D N/A

71JM/20/6/6/... 900 12 CT5 0.3 1.1 3.3 56 0.7 12-12 ME3.2D MT3.2
22 CT9 0.52 1.7 7.5 59 0.74 20-22 ME3.2D MT3.2
24
36
CT9
F2265
0.68
1.55
2.2
4
7.5
15
60
75
0.73
0.75
C
71 JM/20/4/6/... 1440 12 CT9 1.15 3 14 71 0.78 12-12 ME3.2D N/A
20 F2245 2.1 4.7 30 79 0.82 18-20 N/A N/A
24 F2245 2.7 5.8 30 81 0.83
36 F2249 4.4 9.3 52 83 0.83

71 JM/25/4/3/... 1440 32 F2245 2.1 4.7 30 79 0.82 32-32 N/A N/A

71 JM/25/8/6/... 695 36 F2265 0.4 1.5 5 63 0.61 30-36 ME3.2D MT3.2

71 JM/25/6/6/... 935 36 F2265 1.55 4 15 75 0.75

71 JM/25/4/6/... 1440 24 F2245 2.1 4.7 30 79 0.82 22-24 N/A N/A


28 F2245 2.7 5.8 30 81 0.83
36 F2249 4.4 9.3 52 83 0.83

71 JM/25/8/9/... 695 36 F2265 0.65 2.4 8 63 0.62 34-36 ME3.2D N/A

71 JM/25/6/9/... 935 36 F2265 1.35 3.6 15 73 0.74 34-36 N/A N/A

71 JM125/419/... 1440 18 F2245 2.1 4.7 30 79 0.82 16-18 N/A N/A


22 F2245 2.7 5.8 30 81 0.83
34 F2249 4.4 9.3 52 83 0.83
36 Dl 32/18 6.3 12.8 85 86 0.83

71JM/31/2/9/... 2910 10 Dl 32/22 11 20.3 137 88 0.89


12 0160/18 13 25 150 88 0.85
18 0160/23 17.5 33 198 89 0.86
22 Dl 60/28 22 40.5 243 89 0.88
26 0160/32 27 49.5 334 89 0.88
32 0180/34 34 64 402 89 0.86
38 0180/40 40 74.5 468 90 0.86

8OJM/20/8/3/... 695 14 CT5 0.13 0.7 1.5 47 0.6 12-14 ME3.2D MT3.1
20 CT9 0.18 0.7 1.7 56 0.66 16-20 ME3.2D MT3.1
24 CT9 0.25 1.2 2.6 50 0.6 22-24 ME3.2D MT3.2
36 F2265 0.65 2.4 8 63 0.62 36-36 ME3.2D N/A

8OJM/20/6/3/... 935 14 CT5 0.3 1.1 3.3 56 0.7 12-14 ME3.2D MT3.2
22 CT9 0.52 1.7 7.5 59 0.74 20-22 ME3.2D MT3.2
24 CT9 0.68 2.2 7.5 60 0.73
36 F2265 1.35 3.6 15 73 0.74 36-36 N/A N/A

8OJM/20/4/3/... 1440 12 CT9 1.15 3 14 71 0.78 12-12 ME3.2D N/A


14 CT9 1.4 3.5 14 74 0.77
22 F2245 2.1 4.7 30 79 0.82 20-22 N/A N/A
24
36
F2245
F2249
2.7
4.4
5.8
9.3
30
52
81
83
0.83
0.83 C
22
JM AEROFOIL
Motor Frame Size Schedules
380—420 V / 50 Hz 3 i”
0 Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency
: Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
% Range Electronic Auto
rev/mm Angle (0)
(kW) (A) d.o.l. (A) COS 0 (0)
Transformer
8OJM/20/8/6/... 695 16 CT9 0.25 1.2 2.6 50 0.6 14-16 ME3.2D MT3.2
32 F2265 0.65 2.4 8 63 0.62 24-32 ME3.2D N/A
36 F2265 0.8 2.8 8 65 0.63

8OJM/20/6/6/... 935 12 CT9 0.52 1.7 7.5 59 0.74 12-12 ME3.2D MT3.2
14 CT9 0.68 2.2 7.5 60 0.73
28 F2265 1.35 3.6 15 73 0.74 24-28 N/A N/A
30 F2265 1.55 4 15 75 0.75
36 F2269 2.1 5.5 26 74 0.74 36-36 N/A N/A

8OJM/20/4/6/... 1440 12 F2245 2.1 4.7 30 79 0.82 12-12 N/A N/A


14 F2245 2.7 5.8 30 81 0.83

C 80JM/25/8/3/... 695
24

32
F2249

F2265
4.4

0.4
9.3

1.5
52

5
83

63
0.83

0.61 30-32 ME3.2D MT3.2

80JM/25/6/3/... 935 32 i F2265 1.55 4 15 75 0.75

8OJM/25/4/3/... 1440 26 F2245 2.1 4.7 30 79 0.82 22-26 N/A N/A


28 F2245 2.7 5.8 30 81 0.83
32 F2249 4.4 9.3 52 83 0.83

8OJM/25/8/6/... 695 36 F2265 0.65 2.4 8 63 0.62 28-36 ME3.2D N/A


36 F2265 0.8 2.8 8 65 0.63

8OJM/25/6/6/... 935 32 F2265 1.35 3.6 15 73 0.74 28-32 N/A N/A


34 F2265 1.55 4 15 75 0.75
36 F2269 2.5 6.3 26 76 0.75
8OJM/25/4/6/... 1440 16 F2245 2.1 4.7 30 79 0.82 14-16 N/A N/A
20 F2245 2.7 5.8 30 81 0.83
28 F2249 4.4 9.3 52 83 0.83
34 0132/18 6.3 12.8 85 86 0.83

8OJM/25/8/9/... 695 30 F2265 0.65 2.4 8 63 0.62 22-30 ME3.2D N/A


36 F2269 0.85. 3 11 64 0.64 32-36 ME3.2D N/A

8OJM/25/6/9/... 935 26 F2265 1.35 3.6 15 73 0.74 22-26 N/A N/A


36 F2269 2.1 5.5 26 74 0.74 32-36 N/A N/A

8OJM/25/4/9/... 1440 12 F2245 2.7 5.8 30 81 0.83


22 F2249 4.4 9.3 52 83 0.83
28 0132/18 6.3 12.8 85 86 0.83
36 0132/24 9 18.3 127 87 0.82

8OJM/31 /2/9/... 2910 10 0160/23 17.5 33 198 89 0.86


12 0160/28 22 40.5 243 89 0.88
16 0160/32 27 49.5 334 89 0.88
20 0180/34 34 64 402 89 0.86
22 0180/40 40 74.5 468 90 0.86

9OJM/25/8/3/... 695 32 F2265 0.65 2.4 8 63 0.62 28-32 ME3.20 N/A

9OJM/25/6/3/... 935 32 F2265 1.35 3.6 15 73 0.74 28-32 N/A N/A

9OJM/25/4/3/... 1440 16 F2245 2.1 4.7 30 79 0.82 16-16 N/A N/A


20 F2245 2.7 5.8 30 81 0.83
28 F2249 4.4 9.3 52 83 0.83
32 0132/18 6.3 12.8 85 86 0.83

9OJM/25/8/6/... 695 26 F2265 0.65 2.4 8 63 0.62 20-26 ME3.2D N/A


28 F2265 0.8 2.8 8 65 0.63
32 F2269 0.85 3 11 64 0.64 28-32 ME3.2D N/A

23
JM AEROFOIL
Motor Frame Size Schedules C
380—420 V / 50 Hz / 3 (P Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle I
Range Electronic Auto-
rev/mm Angle (°) (kW) (A) d.o.l. (A) % COS 0 Transformer
9OJM/25/6/6/... 935 22 F2265 1.35 3.6 15 73 0.74 20-22 N/A N/A
24 F2265 1.55 4 15 75 0.75
32 F2269 2.1 5.5 26 74 0.74 30-32 N/A N/A

9OJM/25/4/6/... 1440 10 F2245 2.7 5.8 30 81 0.83


18 F2249 4.4 9.3 52 83 0.83
I 24 0132/18 6.3 12.8 85 86 0.83
32 0132/24 9 18.3 127 87 0.82

9OJM/25/8/9/... 695 18 F2265 0.65 2.4 8 63 0.62 14-18 ME3.2D N/A


20 F2265 0.8 2.8 8 65 0.63
24 F2269 0.85 3 11 64 0.64 20-24 ME3.2D N/A
30 F2269 1.1 4.7 14 64 0.54 26-30 N/A N/A
34 F2269 1.4 5.1 14 65 0.61 (
36 0132/19 3 7.7 33 80 0.71

9OJM/25/6/9/... 935 16 F2265 1.35 3.6 15 73 0.74 14-16 N/A N/A


16 F2265 1.55 4 15 75 0.75
24 F2269 2.1 5.5 26 74 0.74 22-24 N/A N/A
24 F2269 2.5 6.3 26 76 0.75
36 Dl 32/19 4.5 9.6 55 84 0.81

9OJM/25/4/9/... 1440 12 i F2249 4.4 52 83 0.83


I 16 0132/18 6.3 12.8 85 86 0.83
24 I 0132/24 9 18.3 127 87 0.82
32 0160/20 13 26 140 87 0.82
36 Dl 60/26 17 33 185 88 0.85

100JM/25/8/3/... 695 26 F2265 0.65 2.4 8 63 0.62 20-26 ME3.2D N/A


30 F2265 0.8 2.8 8 65 0.63
32 F2269 0.85 3 11 64 0.64 28-32 ME3.2D N/A

100JM/25/6/3/... 935 24 F2265 1.35 3.6 15 73 0.74 20-24 N/A N/A


24 F2265 1.55 4 15 75 0.75
32 F2269 2.1 5.5 26 74 0.74 30-32 N/A N/A

100JM/25/4/3/... 1440 12 F2245 2.7 5.8 30 81 0.83


20
26
32
F2249
0132/18
0132/24
4.4
6.3
9 .
9.3
12.8
18.3
52
85
127
83
86
87
0.83
0.83
0.82
C.
100JM/25/8/6/... 695 18 F2265 0.65 2.4 8 . 63 0.62 12-18 ME3.2D N/A
j 22 F2269 0.85 3 11 I 64 0.64 20-22 ME3.2D N/A
28 F2269 1.1 4.7 14 64 0.54 24-28 N/A N/A
30 F2269 1.4 I 5.1 14 65 0.61
32 0132/19 3 33 80 0.71
100JM/25/6/6/... 950 14 F2265 1.35 3.6 15 73 0.74 12-14 N/A N/A
22 F2269 2.1 5.5 26 74 0.74 20-22 N/A N/A
24 F2269 2.5 6.3 26 76 0.75
32 Dl 32/19 4.5 9.6 55 84 0.81
100JM/25/4/6/... 1450 10 F2249 4.4 9.3 52 83 0.83
16 Dl 32/18 6.3 12.8 85 86 0.83
22 0132/24 9 18.3 127 87 0.82
30 Dl 60/20 13 26 140 87 0,82
32 0160/26 17 33 185 88 0.85

100JM/25/8/9/... 695 10 F2265 0.65 2.4 8 . 63 0.62 8-10 ME3.2D N/A


12 . F2265 0.8 2.8 8 65 0.63
16 F2269 0.85 3 11 64 0.64 14-16 ME3.2D N/A
20 F2269 1.1 4.7 14 64 0.54 18-20 N/A N/A
: ‘ 24 F2269 1.4 5.1 14 65 0.61
36 19
/
0132
i 77 33 80 0.71
C
24
JM AEROFOIL
WOODS
AIR MOVEMENT
C Motor Frame Size Schedules
380-420 V / 50 Hz I 3 p Speed Regulation Details
Speed Max. Pitch Motor Full Load Starting Efficiency Power Pitch Speed Controller
Code Motor Rating Current Current Factor Angle
% Range Electronic Auto
rev/mm Angle (0)
(kW) (A) d.o.l. (A) cosø (0)
Transformer
1 OOJM/25/6/9/... 960 8 F2265 1.55 4 15 75 0.75
16 F2269 2.1 5.5 26 74 0.74 16-16 N/A N/A
16 F2269 2.5 6.3 26 76 0.75
26 Dl 32/19 4.5 9.6 55 84 0.81
34 0132/26 6.3 13.9 77 84 0.78
36 Dl 60/23 9.5 21 105 84 0.78

1 OOJM/25/4/9/... 1470 10 Dl 32/18 6.3 12.8 85 86 0.83


16 0132/24 9 18.3 127 87 0.82
22 0160/20 13 26 140 87 0.82
28 0160/26 17 33 185 88 0.85
34 0160/34 22 42.5 255 89 0.84
36 0160/40 26 50 320 89 0.84

1 00JM13114/9/... 1470 10 Dl 32/18 6.3 12.8 85 86 0.83


16 0132/24 9 18.3 127 87 0.82
22 0160/20 13 26 140 87 0.82
28 0160/26 17 33 185 88 0.85
34 Dl 60/34 22 42.5 255 89 0.84
36 Dl 60/40 26 50 320 89 0.84

1 OOJM/40/419/... 1470 12 0132/24 9 18.3 127 87 0.82


20 0160/20 13 26 140 87 0.82
24 0160/26 17 33 185 88 0.85
30 0160/34 22 42.5 255 89 0.84
34 0160/40 26 50 320 89 0.84
38 Dl 80/40 32 62 370 90 0.83
40 D200/40 42 79 474 91 0.84

25
JM AEROFOIL
Motor Frame Size Schedules
380-420 V /50 Hz /3 (p____
— 1
Speed Max. Pitch

Motor Full Load Starting Efficiency Power


Code Motor Rating Current Factor
rev/mm Angle (°) Current %
(kW) (A) d.o.l. (A) cos 0

112JM/40/10/6/... 575 32 0132/19 2.1 5.8 23 74 0.71

112JM/40/8/6/... 720 26 0132/19 3 7.7 33 80 0.71


32 D132/26 4.5 11.2 42 79 0.74

112JM/40/6/6/... 960 18 D132/19 4.5 9.6 55 84 0.81


24 0132/26 6.3 13.9 77 84 0.78
32 0160/23 9.5 21 105 84 0.78

112JM/40/4/6/... 1470 10 0132/24 9 18.3 127 87 0.82


16 0160/20 13 26 140 87 0.82
20 D160/26 17 33 185 88 0.85
i
I 24
28
0160/34
0160/40
22
26
42.5
50
255
320
89
89
0.84
0.84
C)
32 0180/40 32 62 370 90 0.83

112JM/40/10/9/... 575 28 0132/19 2.1 5.8 23 74 0.71


36 0132/26 3.8 11 33 73 0.66

112JM/40/8/9/... 720 22 0132/19 3 7.7 33 80 0.71


32 0132/26 4.5 11.2 42 79 0.74
36 0160/27 7 19 70 80 0.56

112JM/40/6/9/... 960 14 0132/19 4.5 9.6 55 84 0.81


. 20 0132/26 6.3 13.9 77 84 0.78
26 I 0160/23 9.5 21 105 84 0.78
34 0160/30 13 28.5 143 85 0.78
36 0160/40 17.5 37 204 86 0.79

112JM/40/4/9/... 1470 16 0160/26 17 33 185 88 0.85


20 Dl 60/34 22 42.5 255 89 0.84
22 Dl 60/40 26 50 320 89 0.84
I 26 0180/40 32 62 370 90 0.83
32 0200/40 42 79 474 91 0.84
36 0200/46 51 95 570 92 0.84

112JM/50/10/12/... . 575 26 0132/19 2.1 5.8 23 74 0.71


36 D132/26 3.8 11 33 73 0.66

112JM/50/8/12/... . 720 20 0132/19 3 7.7 33 80 0.71


30 0132/26 4.5 11.2 42 79 0.74
36 0160/27 7 19 70 80 0.56

112JM/50/6/12/... 960 12 0132/19 4.5 9.6 55 84 0.81


18 0132/26 6.3 13.9 77 84 0.78
26 0160/23 9.5 21 105 84 0.78
32 0160/30 13 28.5 143 85 0.78
36 0160/40 17.5 37 204 86 0.79

‘ 112JM/50/4/12/... 1470 14 0160/26 17 33 185 88 0.85


18 0160/34 22 42.5 255 89 0.84
I 22 I 0160/40 I 26 50 320 89 0.84
24 0180/40 32 62 370 90 0.83
30 0200/40 42 79 474 91 0.84
34 0200/46 51 95 570 92 0.84
36 W225/M 60 112 840 93 0.83

125JM/40/10/6/... 575 24 Dl 32/19 2.1 5.8 23 74 0.71


32 0132/26 3.8 11 33 73 0.66

26
JM AEROFOIL
woos’
AIR MOVEMENT
C Motor Frame Size Schedules
380-420V/50 Hz/3Ø
Speed Max. Pitch Motor Starting Efficiency Power
Full Load
Code Motor Rating Current Factor
rev/mm Angle (°) Current
(kW) (A) d.o.I. (A) % cos 0

125JM1401816/... 720 18 D132/19 3 7.7 33 80 0.71


28 D132126 4.5 11.2 42 79 0.74
32 Dl 60/27 7 19 70 80 0.56

125JM14016/6/... 960 12 D132/19 4.5 9.6 55 84 0.81


16 D132126 6.3 13.9 77 84 0.78
24 Dl 60/23 9.5 21 105 84 0.78
30 0160/30 13 28.5 143 85 0.78
32 0160/40 17.5 37 204 86 0.79

125JM1401416/... 1470 12 Dl 60/26 17 33 185 88 0.85


16 D160/34 22 42.5 255 89 0.84
20 D160/40 26 50 320 89 0.84
22 D180/40 32 62 370 90 0.83
28 D200/40 42 79 474 91 0.84
32 0200/46 51 95 570 92 0.84

125JM/40/10/9/... 575 18 Dl 32/19 2.1 5.8 23 74 0.71


32 D132/26 3.8 11 33 73 0.66
36 D160/27 5.6 16 64 78 0.65

125JM/40/8/9/... 720 14 0132/19 3 7.7 33 80 0.71


22 D132/26 4.5 11.2 42 79 0.74
30 Dl 60/27 7 19 70 80 0.56
36 Dl 60/34 9.5 24.5 91 91 0.69

125JM/40/6/9/... 960 12 D132/26 6.3 13.9 77 84 0.78


18 D160/23 9.5 21 105 84 0.78
24 0160/30 13 28.5 143 85 0.78
30 0160/40 17.5 37 204 86 0.79
36 Dl 80/40 23 46.5 279 89 0.8

125JM/40/4/9/... 1470 12 0160/34 22 42.5 255 89 0.84


14 D160/40 26 50 320 89 0.84
18 D180/40 32 62 370 90 0.83
22 D200/40 42 79 474 91 0.84
26 D200/46 51 95 570 92 0.84
28 W225/M 60 112 840 93 0.83
30 D200/57 65 120 790 93 0.84
32 W225/MF 73 135 1010 93 0.84
36 W250/M 99 179 1160 94 0.85

125JM/50/4/6/... 1470 12 D160/26 17 33 185 88 0.85


16 D160/34 22 42.5 255 89 0.84
20 D160/40 26 50 320 89 0.84
22 D180/40 32 62 370 90 0.83
28 D200/40 42 79 474 91 0.84
32 D200/46 51 95 570 92 0.84

125JM/50/4/9/... 1470 12 D160/34 22 42.5 255 89 0.84


14 0160/40 26 50 320 89 0.84
18 0180/40 32 62 370 90 0.83
22 0200/40 42 79 474 91 0.84
26 0200/46 51 95 570 92 0.84
30 W225/M 60 112 840 93 0.83
32 D200/57 65 120 790 93 0.84
34 W225/MF 73 135 1010 93 0.84
36 W250/M 99 179 1160 94 0.85

125JM/50/lO/12/... 575 16 D132/19 2.1 5.8 23 74 0.71


28 Dl32/26 3.8 11 33 73 0.66
36 D160/27 5.6 16 64 78 0.65

27
JMAEROFOIL I
I WOOD
MR MOVEMENT

Motor Frame Size Schedules 0


380-420 V /50 Hz /3 p
Speed Max. Pitch Motor Starting Efficiency Power
Full Load
Code Motor Rating Current Factor
rev/mm Angle (°) Current
(kW) (A) d.o.l. (A) % cos 0
125JM/50/8/12/... 720 18 0132/26 4.5 11.2 42 79 0.74
26 Dl 60/27 7 19 70 80 0.56
34 Dl 60/34 9.5 24.5 91 91 0.69
36 D160/40 13 30.5 122 83 0.74

125JM150/6/l21... 960 16 D160/23 9.5 21 105 84 0.78


20 D160/30 13 28.5 143 85 0.78
26 D160/40 17.5 37 204 86 0.79
32 Dl 80/40 23 46.5 279 89 0.8
36 0200/46 31 60.5 363 91 0.81

125JM/50/4/12/... 1470 12 0160/40 26 50 320 89 0.84


16 D180/40 32 62 370 90 0.83
20 0200/40 42 79 474 91 0.84
22 0200/46 51 95 570 92 0.84
26 W225/M 60 112 840 93 0.83
28 0200/57 65 120 790 93 0.84
30 W225/MF i 73 135 1010 93 0.84
36 W250/M 99 179 1160 94 0.85

14OJM/40/12/6/... 480 22 0132/19 I 1.7 6 18 66 0.62


30 Dl 32/26 2.4 8 24 71 0.61
36 Dl 60/27 4.5 16.5 58 71 0.56

14OJM/40/10/6/... 575 16 0132/19 2.1 5.8 23 74 0.71


28 0132/26 3.8 11 33 73 0.66
36 D160/27 5.6 16 64 78 0.65

14OJM/40/8/6/... 720 12 Dl 32/19 3 7.7 33 80 0.71


18 D132/26 4.5 11.2 42 79 0.74
26 Dl 60/27 7 19 70 80 0.56
34 Dl 60/34 9.5 24.5 91 91 0.69
36 0160/40 13 30.5 122 83 0.74

14OJM/40/6/6/... 960 10 0132/26 6.3 13.9 77 84 0.78


16 0160/23 9.5 21 105 84 0.78
20 0160/30 13 28.5 143 85 0.78
26 0160/40 17.5 37 204 86 0.79
34 0180/40 23 46.5 279 89 0.8
36 0200/46 31 60.5 363 91 0.81

14OJM/40/1219/... 480 16 0132/19 1.7 6 18 66 0.62


24 Dl 32/26 2.4 8 24 71 0.61
36 Dl 60/27 4.5 16.5 58 71 0.56

14OJM/40/10/9/... 575 22 0132/26 3.8 11 33 73 0.66


30 Dl 60/27 5.6 16 64 78 I 0.65
36 Dl 60/34 7.5 20.7 83 79 0.66

14OJM/40/8/9/... 720 14
: 0132/26 4.5 11.2 42 79 0.74
20 0160/27 7 19 70 80 0.56
26 0160/34 9.5 24.5 91 91 0.69
34 0160/40 13 30.5 122 83 0.74
36 0180/40 17 40 200 85 0.72

140JM140/6/91... 960 14 0160/30 13 28.5 143 85 0.78


20 0160/40 17.5 37 204 86 0.79
26 0180/40 23 46.5 279 89 0.8
32 0200/46 31 60.5 363 91 0.81
36 0200/57 39 71.5 429 91 0.87

C
28
JM AEROFOIL
C Motor Frame Size Schedules
380-420 V /50 Hz /3 0
Speed Max. Pitch Motor Starting Efficiency Power
Full Load
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) d.o.l. (A) % cos 0
(A)
1 4OJM/50/4/9/... 1470 10 Dl 80/40 32 62 370 90 0.83
16 D200/40 42 79 474 91 0.84
18 D200/46 51 95 570 92 0.84
20 W225/M 60 112 840 93 0.83
22 D200/57 65 120 790 93 0.84
24 W225/MF 73 135 1010 93 0.84
30 W250/M 99 179 1160 94 0.85

1 4OJM/50/1 0/12/... 575 20 0132/26 3.8 11 33 73 0.66


26 0160/27 5.6 16 64 78 0.65
34 Dl 60/34 7.5 20.7 83 79 0.66
36 Dl 80/29 9.5 23.5 106 82 0.71

1 4OJM/50/8/1 2/... 720 18 Dl 60/27 7 19 70 80 0.56


24 Dl 60/34 9.5 24.5 91 91 0.69
30 0160/40 13 30.5 122 83 0.74
36 Dl 80/40 17 40 200 85 0.72

1 4OJM/50/6/1 2/... 960 12 Dl 60/30 13 28.5 143 85 0.78


18 0160/40 17.5 37 204 86 0.79
24 Dl 80/40 23 46.5 279 89 0.8
30 0200/46 31 60.5 363 91 0.81
36 D200/57 39 71.5 429 91 0.87

1 40JM1501411 2/... 1470 12 D200/40 42 79 474 91 0.84


14 D200/46 51 95 570 92 0.84
18 W225/M 60 112 840 93 0.83
18 D200/57 65 120 790 93 0.84
20 W225/MF 73 135 1010 93 0.84
28 W250/M 99 179 1160 94 0.85

1 6OJM/40/1 2/6/... 480 14 Dl 32/19 1.7 6 18 66 0.62


18 Dl 32/26 2.4 8 24 71 0.61
30 Dl 60/27 4.5 16.5 58 71 0.56
32 0160/34 6.3 20.2 65 74 0.61

1 6OJM/40/1 0/6/... 575 18 0132/26 3.8 11 33 73 0.66


24 Dl 60/27 5.6 16 64 78 0.65
30 Dl 60/34 7.5 20.7 83 79 0.66
32 Dl 80/29 9.5 23.5 106 82 0.71

1 6OJM/40/8/6/... 720 10 Dl 32/26 4.5 11.2 42 79 0.74


16 Dl 60/27 7 19 70 80 0.56
20 Dl 60/34 9.5 24.5 91 91 0.69
26 Dl 60/40 13 30.5 122 83 0.74
32 Dl 80/40 17 40 200 85 0.72

1 6OJM/40/6/6/... 960 12 Dl 60/30 13 28.5 143 85 0.78


16 Dl 60/40 17.5 37 204 86 0.79
20 Dl 80/40 23 46.5 279 89 0.8
26 D200/46 31 60.5 363 91 0.81
30 0200/57 39 71.5 429 91 0.87
32 W200/LFR 41 83 498 90 0.79

1 6OJM/40/1 2/9/... 480 12 Dl 32/26 2.4 8 24 71 0.61


24 Dl 60/27 4.5 16.5 58 71 0.56
32 Dl 60/34 6.3 20.2 65 74 0.61
36 Dl 80/29 8 24 84 79 0.61

1 60JM/40/1 0/9/... 575 12 Dl 32/26 3.8 11 33 73 0.66


18 0160/27 5.6 16 64 78 0.65
24 Dl 60/34 7.5 20.7 83 79 0.66
28 Dl 80/29 9.5 23.5 106 82 0.71
32 Dl 80/35 12 29.3 125 82 0.72
36 D200/38 15 35.7 160 85 0.72

29
JM AEROFOIL
WOODS
AIR MOVEMENT

Motor Frame Size Schedules C


380-420 V /50 Hz /3
Speed Max. Pitch Motor Starting Efficiency Power
Full Load
Code Motor Rating Current Factor
rev/mm Angle (°) Current
I (kW) (A) d.o.I. (A) 0

:
16OJM/40/8/9/... 720 16 0160/34 9.5 24.5 91 91 0.69
20 D160/40 13 30.5 122 83 0.74
26 Dl 80/40 17 40 200 85 0.72
28 D200/38 20 45.5 209 88 0.72
32 D200/46 24 54 248 89 0.72
36 D200/57 33 73.5 338 89 0.73

16OJM/40/6/9/... 960 10 D160/40 17.5 37 204 86 0.79


16 0180/40 23 46.5 279 89 0.8
20 0200/46 31 60.5 363 91 0.81
24 0200/57 39 71.5 429 91 0.87
26 W225/M 43 87 522 92 0.78
30
34
W225/MF
W250/M
53
62
108
120
648
720
92
93
0.77
0.8
C
16OJM/50/6/9/... 960 12 D160/40 17.5 37 204 86 0.79
16 0180/40 23 46.5 279 89 0.8
20 D200/46 31 60.5 363 91 0.81
24 D200/57 39 71.5 429 91 0.87
26 W200/LFR 41 83 498 90 0.79
30 W225/MF 53 108 648 92 0.77
32 W250/M 62 120 720 93 0.8

160JM/50/12/12/... 480 10 Dl 32/26 2.4 8 24 71 0.61


20 0160/27 4.5 16.5 58 71 0.56
28 Dl 60/34 6.3 20.2 65 74 0.61
32 D180/29 8 24 84 79 0.61
36 D180/35 10.5 32 105 78 0.61

16OJM/50/10/12/... 575 10 D132/26 3.8 11 33 73 0.66


16 0160/27 5.6 16 64 78 0.65
20 Dl 60/34 7.5 20.7 83 79 0.66
24 Dl 80/29 9.5 23.5 106 82 0.71
28 0180/35 12 29.3 125 82 0.72
34 D200/38 15 35.7 160 85 0.72
36 D200/46 18 44 220 85 0.69

16OJM/50/8/12/... 720 12 0160/34 9.5 24.5 91 91 0.69


(.
18 D160/40 13 30.5 122 83 0.74
22 D180/40 17 40 200 85 0.72
24 D200/38 20 45.5 209 88 0.72
28 0200/46 24 54 248 89 0.72
36 0200/57 33 73.5 338 89 0.73

16OJM/50/6/12/... 960 12 Dl 80/40 23 46.5 279 89 0.8


18 0200/46 31 60.5 363 91 0.81
22 0200/57 39 71.5 429 91 0.87
22 W200/LFR 41 83 498 90 0.79
22 W225/M 43 87 522 92 0.78
26 W225/MF 53 108 648 92 0.77
28 W250/M 62 120 720 93 0.8

C
30
JM AEROFOIL
(—) Motor Frame Size Schedules:
wo
AIR MOVEMENT

Two Speed (Full and Half Pole Change)


400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating I Current Current Factor
rev/mm Angle (°) (kW) rev/mm L (kW) d.o.l. (A) % cosø
(A)
31JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

31JM/16/4-8/5/... 1420 40 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59

31JM/16/2-4/5/... 2840 16 BT5 0.25 1440 0.03 0.86/0.22 2.8/1.1 51/43 0.81/0.46
26 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.41
40 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5

35JM11616-1215/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

• 35JM/16/4-8/5/... 1420 40 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
( 35JM/16/2-4/5/... 2840 8
16
BT5 0.25 1440 0.03 0.86/0.22 2.8/1.1 51/43 0.81/0.46
BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.41
28 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5
40 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

4OJM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

4OJM/16/4-8/5/... 1420 26 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
38 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
40 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

4OJM/1612-4/51... 2840 8 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 I 68/55 0.76/0.41
16 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5
26 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

45JM/16/6-12/5/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM11614-8/5/... 1420 16 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
24 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
38 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
40 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

45JM/16/2-4/5/... 2840 10 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5
16 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45

45JM/20/6-12/3/... 900 36 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM/20/4-8/3/... 1420 22 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
34 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
36 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

45JM/20/2-4/3/... 2910 8 BT9 0.44 1440 0.055 1.2/0.35 4.5/1.2 68/55 0.76/0.41
16 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5
24 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45
36 F2225B 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41

45JM/20/6-12/6/... 900 40 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

45JM/20/4-8/6/... 1420 14 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
24 BT9 0.28 i 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
38 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
40 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

45JM/20/2-4/6/... 2910 8 CT5 0.8 1440 0.1 2.3/0.75 9/3 67/37 0.77/0.5
16 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45
26 F2225B 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41
40 F2229B 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

C 5OJM/16/6-12/5/... 915 36
40
CT5
CT9
0.21
0.41
470
470
0.026
0.05
0.85/0.3
1.6/0.7
1.7/0.45
2.8/0.9
44/19
53/20
0.81/0.67
0.7/0.54

31
JM AEROFOIL
WOODS’
AIR MOVEMENT
Motor Frame Size Schedules: C)
Two Speed (Full and Half Pole Change)
400 V /50 Hz /3 0
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Rating Current Current Factor
Motor
rev/mm Angle (0)
(kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
50JM/16/4-8/5/... 1 1420 8 BT5 0.165 700 0.025 i 0.63/0.3 2/0.6 51/22 0.75/0.59
16 8T9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
26 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
40 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

5OJM/20/6-1213/... 915 36 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67

5OJM/20/4-8/3/... 1420 14 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
24 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
36 C15 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56

9/3 67/37 0.77/0.5


5OJM/20/2-4/3/... 2910 10
16
28
CT5
CT9
F2225B
0.8
1.4
2.7
1440
1440
1440
0.1
0.17
0.34
2.3/0.75
3.1/1.1
5.5/2.5
16.5/5
32/9
78/50
79/49
0.84/0.45
0.90/0.41
C
36 F2229B 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

5OJM/20/6-12/6/... 915 34 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
40 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

5OJM/20/4-8/6/... 1420 14 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
26 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
40 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

5OJM/20/2-4/6/... 2910 8 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45
18 F2225B 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41
30 F2229B 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

56JM/16/6-12/5/... 900 24 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
40 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

56JM/16/4-8/5/... 1420 8 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
18 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
28 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

56JM/20/6-12/3/... 900 34 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
36 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54

56JM/20/4-8/3/... 1420 8 BT5 0.165 700 0.025 0.63/0.3 2/0.6 51/22 0.75/0.59
Cs
16 BT9 0.28 720 0.035 0.9/0.6 3/0.9 58/18 0.77/0.48
26 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
36 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47

56JM/20/2-4/3/... 2910 10 CT9 1.4 1440 0.17 3.1/1.1 16.5/5 78/50 0.84/0.45
18 F2225B 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41
30 F2229B 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41

56JM/20/6-12/6/... 900 24 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
38 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
40 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

56JM/20/4-8/6/... 1420 16 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
26 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47
40 F2265B 1.8 720 0.23 4.2/1.8 35936 77/47 0.80/0.40

56JM/20/2-4/6/... 2910 10 F2225B 2.7 1440 0.34 5.5/2.5 32/9 79/49 0.90/0.41
20 F2229B 5 1440 0.65 . 9.5/4.8 80/23 83/54 0.84/0.41

63JM/20/6-1213/... 900 20 CT5 0.21 470 0.026 0.85/0.3 . 1.7/0.45 44/19 0.81/0.67
32 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
36 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

32
JM AEROFOIL
C Motor Frame Size Schedules
wooii)
AIR MOVEMENT

Two Speed (Full and Half Pole Change)


400V/5OHz/3Ø

Speed Max. Pitch Motor Low Speed Starting Efficiency Power


Full Load
Code Motor Rating Current Current Factor
rev/mm Angle (0)

(kW) rev/mm (kW) d.o.l. (A) 0/


cosø
(A)
63JM/2014-813/... 1420 12 CT5 0.5 700 0.06 1.28/0.5 3.7/1 71/31 0.79/0.56
22 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47
36 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
63JM/20/6-12/6/... 900 10 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
22 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
36 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
63JM/20/4-8161... 1420 14 CT9 0.9 700 0.12 i 2.5/1.0 9/2.5 62/40 0.80/0.47
!
. I 26 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
36 F22698 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
63JM12512-4/3/... 2910 12 F2225B 2.7 1440 0.34 5.5)2.5 32/9 79/49 0.90/0.41
18 F22298 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41
18 D132/14 4.8 1480 0.6 9.5/2.4 56/1 6.5 80/68 0.91/0.56
: 24 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92)0.56
32 0160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.47
I 63JM/25/4-8/6/... 1440 30 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
I 36 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
63JM/25/2-4/6/... 2910 12 F2229B 5 1440 0.65 9.5/4.8 80/23 83/54 0.84/0.41
12 Dl 32/14 4.8 1480 0.6 9.5/2.4 56/1 6.5 80/68 0.91/0.56
16 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92/0.56
26 0160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.47
32 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.48
36 0160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49
63JM/25/6-12/9/... 935 40 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
63JM/25/4-8/9/... 1440 26 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
38 F2269B 3.1 700 0.39 7/2.6 40/10 81)58 0.79/0.38
40 0132)19 4.5 I 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50

(- 63JM/25/2-4/9/... 2910 8
8
F2229B
D132/14
5
4.8
1440
1480
0.65
0.6
9.5/4.8
9.5/2.4 I
80/23
56/1 6.5
83/54
80/68
0.84/0.41
0.91/0.56
14 D132/19 7.15 1470 0.9 13.5/3.3 88/26 83/72 0.92/0.56
22 0160/23 12 1480 1.49 21.8/5.9 175/50 89/78 0.89/0.47
26 D160/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.48
32 D160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49
71JM/20/6-1213/... 900 10 CT5 0.21 470 0.026 0.85/0.3 1.7/0.45 44/19 0.81/0.67
22 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
: 36 F22658 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
71JM/20/4-8/3/... 1440 12 CT9 0.9 700 0.12 2.5/1.0 9/2.5 62/40 0.80/0.47
26 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
36 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
71JM/20/6-12)6/... 900 12 C19 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
28 F2265B 0.95 470 0.12 2.9)1.05 10)2.2 68/36 0.70/0.45
36 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
71JM/20/4-8/6/... 1440 16 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
26 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
71JM/25/4-8/3/... 1440 30 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
32 F22698 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

( 71JM/25/6-12/6/... 935 I 34 F22658 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70)0.45
‘.__- 36 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

33
JM AEROFOIL
Motor Frame Size Schedules:
woois. I
MR MOVEMENT
C
Two Speed (Full and Half Pole Change)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) % COS

71 JM/25/4-8/6/... 1440 20 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
30 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
36 Dl 32/19 4.5 730 0.56 10.5/2.4 58/1 2.5 79/67 0.78/0.50

71 JM/2516-l 2/9/... 935 26 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
36 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

71 JM/25/4-8/9/... 1440 12 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
24 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
32 Dl 32/19 4.5 730 0.56 10.5/2.4 58/1 2.5 79/67 0.78/0.50
36 Dl 32/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50

71 JM/31 /2-4/9/... 2910 12


16
Dl 60/23
Dl 60/28
12
15.5
1480
1480
1.49
1.94
21 .8/5.9
28/7.7
175/50
224/65
89/78
90/79
0.89/0.47
0.90/0.48
C
20 Dl 60/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49
22 Dl 80/3 1 23.9 1480 2.98 42.5/8.8 255/71 90/82 0.91/0.61

8OJM/20/6-1 2/3/... 935 14 CT9 0.41 470 0.05 1.6/0.7 2.8/0.9 53/20 0.7/0.54
28 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
36 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

80JM/20/4-8/3/... 1440 18 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
26 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

80JM/20/6-1 2/6/... 935 18 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
30 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42

80JM/20/4-8/6/... 1440 8 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
16 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

8OJM/25/6-1 2/3/... 935 32 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45

8OJM/25/4-8/3/... 1440 20 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
32 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38

8OJM/25/6-1 2/6/... 935 22


34
F2265B
F2269B
0.95
1.6
470
460
0.12
0.2
2.9/1.05
4.8/1.95
10/2.2
23/4.5
68/36
70/37
0.70/0.45
0.69/0.42
C
36 Dl 32/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40

8OJM/25/4-8/6/... 1440 12 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
20 &2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
28 Dl 32/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50
34 Dl 32/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
36 Dl 60/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

80JM/25/6-1 2/9/... 935 16 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
28 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
36 Dl 32/19 3.3 480 0.41 10.2/2.7 5 2/9.5 73/55 0.64/0.40

80JM/25/4-8/9/... 1440 14 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
22 Dl 32/19 4.5 730 0.56 10.5/2.4 58/1 2.5 79/67 0.78/0.50
28 Dl 32/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
36 Dl 60/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46

8OJM/31 /2-4/9/... 2910 8 Dl 60/28 15.5 1480 1.94 28/7.7 224/65 90/79 0.90/0.48
12 0160/32 19.4 1480 2.42 34.2/9.1 273/78 90/78 0.91/0.49
14 Dl 80/31 23.9 1480 2.98 42.5/8.8 255/71 90/82 0.91/0.61

90JM/25/6-1 2/3/... 935 22


32
F2265B
F2269B
0.95
1.6
470
460
0.12
0.2
2.9/1.05
4.8/1.95
10/2.2
23/4.5
68/36
70/37
0.70/0.45
0.69/0.42
(

34
JM AEROFOIL
WOODS
AIR MOVEMENT
Motor Frame Size Schedules:
Two Speed (Full and Half Pole Change)

400 V/50 Hz/3p

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
_____________ rev/mm Angle (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
90JM12514-813/... 1440 12 F2265B 1.8 720 0.23 4.2/1.8 21/5 77/47 0.80/0.40
22 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
28 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50
32 0132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
9OJM/25/6-12/6/... 935 i 14 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
24 F2269B 1.6 460 0.2 4.8/1.95 ! 23/4.5 70/37 0.69/0.42
32 0132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
9OJM/25/4-8/6/... 1440 12 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
18 Dl 32/19 4.5 730 0.56 10.5/2.4 58/1 2.5 79/67 0.78/0.50
C’ 24
32
D132/26
0160/23
6.3
9.7
730
740
0.82
1.19
14.5/3.5
18.5/5.5
87/19
145/33
81/69
87/74
0.76/0.50
0.86/0.46
9OJM/25/6-1219/... 935 16 F2269B 1.6 460 . 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
28 Dl 32/19 3.3 480 i 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
36 D132/26 4.7 480 0.56 11.5/2.8 I 61/10 77/62 0.77/0.47
90JM125l4-8/9/... 1440 10 D132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50
16 Dl 32/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
24 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
32 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
100JM/25/6-12/3/... 935 16 F2265B 0.95 470 0.12 2.9/1.05 10/2.2 68/36 0.70/0.45
26 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
32 D132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
100JM/25/4-8/3/... 1440 14 F2269B 3.1 700 0.39 7/2.6 40/10 81/58 0.79/0.38
20 0132/19 4.5 730 0.56 10.5/2.4 58/12.5 79/67 0.78/0.50
26 0132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
32 0160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
100JM/25/6-12/6/... 950 16 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
26 Dl 32/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
32 0132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
0 100JM/25/4-8/6/... 1450 10
16
Dl 32/19
0132/26
4.5
6.3
730
730
0.56
0.82
10.5/2.4
14.5/3.5
58/1 2.5
87/19
79/67
81/69
0.78/0.50
0.76/0.50
24 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
30 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
100JM/25/6-12/9/... 960 10 F2269B 1.6 460 0.2 4.8/1.95 23/4.5 70/37 0.69/0.42
18 0132/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
26 0132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
36 0160/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.44
100JM/25/4-8/9/... 1470 10 D132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
16 0160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
22 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
100JM/31/4-8/9/... 1470 10 0132/26 6.3 730 0.82 14.5/3.5 87/19 81/69 0.76/0.50
16 D160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
22 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
26 D180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.60
30 0180/35 20.1 735 2.54 38/10.9 266/60 90/78 0.86/0.43
1000JM/40/4-8/9/... 1470 12 0160/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
20 Dl 60/30 13.4 730 1.68 26.8/8.8 208/47 87/72 . 0.82/0.38
22 0180/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.60
26 0180/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
30 D200/36 23.9 735 2.98 46/1 3.5 330/61 i 90/80 0.83/0.40
38 0200/46 32.8 735 4.1 62/1 8.5 450/96 91/81 0.84/0.40
40 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.54

35
JM AEROFOIL
wooDi
Motor Frame Size Schedules: AIR MOVEMENT
C
Two Speed (Full and Half Pole Change)
400 V/50 Hz/3m

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
11 2JM/40/6-1 2/6/... 960 12 Dl 32/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
20 0132/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
26 Dl 60/27 7.46 490 0.93 17.3/4.8 91/1 7.5 82/64 0.76/0.44
32 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45

11 2JM/40/4-8/6/... 1470 10 Dl 60/23 9.7 740 1.19 18.5/5.5 145/33 87/74 0.86/0.46
16 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0. 82/0 .38
18 Dl 80/29 15.7 730 1.94 29.9/5.7 21 0/35 89/82 0.85/0.60
22 Dl 80/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
26 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.40
32 0200/46 32.8 735 4.1 62/1 8.5 450/96 91/8 1 0.84/0.40

11 2JM/40/6-1 2/9/... 960 8 Dl 32/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40 C
14 Dl 32/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
22 Dl 60/27 7.46 490 0.93 17.3/4.8 91 /1 7.5 82/64 0.76/0.44
30 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
36 Dl 80/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

11 2JM14014-8/9/... 1470 10 Dl 60/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
14 Dl 80/29 15.7 730 1.94 29.9/5.7 21 0/35 89/82 0.85/0.60
18 Dl 80/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
20 D200/36 23.9 735 2.98 46/1 3.5 330/61 90/80 0.83/0.40
26 D200/46 32.8 735 4.1 62/1 8.5 450/96 91/8 1 0.84/0.40
28 W200/LFR 37 730 7 69/22 448/110 91 .5/85 0.85/0.54
34 W225/M 45 730 9 83/25 581 /1 25 92/86 0.85/0.61
36 W225/MF 55 730 11 101/29 707/1 45 92 .5/88 0.85/0.62

11 2JM/50/6-1 2/12/.. 960 12 Dl 32/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0. 77/0 .47
20 Dl 60/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.44
28 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0. 77/0 .45
36 Dl 80/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

11 2JM/50/4-8/1 2/... 1470 8 Dl 60/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
12 Dl 80/29 15.7 730 1.94 29.9/5.7 21 0/35 89/82 0.85/0.60
16 Dl 80/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
20 D200/36 23.9 735 2.98 46/1 3.5 330/61 90/80 0.83/0.40
24 D200/46 32.8 735 4.1 62/18.5 450/96 91/8 1 0.84/0.40
26 W200/LFR 37 730 7 69/22 448/110 91 .5/85 0.85/0.54
32 W225/M 45 730 9 83/25 581 /1 25 92/86 0.85/0.61
36 W225/MF 55 730 11 101/29 707/145 92 .5/88 0.85/0.62

1 25JM/40/6-1 2/6/... 960 8 Dl 32/19 3.3 480 0.41 10.2/2.7 52/9.5 73/55 0.64/0.40
12 Dl 32/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
18 Dl 60/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.44
26 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
32 Dl 80/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46

1 25JM/40/4-8/6/... 1470 10 Dl 60/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
12 Dl 80/29 15.7 730 1.94 29.9/5.7 210/35 89/82 0.85/0.60
16 Dl 80/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
18 0200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.40
22 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.40
24 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.54
28 W225/M 45 730 9 83/25 581 /1 25 92/86 0.85/0.61
32 W225/MF 55 730 11 101/29 707/1 45 92.5/88 0.85/0.62

1 25JM/40/6-1 2/9/... 960 8 Dl 32/26 4.7 480 0.56 11.5/2.8 61/10 77/62 0.77/0.47
14 Dl 60/27 7.46 490 0.93 17.3/4.8 91/17.5 82/64 0.76/0.44
20 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
28 0180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
32 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
34
36
D200/46
W200/LFR
23.1
24
490
475
2.91
5
51/15
46/17
308/63
345/85
86/71
89/81
0.76/0.40
0.88/0.53
C

36
JM AEROFOIL
Motor Frame Size Schedules:
oois’) AIR MOVEMENT

Two Speed (Full and Half Pole Change)


400 V/50 Hz/3Ø

Speed Max. Pitch Motor Low Speed II Load Starting Efficiency Power
Code Motor Rating Current Current 1 Factor

125JM/40/4-8/9/...
rev/mm
1470
Angle (°)
10 D180/35
(1(W)
20.1
rev/mm
735
(kW)
2.54
(A)
38/10.9
J d..I. (A)
266/60
%
90/78
cos 0
0.86/0.43
12 D200136 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.40
18 D200/46 32.8 735 4.1 62/1 8.5 450/96 9 1/81 0.84/0.40
20 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.54
22 W225/M 45 730 9 83/2 5 581 /1 25 92/86 0.85/0.61
26 W225/MF 55 730 11 101 /29 707/1 45 92.5/88 0.85/0.62
32 W250/M 75 735 15 137/4 1 1027/205 93.2/89 0.85/0.6
36 W250/MF 90 735 18 162/48 121 5/240 93 .5/89.5 0.86/0.61

125JM/50/4-8/6/... 1470 10 0160/30 13.4 730 1.68 26.8/8.8 208/47 87/72 0.82/0.38
12 0180/29 15.7 730 1.94 29.9/5.7 21 0/35 89/82 0.85/0.60
14 0180/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
18 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.40
22 D200/46 32.8 735 4.1 62/18.5 450/96 91/81 0.84/0.40
24 W200/LFR 37 730 . 7 69/22 448/110 91.5/85 0.85/0.54
28 W225/M 45 730 9 83/25 581/125 92186 0.85/0.61
32 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62

125JM/50/4-8/9/... 1470 10 D180/35 20.1 735 2.54 38/1 0.9 266/60 90/78 0.86/0.43
14 D200/36 23.9 735 2.98 46/13.5 330/61 90/80 0.83/0.40
; 18 ‘0200/46 ‘ 32.8 735 I 4.1 62/18.5 450/96 91/81 0.84/0.40
• 20 W200/LFR 37 730 7 69/22 448/110 91.5/85 0.85/0.54
24 W225/M 45 730 9 83/25 581/125 1, 92/86 0.85/0.61
28 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62
34 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.6
36 W250/MF 90 735 18 162/48 1215/240 93.5/89.5 0.86/0.61

125JM/50/6-12/12/... 960 10 Dl 60/27 7.46 490 0.93 17.3/4.8 91 /1 7.5 82/64 0.76/0.44
18 0160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
24 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
28 0200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
32 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
34 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
36 W225/M 30 485 6 57/20 400/1 00 89.5/82 0.85/0.52

(. 125JM/50/4-8/12/... 1470 10
16
16
0200/36
0200/46
W200/LFR
23.9
32.8
37
735
735
730
2.98
4.1
7
46/1 3.5
62/18.5
69/22
330/61
450/96
90/80
91/81
448/110 91.5/85
0.83/0.40
0.84/0.40
0.85/0.54
20 W225/M 45 730 9 83/25 581/1 25 92/86 0.85/0.61
24 W225/MF 55 730 11 101 /29 707/1 45 92.5/88 0.85/0.62
30 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.6
34 W250/MF 90 735 18 162/48 I 1215/240 93.5/89.5 0.86/0.61

14OJM/40/6-12/6/... 960 , 12 Dl 60/27 7.46 490 0.93 17.3/4.8 91/1 7.5 82/64 0.76/0.44
‘ 18 D160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
24 ;D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
28 0200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
32 0200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
34 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
36 W225/M 30 485 6 57/20 400/100 89.5/82 0.85/0.52

14OJM/50/6-12/9/... 960 8 Dl 60/27 7.46 490 0.93 17.3/4.8 91 /1 7.5 82/64 0.76/0.44
14 0160/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
20 D180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
24 0200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
26 D200/46 23.1 490 2.91 5 1/15 308/63 86/71 0.76/0.40
28 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
32 W225/M 30 485 6 57/20 400/1 00 89.5/82 0. 85/0.52
36 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.5

37
JM AEROFOIL
Motor Frame Size Schedules: AIR MOVEMENT
wooii
C
Two Speed (Full and Half Pole Change)
400 V/50 Hz/3Ø

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) °‘
cosø
1 4OJM/50/4-8/9/... 1470 10 D200/46 32.8 735 4.1 62/1 8.5 450/96 91/81 0.84/0.40
12 W200/LFR 37 730 7 69/22 448/110 91 .5/85 0.85/0.54
16 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.61
20 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62
24 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.6
28 W250/MF 90 735 18 162/48 121 5/240 93.5/89.5 0.86/0.61

14OJM/50/6-1 2/12/... 960 10 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
16 Dl 80/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
20 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
22 D200/46 23.1 490 2.91 51/15 308/63 86/71 1 0.76/0.40
24 W200/LFR 24 475 5 46/17 345/85 89/8 1 0.88/0.53.
28
32
W225/M
W225/MF
30
37
485
485
6
7.4
57/20
70/25
400/1 00
490/125
89.5/82
89.5/82
0.85/0.52
0.85/0.52
C
36 W250/M 45 485 9 83/27 623/135 91.5/85.5 0.86/0.56

1 4OJM/50/4-8/1 2/... 1470 8 D200/46 32.8 735 4.1 62/18.5 450/96 91/8 1 0.84/0.40
10 W200/LFR 37 730 7 69/22 448/110 91 .5/85 0.85/0.54
12 W225/M 45 730 9 83/25 581/125 92/86 0.85/0.61
16 W225/MF 55 730 11 101/29 707/145 92.5/88 0.85/0.62
20 W250/M 75 735 15 137/41 1027/205 93.2/89 0.85/0.6
24 W250/MF 90 735 18 162/48 121 5/240 93.5/89,5 0.86/0.61

1 6OJM/40/6-1 2/6/... 960 10 Dl 60/34 11.2 480 1.42 25.5/7 135/26 83/65 0.77/0.45
14 0180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
18 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
20 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
22 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
24 W225/M 30 485 6 57/20 400/1 00 89.5/82 0.85/0.52
28 W225/MF 37 485 7.4 70/25 490/125 89.5/82 0.85/0.52
32 W250/M 45 485 9 83/27 623/1 35 91 .5/85.5 0.86/0.56

1 60JM14016-1 2/9/... 960 10 0180/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
12 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
14 0200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
16 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
18
22
W225/M
W225/MF
30
37
485
485
6
7.4
57/20
70/25
400/1 00
490/1 25
89. 5/82
89.5/82
0.85/0.52
0.85/0.52
(.
26 W250/M 45 485 9 83/27 623/1 35 91.5/85.5 0.86/0.56
30 W250/MF 55 490 11 100/33 750/165 92.1/86.2 0.86/0.56

1 6OJM/50/6-1 2/9/... 960 10 Dl 80/35 16.4 490 2.05 35/9.1 228.38 85/71 0.79/0.46
12 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
14 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
16 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
20 W225/M 30 485 6 57/20 400/1 00 89.5/82 0.85/0.52
22 W225/MF 37 485 7.4 70/25 490/1 25 89.5/82 0.85/0.52
26 W250/M 45 485 9 83/27 623/1 35 91.5/85.5 0.86/0.56
30 W250/MF 55 490 11 100/33 750/1 65 92.1/86.2 0.86/0.56

1 6OJM/50/6-1 2/12/... 960 10 D200/38 20.5 490 2.54 45/13 272/55 86/71 0.76/0.40
10 D200/46 23.1 490 2.91 51/15 308/63 86/71 0.76/0.40
12 W200/LFR 24 475 5 46/17 345/85 89/81 0.88/0.53
16 W225/M 30 485 6 57/20 400/1 00 89.5/82 0.85/0.52
20 W225/MF 37 485 7.4 70/25 490/1 25 89.5/82 0.85/0.52
22 W250/M 45 485 9 83/27 623/1 35 91.5/85.5 0.86/0.56
26 W250/MF 55 490 11 100/33 750/165 92.1/86.2 0.86/0.56

38
JM AEROFOIL
C Motor Frame Size Schedules
wooái I
AIR MOVEMENT

Two Speed (Full and Half Dual Wound)


400 V/50 Hz/34

Code
Speed Max. Pitch
1 Motor
Motor
Rating
Low Speed Full Load
Current
Starting
Current
Efficiency Power
Factor
rev/mm Angle (1 (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0

45JM/20/6-12/3/... 900 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

45JM/2014-8/31... 1420 36 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

45JM/20/2-4/3/... 2910 32 F2245B . 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
• 36 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

45JM/20/6-12/6/... 900 40 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 ‘0.64/0.53

45JM/20/4-8/6/... 1420 40 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

45JM/20/2-4/6/... 2910 22 F2245B 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
34 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

5OJM/20/6-12/3/... 915 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

50JM12014-8/31... 1420 36 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

5OJM/20/2-4/3/... 2910 24 F2245B 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
34 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76
:
5OJM/20/6-12/6/... 915 40 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

50JM/20/48/6/,., 1420 40 F2265B 1.6 . 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

5OJM/20/2-416/... 2910 14 F22458 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
24 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

56JM/20/6-12/3/... 900 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

56JM/20/4-8/3/... 1420 36 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

56JM/20/2-4/3/... 2910 16 F2245B 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
24 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76
(.•) 56JM/20/6-12/6/... 900 40 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

56JM/20/4-8/6/... I 1420 40 F2265B : 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65

56JM/20/2-4161... 2910 8 F2245B 2.15 1440 0.27 4.9/0.9 29/3.2 74/60 0.85/0.77
14 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76

63JM/20/6-12/3/... 900 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
63JM/20/4-8/3/... 1420 34 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
36 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
63JM/20/6-12/6/... 900 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
63JM/20/4-8/6/... 1420 24 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
36 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
63JM/2512-4/31... 2910 10 F2245R 2.15 1440 0.27 4.9/0.9 29/3,2 74/60 0.85/0.77
16 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 74/61 0.85/0.76
16 Dl 32/14 4.1 1400 0.51 7.7/2.1 48/12 82/59 :0.80/0.56
22 D132/19 6 1460 0.75 11.6/2.2 81/15 . 82/69 0.91/0.72
30 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.69
32 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.70

63JM/25/4-8/6/... 1440 28 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
36 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

39
JM AEROFOIL
Motor Frame Size Schedules:
wooós
AIR MOVEMENT I C)
Two Speed (Full and Half Dual Wound)
400 V/50 Hz/3p

Code
Speed Max. Pitch
Motor
Motor
Rating
Low Speed Full Load
Current
Starting
Current
Efficiency Power
Factor 1
rev/mm Angle () (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
63JM/25/2-4/6/... 2910 8 F2249B 3.7 1440 0.46 8.5/1.4 50/6.7 ‘ 74/61 0.85/0.76
10
14
D132/14
i D132119
4.1
6
: 1400
1460
0.51
0.75
7.7/2.1
11.6/2.2
48/12
81/15
82/59
82/69
0.80/0.56
0.91/0.72
20 0160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.69
26 I D160/28 12 1480 1.49 21.8/4.2 i 196/33 89/73 0.88/0.70
30 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.70

63JM/25/6-12/9/... 935 36 F2265B I 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53.
40 F2269B 1.3 , 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

63JM/25/4-8/9/... 1440 24 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
: ‘

.
34
40
F2269B
Dl 32/19
2.7
4.1
700
725
I 0.33
0.51 ,
6.7/1.6
9.5/2.2
37/4 1
55/9
77/48
79/54
0.77/0.65.
0.79/0.64
C
: 63JM/25/24/9/... 2910 10 0132/19 6 1460 0.75 11.6/2.2 81/15 82/69 0.91/0.72
16 0160/23 . 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.69
20 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.70
24 D160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0,88/0.70

71JM/2016-12/31... 900 36 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53

71JM/20/4-8/3/... 1440 24 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
34 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/20/6-12/6/... 900 24 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
36 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

71JM/2014-8161... 1440 14 F22658 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
24 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/25/4-8/3/... 1440 28 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
32 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

71JM/25/6-12/6/... 935 28 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
36 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63 (
71JM/25/4-8/6/... 1440 18 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
28 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
36 Dl 32/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64

71JM/2516-12/91... 935 22 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
34 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
36 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

71JM/25/4-8/9/... 1440 10 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
20 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
30 0132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
36 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 , 81/51 . 0.87/0.62’
71JM/31/2-4/9/... ‘ 2910 8 D160/23 9.3 1470 1.19 17.6/3.4 155/27 88/72 0.87/0.69
. 10 D160/28 12 1480 1.49 21.8/4.2 196/33 89/73 0.88/0.70
14 0160/32 14.9 1480 1.86 27.5/5.2 248/42 I 89/73 0.88/0.70
16 D180/31 ‘ 17.9 1480 2.24 33/6.6 249/53 89/77 , 0.87/0.63

8OJM/20/6-12/3/... ‘ 935 24 F2265B 0.77 460 ‘ 0.1 2.8/1 8/1.8 62/27 0.64/0.53
36 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

8OJM/20/4-8/3/... 1440 16 F2265B 1.6 ‘ 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
24 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

8OJM/20/6-12/6/... , 935 14 F2265B 0.77 460 0.1 2.8/1 8/1.8 . 62/27 0.64/0.53
24 F2269R 1.3 , 460 , 0.15 . 4/1.4 14/2.4 68/25 0.70/0.63

40
JMAEROFOIL
Motor Frame Size Schedules:
Two Speed (Full and Half Dual Wound)
I wooDi
AIR MOVEMENT I

400 V/50 Hz/3sp


Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) d.o.l. (A) % cos 0
(kW) rev/mm (kW) (A)
8OJM/20/4-816/... 1440 14 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65

80JM125/6-1213/... 935 28 F22658 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
32 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63

8OJM/25/4-8/3/... 1440 18 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
28 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
32 0132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64

8OJM/25/6-12/6/... 935 18 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
28 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
36 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

80JM/25/48/6/... 1440 10 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
18 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
I 26 Dl 32/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
32 D132/26
:
5.6 730 0.7 : 11.5/3.2 69/13.5 81/51 0.87/0.62
36 0160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58:

8OJM/25/6-12!9/... 12 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53


22 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
: 36 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

8OJM/25/4-8/9/... 1440 12 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
20 Dl 32/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
26 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
36 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58

8OJM/31/2-4/9/... 2910 8 0160/32 14.9 1480 1.86 27.5/5.2 248/42 89/73 0.88/0.70
10 0180/31 17.9 1480 2.24 33/6.6 249/53 89/77 0.87/0.63

9OJM/25/6-12/3/... 935 20 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
28 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
32 0132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

9OJM/25/4-8/3/... 1440 12 F2265B 1.6 700 0.2 3.6/1 22/2.5 84/44 0.76/0.65
20 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
26 Dl 32/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
32 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62

9OJM/25/6-12J6/... 935 10 F2265B 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
18 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
32 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

9OJM/25/4-8/6/... 1440 10 F2269B 2.7 700 0.33 6.7/1.6 37/4 77/48 0.77/0.65
16 0132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
22 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
30 0160/23 8.95 730 1.11 16.6/4.5 I 108/18 87/62 0.89/0.58
32 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
:
9OJM/25/6-12/9/... 935 12 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
26 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60
36 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58

9OJM/25/4-8/9/... 1440 10 Dl 32/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.64
14 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
22 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58
32 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

100JM/25/6-12/3/... 935 12 F22658 0.77 460 0.1 2.8/1 8/1.8 62/27 0.64/0.53
20 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
32 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60

41
JM AEROFOIL
Motor Frame Size Schedules:
wooàs)
AIR MOVEMENT
C
Two Speed (Full and Half Dual Wound)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting . Efficiency Pow
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) COS 0
____________________________________
100JM/25/4-8/3/... 1440
.
12
18
F22698
Dl 32/19
2.7
4.1
700
725
0.33
0.51
1 6.7/1.6
9.5/2.2
37/4
55/9
77/48
79/54
0.77/0.65
0.79/0.64
24 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
32 I D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58

100JM12516-12161... 950 10 F2269B 1.3 460 0.15 4/1.4 14/2.4 68/25 0.70/0.63
: 24 Dl 32/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60
32 0132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58

100JM12514-8161... 1450 10 D132/19 4.1 725 0.51 9.5/2.2 55/9 79/54 0.79/0.641
14 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
22
30
D160/23
D160/30
8.95
13.1
730
730
1.11
1.64
16.6/4.5
27/5.8
108/18
202/32
87/62
87/66
j 0.89/0.58
0.80/0.62
C
100JM/25/6-1219/... 960 18 D132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60
24 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58
34 0160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
36 0160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54

100JM/25/4-8/9/... 1470 8 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
14 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58
22 0160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62

100JM/31/4-8/9/... 1470 8 D132/26 5.6 730 0.7 11.5/3.2 69/13.5 81/51 0.87/0.62
14 D160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58
22 0160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
22 0180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59
28 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
100JM/40/4-8/9/... 1470 12 0160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58
20 0160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
20 0180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59
24 0180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
28 0200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
36 D200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
40 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63
112JM/40/6-12/6/... 960 12 0132/19 3 480 0.37 8.4/2.3 50/6.5 75/39 0.69/0.60
18 Dl 32/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58
24 0160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
32 0160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
112JM/40/4-8/6/... 1470 10 0160/23 8.95 730 1.11 16.6/4.5 108/18 87/62 0.89/0.58
16 0160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
16 0180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59
20 0180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
22 0200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
30 0200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
32 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63

112JM/40/6-12/9/... 960 12 0132/26 4.48 480 0.56 10.5/3.4 63/10 1 79/43 0.75/0.58
20 i 0160/27 6.71 480 0.82 15.6/4.6 I 93/14 81/50 0.76/0.52
26 0160/34 9.33 480 I 1.12 21/5.7 125/18 83/52 0.78/0.54
I 32 0180/35 13.1 485 1.64 28/6.2 1 173/21 86/62 0.78/0.62 I
36 D200/38 I 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
112JM/40/4-8/9/... 1470 10 0160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
10 0180/29 13.8 740 1.72 27/6.2 I 189/31 88/69 0.84/0.59
16 0180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
18 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
24 0200/46 i 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.55
30 W225/M 40 735 6 1 75/22 563/132 :91.5/83.5 0.84/0.63
34 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.63

42
JM AEROFOIL I
Motor Frame Size Schedules: I
woo AIR MOVEMENT
— I
I
Two Speed (Full and Half Dual Wound)
400 V/50 Hz/3Ø
Speed Max. Pitch . Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle () (kW) rev/mm (kW) (A) d.o.l.(A) % cos 0
11 2JM/50/6-1 2/12/... 960 10 D132/26 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58
18 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
24 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
30 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
36 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
11 2JM/50/4-8/1 2/... 1470 8 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
8 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59
14 0180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
16 0200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
22 D200146 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
28 W225/M 40 735 6 75/22 563/132 11.5/83.5 0.84/0.63
32 W225/MF 48 735 9.5 91/26 683/1 56 12.0/84.5 0.83/0.63
36 W250/M 67 735 13 123/37 861/204 12.5/85.0 0.85/0.60
1 25JM/40/6-l 2/6/ , 960 10 Dl 32/26 : 4.48 480 0.56 10.5/3.4 63/10 79/43 0.75/0.58
16 0160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
22 D160/34 9.33 j 480 1.12 21/5.7 125/18 83/52 0.78/0.54
28 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
32 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59

1 25JM/40/4-8/6/... 1470 10 D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
10 ;D180/29 13.8 740 1.72 27/6.2 . 189/31 88/69 0.84/0.59
14 D180/35 17.9 740 1.24 34.2/1.8 238/39 89/70 0.85/0.59
16 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 ‘0.84/0.54
20 D200/46 29.1 740 3.58 55/1 2.5 385/62 90)75 0.85/0.55
26 W225/M 40 735 6 75/22 563/132 11.5/83.5 0.84/0.63
30 W225/MF 48 735 9.5 91/26 683/156 12.0/84.5 0.83/0.63
32 W250/M 67 735 13 123/37 861/204 12.5/85.0 0.85/0.6

1 25JM/40/6-1 2/9/... 960 12 D160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
18 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
22 D180/35 13.1 485 1.64 28/6.2 173/2 1 86/62 0.78/0.62
26 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
32 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.54
34 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
36 W225/MF 28 485 5.6 54/21 351/1 05 9.5/72.5 0.83/0.54

I 25JM/40/4-8/9/... 1470 8 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
10 0200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
16 D200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
20 EW225/M I 40 735 6 75/22 563/132 p1.5/83.5 0.84/0.63
24 W225/MF 48 735 9.5 91/26 . 683/156 2.0/84.5 0.83/0.63
30 :W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.60
34 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

125JM/50/4-8/6/... 1470 10 :D160/30 13.1 730 1.64 27/5.8 202/32 87/66 0.80/0.62
10 D180/29 13.8 740 1.72 27/6.2 189/31 88/69 0.84/0.59
12 D180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
16 0200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
20 0200/46 29.1 740 3.58 55/12.5 385/62 90/75 0.85/0.55
26 W225/M 40 735 6 75/22 563/132 1.5/83.5 0.84/0.63
30 W225/MF 48 735 9.5 91/26 683/156 2.0/84.5 0.83/0.63
32 W250/M 67 735 13 123/37 861/204 J2.5/85.0 0.85/0.60
1 25JM/50/4-8/9/... 1470 8 0180/35 17.9 740 1.24 34.2/7.8 238/39 89/70 0.85/0.59
10 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
16 0200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
22 W225/M 40 735 6 75/22 563/132 1.5/83.5 0.84/0.63
24 W225/MF 48 735 9.5 91/26 683/1 56 2.0/84.5 0.83/0.63
32 W250/M 67 735 13 123/37 861/204 2.5/85.0 0.85/0.60
36 W250/MF 81 735 18 146/45 1022/248 ‘3.0/88.0__0.86/0.6qJ

43
JM AEROFOIL
WOODS
Motor Frame Size Schedules: AIR MOVEMENT
C
Two Speed (Full and Half Dual Wound)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (1 rev/mm (kW) d.o.l. (A) % cos 0
(kW) (A)
125JM/50/6-12/12/.. 960 8 D160/27 6.71 480 0.82 15.6/4.6 93/14 8 1/50 0.76/0.52
14 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
20 0180/35 13.1 485 1.64 28/6.2 173/2 1 86/62 0.78/0.62
24 0200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
28 D200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
30 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
36 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54

125JM/50/4-8/12/... 1470 8 D200/36 20.9 740 2.61 40/9.3 283/47 89/74 0.84/0.54
12 D200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
18 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63
20 W225/MF 48 735 9.5 91/26 683/1 56 92.0/84.5 0.83/0.63
28
32
W250/M
W250/MF
67
81
735
735
13
18
123/37
146/45
861/204
1022/248
92.5/85.0
93.0/88.0
0.85/0.60
0.86/0.60
C
14OJM/40/6-12/6/... 960 10 0160/27 6.71 480 0.82 15.6/4.6 93/14 81/50 0.76/0.52
14 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
20 D180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
24 0200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
30 0200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
30 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
36 W225/MF 28 ! 485 5.6 54/21 351/1 05 89.5/72.5 0.83/0.54

14OJM/50/6-1219/... 960 10 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
16 D180135 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
20 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
24 0200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
24 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
30 W225/MF 28 485 5.6 54/21 351/1 05 89.5/72.5 0.83/0.54
36 W250/M 36 485 7.2 69/26 483/1 43 90.3/74 0.84/0.55

14OJM/50/4-8/9/... 1470 10 D200/46 29.1 740 3.58 55/1 2.5 385/62 90/75 0.85/0.55
14 W225/M 40 735 6 75/22 563/1 32 91.5/83.5 0.84/0.63
16 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.63
22 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.60
26 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

14OJM/50/6-12/12/.. 960 8 D160/34 9.33 480 1.12 21/5.7 125/18 83/52 0.78/0.54
12 0180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
16 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
20 D200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
22 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
26 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54
W250/M 36 485 7.2 69/26 483/143 90.3/74 0.84/0.55
32
34 W250/MF 42 490 8.4 79/28 553/154 90.9/75 0.84/0.55

14OJM/50/4-8/12/... 1470 10 W225/M 40 735 6 75/22 563/132 91.5/83.5 0.84/0.63


12 W225/MF 48 735 9.5 91/26 683/156 92.0/84.5 0.83/0.63
20 W250/M 67 735 13 123/37 861/204 92.5/85.0 0.85/0.60
22 W250/MF 81 735 18 146/45 1022/248 93.0/88.0 0.86/0.60

1 6OJM/40/6-1 2/6/... 960 10 0180/35 13.1 485 1.64 28/6.2 173/21 86/62 0.78/0.62
14 0200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
18 0200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
20 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
22 W225/MF 28 485 5.6 54/21 351/1 05 89.5/72.5 0.83/0.54
28 W250/M 36 485 7.2 69/26 483/1 43 90.3/74 0.84/0.55
30 W250/MF 42 490 8.4 79/28 553/1 54 90.9/75 0.84/0.55
C-,

44
JM AEROFOIL ‘ I

Motor Frame Size Schedules: I


woo
AIR MOVEMENT ]
Two Speed (Full and Half Dual Wound)
400 V/50 Hz/3p
I I
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle () (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
160JM140/6-12/9/... 960 8 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
12 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.54
14 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
18 W225/MF 28 485 5.6 54/21 351/105 89.5/72.5 0.83/0.54
22 W250/M 36 485 7.2 69/26 483/1 43 90.3/74 0.84/0.55
24 W250/MF 42 490 8.4 79/28 553/1 54 90.9/75 0.84/0.55

16OJM/50/6-12/9/... 960 10 D200/38 16.4 490 2.05 35/7.1 230/23 86/71 0.78/0.59
14 D200/46 20.9 485 2.61 46/1 0.7 300/37 87/65 0.75/0.54
14 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
18 W225/MF 28 485 5.6 54/21 351/1 05 89.5/72.5 0.83/0.54
22 W250/M 36 485 7.2 69/26 483/1 43 90.3/74 0.84/0.55
24 W250/MF 42 490 8.4 79/28 553/1 54 90.9/75 0.84/0.55

16OJM/50/6-12/12/... 960 10 D200/46 20.9 485 2.61 46/10.7 300/37 87/65 0.75/0.54
10 W225/M 22.5 485 4.5 44/17 286/85 89/72 0.83/0.54
14 W225/MF 28 485 5.6 54/21 351/1 05 89.5/72.5 0.83/0.54
18 W250/M I 36 485 7.2 69/26 483/143 90.3/74 0.84/0.55
22 W250/MF 42 490 8.4 79/28 553/1 54 90.9/75 0.84/0.55

45
JM AEROFOIL
Motor Frame Size Schedules:
wooàs
AIR MOVEMENT I C.
Two Speed (Full and Other Pole Change)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (j (kW) rev/mm (kW) (A) d.o.I. (A) % COS 0
31JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

31JM/16/4-6/5/... 1420 40 BT5 0.15 ë00 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65

35JM/16/6-8/5/ 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76:

35JM/16/4-6/5/... 1420 38 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
40 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7

4OJM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

4OJM/16/4-6/5/... 1420 24 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
36 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
40 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

45JM/16/6-8/5/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/16/4-6/5/... 1420 14 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
24 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
38 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
40 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

45JM/20/6-8/3/... 900 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/20/4-6/3/... 1420 20 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
32 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
36 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

45JM/20/6-8/6/... 900 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

45JM/20/4-6161... 1420 12 BT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
22 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
38 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
40 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

5OJM/16/6-8/5/... 915 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34


CL
0.60/0.76

5OJM/16/4-6/5/... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
26 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
40 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

50JM120/6-8/3/... 915 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

5OJM/20/4-6/3/... 1420 14 RT5 0.15 900 0.04 0.6/0.3 2.3/0.7 58/30 0.63/0.65
22 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
36 CT5 0.5 900 : 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65

5OJM/20/6-8/6/... 915 40 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

5OJM/20/4-6/6/... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
26 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
40 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

56JM/16/6-8/5/... 900 30 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76
I 40 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

56JM/16/4-6/5/... 1420 18 CT5 0.5 900 0.14 . 1.3/0.65 4.8/1.4 78/48 0.71/0.65
; 28 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

46
JM AEROFOIL ‘‘ I
C Motor Frame Size Schedules:
woo
AIR MOVEMENT

Two Speed (Full and Other Pole Change)


400 V/50 Hz/3ip
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
56JM/20/6-8/3/... 900 36 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76

56JM120/4-6/31... 1420 14 BT9 0.26 900 0.065 0.95/0.45 3.3/1 58/30 0.65/0.7
26 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
36 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58

56JM/20/6-8/6/... 900 28 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76
40 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

56JM/20/4-6/6/... 1420 16 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71 /0.65
26 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58
40 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

63JM/20/68/3/... 900 24 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76
36 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61

63JM/20/4-6/3/... 1420 12 CT5 0.5 900 0.14 1.3/0.65 4.8/1.4 78/48 0.71/0.65
22 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58
36 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

63JM/20/6-8/6/... 900 16 CT5 0.28 . 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76!
• 26 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61
36 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

63JM/2014-6/61... 1420 14 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58
28 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66
36 F2229B 3.5 940 1.04 8/7 46/14 81/80 0.78/0.47

63JM/25/4-6/6/... 1440 34 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


36 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

63JM/25/6-8/9/... 935 40 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

63JM/25/4-6/9/... 1440 28 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


40 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/20/6-8/3/... 900 14 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76
24 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61
36 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

71JM/20/4-6/3/... 1440 12 CT9 0.9 940 0.27 2.4/1.5 10.8/3.2 75/45 0.72/0.58
28 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66
36 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/20/6-8/6/... 900 16 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61
30 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66
36 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/20/4-6/6/... 1440 18 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


30 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

71JM/25/4-6/3/... 1440 32 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66

71JM/2516-8/61... 935 34 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


36 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/25/4-6/6/... 1440 22 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


34 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
36 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

47
JMAEROFOIL I
I WOODS
Motor Frame Size Schedules: AIRMOVEMENT
C
Two Speed (Full and Other Pole Change)
400 V/50 Hz/3p

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.I. (A) % cos 0
71JM/2516-819/... 935 28 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66
36 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

71JM/25/4-6191... 1440 16 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


26 F2229B 3.5 940 1.04 8/7 46/14 81/80 0.78/0.47
36 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

80JM/20/6-8/3/... 935 8 CT5 0.28 700 0.12 1.5/0.67 4.2/1.3 47/34 0.60/0.76
16 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61
30 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66
36 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

8OJM/20/4-6/3/... 1440 18 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


28 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

8OJM/20/6-8/6/... 935 8 CT9 0.48 700 0.2 2.4/1.2 4.9/1.4 58/39 0.50/0.61
18 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66
32 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

8OJM/2014-6/61... 1440 10 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


18 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

8OJM/25/6-8/3/... 935 32 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66

8OJM/25/4-6/3/... 1440 22 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


32 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47

8OJM/25/6-8/6/... 935 24 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


36 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

8OJM/2514-6/61... 1440 12 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


24 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
32 0132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
36 Dl 32/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72

8OJM/25/6-8191... 935 18 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


C
30 F22698 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65
36 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67

8OJM/25/4-6/9/... 1440 8 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


16 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
26 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
30 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72
32 0160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
36 0160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

9OJM/25/6-8/3/... 935 24 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


32 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65

9OJM/25/4-6/3/... 1440 14 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


24 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
32 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71

9OJM/25/6-8/61... 935 14 F2265B 1 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


26 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65
32 D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67

48
JM AEROFOIL
Motor Frame Size Schedules: AIR MOVEMENT

Two Speed (Full and Other Pole Change)


400 V/50 Hz/3ip
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (0)

(kW) rev/mm (kW) (A) d.o.l. (A) % cos 0


9OJM/25/4-6/6/... 1440 14 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
22 0132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
26 Dl 32/24 7 970 2.09 138/5.6 81/23.8 82/75 0.87/0.72
28 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
32 0160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

90JM12516-8/9/... 935 8 F2265B 1 I 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


18 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65
24 0132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67
36 Dl 32/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72

9OJM/25/4-6/9/... 1440 8 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
14 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
18 D132/24 7 970 2.09 13.8/5.6 8 1/23.8 82/75 0.87/0.72
20 0160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
28 Dl 60/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/3/... 935 16 F2265B 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


28 F2269B 1.8 690 0.76 58/3 25/7 73/54 0.61/0.65
32 D132/l9 3 725 1.27 11/3.9 70/1 7.5 73/70 0.54/0.67

100JM/25/4-6/3/... 1440 8 F2225B 2 960 0.6 5.3/2.1 28/7 74/64 0.74/0.66


16 F2229B 3.5 940 1.04 8/4 46/14 81/80 0.78/0.47
24 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
28 7 970 2.09 13.8/5.6 81 /23.8 82/75 0.87/0.72
‘ 30 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
32 Dl 60/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/6/... 950 8 F2265B 700 0.42 3.2/1.7 14/3.9 72/54 0.62/0.66


18 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0. 61/0. 65
24 Dl 32/19 3 725 1.27 11/3.9 70/1 7.5 73/70 0.54/0.67
32 Dl 32/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72

100JM/25/4-6/6/... 1450 8 F2229B 3.5 940 1.04 8/4 46/14 8 1/80 0.78/0.47
14 Dl 32/2 1 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
18 Dl 32/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72
20 Dl 60/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
26 . D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86

100JM/25/6-8/9/... 960 12 F2269B 1.8 690 0.76 5.8/3 25/7 73/54 0.61/0.65
18 • D132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67
26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72
28 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.68
36 DF1 60/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72

100JM/25/4-6/9/... 1470 8 D132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
12 D132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72
14 0160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86

20 D160/34 11.2 950 3.36 21 .8/7.1 142/28 86/83 0.90/0.86


1 OOJM/31/4-6/9/... 1470 8 3132/21 5.6 970 1.64 11/4.5 66/19 84/74 0.88/0.71
12 0132/24 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72
14 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
18 D160/34 11.2 950 3.36 21 .8/7.1 142/28 86/83 0.90/0.86
22 0180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
26 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.86

49
JM AEROFOIL
Motor Frame Size Schedules:
woois
AIR MOVEMENT
C
Two Speed (Full and Other Pole Change)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) d.o.l. (A) % cos 0
(kW) rev/mm (kW) (A)
100JM/40/4-6/9/... 1470 8 0132124 7 970 2.09 13.8/5.6 81/23.8 82/75 0.87/0.72
10 0160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
16 D160/34 11.2 950 3.36 21.8/7.1 142128 86/83 0.90/0.86
18 Dl 80/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
22 D180/35 16.4 960 4.85 30/9.8 195/39 , 88/86 0.90/0.86
28 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.83
34 0200/46 28.3 970 8.39 51 .9/17.1 337/68 90/88 0.89/0.84
38 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.70
40 , W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70

112JM/4016-816/... 960 12 0132/19 3 725 1.27 11/3.9 70/17.5 73/70 0.54/0.67


:
18
20
0132/26
DF132/MK
4.55
5.1
720
710
1.9
2.2
11.9/5.2
12.3/6.5
77.8/20.8:
74/1 9.8
79/73
82/71
0.69/0.72
0.73/0.68
C
26 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
32 DF16O/L 10 710 21/10.5 137/42 87/79 0.80/0.75

112JM/40/4-6/6/... 1470 8 D160/27 8.21 960 2.42 15.6/5 97.5/20 86/83 0.90/0.86
12 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86
14 0180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
18 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.86
24 0200/38 22.4 970 6.64 41 .5/13.3 270/53 89/87 0.88/0.83
28 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
30 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.70
32 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70

112JM/40/6-8/9/... 960 14 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72
16 DF132/MK 5.1 710 2.2 12.3/6.5 74/1 9.8 82/71 0.73/0.68
22 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
26 DF16O/L 10 710 4.3 21/1 0.5 137/42 87/79 0.80/0.75
34 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
36 DF18O/L 17 720 7.3 34/1 7.8 221/71 87/78 0.84/0.76

112JM/40/4-6/9/... 1470 8 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86
10 Dl 80/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
14
20
D180/35
0200/38
16.4
22.4
960
970
4.85
6.64
30/9.8
41.5/13.3
195/39
270/53
88/86
89/87
0.90/0.86
0.88/0.83
C
24 0200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
26 W200ILF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.70
30 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70
34 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
36 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

112JM/50/6-8112/... 960 10 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72
14 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.68
20 DEl 60/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
26 DF16O/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.75
32 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
36 DF18O/L 17 , 720 7.3 34/1 7.8 221/71 87/78 , 0.84/0.76

112JM/5014-61121... 1470 8 0180/29 12.7 960 3.73 23.8/7.5 156/30 . 87/85 0.89/0.85
12 D180/35 16.4 960 4.85 30/9.8 ‘ 195/39 88/86 0.90/0.86
18 D200/38 22.4 970 6.64 41 .5/13.3 270/53 ‘ 89/87 0.88/0.83
22 j 0200/46 28.3 I 970 8.39 51 .9/1 7.1 337/68 90/88 0.89/0,84
24 ‘ W200/LF 31 ‘ 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
28 W200/LFR 38 960 12 70/29 455/1 60 91/85.5 0.86/0.70
32 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
36 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70
C
,

50
JM AEROFOIL
C Motor Frame Size Schedules:
woo”
AIR MOVEMENT * I
Two Speed (Full and Other Pole Change)
400 V/50 Hz/3p

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (0)
(kW) rev/mm (kW) (A) d.o.l. (A) % cos 0
1 25JM/40/6-8/6/... 960 12 D132/26 4.55 720 1.9 11.9/5.2 77.8/20.8 79/73 0.69/0.72
12 DEl 32/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.68
18 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85178 0.78/0.72
24 DF16O/L 10 710 4.3 21/1 0.5 137/42 87/79 0.80/0.75
30 DF180/LM 14 720 6 28/14.6 182/59 I 87/78 0.81/0.77
32 DF18O/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76

1 25JM/40/4-6/6/... 1470 8 D160/34 11.2 950 3.36 21.8/7.1 142/28 86/83 0.90/0.86
8 D180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
12 D180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.86
16 0200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.83
20 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
22 W200/LF 31 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
26 W200/LFR 38 960 12 70/29 455/1 60 91/85.5 0.86/0.70
30 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
32 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70

1 25JM/40/6-8/9/... 960 8 0F132/MK 5.1 710 2.2 12.3/6.5 74/1 9.8 82/71 0.73/0.68
14 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
18 DF16O/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.75
24 DF180/LM 14 720 6 28/1 4.6 182/59 87/78 0.81/0.77
28 DEl 80/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76
30 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
34 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
36 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65
1 25JM/40/4-6/9/... 1470 12 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.83
16 D200146 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
16 W200/LF 31 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
20 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70
24 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
28 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70
34 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.68
36 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

1 25JM/50/4-6/6/... 1470 8 0180/29 12.7 960 3.73 23.8/7.5 156/30 87/85 0.89/0.85
12 0180/35 16.4 960 4.85 30/9.8 195/39 88/86 0.90/0.86
16 D200/38 22.4 970 6.64 41.5/13.3, 270/53 89/87 0.88/0.83
20 D200/46 28.3 970 8.39 51 .9/1 7.1 337/68 90/88 0.89/0.84
22 W200/LF 31 960 10 57/24 370/132 90.8/85.3 0.86/0.70
26 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70
30 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
32 W225/ME 58 980 19 104/44 728/264 92.5/89 0.86/0.70

1 25JM/50/68/9/... 960 8 DF132/MK 5.1 710 2.2 12.3/6.5 74/19.8 82/71 0.73/0.68
14 DF1 60/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
20 DF1 60/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.75
24 DF1 80/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
28 DF1 80/L 17 720 7.3 34/1 7.8 221/71 87/78 0.84/0.76
30 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
34 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
36 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65

1 25JM/50/6-8/1 2/... 960 10 DEl 60/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
16 DF16O/L 10 710 4.3 21/10.5 137/42 87/79 0.80/0.75
22 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
24 DF18O/L 17 720 7.3 34/1 7.8 221/71 87/78 0.84/0.76
26 W200/LEG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
30 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
36 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65

51
JM AEROFOIL
WOODS
Motor Frame Size Schedules: AIR MOVEMENT
C
Two Speed (Full and Other Pole Change)
400 V/50 Hz/3Ø

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency I Power -

Code Motor Rating Current Current Factor


rev/mm Angle () (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0

125JM/50/4-6/12/... 1470 8 D200/38 22.4 970 6.64 41.5/13.3 270/53 89/87 0.88/0.83
12 D200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
14 W200/LF 31 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
18 W200/LFR: 38 960 12 70/29 455/160 91/85.5 0.86/0.70
20 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
24 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70
32 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.68
36 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

1 4OJM/40/6-8161... 960 12 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
16 DF16O/L 10 710 4.3 21/1 0.5 137/42 87/79 0.80/0.75
20
24
DF18O/LM
DF18O/L
14
17
720
720
6
7.3
28/1 4.6
34/17.8
182/59
22 1/71
87/78
87/78
0.81/0.77
0.84/0.76
C,
26 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
30 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
36 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65

1 4OJM/4016-819/... 960 8 DF16O/LM 7.5 710 3.2 16.2/8.2 105/32.8 85/78 0.78/0.72
10 DF16O/L 10 710 4.3 21 /1 0.5 137/42 87/79 0.80/0.75
16 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
18 DF18O/L 17 720 7.3 34/1 7.8 22 1/71 87/78 0.84/0.76
20 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
24 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
30 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65
32 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.65
36 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.65

1 4OJM/50/4-6/9/... 1470 10 0200/46 28.3 970 8.39 51.9/17.1 337/68 90/88 0.89/0.84
10 W200/LF 31 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
14 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70
16 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
20 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70
26 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.68
30 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68
1 4OJM/50/6-8/1 2/... 960 8
14
DF16O/L
DF18O/LM
10
14
710
720
4.3
6
21/10.5
28/14.6
137/42
182/59
87/79
87/78
0.80/0.75
0.81/0.77
C,
16 DF18O/L 17 720 7.3 34/1 7.8 221/71 87/78 0.84/0.76
18 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
22 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
26 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65
28 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.65
34 W225/MF 37 730 18 77/42 539/1 89 91/84 0.76/0.65
36 W250/M 45 730 20 88/48 61 6/216 92/88 0.80/0.66
1 4OJM/50/4-6/1 2/... 1470 8 W200/LF 31 960 10 57/24 370/1 32 90.8/85.3 0.86/0.70
10 W200/LFR 38 960 12 70/29 455/160 91/85.5 0.86/0.70
12 W225/M 47 970 15 86/35 602/210 92/87.5 0.86/0.70
16 W225/MF 58 980 19 104/44 728/264 92.5/89 0.86/0.70
22 W250/M 79 980 26 142/62 994/372 93.2/89.2 0.86/0.68
26 W250/MF 95 985 31 171/74 1197/444 93.5/89.4 0.86/0.68

16OJM/40/6-8/6/... 960 8 DF16O/L 10 710 4.3 21/1 0.5 137/42 87/79 , 0.80/0.75
12 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
14 DF18O/L ‘ 17 720 7.3 34/17.8 ‘ 221/71 87/78 0.84/0.76
16 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65
18 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
24 W200/LFR 27 730 12 55/31 385/140 90/84 0.79/0.65
26 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.65
30 W225/MF 37 730 18 77/42 539/1 89 91/84 0.76/0.65
32 W250/M 45 730 20 88/48 61 6/216 92/88 0.80/0.66

52
JM AEROFOIL I

Motor Frame Size Schedules:


wooI”
AIR MOVEMENT

Two Speed (Full and Other Pole Change)


400 V/50 Hz/3ip

Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) rev/mm (kW) d.o.l. (A) % COS 0
(kW) (A)
16OJM/40/6-8/9/... 960 8 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0.81/0.77
10 DF18O/L 17 720 7.3 34/1 7.8 221/71 87/78 0.84/0.76
10 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0,65
14 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
18 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65
20 W225/M 30 730 13 63/34 441 /1 53 91/84 0.76/0.65
24 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.65
26 W250/M 45 730 20 88/48 61 6/216 92/88 0.80/0.66
30 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

16OJM/50/6-8/9/... 960 8 DF18O/LM 14 720 6 28/14.6 182/59 87/78 0,81/0.77


10 DF18O/L 17 720 7.3 34/17.8 221/71 87/78 0.84/0.76
12 W200/LF6 18.6 720 8 38/22 266/99 89/82 0.78/0.65
14 W200/LF 22 730 9.5 45/25 ‘ 315/113 90/83 0.78/0.65
18 . W200/LFR 27 730 12 55/31 385/1 40 90/84 ‘ 0.79/0.65 i
20 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.65
: 24 W225/MF 37 730 18 77/42 539/189 91/84 0.76/0.65 i
26 W250/M 45 730 20 88/48 61 6/216 92/88 0.80/0.66
30 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

16OJM/50/6-8/12/... 960 8 W200/LFG 18.6 720 8 38/22 266/99 89/82 0.78/0.65


10 W200/LF 22 730 9.5 45/25 315/113 90/83 0.78/0.65
14 W200/LFR 27 730 12 55/31 385/1 40 90/84 0.79/0.65
16 W225/M 30 730 13 63/34 441/153 91/84 0.76/0.65
20 W225/MF 37 730 18 77/42 539/1 89 91/84 0.76/0.65
24 W250/M 45 730 20 88/48 61 6/216 92/88 0.80/0.66
26 W250/MF 55 740 24 107/59 749/266 93/88 0.80/0.66

53
JMAEROFOIL
‘WOODS
I
Motor Frame Size Schedules: AIRMOVEMENT

Two Speed (Full and Other Dual Wound)


400 V/50 Hz/3p
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) % cos 0

45JM/20/6-8/3/... 900 36 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

45JM/20/4-6/3/... 1420 36 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

45JM120/6-8161... 900 40 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

45JM/20/4-6/6/... 1420 40 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

50JM/20/6-8/3/... 915 36 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

50JM120/4-6/31... 1420 36 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

50JM/20/6-8/6/... 915 40 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

5OJM/20/4-6161... 1420 40 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

56JM/20/6-8/3/... 900 36 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

56JM/20/4-6/3/... 1420 36 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75

56JM/20/6-8/6/... 900 40 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

56JM/20/4-6/6/... 1420 36 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
40 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/20/6-8/3/... 900 36 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61

63JM/20/4-6/3/... 1420 30 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
36 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/20/6-8/6/... 900 34 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
36 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

63JM/20/4-6/6/... 1420 22 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
32 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/25/4-6/6/... 1440 26 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
36 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

63JM/25/6-8/9/... 935 32 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
40 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

63JM/25/4-6/9/... 1440 20 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
30 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
40 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

71JM/20/6-8/3/... 900 32 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
36 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71JM/20/4-6/3/... 1440 20 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
32 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

71JM/20/6-8/6/... 900 22 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
36 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71JM/20/4-6/6/... 1440 12 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
20 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

54
JM AEROFOIL “ I

Motor Frame Size Schedules: I


woo
AIR MOVEMENT I
Two Speed (Full and Other Dual Wound)
400 V/50 Hz/3p

Code
Speed Max. Pitch Motor Low Speed Full Load 1 Starling
Current
Efficiency
I
Power
Factor
Motor Rating Current
rev/mm Angle (°) (kW) rev/mm (kW) (A) do]. (A) % cos 0
71JM/25/4-6/3/... 1440 24 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
32 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

71 JM/25/6-8/6/... 935 26 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
36 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

71 JM12514-6161... 1440 16 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
26 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
36 0132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

71JM/25/6-8/9/... 935 20 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61:
34 F2269B 1 680 i 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65
36 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71 /0.65
: .

71JM/25/4-6/9/... 1440 8 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
18 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
32 0132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
36 0132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70

8OJM/20/6-8/3/... 935 22 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
36 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

8OJM/20/4-6/3/... 1440 12 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
22 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

8OJM/20/6-8/6/... 935 12 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
24 F22698 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

8OJM/20/4-6/6/... 1440 12 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69

8OJM/25/6-8/3/... 935 26 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
32 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65

8OJM/25/4-6/3/... 1440 16 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
26 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
, 32 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70

8OJM/25/6-8/6/... 935 16 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
28 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65
36 0132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65

8OJM/25/4-6/6/... 1440 8 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
16 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
26 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
32 0132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
36 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82

8OJM/25/6-8/9/... 935 10 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
• 22 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65
: 32 Dl 32/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
• 36 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67

8OJM/25/4-6/9/... 1440 10 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
20 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
26 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
32 0160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
36 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

55
JMAEROFOIL I
I WOODS
Motor Frame Size Schedules: I AIRMOVEMENT
C
Two Speed (Full and Other Dual Wound)
400 V/50 Hz/3
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) d.o.l. (A) % cos 0
(kW) rev/mm (kW) (A)
9OJM/25/6-8/3/... 935 18 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
28 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65
32 Dl 32/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65

9OJM/25/4-6/3/... 1440 10 F2265B 1.4 940 0.42 3.5/1.25 20/4.2 77/65 0.75/0.75
16 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
28 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
32 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70

90JM/25/6-8/6/... 935 18 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65


28 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
32 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
(
9OJM/25/4-6/6/... 1440 8 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
18 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
22 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
28 0160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
32 0160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

9OJM/25/6-8/9/... 935 12 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65


20 Dl 32/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
30 0132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
36 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71

9OJM/25/4-6/9/... 1440 10 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
16 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
20 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
28 0160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/3/... 935 10 F2265B 0.55 680 0.23 2.3/1.3 6.8/3 48/42 0.72/0.61
20 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65
28 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
32 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67

100JM/25/4-6/3/... 1440 10 F2269B 2.35 940 0.7 5.5/2.2 28/8 78/67 0.79/0.69
20 0132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
24 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
30 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
32 0160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/6/... 950 10 F2269B 1 680 0.42 3.3/1.7 14.2/4 73/54 0.61/0.65


18 D132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
28 Dl 32/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
32 Dl 60/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71

100JM/25/4-6/6/... 1450 10 D132/21 4.5 970 1.34 11.2/4.2 74/24 80/65 0.73/0.70
14 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
20 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
26 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84

100JM/25/6-8/9/... 960 12 0132/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
20 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
30 Dl 60/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
36 0160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67

100JM/25/4-6/9/... 1470 8 D132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
14 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
20 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84
(

56
JMAEROFOIL
WOODSJ
Motor Frame Size Schedules: AIRMOVEMENT

Two Speed (Full and Other Dual Wound)


400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Starting Efficiency Power
Full Load
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) dcl. (A) % cos 0
(A)
1 OOJM/31/4-6/9/... 1470 8 0132/24 5.8 970 1.7 12.8/5.0 80/28 81/70 0.81/0.70
14 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
18 0160/34 11.2 970 3.36 21 .3/7.4 149/48 86/78 0.88/0.84
22 Dl 80/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82
26 0180/35 16.4 980 4.85 30/1 0.3 195/82 88/82 0.89/0.83

1 OOJM/40/4-6/9/... 1470 10 D160/27 8.21 970 2.61 16.2/5.2 113/34 85/75 0.86/0.82
16 D160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84
18 0180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82
22 D180/35 16.4 980 4.85 30/1 0.3 195/82 88/82 0.89/0.83
26 D200/36 20.1 980 5.97 39.5/1 3.5 296/121 88/83 0.84/0.77
34 D200/46 28.3 980 8.21 54/1 8.3 405/164 89/84 0.85/0.77
36 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
40 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73

11 2JM/40/6-8/6/... 960 8 Dl 32/19 2.24 725 0.97 6.4/3.4 42/19 75/64 0.71/0.65
14 0132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
22 0160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
30 Dl 60/34 8.2 720 3.5 20/1 0.4 130/54 82/73 0.72/0.67
32 0160/38 10.5 720 4.4 22.5/1 0.6 124/44.5 82/77 0. 82/0.78

1 12JM/40/4-6/6/... 1470 8 0160/27 8.21 970 2.61 16 .2/5 .2 113/34 85/75 0 .86/0 .82
12 Dl 60/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84
14 0180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82
18 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.83
22 0200/36 20.1 980 5.97 39.5/13.5 296/1 21 88/83 0.84/0.77
28 0200/46 28.3 980 8.21 54/1 8.3 405/164 89/84 0.85/0.77
30 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0,85/0.72
32 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73

11 2JM/40/6-8/9/... 960 8 D132/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
18 0160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
24 0160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67
30 0160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
30 0180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
36 0200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
112JM/40/4-6/9/... 1470 8 , 0160/34 11.2 970 3.36 21.3/7.4 149/48 86/78 0.88/0.84
10 0180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82
14 0180/35 16.4 980 4.85 30/1 0.3 195/82 88/82 0.89/0.83
18 0200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
24 0200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.77
24 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
30 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73
34 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
11 2JM/50/6-8/1 2/... 960 16 0160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
22 Dl 60/34 8.2 720 3.5 20/1 0.4 130/54 82/73 0.72/0.67
28 0160/38 10.5 720 4.4 22.5/10.6 124/44.5’ 82/77 0.82/0.78
28 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72’
34 0200/38 15 730 6.3 30.4/16 ‘ 182/88 87/81 0.82/0.70
36 W200/LFR. 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
11 2JM/50/4-6/1 2/... 1470 8 0180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82’
12 0180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.83
16 0200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
22 0200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.77
24 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
28 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73
32 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
36 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73,

57
JM AEROFOIL
Motor Frame Size Schedules AIR MOVEMENT
wooós
C
Two Speed (Full and Other Dual Wound)
400 V /50 Hz /3 0
Max. Pitch
...

Speed Motor Low Speed Full Load Starting Efficiency Power


Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm (kW) (A) d.o.l. (A) % cosø
125JM/40/6-8/6/... 960 8 Dl 32/26 3.58 730 1.49 9.9/4.9 59/25 76/66 0.70/0.67
14 0160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
20 D160/34 . 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67
i 26 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82177 0.82/0.78
26 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
32 0200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70

125JM/40/4-6/6/... 1470 8 D160/34 : 11.2 970 3.36 21 .3/7.4 149/48 86/78 0.88/0.84
8 D180/29 12.7 970 3.73 23.9/8.2 156/65 87/80 0.88/0.82
12 . D180/35 16.4 980 4.85 30/1 0.3 195/82 88/82 0.89/0.83
16 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
20 0200/46 28.3 980 8.21 54/1 8.3 405/1 64 89/84 0.85/0.77
22 1
W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
26 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73
30 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
32 . W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73

125JM/40/6-8/9/... 960 10 0160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
16 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67
20 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
20 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
26 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
30 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
32 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
36 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66

125JM/40/4-6/9/... 1470 10 0200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
16 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.77
16 W200/LFR 30 975 10 57/24 371/1 44 89.0/83.5 0.85/0.72
20 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73
24 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
30 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73
34 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

125JM/50/4-6/6/... 1470 8
12
0180/29
0180/35
12.7
16.4
970
980
3.73
4.85
23.9/8.2
30/10.3
156/65
195/82
87/80
88/82
0.88/0.82
0.89/0.83
C
14 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
20 D200/46 28.3 980 8.21 54/1 8.3 405/1 64 89/84 0.85/0.77
22 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
26 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73
30 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
32 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73

125JM/50/4-6/9/... 1470 8 D180/35 16.4 980 4.85 30/10.3 195/82 88/82 0.89/0.83
10 D200/36 20.1 980 5.97 39.5/13.5 296/121 88/83 0.84/0.77
16 D200/46 28.3 980 8.21 54/18.3 405/164 89/84 0.85/0.77
16 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
22 W225/M 40 980 13 75/30 488/1 95 90.5/85 0.85/0.73
26 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
30 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73
34 I W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73
j

125JM/50/6-8/12/... 960 14 Dl 60/34 8.2 720 3.5 20/1 0.4 130/54 82/73 0.72/0.67
18 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77
. 0.82/0.78
18 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
22 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
26 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
30 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
34 W225/MF 26 735 11.3 I 56/28 392/168 89.4/86.2 0.74/0.66
36 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69

58
JM AEROFOIL “ I

Motor Frame Size Schedules:


woo
AIR MOVEMENT I
Two Speed (Full and Other Dual Wound)

400V/50 Hz/3p
Speed rMax. Pitch 1 Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) (kW) rev/mm [ (kW) (A) d.o.l. (A) % COS 0

125JM150/4-6/12/... 1470 12 D200146 28.3 980 8.21 54/1 8.3 405/1 64 89/84 0.85/0.77
14 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
18 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73
22 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
26 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73
30 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73

14OJM/40/6-8/6/... 960 i 8 D160/27 5.6 720 1.9 12.8/5.3 83/28 81/73 0.78/0.71
14 0160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67
18 Dl 60/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
18 0180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
22 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
26 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
30 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
34 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
36 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69

14OJM/40/6-8/9/... 960 8 D160/34 8.2 720 3.5 20/10.4 130/54 82/73 0.72/0.67
12 0160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
12 0180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
18 0200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
20 W200/LFR 19 735 8.3 40/21 280/1 26 88.7/84.4 0.77/0.68
24 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
26 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
36 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69
14OJM/50/4-6/9/... 1470 10 0200/46 28.3 980 8.21 54/1 8.3 405/1 64 89/84 0.85/0.77
10 W200/LFR 30 975 10 57/24 371/144 89.0/83.5 0.85/0.72
14 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73
18 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
22 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73
26 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73
14OJM/50/6-8/12/... 960 10 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
10 D180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
14 D200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
18 W200/LFR 19 735 8.3 40/21 280/1 26 88.7/84.4 0.77/0.68
20 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
24 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
32 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69
34 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69
14OJM/50/4-6/12/... 1470 10 W225/M 40 980 13 75/30 488/195 90.5/85 0.85/0.73
14 W225/MF 49 980 16 90/37 585/241 91/86 0.86/0.73
18 W250/M 66 985 22 121/50 787/325 91.5/87 0.86/0.73
22 W250/MF 78 985 26 142/58 923/377 92/88 0.86/0.73
16OJM/40/6-8/6/... 960 8 D160/38 10.5 720 4.4 22.5/10.6 124/44.5 82/77 0.82/0.78
8 0180/35 11.2 730 4.7 23.5/11.7 153/70 84/81 0.82/0.72
14 0200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
16 W200ILFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
18 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.66
22 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
28 W250/M 38 735 15.4 73/36 511/216 91 .2/88.9 0.78/0.69
30 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69
16OJM/40/6-8/9/... 960 8 0200/38 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
12 W200/LFR 19 735 8.3 40/21 280/126 88.7/84.4 0.77/0.68
14 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.66
16 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
: 22 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69
24 W250/MF 40 735
C, 17.3 81/41 567/246 91 .7/88.2 r 0.79/0.69

.1.

59
JMAEROFOIL
Motor Frame Size Schedules:
woos’
AIRMOVEMENT%
C
Two Speed (Full and Other Dual Wound)
400 V/50 Hz/3Ø
Speed Max. Pitch Motor Low Speed Full Load Starting Efficiency Power
Code Motor Rating Current Current Factor
rev/mm Angle (°) d.o.l. (A) % cos 0
(kW) rev/mm (kW) (A)
160JM/50/6-8/9/... 960 8 D200138 15 730 6.3 30.4/16 182/88 87/81 0.82/0.70
12 W200/LFR 19 735 8.3 40/21 280/1 26 88.7/84.4 0.77/0.68
14 W225/M 22 735 9.5 48/24 336/192 89.4/86.2 0.74/0.66
16 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
22 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69
24 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69
16OJM/50/6-8/12/... 960 8 W200/LFR 19 735 8.3 40/21 280/1 26 88.7/84.4 0.77/0.68
10 W225/M 22 735 9.5 48/24 336/1 92 89.4/86.2 0.74/0.66
12 W225/MF 26 735 11.3 56/28 392/168 89.4/86.2 0.74/0.66
20 W250/M 38 735 15.4 73/36 511/216 91.2/88.9 0.78/0.69
20 W250/MF 40 735 17.3 81/41 567/246 91.7/88.2 0.79/0.69

60
JM AEROFOIL
Fan Code: 31 JM/1 6/6/5/... woo cI
I AIR MOVEMENT

315 mm 900 rev/rn in 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D — Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 200 400 600 800 1000
mm in
I wg wg
/hr
3
m 0 500 1000 1500
6

0.20

I
- 0.15

3-

• 0.10

• 0.05
1-

1T
fr2 flftOCOflTOt
flHOCffiTIOfl
IflYEflflflhIOflflI. Inc
0- •0.00

0.025
8) 0.020
0
0 0.015
0
6)
.0 0.010
0
C’)
.0 0.005
0.000
0 0.0
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle ••

—5 —6 —14 —21 —27 —33 —40 —1 —3 —6 —14 —20 —26 —33 —40
8 8
—8 —9 —3 —8 —15 —22 —30 —38 —5 —8 —3 —8 —15 —21 —28 —36
—7 —5 —12 —17 —25 —30 —38 —1 —6 —5 —12 —17 —24 —30 —38
16 16
—4 —7 —6 —10 —13 —18 —24 —30 —1 —6 —6 —10 —13 —17 —24 —30
—2 —7 —8 —14 —16 —22 —25 —30 0 —7 —8 —13 —15 —20 —24 —28
24 40 24 40
—3 —8 —8 —11 —15 —20 —25 —31 — 1 —6 —8 —11 —15 —20 —24 —30

SK11 685 04/03/99


JMAEROFOIL
Fan Code: 31 J Mu 6/4/5/...
4
WOODS AIR MOVEMENT Ii
C
BS575oP
I mm 1420 rev/rn in 5 Blades 50 Hz
EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 200 400 600 800 1000 1200 1400 1600
I I mm in
I I I wg wg
/hr
3
m 0 500 1000 1500 2000 2500
14

• 0.5
12

0.4

0
ci)

c0
U)
0) 8-
a- 0.3
CO
0
I—
C
CO
6
U

0.2
a.

0.1
2

1100 LOll flr


Coo C00100L
00011IRTLCO
IOOEIIIIATI000I. IflC

0 •0.0

0.09 —

0.08 —

0.07 —
Al
0.06 —

.
0.05 — __

0.04 —
—i_ —

0.03 —

0.02 —
::—--.•--- m- ..
< 0.01 —
OF
I 0.00 —

a 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8


q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freauency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle E EE E •TE •E E
—5 —5 —8 —17 —23 —30 —36 —3 —4 —8 —17 —22 —30 —35
8 8
—12 —8 —8 —3 —11 —17 —25 —32 —11 —5 —8 —3 —11 —17 —23 —30

16
—11
—10

—3
—4
—5

—6
—9
—7

—9
—5
—6

—11
—14
—11

—16
—20
—14

—20
—27
—21

—25
—33
—26

—29
16
—9
—8

—2
—1
—2

—4
—8
—7

—9 —11
—5
—6
—13
—11

—15
—19
—14

—18
—27
—21

—23
—33
—26

—27
C
24 40 24 40
—6 —4 —9 —9 —13 —17 —23 —28 — —4 —1 —8 —9 —13 —16 —22 —27

5K11686 04/03/99
JM AEROFOIL
Fan Code: 31 JM/i 6/2/5/...
I WOODS’S
c I AIR MOVEMENT

315 mm 2840 rev/mm 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000
I I I I I mm in
I I I I wg wg
/hr
3
m 0 1000 2000 3000 4000 5000
2.0
50-

40
1.5

(6

9)
30
U)
a)
0

Cu 1.0
0
I—

Cu
IL 20

- 0.5

10

Q •0.0

0.7
a) 0.6
0 0.5
0
0
0.4
0) 0.3
.0
0 0.2
Co
.0
0.1
0.0
0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 2k 4k 8k Angle — E -EE EE E
—12 —7 —6 —5 —9 —17 —24 —30 —10 —7 —3 —4 —8 —16 —24 —29
8 8
—16 —13 —8 —8 —3 —11 —17 —25 —14 —12 —6 —8 —3 —11 —16 —23
—14 —11 —4 —9 —5 —14 —20 —27 —13 —11 —1 —8 —5 —13 —20 —27
16 16
—15 —10 —5 —7 —7 —11 —15 —21 —13 —10 —2 —7 —6 —11 —15 —21
—4 —6 —10 —12 —17 —20 —5 —9 —11 —15 —18 —23
40

24 40
—9 —7 —5 —10 —10 —14 —18 —23 — —7 —6 —1 —9 —10 —13 —16 —22

SK11 687 04/03/99


JM AEROFOIL
WOODS’
Fan Code: 35J Mu 6/6/5/... C AIR MOVEMENT

355 mm 900 rev/mm 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 200 400 600 800 1000 1200 1400 1600
mm fl
wg wg
/hr
3
m 0 500 1000 1500 2000 2500
7.

• 0.25
6

0.20

a
0
a
D
a,
a 4.
0 • 0.15
a
0
I—
C 3-
a
U
0.10
0.

- 0.05

n no C OMPOL
flUOCIATIOfl
IflTOlflflTIOflfll. Inc.

0 0.00

0.040
a 0.035
0
0.030
ci 0.025
-o 0.020
a
.0 0.015
0
Cl) 0.010
.0
0.005
0.000
0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - -
Angle • - •

—6 —6 —4 —10 —18 —25 —32 —41 —5 —4 —10 —18 —24 —32 —40
8 8
—10 —9 —3 —7 —14 —19 —28 —35 —8 —8 —3 —7 —14 —19 —27 —33

16
—6
—6
—7
—7
—4
—6
—12
—8
—14
—11
—19
—15
—25
—22
—30
—26
16
—3
—3
—6
—7
—4
—6
—12
—8

—11
—13
—11

—15
—18
—14

—19
—25
—22

—24
—30
—26

—30
C
—4 —6 —6 —11 —16 —21 —25 —32 —2 —6 —6
24 40 24 40
—4 —7 —6 —11 —14 —18 —25 —30 — —1 —6 —6 —11 —14 —18 —24 —29

SK11688 04/03/99
JM AEROFOIL
Fan Code: 35JM/1 6/4/5/...
WOODS
c AIR MOVEMENT

355 mm 1420 rev/mm 5 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500
mm in
wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
16
0.6

14

0.5
12

a
10- -0.4
(0
CO
0)
0
a 8-
0 - 0.3
H
0
a
L1
6
0
• 0.2

4.

• 0.1
2

0 0 •0.0
0.0 0.2 0.4 0.6 0.8 1.0 1.2
0.16

I
0.14
0.12
0.10
0.08
0.06
0.04
0.02
0.00
0.0 0.2 0.4 0.6 0.8 1.0 1.2
q — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.tJse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle - -
E r rr
—7 —5 —5 —13 —20 —27 —35 —6 —5 —4 —5 —13 —20 —27
8
—14 —10 —7 —3 —10 —16 —22 —31 —12 —8 —7 —3 —9 —16 —20 —29
12 —6 —6 —5 —13 —15 —21 — —10 —3 —6 —5 —12 —14 —21 —27
16 16
—10 —6 —7 —6 —9 —12 —17 —24 —9 —3 —6 —6 —9 —12 —17 —24

24 40
—5 —6 —7 —8 —14 —18 —23 —28
24 40
a —5 —7 —7 —13 —17 —21 —26
—7 —5 —8 —7 —12 —16 —21 —27 — —5 —2 —7 —7 —12 —16 —20 —26

SK11689 04/03/99
JM AEROFOIL
Fan Code: 35J Mu 6/2/5/...
woo AIR MOVEMENT

355 mm 2840 rev/mm 5 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000
mm in
wg wg
/hr
3
m 0 2000 4000 6000 8000
700
70

2.5
600
60

500 2.0
50
CO
0

D
C.
0 400
0
6) 40
1.5
CO
0
I
C 300 30
CO
IL

0
1.0

200 20

0.5
100 10

novimErIr
vno ccnrot
ITCIOCIATIOA
inrcvnnvionnr. mc.
0 0 0.0
0.0 0.5 1.0 1.5 2.0 2.5
1.2
1.0
0.8
C
0.6
0.4
0.2
I 0.0
0.0 0.5 1.0 1.5 2.0 2.5
q — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 4k Angle - - - - -—

—13 —9 —7 —5 —6 —13 —21 —28 —10 —8 —5 —4 —5 —12 —21 —27


8
—17 —14 —10 —7 —3 —10 —16 —22 —15 —14 —8 —7 —3 —9 —15 —20
—12 —12
16
—11 —11
—6
—7
—7
—7
—5
—7
—13
—10
—16
—13
—22
—17
16
—11
—10
—12
—11
—3
—4
—6
—7
—5
—6
—12
—9
—16
—13
—21
—17 L
—8 —9 —14 —19 —24 —6 —5 —6 —7 —8 —13 —17 —22
24 40 24 40
—8 —8 —6 —8 —8 —13 —17 —22 —5 —7 —3 —8 —8 —13 —16 —21

SK11690 04/03/99
JM AEROFOIL
Fan Code: 4OJM/1 6/6/5/... WOODS AIR MOVEMENT

400 mm 900 rev/mm 5 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor instaflationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500
I I I I I I mm in
I I I wg wg
/hr
3
m 0 500 1000 1500 2000 2500 3000 3500 4000
8
0.30

7.

0.25
6

a
c.. a ‘0.20
D
C/)
a
0
a 4
0 0.15

a
U
3
0
0.10

0.05
2S

nnDCOA\

0I
IflTCI)flflTIOflAt Inc
0 0.00

— Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -•
1k - Angle r - -• TE -:;-- ——

—6 —7 —4 —8 —15 —22 —30 — —4 —6 —4 —8 —15 —21 —30 —38


8 8
—9 —9 —5 —5 —11 —16 —24 —31 —6 —8 —5 —5 —11 —16 —23 —29
—6 —7 —9 —12 —17 —24 —30 —2 —5 —7 —9 —11 —16 —24 —30
16 16
—4 —7 —8 —9 —11 —14 —20 —24 —1 —6 —8 —9 —11 —13 —20 —24
—3 —7 —8 —11 —14 —18 —23 —28 —1 —6 —8 —10 —13 —16 —21 —26
24 40 24 40
—3 —7 —8 —11 —14 —17 —23 —28 — 0 —6 —8 —11 —14 —17 —22 —27

SK11691 04/03/99
JMAEROFOIL
I WOODSj
Fan Code: 4OJM/1 6/4/5/... C
AIR MOVEMENT *‘

mm 1420 rev/mm 5 Blades 50 Hz


Bs5750ptl
V
EN 29001
So 9001
.

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000 3500
I I I I mm in
I I I I wg wg
/hr
3
m 0 1000 2000 3000 4000 5000 6000
08
20

- 0.7

15 0.6

cc
0
0 • 0.5 (
D
Cf>
C’)
0
fl
100 0.4
10-
0
I—

cc
U
• 0.3

5. 0.2

• 0.1
r
moyc fEAT
ff0 000TROL
ITO C IAT lOT
:nnnTIonn). Inc.
2
I_
0- -0.0

0.30

o
0.2C
, A) +
h—:.no
—____J__ —-—---
C
• 0.15
==zZ
.0 - 32°
o 0f.
C0 240
.0
—i--I
cC 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - -.
.
4k Angle •E - -EE -•E -E -• -E
—10 —7 —6 —5 —11 —18 —25 —33 —5 —5 —II —17 —25 —32
8 8
—13 —9 —7 —4 —8 —13 —19 —26 —11 -6 —7 —4 —8 —13 —17 —24
—10 —4 —7 —7 —11 —14 —20 —26 —8 —2 —7 —7 —10 —13 —20 —26
16 16
—10 —5 —7 —8 —10 —12 —16 —22 —8 —2 —7 —8 —9 —12 —16 —22
—4 —6 —8 —9 —14 —17 —21 —26 —4 —8 —9 —13 —15 —19 —24
24—40 24 40
—6 —5 —8 —9 —12 —15 —20 —26 — —4 —2 —7 —9 —12 —15 —19 —25

SK11692 04/03/99
JM AEROFOIL
Fan Code: 40J Mu 6/2/5/...
WOODS
AR MOVEMENT
C
ISO 9001
400 mm 2840 rev/mm 5 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000
I I I I I I I mm in
I I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000
80
- 3.0

70

• 2.5
60

(6
0
6) 50- 2.0
(/)
(0
ci)
a
cc 40 -

0 1.5
I—
C
cc
U
30
a.
1.0

20

0.5
10
r
moVIffilny
(no cGATOOL
flUOcIATIOII
IflTEI%PflTIDflflI. bc.

0 0 0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
2.5
( 2.0
40°
1.5
1.0 —32°
0.5
0.0 I 18 I 16°
I 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freauency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - - . -
-
Angle r - - r
—14 —10 —8 —7 —5 —12 —19 —26 —11 —9 —5 —5 —5 —10 —19 —25
8 8
—16 —14 —9 —8 —5 —8 —14 —19 —14 —13 —6 —7 —4 —7 —12 —17

—12 —11 —5 —8 —8 —11 —15 —21 —10 —10 —2 —7 —6 —10 —14 —20
16 16
—12 —11 —5 —8 —9 —10 —13 —17 —10 —10 —2 —7 —8 —10 —12 —16

—8 —5 —7 —9 —11 —15 —18 —22 —6 —5 —5 —8 —9 —13 —16 —20


24 40 24 40
—8 —7 —6 —9 —10 —13 —17 —21 — —6 —7 —2 —8 —10 —13 —15 —20

SK11693 04/03/99
JM AEROFOIL
Fan Code: 45JM11 616151... I
AIR MOVEMENT

450 mm 900 rev/mm 5 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Quoted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000
I I I I mm in
H wg wg
/hr
3
m 0 1000 2000 3000 4000 5000

0.35

8
- 0.30

0.25
(U 6
0

D
C
0
0
a) 0.20

CU
0
I—
4
a 0.15
LI

- 0.10

• 0.05

movcmcnr
(lID COCTROL
nifoclahlon
flTERflflTIOflflI. Inc.
0 0 •0.00
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.12
a)
C
0.10
0.08
Cr
0
0
a) 0.06
.0
0 0.04
0
.0 0.02
0.00
0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle -‘E -E -E —E
—6 —8 —4 —7 —13 —20 —28 —36 —4 —8 —4 —7 —13 —20 —27 —34
8 8
—7 —9 —8 —5 —9 —14 —20 —26 —6 —9 —8 —5 —9 —13 —20 —25
—7 —8 —8 —11 —16 —23 —30 —8 —11 —16
16
—3 —7

—7
—10

—11
—10

—11
—Ii

—14
—14

—16
—19

—21
—22

—24
16
—2

—2
7
—8

—7
8
—10

—11
—10

—11
—11

—14
—14

—16
—22
—18

—21
—28
—20

—23
C
24 40 24 40
—3 —7 —10 —11 —14 —16 —22 —27 — —2 —7 —10 —11 —14 —16 —21 —25

SK11694 04/03/99
JM AEROFOIL
Fan Code: 45JM/20/6/3/...
woo CI
AIR MOVEMENT

450 mm 900 rev/mm 3 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

ft’/min 0 500 1000 1500 2000 2500 -

mm in
I I I I wg wg
m’/hr 0 1000 2000 3000 4000
7

- 0.25
6

020
Cu

a)
C’)
C’,
a) 4
0 - 0.15
(0
0
I—

Cs
3
LL

0.10

0.05

flirt
movemEnt
Cnn OOrItnOi
nuocmTIoiI
IflTIRflflTIOfltCI Inc.
0 •0.00

C’

q. — Volume Flow (m’/s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • - -. -•
8k Angle -E -TEE E -E -W EE E
—15 —9 —3 —5 —14 —23 —32 —42 —13 —9 —3 —5 —13 —22 —31 -40
8 8
—10 —8 —5 —6 —11 —14 —20 —24 —7 —8 —5 —6 —11 —13 —18 —22

16
—8 —6 —4 —9 —14 —17 —23 —28
16
s —4 —9 —13 —17 —22 —27
—6 —7 —5 —8 —12 —16 —22 —27 —4 —7 —5 —8 —12 —15 —22 —26
—5 —5 —8 —10 —13 —17 —21 —25 —3 —5 —8 —10 —13 —16 —19 —22
24 36 24 36
—4 —6 —7 —10 —13 —17 —24 —29 — —2 —5 —7 —10 —13 —16 —23 —27

SK11695 04/03/99
JM AEROFOIL
WOODS
Fan Code: 45JM12016161... AIR MOVEMENT
C
450 mm 900 rev/mm 6 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000
I I I I mm in
I I I I wg wg
/hr
3
m 0 1000 2000 3000 4000 5000
0.40
10

0.35

8
0.30

a
0
• 0.25
D 6
C,)
‘I)
0
a • 0.20
0
I—
C
S
1 40 4
0.15
0.

•0.10

005

flflD COnTROL
flFSOGIATIOfl
IflTCflflflTIOflflI.

0 •0.00

0.14

0
2) 0.12
0.10
C
0
0.08
2) 0.06
.0
0
C’,
0.04
.0
0.02
0.00
0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - - -— — Angle - - - - ‘

—13 —10 —3 —5 —13 —22 —32 —42 —11 —8 —3 —5 —13 —21 —32 —41
8 8
—15 —10 —5 —4 —10 —15 —24 —31 —14 —8 —5 —4 —10 —15 —23 —29

—10 —6 —4 —8 —11 —16 —24 —29 g —5 —4 —8 —11 —15 —24 —29


16 16
—11 —6 —5 —7 —10 —13 —20 —24 —10 —5 —5 —7 —10 —13 —20 —23

—6 —6 —5 —9 —13 —16 —21 —26 —5 —9 —12 —15 —20 —25


24 40 24 40
—7 —6 —6 —8 —12 —15 —23 —28 — —5 —4 —6 —8 —12 —15 —22 —27

SK11696 04/03/99
JM AEROFOIL
Fan Code: 45JM/1 6/4/5/... AIR MOVEMENT

450 mm 1420 rev/mm 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000
I I I I I mm in
I I wg wg
/hr
3
m 0 2000 4000 6000 8000
-1.0
25

20- -0.8

(U
0
U)
D
0
15- -0.6
0
ci)
0
(U
0

C
(U
U -0.4

0.

5 02

mOYUfl%.
(no COATROL
(COCIATICA
IflT(RRATIOAAI. InC
0- -0.0

ci)
0
U
0
ci)
.0
0
0
.0

U-

— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle -• -
r 4k
—11 —7 —8 —4 —9 —16 —23 —31 —10 —5 —7 —4 —9 —16 —22 —29
8 8
—13 —7 —9 —5 —6 —11 —16 —22 —13 —6 —9 —5 —6 —9 —16 —21
—9 —7 —9 —13 —19 —26 —8 —4 —9 —7 —9 —13 —18 —24
16 16
—10 —3 —9 —10 —11 —12 —16 —20 —10 —3 —9 —10 —11 —12 —15 —18
—5 —9 —11 —15 —16 —20 —24 —5 —9 —11 —15 —16 —19 —23
24—40 24 40
—6 —4 —8 —11 —13 —15 —20 —25 — —5 —4 —8 —11 —13 —15 —19 —23

5K11697 04/03/99
JM AEROFOIL
WOODS
Q Fan Code: 45JM/20/4/3/...
450 mm 1420 rev/mm 3 Blades 50 Hz
ISO 9001
- AIR MOVEMENT
C -

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000 3500 4000
nm
-

I I I I in
I - wg wg
/hr
3
m 0 1000 2000 3000 4000 5000 6000 7000

0.7

15 0.6

0.5
cc
0
a)
C
D

04

cc
0
I—

-0.3
LI

5 -0.2

0.1
iI,i

1
r .
movln,Enr
flAb COnTROl
TITOCIATIOT
InTTrnTTCiOfln,. Inc.
0 0.0

0.30
cc
0
0.25
0.20
(
0 0.15
a)
-Q
0 0.10
C),
-D 0.05
0.00
0.0 0.5 1.0 1.5 2.0
q, — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -
2k 4k r Angle 125 -

—16 —15 —6 —3 —8 —17 —25 —36 —13 —14 —6 —3 —8 —16 —24 —33
8
—10 —11 —6 —6 —7 —12 —15 —21 —8 —11 —6 —6 —7 —12 —13 —19
—7 —5 —7 —12 —16 —20 —26 —6 —6 —5 —7 —12 —15 —19 —25
16 16
—6 —8 —6 —7 —10 —14 —17 —24 —4 —8 —6 —7 —10 —14 —17 —23
—7 —6 —10 —12 —16 —19 —23 —7 —6 —10 —12 —15 —17 —21
24 36 24 36
—4 —9 —6 —9 —11 —15 —20 —26 — —1 —9 —6 —9 —11 —15 —18 —24

SK11698 04/03/99
JM AEROFOIL
Fan Code: 45JM12014161...
WOODS
AIR MOVEMENT

Iso 9001
450 mm 1420 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
fi 0 1000 2000 3000 4000 5000
mm in
I wg wg
/hr
3
m 0 2000 4000 6000 8000
1.0
25

20 0.8

(N,

15 0.6

o. -0.4

5- -0.2

T
fr&gVErnER
AAD COTROL
?1OCIATIOA
ATERAAYIOAAI, Inc.
0• •0.0

0.6
0.5
0.4
0.3
0.2
0.1
0.0
0.0 0.5 1.0 1.5 2.0 2.5
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle r - E - 1k 8k Angle r - r
—17 —12 —6 —4 —7 —17 —24 —36 —15 —10 —6 —4 —7 —16 —24 —34
8 8
—19 —13 —6 —5 —5 —13 —17 —26 —17 —11 —6 —5 —5 —12 —16 —25
—14 —6 —4 —8 —9 —13 —18 —26 —13 —5 —4 —8 —9 —13 —18 —25
16 16
—15 —7 —5 —7 —8 —12 —14 —22 —14 —5 —5 —7 —8 —12 —14 —21
—7 —6 -6 —9 —11 —15 —19 —24 s —5 —6 —9 —10 —14 —17 —22
24—40 24 40
—9 —6 —6 —9 —9 —14 —17 —25 — —6 —3 —6 —9 —9 —14 —16 —24

SK11699 04/03/99
JM AEROFOIL
WOODS
Fan Code: 45JM/1 6/2/51... I C AIR MOVEMENT

450 mm 2840 rev/mm 5 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000
mm in
wg wg
/hr
3
m 0 5000 10000 15000

3.5

80
3.0

2.5
60
a-
a
D
C
0
0
a 2.0
0

0
I—
C
40
Cu 1.5
U

C-

1.0

20

0.5

0 0.0

a
0
(-
0
a
.0
0
(1)
.0

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Octave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)
Pitch
Angle 1k
Pitch
Angle - E -
—15 —11 —7 —8 —5 —10 —17 —24 —14 —11 —5 —7 —4 —9 —15 —21
8 8
—15 —14 —8 —9 —6 —7 —11 —16 —15 —14 —6 —9 —6 —5 —10 —15

16
—12
—13
—9
—10

—5
—5
—3

—6 —10
—9
—9
—8
—11

—12
—9
—11

—15
—13
—13

—17
—19
—16

—20
16
—12

—7
—10

—5
—5
—3

—6
—9
—9

—9
—8
—10

—12
—9
—11

—15
—12
—12

—16
—18
—14

—19
C
24 40 24 40
—9 —6 —5 —9 —12 —14 —16 —21 — —8 —6 —5 —9 —11 —14 —15 —19

SK11700 04/03/99
JMAEROFOIL
Fan Code: 45JM/20/2/3/.
.
1
Iso 9001
450 mm 2910 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000
I I mm in
I I •1 wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000
80 -

3.0

70

2.5
60

a
0:. 2.0
a 50
0
a
1)
0
(0 40
0 1.5
I—

a
U
30’
0
• 1.0

20

- 0.5
10-

rnovmn,%.
(nb CQfltROt
n%nocrnTIon
IflflRflflTiOflflt. Inc.
0- -0.0

‘DL

II-l

I ,, (I

Sound Data B5848 Part 2 1985:


-i
0.5 1.0 1.5
q —
2.0 2.5
Volume Flow (m
/s)
3
3.0

Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
3.5 4.0 4.5

specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -
- 1k 8k Angle 1k

—19 —16 —15 —6 —4 —8 —18 —26 —16 —14 —14 —6 —3 —7 —16 —23
8 8
—16 —10 —11 —6 —6 —7 —13 —15 —14 —8 —11 —6 —6 —6 —11 —13

—10 —8 —7 —5 —8 —12 —16 —20 —8 —6 —7 —5 —7 —12 —15 —19


16 16
—12 —7 —9 —6 —8 —10 —15 —18 —11 —4 —8 —6 —8 —10 —14 —17

—8 —5 —8 —7 —11 —13 —17 —20 —7 —4 —8 —7 —11 —12 —15 —17


24 36 24 36
—10 —4 —10 —7 —10 —12 —16 —20 — —8 —2 —9 —7 —10 —11 —15 —18

SK117O1 04/03/99
JM AEROFOIL I
Fan Code: 50JM12016131... woo AIR MOVEMENT
I (
500 mm 915 rev/mm 3 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 500 1000 1500 2000 2500 3000 3500 4000
L mm in
wg wg
/hr
3
m 0 1000 2000 3000 4000 5000 6000 7000
8-
- 0.30

70
7.

0.25
60
6

(0

a) 50 0.20
(
(I)

0)
a-
40
(0 4.
a - 0.15
I
C
(0
U
30 3

- 0.10

20 2-

- 0.05
10

(AD COflTDOt

fltflflflhloflfl(. Inc.
0 0- 0.00
0.0 0.5 1.0 1.5 2.0

‘0 (
0
0
0
0)
.0
0
Q)
.0

q — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -
-7 Angle 4k 8k
—16 —10 —4 —4 —13 —21 —30 —41 —13 —9 —4 —4 —13 —21 —29 —39
8 8
—8 —7 —6 —6 —11 —13 —18 —23 —5 —7 —6 —6 —11 —13 —16 —20
—8 —5 —5 —9 —14 —18 —22 —27 —6 —5 —5 —9 —14 —17 —21 —26
16 16
—5 —6 —6 —9 —13 —17 —22 —26 —3 —6

-
—6 —9 —13 —16 —21 —25
—5 —8 —9 —13 —17 —20 —25 —5 —8 —9 —13 —15 —18 —22
24 36 24 36
—4 —6 —8 —10 —14 —18 —23 —28 — —1 —6 —8 —10 —14 —17 —22 —26

SK11704 04/03/99
JM AEROFOIL
ç Fan Code: 5OJM/20/6/6/... woo AIR MOVEMENT

Iso 9001
500 mm 915 revlmin 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000
( I I I mm in
I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000
12-

04
10

Ca Ii)
8
0.3
D
(I)
0
ci)

a
115 6-
0
I—
C
a 0.2
U-

a. 4.

- 0.1
2

nrennflTlonnI. lnc

0- •0.0

ci 0.25
0.20
0.15
0.10
0.05
0.00
a 0.0 0.5 1.0 1.5 2.0 2.5
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E E 1k 4k 8k Angle E E
—16 —10 —5 —3 —11 —20 —30 —40 —14 —9 —5 —3 —11 —19 —29 —38
8 8
—16 —9 —6 —4 —9 —15 —22 —29 —15 —7 —6 —4 —9 —14 —20 —27
—11 —6 —4 —7 —12 —16 —24 —30 —10 —4 —4 —7 —11 —15 —23 —29
16 16
—11 —5 —5 —7 —11 —14 —19 —24 —9 —4 —5 —7 —11 —14 —19 —23
—6 —6 —6 —9 —12 —16 —19 —24 —5 —4 —6 —9 —12 —15 —18 —22
24 40 24 40
—6 —5 —7 —9 —13 —16 —22 —26 — —4 —3 —7 —9 —13 —15 —20 —25

5K11705 04/03/99
JMAEROFOIL
Fan Code: 5OJM/1 6/4/5/... 1 C
woos’
LAiR MOVEMENT’%

“0 mm 1420 rev/mm 5 Blades 50 Hz


EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000
mm in
wg wg
m
/
3 hr 0 2000 4000 6000 8000 10000 12000
1.2
30

1.0
25

(0 0.8
0
ci)
20
(
D
C,)
C,)
a)
0
CO 15 0.6
0
I
C
(9
LJ

lo. 0.4

5. 0.2

0 0- •0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
0.8

0
0.7
0.6
C
c 0.5
0.4
. 0.3
a
(,) 0.2
-a
< 0.1
I 0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
q, — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -. Angle
—13 —9 —8 —3 —8 —14 —22 —29 —12 —7 —8 —3 —8 —14 —21 —27
8 8
—15 —7 —10 —6 —6 —10 —15 —21 —15 —6 —9 —6 —6 —8 —14 —19

16
—12
—11
—7
—3
—10
—9
—4
—9
—8
—11
—12
—12
—18
—16
—25
—19
16
—11
—11
—7
—3
—10
—9
—4
—9
—8
—11
—12
—12
—18
—15
—23
—18 C
—5 —9 —10 —13 —14 —18 —21 —4 —9 —10 —13 —14 —17 —20
24 40 24—40
—6 —4 —9 —10 —13 —15 —19 —24 —6 —3 —9 —10 —13 —15 —18 —22

SK11706 04/03/99
JMAEROFOIL
WOODS
c . Fan Code: 5OJM/20/4/3/... AIR MOVEMENT

BS5ThOPtl
EN 29001
Iso 9001
500 mm 1420 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000
I I I mm in
I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000
200 0.8
20-

- 0.7

15 0.6

r. 0..
11)
0.5
(I)
a)
0..
100 o. -0.4
C
I—
C
a
Li..
0.3

5 0.2

0.1
r
7N\
nil’

nAD COATROI
TITOCIATICA
II1TETA AT 10 A A I.
0- 0.0
3.0
0.5

0.0 0.5 1.0 1.5 2.0 2.5 3.0


q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle .
Angle E •E E 7E
—16 —15 —7 —3 —6 —16 —24 —34 —13 —14 —7 —3 —6 —15 —23 —32
8 8
—8 —10 —6 —6 —7 —12 —15 —20 —6 —10 —6 —6 —7 —12 —13 —18
—8 —7 —5 —7 —11 —16 —19 —25 —6 —7 —5 —7 —11 —15 —18 —24
16 16
—5 —8 —6 —8 —11 —15 —18 —24 —3 —8 —6-8—11—15 —17 —23
—5 —8 —6 —10 —11 —15 —18 —23 —3 —7 —6 —9 —10 —14 —17 —20
24 36 24 36
—4 —9 —6 —9 —12 —16 —20 —26 — —1 —8 —6 —9 —12 —16 —19 —24

SK11 707 04/03/99


JM AEROFOIL
Fan Code: 5OJM/20/4/6/... WOODS’Sib

C AIR MOVEMENT

500 mm 1420 rev/mm 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000
mm in
F I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000
1,2
30

25 1.0

a 20 0.8
0
a
Lb
Lb
ci)

a 15 0.6
0
I
C
a
L1

0
10 -
- 0,4

5 - 0.2

0• -0.0

0.9
a 0.8
0.7
0
0
0.6
0.5
a
.0
0.4
0 0.3
Lb
.0 0.2
0.1
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
q) — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall leveLUse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E E E 7E E iE
—20 —12 —8 —3 —6 —14 —23 —34 —17 —10 —8 —3 —5 —13 —22 —32
8 8
—19 —12 —7 —5 —5 —12 —16 —24 —18 —10 —7 —5 —5 —11 —15 —23
—15 —6 —5 —7 —9 —13 —18 —26 —14 —5 —5 —7 —8 —13 —18 —25
16 16
—14 —6 —6 —7 —8 —13 —15 —21 —13 —4 —6 —7 —8 —13 —15 —20
—7 —9 —11 —14 —18 —22 ‘ —10 —13 —16 —21
24 40 24—36
—7 —5 —8 —9 —11 —15 —18 —24 —5 —3 —7 —9 —II —15 —17 —23

SK11708 04/03/99
JMAEROFOIL
I WOODS
c Fan Code: 5 OJ M/2 0/2/3/... AIR MOVEMENT % I
BS5750P
EN 29001
SO 9001
500 mm 2910 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000
I I mm in
i I I I wg wg
/hr
3
m 0 5000 10000 15000 20000
80 -

3.0

70

2.5
60

cc
k) 2.0
ci) 50
cci
U)
a)
0
cc 40
9) 1.5
C
cci
LI
30-
9).
-1.0

20

- 0.5
10

movimpRy
000 0000ROL
0050000IOL1 -‘
I0000nntI000,. Inc
0- 0.0

4.0 -
3.5 -

0
3.0
- 2.5
- 2.0
1.5 24
-

0
ci, 1.0 -zz
-9) — I
< 0.5
I 0.0
0 2 3 5
— Volume Flow 3
(m
/ s)
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E Angle
-. 1k — E
—21 —16 —15 —8 —4 —7 —17 —25 —18 —14 —14 —7 —3 —6 —16 —22
8 8
—15 —8 —11 —7 —7 —8 —13 —15 —14 —5 —10 —6 —7 —7 —11 —12
—11 —9 —7 —5 —6 —12 —17 —20 —10 —7 —6 —5 —8 —11 —16 —19
16 16
—12 —6 —9 —6 —9 —11 —16 —19 —10 —3 —8 —6 —9 —11 —15 —17
—9 —5 —8 —7 —11 —12 —16 —19 —7 —4 —8 —7 —10 —10 —14 —16
24 36 24 36
—9 —4 —10 —7 —10 —12 —17 —21 — —7 —2 —9 —7 —10 —12 —16 —19

SKi 1710 04/03/99


JM AEROFOIL
Fan Code: 50JM12012161...
woo cI

fl AIR MOVEMENT

500 mm 2910 rev/mm 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
mm in
I wg wg
/hr
3
m 0 5000 10000 15000 20000
120-

100-

CO 80
a 3 V

D
Cd)

CO 60 -

0
I

CO
2
U-

a. 40

20

0 0
0 1 2 3 4 5 6 7
8
6)
0
7
6
(
0 5
0
a 4
.0 3
0
Cd) 2
.0

0
0. 0 1 2 3 4 5 6 7
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E
—19 —20 —13 —9 —4 —7 —16 —24 —16 —19 —11 —8 —3 —5 —14 —21
8
—17 —20 —12 —8 —6 —5 —12 —17 —15 —19 —10 —7 —5 —4 —11 —15

16
—11
—11
—16
—15
—7
—7
—5
—6
—7
—8
—9
—9
—14
—13
—19
—16
16
—10
—9
—16
—15
—5
—4
—5
—5
—7
—8
—9
—8
—14
—13
—18
—15
C
8 —8 —7 —8 —10 —12 —16 —19 —6 —7 —5 —7 —9 —11 —14 —17
24 40 24 40
—8 —8 —6 —9 —10 —12 —16 —19 — —5 —8 —4 —8 —10 —11 —15 —18

SK11711 04/03/99
JM AEROFOIL
Fan Code: 56J Mu 6/8/5/... woo AIR MOVEMENT

560 mm 670 rev/mm 5 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown sfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do notincludethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000
mm in
I wg wg
/hr
3
m 0 2000 4000 6000 8000
7,

• 0.25
6

-0.20

OCS0a
0
a
4.
13 • 0.15
CS
0
I—
C
(15
3-
w
• 0.10
0.

0.05
1-

nm
ftio,nmInr
EUD COAThOL
flnrnCffihiCA
TflTERflFnTIOflnI. InC.
0- 0.00

0.14
(.2 0.12 E::::::::::::E:.—.— A

,f)
p
0.C0
0CC
U .U*

0.02
-=
-

8
I —
( (V

0.0 0.5 1.0 1.5 2.0 2.5


q, — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 8k Angle 2k 4k
—12 —10 —3 —7 —12 —20 —29 —37 —10 —10 —3 —7 —12 —20 —28 —35
8 8
—7 —11 —7 —5 —8 —13 —20 —24 —6 —11 —7 —5 —8 —12 —19 —23
—11 —12 —3 —7 —12 —19 —28 —34 —10 —12 —3 —7 —12 —19 —27 —33
16 16
—3 —8 —7 —10 —13 —16 —20 —23 —3 —8 —7 —10 —13 —15 —19 —21
—9 —7 —10 —12 —16 —20 —23 —2 —8 —7 —10 —12 —15 —19 —22
24 40 24 40
—3 —8 —8 —11 —14 —18 —23 —28 — —2 —8 —8 —11 —14 —18 —22 —26

SK11713 04/03/99
JM AEROFOIL
Fan Code: 56JM/1 6/6/5/... WOODS AIR MOVEMENT i’
(
560 mm 900 rev/mm 5 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000
rnrii n
wg wg
/hr
3
m 0 2000 4000 6000 5000 10000
12

(9

a)
8
0.3 C
D
(I)
‘9
a)

(9 6-
0
F

(0 0.2
U

0
4

0.1
2

/
Inovcmcnr
AflD OOflrOL
flflOC(TIOfl
IflTERflflhPOflfl(, Inc.
0 0 0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0
0.35

0
a) 0.30
0.25
_40_ C
-o 0.20
a) 0.15
-o
0
a)
0.10
.0
0.05 —

0.00
0 0.0 0.5 1.0 1.5 2.0 2.5 3.0
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle E • E
—12 —11 —3 —5 —10 —18 —26 —33 —10 —11 —3 —5 —10 —18 —25 —31
8 8
—8 —11 —8 —5 —7 —12 —17 —22 —7 —11 —8 —5 —7 —11 —17 —21
—12 —13 —3 —6 —10 —17 —25 —32 —11 —13 —3 —5 —10 —17 —24 —30
16 16
—4 —8 —7 —10 —12 —15 —18 —21 —3 —8 —7 —10 —12 —14 —18 —20
—9 —7 —10 —12 —15 —18 —21 —9 —7 —10 —12 —15 —17 —20
24 40 24 40
—3 —8 —8 —10 —14 —17 —21 —26 — —2 —8 —8 —10 —14 —17 —20 —24

SK11714 04/03/99
JM AEROFOIL
woois’
c © Fan Code: 56JM/20/6/3/...
560 mm 900 rev/mm 3 Blades 50 Hz
Iso 9001
AIR MOVEMENT

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do notincludethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000
. I I I mm in
I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000

0.35

8-
- 0.30

• 0.25
CO
0 6
6)
U)
U)
6) 0.20

CO
0
F
4
CO 0.15

0_i 0

2-

• 0.05

0 0 -0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0

1’- 0.20 - —

- —

0.15
0
cL — —-—----‘--—----. E’ 32°
0
6)
0.10
.0
0
U) 0.05 -

.0

0.00
0 0.0 0.5 1.0 1.5 2.0 2.5 3.0
q — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle —E E EE 7E E
16 —11 —5 —3 —11 —20 —29 —40 —14 —10 —5 —3 —11 —19 —28 —38
8 8
—6 —7 —7 —7 —11 —14 —17 —21 —3 —7 —7 —7 —11 —13 —16 —19
—6 —5 —5 —10 —15 —18 —22 —28 —5 —5 —10 —15 —17 —22 —27
16 16
—4 —6 —7 —10 —15 —18 —22 —27 —2 —6 —7 —10 —15 —18 —21 —25
5 -6 —8 —9 —13 —16 —20 —25 —3 —5 —8 —8 —12 —15 —18 —23
24 36 24 36
—4 —6 —8 —10 —15 —18 —23 —28 — —1 —6 —8 —10 —15 —18 —22 —26

SKi 1715 04/03/99


JMAEROFOIL
Fan Code: 56JM12016161...
©

560 mm 900 rev/mm 6 Blades 50 Hz


BS575oP

ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000
I I I I I mm in
I- wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000
14

0.5
12

10 0.4
(0
0
a)
C
U)
U)
a) 8
0 0.3
(a
0
I
C 6
u

0.2

0.1
2

0 0.0

0.40

0
0.35
0.30
C
o 0.25
0.20
. Q5
0
ca 0.10
.0
< 0.05
I 0.00
o 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
— Volume Flow (m
!s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 Angle E r EE
—22 —11 —8 —2 —9 —19 —29 —39 —20 —9 —8 —2 —9 —18 —28 —37
8 8
—18 —8 —7 —3 —8 —14 —20 —27 —17 —6 —7 —3 —8 —13 —19 —25
—14 —5 —5 —6 —12 —17 —24 —30 —13 —3 —5 —6 —12 —16 —24 —29
16 16
—11 —4 —6 —7 —12 —15 —19 —24 —9 —2 —6 —7 —12 —15 —19 —23
—6 -6 —7 —10 —12 —15 —18 —22 —4 —7 —9 —12 —14 —17 —20
24 40 24 40
—5 —6 —8 —10 —13 —17 —21 —25 — —3 —3 —8 —10 —13 —16 —20 —25

SKi 1716 04/03/99


JM AEROFOIL
Fan Code: 56JM/1 6/4/5/... WOODSI
560 mm 1420 rev/mm 5 Blades 50 Hz
I AIR MOVEMENT ‘
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000
I I mm in
I I I wg wg
/hr
3
m 0 5000 10000 15000
• 1.2
30 -

1.0
25

20 0.8

I 15

10•

5.
0.6

0.4

0.2

rN
movmir
flflD COflflO(
fiI. mc.”
0- -0.0
0 1 2 3 4 5

-
1.4
8) 1.2
0 1.0
-o
0.8
ci) 0.6
0
0
0.4
0.2
0.0
0 1 2 3 4 5
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle - E -EE E 1k 8k
—17 —12 —10 —3 —7 —12 —20 —28 —16 —10 —10 —3 —7 —12 —20 —26
8 8
—17 —8 —11 —6 —5 —8 —13 —19 —17 —6 —11 —6 —5 —7 —13 —18
—17 —11 —12 —2 —7 —12 —19 —27 —16 —11 —12 —2 —7 —12 —19 —25
16 16
—12 —4 —8 —7 —11 —13 —16 —20 —12 —3 —8 —7 —11 —13 —15 —18
—9 —8 —11 —13 —16 —20 —6 —4 —9 —8 —11 —13 —16 —19
24 40 24 40
—7 —4 —9 —9 —12 —15 —19 —24 — —6 —3 —9 —9 —12 —15 —18 —22

SK11717 04/03/99
JM AEROFOIL “ I
Fan Code: 56JM/20/4/3/... woo AIR MOVEMENT
I
560 mm 1420 rev/mm 3 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000
, I mm In
I I I I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000
25-

20 0.8

ct5
I2
a
C
15 0.6
U,
U)

0
I

a 0.4
LI..

5. -0.2

WID COUTROL
flUOCIRTIOfl
IUTCIIIIATIGU UI.
0 0 -0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
0.8
a
0
0.7
0.6
C
a 0.5
0
a 0.4
.0 0.3
0
U) 0.2
.0
0.1 A0X

0.0
a- 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle ••
Angle E E •E
—16 —14 —9 —3 —s —15 —23 —14 —14 —9 —3 —5 —14 —22 —31
8 8
—6 —10 —7 —8 —8 —13 —15 —19 —3 —10 —7 —7 —8 —12 —13 —16
—8 —11 —17 —19 —25 —8 —11 —16 —18 —24
16
—4 —8 —6 —9 —12 —17 —19 —24
16
—2 —8 —6 —9 —12 —17 —18 —23 C
—5 —8 —7 —9 —10 —15 —18 —23 —3 —8 —7 —9 —9 —14 —16 —20
24 36 24 36
—4 —9 —7 —9 —12 —17 —20 —26 — —1 —8 —7 —9 —12 —17 —19 —24

SK11718 04/03/99
JM AEROFOIL Ml,,

Fan Code: 56JM/20/4/6/... woo AIR MOVEMENT

560 mm 1420 rev/mm 6 Blades 50 Hz


iSO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000
I mm in
wg wg
/hr
3
m 0 5000 10000 15000
1.4

12

25 1.0

I
a 20 0.8
0

0
I—
15 0.6
LL

10 0.4

5 0.2

‘lip
Mominr
1110 COATROL
TIIOCIATIOO
IflTETIflrlTl000I. InC.
0• ‘0.0

1.6

I
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • .
8k Angle •E E EE E 4k 8k
—24 —12 —12 —4 —4 —12 —22 —32 —21 —10 —12 —3 —4 —11 —21 —31
8 8
—21 —10 —9 —6 —4 —11 —16 —22 —19 —8 —8 —6 —4 —10 —14 —21
—17 —6 —7 —5 —9 —14 —19 —26 —16 —4 —7 -5 —8 —13 —19 —26
16 16
—14 —4 —7 —8 —9 —14 —16 —21 —12 —3 —6 —8 —9 —14 —16 —20
—5 —9 —9 —12 —14 —17 —21 s —4 —9 —9 —11 —13 —16 —19
24 40 24 40
—6 —5 —9 —10 —12 —16 —19 —24 — —4 —3 —9 —10 —12 —15 —18 —23

SK11719 04/03/99
JM AEROFOIL
Fan Code: 56JM12012131... woo AIR MOVEMENT
cI
I C-
ISO 9001
560 mm 2910 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000
mm in
wg wg
fhr
3
m 0 5000 10000 15000 20000 25000 30000
ioo.

35

80-
3.0

19
0
a>
60
2.5 (
(1)
U>
ci)
0
a> 2.0
0
b
C
cci
U 40
1.5
0.

1.0

20

0.5
r
vie, em ni
miD conrccoi
flilOCiCTiOci
li:nflnTIonnI. Inc.
0 0.0
0 2 3 4 5 6 7 8 9
7
6 C
I
ci)

0 5
0
•0
4 4zz —
ci) 3
.0
0
T SZZ 2
U)
2
.0 -—- -EEE —
80
0
2 3 4 5 6 7 8 9
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E E E
—23 —16 —14 —10 —4 —5 —16 —23 —20 —14 —13 —9 —3 —4 —14 —21
8
—15 —6 —10 —7 —8 —8 —13 —15 —13 —3 —9 —7 —8 —7 —12 —12
—14 —7 —7 —5 —9 —12 —18 —20 —12 —5 —7 —5 —8 —11 —17 —19
16 16
—11 —4 —9 —7 —9 —12 —18 —20

-
—10 —2 —8 —7 —9 —12 —17 —18
—10 —6 —9 —7 —10 —11 —16 —19 —8 —4 —8 —7 —9 —9 —14 —16
24 —36 24 36
—9 —7 —10 —13 —18 —21 — —6 —1 —9 —7 —10 —12 —17 —19

5K11720 04/03/99
JM AEROFOIL
Fan Code: 56JM12012161...
DS’ AIR MOVEMENT
.

560 mm 2910 rev/mm 6 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000
mm n
I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
160
6

140

.5
120

CO
0
CO 100 4
D
G0
CO

CO 80
0 .3
I

CO

60
0
2

40•

20

2mnr
nAnconmol
00CITIOII
nrEnrnITIonrn. Inc.
0• 0
0 2 4 6 8 10

I
CO
0
0
0
CO
.0
0
0
.0

— Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle •7 • E
—21 —24 —13 —12 —3 —5 —13 —22 —19 —23 —11 —12 —3 —4 —12 —20
8 8
—16 —21 —11 —9 —6 —4 —11 —16 —14 —21 —8 —8 —6 —3 —10 —14
—12 —18 —6 —7 —6 —9 —15 —19 —11 —18 —4 —6 —5 —9 —14 —18
16 16
—9 —15 —5 —7 —9 —9 —15 —16 —8 —14 —3 —6 —8 —9 —14 —16

- —10 —10 —13 —15 —18 —6 —8 —4 —9 —10 —12 —14 —16


24 40 24 40
—7 —7 —6 —10 —11 —14 —17 —20 — —4 —7 —4 —9 —11 —13 —16 —19

SK11721 04/03/99
JM AEROFOIL lI,

Fan Code: 63JM12018131... WOODS


I C. AIRMOVEMENT*’

630 mm 680 rev/mm 3 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ducted inlet, Quoted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000
mm in
I- wg wg
m
/
3 hr 0 2000 4000 6000 8000 10000
7

0.25
6

0.20
CS

5)
(.
D
‘I)
U,
a) 4.
a- -0.15
CS
0
I
C 3,
(0
U

- 0.10

• 0.05

UA000hTROI
nHocInTIon
IflTCRflflTIOflfl(. Inc.

0 0.00

0.18
C
-

0.16
0.14
0.12
.
0.10
0.08
0.06
- 0.04
< 0.02
I 0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0
q, — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall levelUse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E E

E
8
—11 —5 —4 —8 —14 —21 —27 —36
8
s —4 —8 —14 —20 —26 —34
—7 —5 —7 —9 —10 —14 —21 —30 —5 —5 —7 —8 —10 —13 —20 —28
—10 —4 —5 —10 —14 —21 —28 —35 —8 —4 —5 —10 —14 —21 —26 —33
16 16
—3 —5 —11 —13 —13 —17 —23 —30 —2 —5 —11 —13 —13 —17 —22 —28
—4 —5 —10 —12 —14 —17 —21 —26 —2 —5 —10 —12 —14 —17 —20 —24
24 36 24
—3 —5 —11 —14 —16 —20 —24 —28 — —2 —5 —11 —14 —16 —20 —22 —26

SK11722 04/03/99
JM AEROFOIL
Fan Code: 63JM/20/8/6/...
woo cI
I AIR MOVEMENT

630 mm 680 rev/mm 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000
mm in
I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000
040
10

• 0.35

8
0.30

C • 0.25
6

j 2
0.20

‘0.15

0.10

0.05

mciv
nib COATRO”%...
flflOCIATIOA
IAycnflnTcOnibI. Inc.
0 0 0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

1 ‘.
0.30
0.25
0 0.20
-o
ci)
0.15
0 0.10
ci,
-Q 0.05
0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
q — Volume Flow (m’/s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall leveLUse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels
Octave Band Centre Frequency (Hz) Pitch
I Outlet Levels
Octave Band Centre Frequency (Hz)
Pitch
5Qi)5Mgle

16

SK11723 04/03/99
JM AEROFOIL ‘ I

Fan Code: 63JM/20/6/3/... woo I cI

C AIR MOVEMENT

630 mm 900 rev/mm 3 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 1000 2000 3000 4000 5000 6000 7000 8000
I I I I I I mm in
I I I I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000

14

0.5
12

10 • 0.4
a
a
C
(0
(0
a) 8
0 0.3
a
0
F
C 6
a
U

0
- 0.2

4,

0.1
2’

noytmIn,
flflD COATROL
flTIOGIATIOA
_j_TIflflflTIOflflI, Inc.
0- -0.0

0.40
a)
0
0.35
0.30
C
0.25
ci) 0.20
.0 0.15
0
(0 0.10
.0
0.05
0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle ••
Angle E E E E •7
—4 —7 —13 —20 —26 —33 —6 —7 —4 —7 —13 —19 —25 —30
8 8
—4 —8 —8 —9 —12 —15 —20 —29 —2 —8 —8 —9 —12 —14 —20 —27

16
—7
—1
—6
—8
—4
—12
—10
—16
—14
—16
—20
—20
—27
—24
—33
—30
16
—5
—1
—6
—8
—4
—12
—10
—16
—14
—16
—20
—19
—25
—23
—30
—28 (
—2 —7 —11 —14 —15 —19 —22 —26 —1 —7 —11 —14 —15 —19 —21 —24
24 36 24 36
—1 —8 —13 —16 —19 —22 —25 —29 — 0 —8 —13 —16 —19 —22 —24 —27

SK11724 04/03/99
JM AEROFOIL I’cI
c Fan Code: 63JM12016161... AIR MOVEMENT

630 mm 900 rev/mm 6 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000
mm in
I I I I I I I I ‘ wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000

• 0.7

15- 0.6

• 0.5

na 0
a
D

6) 04
0..
a
0
I—
C
a - 0.3
LL

a.

5- -0.2

- 0.1

0- 0.0

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k 4k Angle E E •E E 8k

9 8 - -6 —12 —18 —24 —32 —7 —4 —7 —12 —18 —23 —30


8 8
—12 —9 —6 —4 —9 —15 —21 —30 —12 —8 —6 —4 —9 —14 —21 —28
—11 —7 —5 —7 —10 —16 —23 —30 —10 —7 —5 —7 —10 —16 —22 —28
16 16
—8 —4 —7 —9 —11 —14 —19 —26 —7 —4 —7 —9 —11 —14 —18 —24

—6 —4 —6 —11 —14 —18 —21 —25 —6 —11 —14 —18 —21 —24
24 36 24 36
—4 —4 —9 —12 —16 —19 —24 —28 — —4 —4 —9 —12 —16 —19 —23 —26

SK11725 04/03/99
JM AEROFOIL
Fan Code: 63JM12516191... AIR MOVEMENT
C
630 mm 935 rev/mm 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000
mm in
I I I P I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000
-

25-

20 -0.8

a
0.6
C
:3
If)
15
1/)
a

a
0
I—
C
a
U 10- 0.4

0.

5 -0.2

IflOCOflIROL
ngoCIATIon I
onn I-Inc.

0’ -0.0

0.9
a)
0.8
0.7
(
a 0.6
0
0 0.5
a 0.4
0 0.3
0
.0 0.2
0.1
0.0
0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
q, — Volume Flow (m
ls)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specificalTy under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •
4k Angle EE 7E E
—10 —9 —6 —5 —8 —15 —24 —31 —8 —7 —6 —5 —8 —14 —24 —30
8 8
—10 —8 —8 —6 —8 —8 —15 —17 —9 —6 —8 —7 —8 —8 —14 —15

16
—11
—8

—7
—7
—4

—4
—5
—8

—6
—6
—11

—12
—9
—11

—13
—15
—11

—16
—21
—17

—20
—26
—17

—23
16
—9
—7
—6
—2

—3
—5
—8
—6
—11
—9
—11
—15
—11
—21
—16
—25
—16 C
24 —6 —12 —13 —15 —19 —22
40 24 40
—5 —5 —7 —13 —14 —17 —23 —26 — —3 —3 —7 —13 —14 —17 —22 —25

5K11728 04/03/99
JM AEROFOIL
Fan Code: 63JM/20/4/3/... AIR MOVEMENT

630 mm 1420 rev/mm 3 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft

/hr
3
m
0
F
0
2000

5000
4000 6000

10000
8000
I-
15000
10000 12000

20000
I — mm
wg
in
wg

1.2
30-

1.0
25

a 20 -
0.8
0
a
:3
a
a
6)
3-
a 15 0.6
a
I—

a
U

10 0.4

5 0.2

/
CCD COflTROI
nr,oGITIo
IATERCATIOARI. Inc.
0• -0.0

q — Volume Flow (m
!s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -
soo E -
Angle
—7 —13 —6 —5 —10 —15 —22 —29 —5 —12 —6 —5 —10 —14 —21 —26
8 8
—2 —12 —9 —10 —13 —14 —19 —25 —1 —11 —9 —10 —13 —13 —18 —23
—5 —12 —5 —7 —13 —16 —24 —30 —4 —12 —5 —7 —12 —15 —22 —27
16 16
—1 —10 —11 —17 —20 —19 —23 —29 0 —10 —11 —17 —19 —19 —22 —27
—2 —9 —9 —15 —16 —19 —22 —26 —1 —9 —9 —15 —16 —18 —20 —24
24 36 24 36
—1 —9 —11 —17 —19 —22 —26 —29 — 0 —9 —11 —17 —19 —21 —24 —27

5K11729 04/03/99
JMAEROFQIL
Fan Code: 63JM12014161... c
630 mm 1420 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
mm In
I I I wg
I I wg
/hr
3
m 0 5000 10000 15000 20000
450

400
40-
-1.5
350

(0

ci)
300
30 -
D
0
250 -1.0

(0
0
H 200
C
20
(0
U

0. 150

0.5
100 10

0-0.0

9)
0
(.
0
0
9)
-e0
(I)

0.0
0

— Volume Flow 3
(m
! s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freouency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E Angle E EE -E E E
—12 —8 —7 —4 —9 —13 —21 —27 —11 —7 —7 —4 —9 —13 —20 —25
8 8
—15 —10 —8 —5 —6 —10 —17 —24 —15 —10 —8 —5 —6 —9 —17 —23
—14 —8 —6 —5 —9 —11 —19 —25 —13 —8 —6 —5 —9 —11 —18 —24
16 16
—11 —5 —6 —8 —11 —12 —16 —22 —11 —5 —6 —8 —11 —11 —15 —20
—8 —4 —6 —9 —13 —15 —19 23 —7 —4 —6 —9 —13 —15 —18 —22
24 36 24 36
—6 —4 —7 —11 —14 —17 —21 —26 — —6 —3 —7 —11 —14 —17 —20 —24

SK11730 04/03/99
JM AEROFOIL
Fan Code: 63JM12514161... woocII
AIR MOVEMENT

ISO 9001
630 mm 1440 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
mm in
wg wg
/hr
3
m 0 5000 10000 15000 20000
-1.6
40

-1.4

1.2

IN 0
1) 25
0
ci)
0
cci 20- 0.8
0
I
C
cci
LI
is. 06
0.

10- 0.4

5- 0.2

0- 0.0

0 1 2 3 4 5 6 7
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 8k Angle E - E •E 4k
—11 —11 —8 —4 —6 —12 —19 —28 —9 —7 —4 —6 —12 —19 —26
8 8
—6 —7 —8 —9 —10 —10 —12 —16 —5 —6 —7 —9 —11 —10 —11 —14
—7 —5 —9 —11 —11 —17 —21 —6 —6 —5 —9 —10 —11 —16 —21
16 16
—5 —6 —7 —11 —13 —14 —16 —21 —3 —5 —6 —11 —13 —14 —16 —20
—4 —7 —6 —9 —13 —15 —20 —25 6 —6 —9 —13 —14 —19 —23
24 24 32
—4 —6 —8 —12 —15 —17 —22 —27 — —1 —4 —7 —12 —15 —17 —21 —26

SK11732 04/03/99
JM AEROFOIL
Fan Code: 63JM12514191... woo AIR MOVEMENT
I
630 mm 1440 rev/mm 9 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14900
mm in
T wg wg
/hr
3
m 0 5000 10000 15000 20000
2.0
50

40
1.5

(U
0
U)
(
U)
30
Cr,
U)

(U •1.0
0
I—
C
(U
LL 20
0.

• 0.5

10

0• •0.0
0 1 2 3 4 5 6 7
3.5
U) 3.0 (..
0 2.5
-o
2.0
U) 1.5
.0
0 1.0
U)
.0
0.5
0.0
0 0 2 3 4 5 6
q — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 4k Angle E E E E
—13 —10 —9 —6 —5 —10 —18 —27 —9 —7 —6 —4 —10 —17 —25
8 8
—13 —10 —8 —7 —7 —8 —10 —16 —12 —10 —6 —7 —7 —7 —9 —14
—12 —11 —7 —4 —8 —11 —17 —23 h1 —10 —5 —4 —8 —10 —17 —22
16 16
—9 —9 —5 —8 —11 —11 —12 —17 —7 —8 —3 —8 —11 —11 —12 —16
—6 —8 —5 —9 —13 —14 —19 —22 —7 —4 —9 —13 —14 —17 —21
24 40 24 40
—4 —7 —6 —10 —15 —16 —21 —26 — —2 —6 —4 —10 —15 —16 —20 —25

5K11733 04/03/99
JM AEROFOIL
Fan Code: 63JM12512131... WOODS AIR MOVEMENT

630 mm 2910 rev/mm 3 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000 35000 40000
120

100-

(_•‘ 80 -

LI) -3

0)
Li)

is 60’
0
I—

is -2
Ll

a
40

20

nnocoliTIio -

OClTIO
IATERflATIOOIII. rnc
0- -0

Cl

0 2 4 6 8 10 12
q — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - Angle —

—23 —12 —13 —8 —4 —8 —14 —21 —20 —9 —11 —8 —3 —7 —13 —18


8 8
—16 —4 —7 —8 —11 —14 —15 —15 —15 —1 —5 —7 —11 —13 —13 —12
—16 —6 —6 —6 —7 —12 —17 —20 —15 —5 —6 —6 —7 —12 —16 —19
16 16
—12 —4 —6 —8 —12 —16 —18 —20 —11 —1 —5 —8 —12 —16 —17 —19
—6 —5 —7 —9 —14 —17 —20 —23 —4 —3 —6 —9 —13 —16 —18 —20
24 32 24—32
—7 —4 —6 —10 —15 - —18 —21 —24 —5 —2 —5 —10 —15 —17 —19 —22

SK11734 04/03/99
JM AEROFOIL
Fan Code: 63JM/25/2/6/... AIR MOVEMENT

ISO 9001
630 mm 2910 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
wg wg
/hr
3
m 0 10000 20000 30000 40000
160-
6

140-

‘5
120

(0

ci) 100
C
D
U)
U)
a)
0
a 80
0 3

Co
LI
60
0.
2

40-

20-

rnovcmcn”%,.
flflfl COATIcOL
flT5OCITIOT
ITTCTTTTIOflTI, Inc.
0- -0

18
16
(.
0
8)
0

a
.0
14
12

10
8
I
- --- -
+—__ — —

0 6
U) 4
.0
2
0
0 2 4 6 8 10 12 14
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freouency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle •• •• •

—20 —11 —11 —8 —5 —7 —13 —20 —17 —11 —10 —6 —4 —6 —12 —18
8 8
—16 —6 —7 —8 —9 —11 —11 —12 —15 —6 —6 —7 —9 —10 —9 —10
—10 —7 —8 —5 —10 —11 —12 —17 —7 —5 —9 —11 —12 —16
16 16
—11 —5 —6 —7 —12 —13 —14 —17 —10 —5 —5 —6 —12 —13 —14 —16
—6 —6 —8 —8 —11 —14 —17 —21 —4 —5 —8 —7 —11 —13 —15 —20
24 36 24 36
—7 —5 —7 —9 —13 —16 —18 —23 — —4 —4 —6 —8 —13 —16 —17 —22

SK11735 04/03/99
JM AEROFOIL
Fan Code: 63JM/25/2/9/...
WOODS
I AIR MOVEMENT

630 mm 2910 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
I wg wg
/hr
3
m 0 10000 20000 30000 40000
8
200-

150 6

(0
0
5
0
0
a)
ci
1000 100
0
I—
C
Cs
Li
.3
0

50. -2

-1

yT
(RD CORTROL.
flHOCIRflOjI
IflT(RRRTIOFIRI. Inc.
0• -0
0 2 4 6 8 10 12 14

C)

0 2 4 6 8 10 12 14
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 7 4k 8k

—16 —14 —10 —9 —6 —5 —11 —18 14 —13 —10 —7 —6 —4 —10 —16


8 8
—15 —13 —11 —8 —7 —7 —8 —11 —13 —13 —10 —6 —7 —6 —7 —9
—14 —13 —11 —7 —4 —8 —12 —17 —12 —13 —11 —5 —4 —8 —11 —17
16 16
—9 —9 —9 —5 —9 —11 —12 —13 —8 —9 —9 —3 —9 —11 —12 —12
—7 —9 —6 —10 —14 —16 —20 —6 —6 —8 —4 —10 —13 —14 —18
24 40 24 40
—6 —6 —9 —8 —12 —16 —18 —22 — —4 —5 —8 —6 —12 —16 —17 —21

SK11736 04/03/99
JM AEROFOIL
Fan Code: 71 J M/20/8/3/... woo CI
I C AIR MOVEMENT

710 mm 680 rev/mm 3 Blades 50 Hz


iSO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD — Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft

/hr
3
m
0

I
0
-
1000
I

2000
I
2000
I
I
4000
3000
I

6000
4000
I
I
8000
5000
I
6000
I
10000
I
7000

12000
I
8000
mm
wg
in
wg

0.35

8-
0.30

0.25
(0

a)
D
6
C
I)
a,
a 020
0.
(0
0
b 4
C
(0 0.15
U

0.10

2-

0.05

INno, emcnr”%.
Ann COnTROL
T000IRTIOA ‘I
Inc.
0 0 •0.00
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
0.30
a
0
0.25
0.20
-_-


— -
C
a
a
.0
0.15 -
- 24
-

0
a)
.0
0.10
0.05
— —
D—
0
16°

0.00
0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 8k Angle E E E 7E E
—13 —7 —3 —8 —12 —19 —25 —35 —11 —6 —3 —8 —12 —19 —24 —32
8 8
-

—8 —7 —6 —7 —9 —14 —20 —29 —7 —6 —6 —7 —9 —13 —19 —27


—11 —17 —22 —29 —8 —5 —5 —11 —17 —20
16 —9 —27
(-
-

16
—4 —5 —9 —12 —12 —15 —20 —26 —3 —5 —9 —12 —12 —15 —18 —24
—5 —6 —9 —10 —10 —14 —18 —25 —3 —6 —9 —10 —10 —14 —17 —23
24 36 24 36
—3 —5 —10 —12 —13 —17 —20 —27 — —2 —5 —10 —12 —13 —16 —19 —24

SK11737 04/03/99
JM AEROFOIL
Fan Code: 71JM12018161... woo AIR MOVEMENT

710 mm 680 rev/mm 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000
I I I I I I mm in
I I wg wg
/hr
3
m 0 5000 10000 15000
14

0.5
12

04

Oj
8
- 0.3

- 0.2

4.

0_i
2

flIDCOflTAOL
flI5OGITIOfl
IflTIRflATiQAI. Inc.
0• •0.0
0 1 2 3 4 5
0.45
C) 0.40
0.35
0.30
-

0.25 !E__
0.20
0.15
0.10 -
-

-18
0.05
0.00
0 1 2 3 4 5
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 •7 Angle EEE E TE E E
—11 —7 —4 —7 —11 —18 —25 —34 —9 —7 —4 —7 —11 —18 —24 —32
8
—12 —9 —5 —5 —8 —16 —22 —32 —12 —9 —5 —5 —8 —14 —22 —31
—11 —6 —4 —8 —11 —18 —24 —10 —6 —4 —8 —11 —18 —24 —32
16 16
—6 —6 —7 —9 —10 —14 —19 —27 —6 —6 —7 —9 —10 —14 —19 —25
—5 —6 —7 —10 —11 —15 —19 —26 —4 —6 —7 —10 —11 —15 —18 —24
24 36 24 36
—4 —5 —8 —12 —13 —17 —21 —28 — —3 —5 —8 —12 —13 —17 —20 —26

5K11738 04/03/99
JM AEROFOIL I
H

Fan Code: 71 JM/25/8/61...


woo AIR MOVEMENT
I C
710 mm 695 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000
I I I mm in
I I I I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000
120
12 -

100 04
10-

8
ci) 0.3
U)
U)
9)

CO 6
0
F

Cd 0.2
U-

0.
4

0.1
2

OCR
900IR1E flT
0110 COCC0110C
A 1150 11 151 CO
CflTEflhlATIOAnC. Inc.

0 0.0

0
C
0

.0
0
Cl)
.0

ci 4.5
q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall leveLUse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 4k 8k
—13 —9 —4 —5 —12 —18 —26 —11 —8 —4 —5 —12 —17 —25 —33
8 8
—9 —8 —7 —6 —8 —10 —18 —26 —7 —8 —7 —6 —8 —10 —17 —24
—9 -6 —7 —6 —10 —14 —21 —27 —7 —6 —9 —14 —21 —27
16 16
—6 —5 —8 —10 —12 —14 —20 —26 —4 —4 —8 —10 —12 —14 —20 —25
—6 —6 —7 —8 —12 —16 —19 —23 —5 —7 —8 —11 —15 —17 —21
24 36 24 36
—5 —6 —7 —10 —13 —16 —21 —25 — —2 —5 —7 —10 —13 —16 —20 —24

5K11740 04/03/99
JMAEROFOIL
Fan Code: 71 JM12518191... WOODS AIR MOVEMENT

710 mm 695 revlmin 9 Blades 50 Hz


BS575OPt1
EN 29001
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 -

I I mm in
I I I I I I I I I wg wg
/hr
3
m 0 2000 4000 6000 8000 10000 12000 14000
14

- 0.5
12

o. 04

8-
0.3

60 6-

- 0.2

4-

- 0.1
2
r

0 0.0

0I
0.6
0.5 -_

0.4
-
0.3
0.2 -
- e
4
—=
0.1 10

0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
— Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle •E E
—10 —9 —6 —4 —10 —17 —26 —34 —8 —7 —6 —4 —10 —16 —25 —33
8 8
—10 —8 —7 —6 —8 —10 —20 —27 —9 —6 —7 —6 —8 —9 —19 —26
—10 —7 —4 —7 —11 —16 —23 —30 —9 —6 —4 —7 —11 —16 —23 —29
16 16
—9 —5 —6 —8 —10 —12 —20 —27 —7 —3 —6 —8 —10 —12 —20 —26
—8 —5 —6 —8 —11 —14 —18 —22 —6 —4 —6 —8 —11 —13 —17 —20
24 36 24 36
—7 —5 —6 —9 —12 —15 —21 —25 — —5 —3 —6 —9 —12 —15 —20 —24

SKi 1741 04/03/99


JM AEROFOIL
Fan Code: 71JM/20/6/3/... AIR MOVEMENT
I (--
710 mm 900 rev/mm 3 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 -

I I mm in
I I wg wg
/hr
3
m 0 5000 10000 15000 20000
16 -

0.6

14

0.5
12

a
-: 10 0.4
U)
U)
ci)
0

I 6

0.1
2
rx
nfl
Tb, cm c fly
IbID COflIOt
FITTOCffiTIOD
IRTEflflflhbOflflT Inc.
0- •0.0

0.7 —

0
a 0.6
0.5 -
- -
C
0 —_- 32°
0.4
a
.0 0.3
0 0.2
U)
.0
0.1
0.0
0 U 2 3 4 5 6
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freouency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle —
4k 8k
—12 —9 —3 —6 —11 —18 —23 —31 —10 —8 —3 —6 —11 —17 —22 —28
8 8
—6 —8 —7 —7 —9 —14 —19 —27 —4 —8 —7 —7 —9 —12 —18 —25
—7 —5 —8 —11 —16 —20 —27 —7 —5 —8 —11 —16 —19 —24
16 16
—2 —7 —10 —14 —13 —17 —20 —26 —2 —7 —10 —14 —13 —16 —19 —24
—7 —9 —11 —10 —14 —17 —23 —2 —7 —9 —11 —10 —14 —16 —21
24 36 24 36
—2 —7 —11 —13 —14 —18 —21 —26 — —1 —7 —11 —13 —14 —17 —19 —24

5K11742 04/03/99
JM AEROFOIL
Fan Code: 71 J M12016161... ,
t
woo, cI
AIR MOVEMENT

710 mm 900 rev/mm 6 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
mm in
I wg wg
/hr
3
m 0 5000 10000 15000 20000
-1.0
25-

20 0.8

(N..
150 0.6
15

100 10- 0.4

5. -02

0- •0.0

1.2

UI 1.0
0.8
0.6
0.4
0.2
0.0
0 1 2 3 4 5 6 7
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle -
E
—8 —4 —6 —10 —17 —23 —31 —7 —4 —6 —10 —17 —22 —28
8 8
—14 —9 —6 —4 —7 —14 —20 —28 —14 —9 —6 —4 —7 —13 —20 —27
—13 —7 —4 —7 —10 —16 —23 —30 —12 —7 —4 —7 —10 —16 —22 —28
16 16
—8 —5 —6 —9 —10 —13 —18 —24 —8 —5 —6 —9 —10 —13 —17 —22
—5 —6 —10 —11 —14 —18 —23 —6 —5 —6 —10 —11 —14 —17 —22
24 36 24—36
—5 —4 —8 —11 —13 —17 —20 —25 —4 —4 —8 —11 —13 —17 —19 —24

SK11743 04/03/99
JM AEROFOIL
Fan Code: 71 J M12516161...
woo MR MOVEMENT
C
ISO 9001
710 mm 935 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000
mm in
I I wg wg
ihr
3
m 0 5000 10000 15000 20000
200 • 0.8
20

• 0.7

150 0.6
15

(‘3
0
ci)
05 (
cc)
cc,
a)
0
(‘3
100 10 -
• 0.4
0
I—
C
cci
IL
• 0.3
0

50 5 0.2

0.1

fin,, conn,o,’%.
nnnocrnnon
IfltEflflflTIOflftI. Iflo•
0 0.0
0 1 2 3 4 5 6
1.0
ci) 0.8
0
0.6
V
ci)
.0 0.4
0
cc,
.0 0.2
0.0
0 1 2 3 4 5 6
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 2k

—12 —10 —5 —4 -.-1O —16 —24 —31 —10 —9 —5 —4 —10 —16 —24 —29
8 8
—7 —9 —8 —7 —8 —10 —17 —24 —5 —7 —8 —7 —8 —9 —16 —22
—7 —6 —7 —7 —9 —14 —20 —25 —6 —5 —7 —7 —13 —20
16
—4 —6

—6
—9

—7
—11

—9
—13

—12
—14

—15
—20

—19
—25

—21
16
—2 —4 —9

—7
—11

—9
—9
—13

—11
—14

—14
—20

—18
—24
—24

—19
C
24 36 24—36
—4 —7 —8 —11 —13 —16 —21 —24 —1 —5 —8 —11 —13 —16 —20 —23

SK11745 04/03/99
JM AEROFOIL I
Fan Code: 71JM/25/6/9/... wool”
710 mm 935 rev/mm 9 Blades 50 Hz
H AIR MOVEMENT
I

Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000
I I I mm in
F I
I
I wg wg
!hr
3
m 0 5000 10000 15000 20000
1.0
25 -

20 0.8

CO
cC..
0)
15 0.6
0
C/C
cC)
0
CO
0
I—
C
CO
U- i. -0.4
a.

5-0.2

00 COnTOOL
TCOCIOTIOII
ITTTTPILTIOOI. Inc.
0- -0.0

1.4
Oj 1.2
1.0
0.8
0.6
0.4
0.2
0.0
0 1 2 3 4 5 6
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 •7 Angle E s 1k 2k 4k 8k
—11 —9 —6 —5 —8 —15 —24 —30 —8 —7 —6 —5 —8 —14 —24 —29
8 8
—10 —8 —8 —6 —8 —8 —18 —24 —9 —6 —7 —6 —8 —8 —16 —23
—10 —8 —5 —6 —9 —15 —21 —27 —7 —5 —6 —9 —15 —21 —26
16 16
—9 —5 —6 —9 —10 —12 —18 —24 —7 —3 —6 —9 —10 —12 —18 —24
—8 —6 —6 —8 —11 —14 —18 —20 —6 —4 —6 —8 —10 —13 —16 —18
24 36 24—36
—7 —5 —6 —10 —12 —15 —20 —23 —4 —3 —6 —10 —12 —15 —19 —22

5K11746 04/03/99
JMAEROFOIL
Fan Code: 71 JM/20/4/3/...
4
WOODS AIR MOVEMENT

EN29001
Iso 9001
I I mm 1440 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

!min
3
ft 0 5000 10000 15000
I I I mm in
I I I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
400 -1.6
40-

350

300 12
30-

a
6)
D
250
25- C
0
0
6)
0
<II
200 20- 08
0
I

a
LL
150 15- 06

100 10 0.4

5 0.2

lAD 000YROL
nr,00rnrloA
IlITAlIflATlOAflI. Inc.
0 0.0
0 1 2 3 4 5 6 7 8 9
I]
. ‘

T -T-------
a
0
2.E
2.C
C.
-_

a) 1.5
240
-_—

.0 — .____

0 Ii
0)
.0 0.5 —z= +__

.1.

0.0
0 1 2 3 4 5 6 7 8 9
q, — Volume Flow (m
!s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• 1k Angle •

E -E E -E •- -E
—11 —15 —7 —4 —9 —13 —21 —27 —8 —13 —6 —3 —9 —12 —19 —23
8 8
—5 —12 —9 —9 —10 —12 —17 —23 —3 —11 —8 —8 —9 —10 —15 —20

16
—6
—2
—11
—9
—6
—9
—7
—14
—12
—16
—13
—16
—19
—20
—24
—24
16
—1
—11
—8
—6
—9
—6
—14
—11
—16
—12
—15
—17
—18
—21
—22
(—
—9 —9 —13 —13 —14 —17 —22 —2 —8 —8 —12 —12 —13 —15 —19
24 36 24 36
—2 —8 —10 —14 —16 —17 —21 —25 — —1 —8 —9 —14 —16 —16 —19 —22

SK11 747 04/03/99


JM AEROFOIL I
wooI”
Fan Code: 71 J M12014161... AIR MOVEMENT
I
710 mm 1440 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0
I____
5000
I — —
10000
-- I -__ 15000
-——
20000
I
I
mm
wg
in
wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
60’

-2.0
so.

(0
0 40
0 -1.5

C’,
a’
0

(9 30-
a
I
C
(9 •1.0
L1

0.
20

0.5
10-

(flu GOflTOL
FIfl%OCITIOfl
IflT(flflflTlGflfll. Inc.
0 0- ‘0.0
0 2 4 6 8 10
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0 2 4 6 8 10
— Volume Flow 3
(m
/ s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 2k 8k
—16 —11 —8 —4 —8 —12 —20 —26 —15 —9 —7 —4 —8 —11 —19 —23
8 8
—18 —12 —9 —5 —6 —8 —17 —23 —17 —11 —9 —5 —6 —7 —16 —21
—16 —11 —6 —5 —9 —11 —19 —25 —15 —10 —6 —4 —9 —11 —18 —23
16 16
—11 —6 —6 —8 —10 —11 —15 —20 —11 —5 —6 —7 —10 —10 —14 —18
—10 —6 —7 —8 —12 —12 —16 —20 —8 —5 —7 —7 —11 —12 —15 —19
24 36 24 36
—8 —5 —7 —10 —13 —14 —19 —23 — —7 —4 —6 —9 —13 —14 —17 —21

SK11748 04/03/99
JMAEROFOIL I
I WOODS
4
Fan Code: 71 J M/25/4/3/... AIR MOVEMENT
(
i u mm 1440 rev/rn in 3 Blades 50 Hz
BS575OPt1

ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000 16000
I I I I I I mm in
I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000
1.4

1.2
30

25 1.0

a
0
a)
D
(.
Ga
</) 20 -0.8
ci)
0
a
0
H

a 15 -0.6
LI

10 -0.4

5-0.2

flrEnnnTIOflM, Inc.
0 0 -0.0
0 1 2 3 4 5 6 7 8

2.0
a)
0
1.5 —

•—.---.--. :— 320 C
— —

a) 1.0 - -.—-—--.—----
24°
0 —

0.5 16

0.0
0 0 1 2 3 4 5 6 7 8
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Octave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz)
Pitch
Angle -. 1k 4k 8k
Pitch
Angle -E -E -EE E 1k 8k

—12 —14 —9 —4 —7 —14 —20 —28 —9 —12 —9 —3 —6 —13 —19 —25


8 8
—4 —9 —9 —10 —11 —14 —14 —21 —1 —7 —8 —9 —11 —12 —12 —19

—6 —8 —7 —8 —11 —15 —18 —21 —3 —6 —7 —8 —10 —14 —17 —20


16
—3 —7 —9 —11 —14 —17 —18 —24 —1 —6 —9 —11 —14 —16 —17 —22
—4 —6 —9 —11 —13 —16 —19 —22 —2 —5 —8 —10 —12 —15 —17 —19
24 32 24 32
—4 —7 —10 —12 —13 —16 —19 —22 — 0 —5 —10 —11 —13 —15 —18 —20

SK11749 04/03/99
JM AEROFOIL
Fan Code: 71 J M/25/4/6/... WOODS’S
c AIR MOVEMENT

710 mm 1440 rev/rn in 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000
mm in
I I wg wg
m
/
3 hr 0 5000 10000 15000 20000 25000 30000
2.0
50

40
1.5

a
0

300
30

1.0

L 200 20

0.5

10

nftocIahIon
IfltEflflflhIOflflt. Inc.
0 0.0

-J I
Sound Data BS848 Part 2 1985:
q — Volume Flow 3
(m
/ s)

Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle

1k E
—13 —14 —10 —5 —6 —13 —19 —27 —11 —11 —8 —4 —5 —12 —18 —25
8
—8 —11 —10 —8 —8 —9 —12 —20 —7 —9 —8 —8 —7 —8 —10 —18
—8 —11 —7 —8 —8 —12 —17 —23 —6 —9 —6 —8 —7 —10 —16 —21
16 16
—5 —8 —7 —11 —12 —14 —16 —22 —3 —7 —5 —10 —ii —13 —16 —21
—5 —8 —8 —9 —10 —14 —18 —21 —10 —13 —16 —19
24 36 24 32
—4 —7 —8 —10 —12 —15 —19 —23 — —2 —5 —7 —10 —12 —15 —18 —22

SK11750 04/03/99
JM AEROFOIL
Fan Code: 71JM12514191... WOODS AIR MOVEMENT
(..
710 mm 1440 revlmin 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000
mm in
I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
60

-2.0
50-

a 40
0
a)
D
1.5 C
U,
U)
a)

a 30
0
I—
C
a 1.0
w

a-
20

0.5
10
‘7

0
0 2 4 6 8
rN III)
rnovuhl’nr
flflD COhIRO)
)UOCIATIOR
IflTfFIflflTIOflflt. Inc.

10
0• 0.0

5
a)
a
4 CF
3
a)
2
0
U)

I 0
0 2 4 6 8 10
— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E Angle •E E E E E


—12 —11 —10 —6 —5 —11 —18 —27 —9 —7 —6 —4 —10 —17 —25
8 8
—12 —11 —8 —7 —7 —8 —11 —21 —10 —10 —6 —7 —7 —7 —9 —19
—10 —11 —7 —5 —8 —12 —17 —24 —9 —10 —6 —5 —7 —11 —17 —23
16 16
—8 —10 —6 —7 —9 —12 —14 —22 —6 —9 —4 —g —11 —13 —21
—6 —10 —7 —8 —10 —13 —17 —20 —4 —9 —6 —7 —9 —12 —15 —18
24 36 24—36
—5 —9 —7 —8 —11 —14 —18 —23 —3 —8 —5 —8 —11 —14 —17 —21

SK11 751 04/03/99


JM AEROFOIL -‘1’ I

Fan Code: 71 J M/3 1/2/9/... woo AIR MOVEMENT


I
710 mm 2910 rev/mm 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000 40000 -

I I I I I mm In
‘ wg wg
m
/
3 hr 0 10000 20000 30000 40000 50000 60000
250

200

1500 -6
150

L 1000 4
100-

50- 2

flIDOOflTO
nnocrnyion
lflTEflflflTIOflflL Inc.
0--C

45

I
40
35
30
25
20
15
10
5
0
0 5 10 15 20
q — Volume Flow 3
(m
/ s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 Angle
-
E
—13 —12 —11 —10 —6 —5 —12 —19 —11 —11 —10 —7 —6 —4 —11 —17
8
—13 —12 —11 —9 —7 —7 —8 —11 —11 —11 —10 —7 —7 —6 —7 —9
—11 —11 —12 —8 —6 —8 —13 —19 —9 —10 —11 —6 —5 —7 —12 —17
16 16
—8 —9 —11 —7 —8 —10 —13 —15 —7 —8 —10 —5 —8 —10 —12 —14
—6 —7 —12 —8 —9 —12 —15 —18 —4 —6 —11 —7 —8 —10 —13 —16
24 40 24 40
—6 —7 —11 —8 —9 —13 —16 —19 — —4 —6 —10 —6 —9 —12 —14 —18

SK11752 04/03/99
JM AEROFOIL .\\I 1

Fan Code: 80JM12018131... AIR MOVEMENT


I
800 mm 695 rev/mm 3 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000
I I I I I mm In
I I I wg wg
/hr
3
m 0 5000 10000 15000 20000
0.40

• 0.35

8
• 0.30

(15

a
6
0.25 (
a
0

(15 0.20
0
b
(15
U 4-
0.15
0

0.10

0.05

2mERT
AO COMOL
(JSOOIRYIOfl
IflTIflflATIOflhI(. Inc.
0 P0.00
0 1 2 3 4 5 6

a
0
0

a
.0
0
0
.0

0 0 1 2 3 4 5 6
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 2k Angle E •E E 8k

—17 —8 —3 —7 —10 —18 —23 —32 —8 —3 —7 —10 —17 —22 —29


8 8
—11 —8 —6 —6 —8 —14 —19 —27 —9 —8 —6 —6 —8 —13 —18 —26

16
—5 —5

—7
—5
—9

—9
—9
—11

—8
—9
—11

—6
—12
—13

—11
—15
—16

—16
—22
—22

—23
16
—8
—5

—6
—7
—5

—7
—5
—9

—9
—9
—11

—8
—9
—11

—6
—12
—13

—11
—14
—15

—14
—19
—20

—22
C
24 36 24—36
—5 —6 —9 —10 —9 —13 —17 —25 —4 —6 —9 —10 —9 —13 —16 —22

SK11753 04/03/99
JM AEROFOIL
c Fan Code: 8OJM/20/8/6/... woo cI
AIR MOVEMENT

800 mm 695 rev/mm 6 Blades 50 Hz


sssopti
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
I mm in
F I I
wg wg
/hr
3
m 0 5000 10000 15000 20000
16
0.6

14

0.5
12

0
a) 10
Ca
a
‘3-
a 8
0 0.3
I
C
a
L1
6

0.2

0.1
2

0 0.0

()

q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Singie figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • . 7 Angle •
7
—13 —7 —4 —6 —9 —18 —24 —32 —12 —7 —4 —6 —9 —18 —23 —30
8 8
—14 —10 —6 —5 —6 —16 —21 —29 —13 —10 —6 —5 —6 —14 —20 —28
—14 —6 —3 —8 —11 —19 —24 33 —13 —6 —3 —8 —11 —19 —23 —31
16
—7 —6 —7 —9 —9 —13 —18 —24 —7 —6 —7 —9 —9 —13 —17 —23
—8 —7 —6 —9 —8 —12 —16 —23 —7 —7 —6 —9 —8 —12 —1 B —22
24 36 24 36
—5 —6 —7 —11 —11 —15 —18 —25 — —4 —6 —7 —11 —11 —14 —17 —23

SK11754 04/03/99
JM AEROFOIL
Fan Code: 80JM12518131... WOODS
I AIR MOVEMENT

800 mm 695 rev/mm 3 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

ft’/min 0 2000 4000 6000 8000 10000


I I I I mm in
I I I wg wg
/hr
3
m 0 5000 10000 15000

0.35

8
0.30

0.25
Cs 6
C
0
C,,
ci) • 0.20

(U
0
F—
4
Cs -0.15
U

0.

0.10

• 0.05

flov.mcnr ‘%
(CD COnTROl
T000IRTIOA
,nrnnn,a,mi. Inc.
0 •0.00
0 1 2 3 4 5
0.35
ci)
0
0.30
0.25
C;
IL
-D
0.20
ci)
0.15
0
C,,
0.10
0.05 —

0.00
0 0 1 2 3 4 5
q — Volume Flow (m’/s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall leveLUse
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E E Angle
—15 —10 —3 —5 —13 —18 —24 —34 —13 —10 —3 —6 —13 —18 —24 —31
8 8
—8 —8 —6 —6 —10 —11 —16 —23 —7 —8 —6 —7 —11 —10 —15 —21

16
—6 —7 —7 —7 —11 —13 —16 —22
16
s —7 —7 —8 —11 —13 —15 —20
—5 —7 —7 —9 —12 —14 —17 —23 —4 —7 —7 —9 —13 —13 —16 —21
—7 —8 —8 —12 —15 —19 —24 —4 —7 —8 —9 —12 —15 —17 —23
24 32 24—32
—5 —8 —7 —7 —10 —13 —17 —22 —5 —8 —7 —8 —11 —13 —15 —19

SK11755 04/03/99
JM AEROFOIL
Fan Code: 8OJM/25/8/6/... WOODS “
I
I AIR MOVEMENT

ISO 9001
800 mm 695 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000 -

I I I I mm In
I wg wg
/hr
3
m 0 5000 10000 15000 20000
14

- 0.5
12

10 0.4

8
0.3

6-

0.2

0.1
2

0 0• -0.0
0 2 3 4 5 6 7

/‘
0.7
0.6
0.5
t3
0.4
a 0.3
0
0
0.2
0.1
0.0
0 1 2 3 4 5 6 7
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E r
—16 —11 —4 —3 —12 —18 —25 —34 —14 —11 —4 —4 —13 —18 —24 —32
8 8
—14 —11 —7 —4 —7 —12 —18 —27 —14 —11 —7 —5 —8 —11 —18 —26
—12 —8 —7 —4 —10 —15 —21 —29 —11 —8 —7 —4 —11 —15 —21 —28
16 16
—8 —4 —8 —8 —11 —14 —18 —24 —8 —4 —8 —9 —11 —13 —17 —23
—7 —7 —6 —11 —14 —17 —23 —7 —7 —11 —14 —17 —22
24 36 24
—7 —7 —7 —7 —11 —14 —18 —23 — —6 —7 —7 —7 —12 —14 —17 —22

5K11756 04/03/99
JM AEROFOIL :lI I

Fan Code: 8OJM/25/8/9/... woo AIR MOVEMENT


I C
800 mm 695 rev/mm 9 Blades 50 Hz
SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000
mm in
T wg wg
/hr
3
m 0 5000 10000 15000 20000

0.7

15 0.6

0.5
a
0
9) C
C,)
C,)
a 10 0.4
0
a
0
I—

a 0.3
LL.

5 • 0.2

0.1

0 •0.0
0 1 2 3 4 5 6 7
1.0

0
a 0.8 C
0 0.6
a
.0 0.4
0
C,)
.0 0.2
0.0
0 0 2 3 4 5 6 7
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E 7 ••
Angle E EE E
—10 —9 —6 —4 —10 —17 —26 —34 —7 —6 —5 —10 —17 —25 —32
8 8
—10 —8 —7 —6 —8 —10 —20 —27 —10 —7 —7 —8 —8 —8 —19 —26

—10 —6 —5 —6 —12 —17 —22 —30 —9 —6 —5 —7 —12 —17 —21 —28


16 16
—11 —6 —5 —7 —11 —14 —19 —26 —10 —6 —5 —8 —11 —14 —19 —25

—11 —8 —6 —5 —10 —13 —17 —22 —9 —8 —6 —6 —10 —13 —16 —20


24 36 24—36
—9 —7 —5 —7 —11 —14 —18 —24 —9 —6 —5 —7 —12 —14 —17 —22

5K11757 04/03/99
JM AEROFOIL
Fan Code: 8OJM/20/6/3/... AIR MOVEMENT

800 mm 935 rev/mm 3 Blades 50 Hz


Iso 9001

Performance Data Iso 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000 16000
- I I ____I I -- I I mm in
wg wg
m’/hr 0 5000 10000 15000 20000 25000
180
07

160

0.6
140

0.5
a 120

a
D

a
0,
(I)
100 -0.4

a
0
I—

U
a 0.3

0.

5 0.2

0_i

1vmayan c AT
TAD COOTROL
nhT°cmTIoA
IflTEfTflflTIOflfll, Inc.
0- 0.0

1.2
1.0
32°
0.6
0.6
010
CA

0.2
0.0
1 2 3 4 5 6 7 8
q, — Volume Flow (m’/s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle
—16 —10 —3 —7 —9 —17 —22 —29 —14 —10 —3 —7 —9 —16 —21 —26
8 8
—9 —9 —7 —6 —7 —13 —18 —24 —8 —9 —7 —6 —7 —12 —17 —23
—8 —8 —6 —8 —9 —12 —14 —20 —6 —8 —6 —8 —9 —12 —13 —18
16 16
—4 —6 —8 —12 —11 —14 —16 —21 —3 —6 —8 —12 —11 —14 —15 —19
6 —11 —14 —8 —10 —9 —6 —11 —13 —19
24 36 24 36
—4 —6 —9 —11 —10 —14 —17 —23 — —3 —6 —9 —11 —10 —13 —15 —21

SK11758 04/03/99
JM AEROFOIL
Fan Code: 8OJM/20/6/6/... AIR MOVEMENT
I
ISO 9001
800 mm 935 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000
I mm in
I I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
12
30-

25-

(0 20 - 0.8
0
a)
D
(I)
8)
0
(9 15 0.6
0
I—

(9
U

0. 0.4
10

5 0.2

(AD ConflOt
Iuocrnrlo -

_jIlAflTO(flt._Inc.
0 0.0
0 1 2 3 4 5 6 7 8 9
2.5
8) C
-
2.0

4—
0
0 1.5 -

.— 320
6)
.0
- — ::—
-==:
EEE
1.0

0 -
(I)
.0 0.5 — 16

0.0
0 0 2 3 4 5 6
q, — Volume Flow Is)
3
(m
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle 63 E E E E E
—15 —8 —4 —6 —8 —17 —22 —28 —14 —8 —4 —6 —8 —16 —21 —26
8 8
—16 —10 —7 —5 —5 —14 —19 —26 —16 —10 —7 —5 —5 —13 —19 —24

—15 —7 —3 —8 —10 —18 —23 —29 —14 —7 —3 —8 —10 —18 —22 —27
16 16
—9 —6 —6 —9 —8 —13 —16 —22 —9 —5 —6 —9 —8 —13 —16 —20

—9 —6 —6 —9 —8 —12 —15 —21 —8 —6 —6 —9 —8 —12 —14 —20


24 — 36 24 36
—6 —5 —7 —11 —10 —15 —17 —23 — —6 —4 —7 —11 —10 —14 —16 —21

SK11759 04/03/99
JM AEROFOIL
WOODS
c Fan Code: 8OJM/25/6/6/... AIR MOVEMENT

SO 9001
800 mm 935 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000
mm in
I I I I I
.

I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
10
25-

20 08

(0
0
9)
D 0.6
U)
U)
6)

(0
0
H
C
cc
Ll o. 0.4

5-0.2

flOYCOlEOT
(no COfiflEcOn
(1ISOGIETIOA
IflTIflflflTIOflfll. Inc.
0- -0.0
0 1 2 3 4 5 6 7 8 9
1.8
ci)
1.6
1.4
0 1.2
0
1.0
ci) 0.8
0
0 0.6
U)
.0 0.4
0.2
0.0
0

— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •
E E E Angle E -E EE E
15 —13 —6 —3 —9 —17 —23 —31 —14 —12 —6 —4 —10 —17 —22 —29
8 8
—10 —13 —8 —5 -6 —11 —17 —25 —10 —12 —8 —6 —7 —10 —17 —23
—7 —8 —8 —4 —10 —15 —21 —28 —5 —8 —8 —5 —10 —15 —20 —26
16 16
—4 —5 —9 —11 —13 —15 —19 —25 —4 —5 —9 —11 —13 —15 —18 —23
—6 —7 —7 —7 —10 —14 —17 —22 —B —10 —14 —16 —20
24 36 24—36
—5 —7 —7 —8 —11 —15 —17 —22 —4 —7 —7 —9 —12 —15 —16 —21

SK11761 04/03/99
JM AEROFOIL
Fan Code: 8OJM/2516/9/... AIR MOVEMENT
I C
ISO 9001
800 mm 935 rev/mm 9 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000
mm In
I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
-1.2
30

-1.0
25

20- 08

is- 0.6
0
I—

(ci
U

10- 0.4

5- 0.2

moytincny
AAO COATROt
nrnocIaTIocI
InTERnnrIonnI. Inc
0- -0.0

0
(9 (
0

ci)

0
(I)
-a

q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 7
—11 —9 —6 —5 —8 —15 —24 —30 —9 —7 —6 —6 —9 —15 —24 —28
8 8
—10 —8 —8 —6 —8 —8 —18 —24 —10 —7 —8 —8 —8 —7 —17 —23

16
—9
—10

—10
—8
—7

—9
—5
—5

—6
—6
—8

—6
—10
—9

—10
—16
—13

—13
—21
—18

—16
—27
—24

—20
16
—8
—9

—8
—8
—6

—8
—5
—5

—6
—6
—9

—7
—10
—9

—10
—16
—13

—13
—20
—17
—25
—23 C.
—15 —19
24 36 24 36
—9 —7 —5 —7 —11 —14 —18 —23 — —8 —6 —5 —8 —11 —14 —17 —21

SK11762 04/03/99
JM AEROFOIL
Fan Code: 8OJM/20/4/3/... 1
WOODS’ AIR MOVEMENT
(
800 mm 1440 rev/mm 3 Blades 50 Hz
SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
I wg wg
/hr
3
m 0 10000 20000 30000 40000

40
1.5

( 30
9)
D
0
U)
ci) 1.0

cci
0
H
C
20
cci
U

0.5

10-

0- •0.0
0 2 4 6 8 10 12 14
4.5
( ci)
4.0
3.5
0 3.0
0 2.5
ci)
.0
2.0
0 1.5
U)
.0 1.0 0
0.5
0.0
0 0 2 4 6 8 10 12 14
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freciuency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 Angle E E E E
—16 —17 —8 —3 —8 —11 —19 —24 —13 —16 —8 —3 —8 —10 —17 —21
8 8
—8 —12 —9 —7 —7 —8 —15 —20 —7 —12 —9 —6 —7 —7 —14 —18
7 —10 —8 —6 —10 —10 —13 —17 —6 —10 —8 —6 —10 —10 —12 —14
16 16
—4 —8 —7 —11 —13 —13 —15 —19 —3 —7 —7 —11 —13 —12 —14 —16
—6 —9 —9 —10 —9 —8 —13 —17 5 —8 9 —10 —9 —7 —11 —15
24 36 24—36
—4 —8 —8 —11 —12 —11 —16 —20 —3 —7 —8 —11 —12 —11 —14 —17

5K11763 04/03/99
JM AEROFOIL
Fan Code: 80JM12014161... WOODSI AIR MOVEMENT
C
800 mm 1440 rev/mm 6 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
— I I wg wg
/hr
3
m 0 10000 20000 30000 40000
70 -

2.5
60

2.0

0
a)
C
a)
I)) 40
1.5
Ca
0
F—

Ca
30
IL

1.0
0

20

0.5
10•

flflo COI1TROL
TRSOCIATIOT
ITTETTATIOATL Inc.

0 •0.0
0 2 4 6 8 10 12 14
8
a)
0
7
6
(
5
-o 4
a,
3
0
a) 2

0
0 0 2 4 6 8 10 12 14
q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre FreQuency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 8k Angle E E E E 4k

—21 —14 —8 —5 —7 —10 —19 —24 —19 —12 —7 —4 —7 —10 —18 —22
8 8
—21 —14 —10 - —6 —5 —7 —16 —21 —21 —13 —10 —6 —5 —5 - —15 —19
—19 —14 —6 —4 —9 —12 —20 —25 —18 —14 —6 —3 —9 —11 —18 —23
16 16
—12 —7 —6 —7 —9 —9 —14 —18 —11 —7 —6 —7 —9 —9 —13 —17
—12 —8 —8 —6 —10 —9 —13 —17 8 —7 —6 —9 —9 —12 —16
24 36 24 36
—9 —6 —6 —8 —12 —11 —15 —19 — —9 —5 —6 —8 —12 —11 —14 —17

SK11764 04/03/99
JMAEROFOIL I

Fan Code: 8OJ M/2 5/4/3/s.. WOODSI


AIR MOVEMENT

BS575OPt1
EN 29001
Iso 9001
800 mm 1440 rev/mm 3 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
I I I I mm in
I I I I I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000 35000 40000
1.6
40

1.4

P1.2

C’’ 25 1.0

20 08

15- 0.6

10 0.4

5 0.2

mOVI1IAT
flflo COflTROL
flI5OCIATIO
IflTCflflflTIOAflI. IflC
0 0.0

. 3.5
3.C
2.5
°-
2
. 1.5
1.0
£3

I 0.0
2 4 6 8 10 12
q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall Ievel.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E
—11 —16 —11 —4 —5 —14 —19 —25 —8 —15 —10 —5 —6 —13 —18 —23
8 8
—4 —11 —10 —8 —8 —12 —14 —18 —3 —10 —10 —9 —8 —11 —13 —16

W —13 —16 —18 —9 —9 —9 —10 —12 —14 —16


16 16
—2 —9 —11 —11 —12 —16 —17 —21 —1 —9 —11 —11 —12 —15 —16 —19
s —7 —9 —9 —10 —14 —17 —21 —4 —6 —9 —10 —10 —13 —16 —19
24 32 24—32
—4 —8 —10 —9 —9 —13 —16 —19 —3 —7 —10 —10 —10 —12 —14 —16

SK11765 04/03/99
JM AEROFOIL I
Fan Code: 80JM12514161... wooI” I AIR MOVEMENT
(
800 mm 1440 rev/rn in 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
wg wg
/hr
3
m 0 10000 20000 30000 40000

60 -

2.0
50

2 40
a) 1.5
D
C,)
C,)
a)
0
CO 30
0
I—
C
CO 1.0
U

20

0.5
10

0 -0.0

7
0)
0
6
5
C)
4
0)
.0 3
0
Cl)
2
.0

0
0 2 4 6 8 10 12 14
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Freauency (Hz) Pitch Octave Band Centre Freauency (Hz)
Angle Angle ••

—15 —17 —11 —4 —4 —13 —19 —26 —14 —15 —11 —5 —4 —12 —18 —23
8 8
—10 —15 —12 —7 —4 —8 —13 —19 —10 —14 —12 —9 —4 —7 —13 —18

16
—8
—5
—14
—11
—8
—6
—7
—10
—5
—10
—12
—13
—17
—16
—23
—20
16
7
—4
—14
—10
—8
—6
—8
—10
—5
—10
—12
—13
—16
—15
—21
—19
C
—9 —9 —8 —7 —12 —16 9 —8 —12 —15 —18
24 36 24 36
—5 —9 —9 —8 —9 —13 —16 —20 — —5 —8 —8 —9 —9 —13 —15 —18

SK11767 04/03/99
JM AEROFOIL
, Fan Code: 8OJM/25/419/... WOODS’S AIR MOVEMENT

800 mm 1440 rev/mm 9 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ductedoutlet. Performance ratings do notincludethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
T wg wg
/hr
3
m 0 10000 20000 30000 40000
80
3.0

70

2.5
60

50 2.0

40
1.5

30

1.0

20

0.5
10

0’ -0.0

9
8
7
0 6
5
a) 4
.0
0 3
.0 2

0
0 0 2 4 6 8 10 12 14
q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle E E E •7 E
—10 —11 —10 —6 —5 —11 —18 —27 —9 —11 —8 —7 —5 —10 —17 —24
8 8
—10 —11 —9 —7 —7 —8 —11 —21 —10 —11 —8 —8 —7 —7 —10 —19
—8 —11 —7 —6 —7 —13 —18 —23 —11 —7 —6 —7 —13 —17 —21
16 16
—7 —12 —7 —6 —8 —12 —15 —21 —7 —12 —7 —6 —8 —12 —15 —19

—5 —13 —10 —7 —7 —12 —15 —19 —3 —13 —10 —8 —7 —12 —14 —18
24 36 24 36
—6 —11 —8 —6 —8 —13 —16 —20 — —5 —11 —8 —6 —8 —13 —15 —18

SK11769 04/03/99
JM AEROFOIL
Fan Code: 80JM13112191... WOODS AIR MOVEMENT

800 mm 2910 rev/mm 9 Blades 50 Hz


150 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
12
300

10
250

(6 200
(6 C
0)
0)
a)
0
(6 150 6
0
I
C
IL

0.
100- -4

50- 2

“In
movemEnt
Ann connnoL
IISIOCffiTIOII
lflTAnflnciOnnI. Inc.
0- 0
0 5 10 15 20 25 30

a)
0
C
0
a)
.0
0
(1)
.0
4:

q. — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data 8S848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle E E -E •E
—10 —10 —12 —10 —6 —5 —12 —19 9 10 —11 —8 —6 —5 —11 —17
8 8
—11 —10 —12 —10 —7 —7 —9 —12 —11 —10 —11 —9 —7 —6 —8 —10

16
—7
—7
—8
—8
—12
—13
—7
—8
—7
—7
—8
—9
—14
—13
—19
—17
16
—6
—7
—8
—8
—12
—13
—7
—8
—7
—7
—8
—9
—14
—13
—17
—15
C
—5 —6 —15 —12 —9 —9 —14 —17 —4 —6 —15 —12 —9 —9 —13 —16
24 36 24 36
—7 —7 —13 —9 —7 —9 —14 —17 — —6 —7 —12 —8 —7 —9 —13 —15

SK11772 04/03/99
JMAEROFOIL I

Fan Code: 9OJM/25/8/3/... WOODS


c AIR MOVEMENT

900 mm 695 rev/mm 3 Blades 50 Hz


555750P11
EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 2000 4000 6000 8000 10000 12000 14000 16000
, I I I I I I I mm in
I- I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000
0.40
10-

0.35

(j 8

6
0.30

0.25

0.20

4
0.15

0.10

- 0.05
r

IIGV1mInT
nno cohTot
flTIOCIATIOA
flIIRhIflhIDflflI Inc.
0 -0.00
0 1 2 3 4 5 6 7 8
0.6
0.5 __

-
0.4
;— —
—r——-—---
0.3
z
—_

0.2
—=—=
0.1 ----
zz 16°

0.0
0 1 2 3 4 5 6 7 8
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frenuency (Hz)
Angle •7 Angle 7 -
E
—14 —12 —5 —4 —10 —15 —21 —29 —12 —11 —5 —4 —i0 —15 —20 —26
8 8
—7 —9 —7 —7 —9 —11 —16 —22 —6 —9 —7 —7 —9 —10 —15 —20
—6 —8 —7 —7 —10 —12 —15 —20 —4 —8 —7 —7 —10 —12 —14 —18
16 16
—4 —7 —8 —9 —11 —13 —17 —22 —3 —7 —8 —9 —11 —13 —16 —20
—s 7 —11 —14 —18 —23 — — —7 —9 —11 —14 —17 -21
24 32 24 32
—5 —8 —8 —8 —10 —13 —16 —21 — —4 —8 —8 —8 —10 —12 —15 —19

SK11773 04/03/99
JM AEROFOIL
Fan Code: 9OJM/25/8/6/... AIR MOVEMENT
I C
900 mm 695 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only

Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000
I I I mm in
I I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
16-
- 0.6

14 -

- 0.5
12

a
0
9)
D
10 0.4 C
0
0
a)
0
a 8
0 0.3
F—
C
a
LL
6-
0
- 0.2

4.

- 0.1
2
r
L/
mgVtfltflT
flflb COI1TROL
AHOCIRTIOT
flTETflflTIOflflI. Inc
0- -0.0

1.0
a)
0
0.8 —j-----
r •—•-----——-

32 C
0.6
—__r---.--___
-

a) — —
D10
.0 0.4 —

0
(I)
.0 0.2
0.0
0 U 2 3 4 5 6 9
q, — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:

Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 500 1k Angle E EE E
16 —12 —5 —4 —9 —15 —22 —31 —14 —12 —5 —4 —10 —15 —21 —28
8 8
—12 —10 —9 —5 —6 —10 —16 —24 —11 —10 —9 —5 —6 —9 —16 —22

—13 —11 —6 —3 —9 —14 —20 —28 —12 —11 —6 —3 —9 —14 —19 —26
16 16
—7 —6 —8 —7 —9 —12 —17 —23 —7 —6 —8 —7 —9 —12 —16 —21
—8 —7 —7 —6 —10 —13 —17 —22 —7 —7 —6 —10 —13 —16 —21
24 32 24 32
—6 —7 —7 —8 —10 —13 —17 —22 — —5 —7 —7 —8 —10 —13 —16 —20

SKi 1774 04/03/99


JM AEROFOIL
Fan Code: 9OJM/25/8/9/... WOODS AIR MOVEMENT

900 mm 695 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000
I I mm in
I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
10
25

20 0.8

(EN
15 -0.6

10• -0.4

5 .Q

1.6
N nov’mlnr
flAD COflYDOL
flffOCITIOA
IflTIRflflTIOflflI. Inc.
0- •0.0

1.4

I
1.2
1.0
o.c
0.6
0.4
°j 24°

0.2 I.,

0.6
0 2 6 8 10
q — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 7
—15 —10 —7 —4 —7 —13 —22 —30 —14 —9 —7 —4 —7 —13 —21 —28
8
—14 —8 —8 —6 —6 —9 —17 —24 —14 —7 —8 —6 —6 —8 —16 —22
—13 —8 —6 —5 —9 —14 —20 —28 —11 —8 —6 —5 —9 —14 —19 —26
16 16
—10 —6 —6 —6 —9 —12 —18 —24 —10 —6 —6 —6 —9 —12 —17 —22
—7 —7 —6 —9 —12 —16 —21 —8 —7 —7 —6 —9 —12 —15 —20
24 36 24—36
—8 —6 —6 —8 —10 —13 —17 —23 —7 —6 —6 —8 —10 —13 —16 —21

5K11775 04/03/99
JM AEROFOIL “

Fan Code: 9OJM/25/6/3/.


.
1
wo MR MOVEMENT
C -

900 mm 935 rev/mm 3 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 -

I mm fl
I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000

- 0.7

15 0.6

0.5
a
0
G)
C
C/)
U)
a 0.4

1/)
0
F
C
a 0.3
L1

0.

5- • 0.2

• 0.1

0- •0.0
0 2 4 6 8 10
1.4
1.2 320
(
0
a
0
i2
a
.0
1.0
0.8
0.6
- -____

24°
0
U,
0.4 1
.0
0.2 -= =
0.0
0 0 2 4 6 8 10
q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k Bk Angle •E 7E E E E EE 4k
—11 —14 —6 —4 —8 —14 —20 —27 —8 —13 —6 —4 —8 —14 —19 —24
8 8
—4 —10 —8 —8 —9 —12 —15 —21 —2 —10 —8 —8 —9 —10 —15 —19
—3 —10 —9 —9 —11 —13 —16 —20 —1 —10 —9 —9 —11 —13 —15 —18
16 16
—2 —10 —10 —12 —13 —16 —18 —23 —1 —10 —10 —12 —13 —15 —17 —21
—4 —7 —8 —10 —11 —14 —18 —22 —7 —8 —10 —11 —14 —17 —20
24 32 24 32
—4 —8 —9 —10 —10 —13 —16 —20 — —2 —8 —9 —10 —10 —13 —15 —18

SK11777 04/03/99
JM AEROFOIL
WOODSI
Fan Code: 9OJM/25/6/6/... AIR MOVEMENT

900 mm 935 rev/mm 6 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
I I mm in
I I I I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000 35000 40000
1.2
30

-1.0
25

0.8
C 20

I 15-

10-
0.6

04

5- 0.2

flfl000flTIlOI
nrocrnTlon I
flTChflATGAflt. inc:
0 0- P0.0
0 2 4 6 8 10 12

CI 0 2 4 6 8 10 12
— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch - Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E .
Angle E E E 7E E E
—16 —14 —6 —3 —8 —14 —20 — —14 —13 —6 —3 —8 —14 —20 —25
8 8
—10 —12 —8 —7 —5 —9 —15 —21 —10 —11 —8 —7 —5 —8 —14 —20
—11 —12 —8 —4 —7 —13 —19 —25 —9 —12 —8 —4 —7 —13 —18 —24
16 16
—5 —7 —8 —8 —9 —12 —16 —22 —5 —7 —8 —8 —9 —12 —16 —20
—7 —8 —7 —7 —9 —13 —16 —21 —5 —8 —7 —7 —9 —13 —15 —20
32 24 32
—5 —7 —8 —8 —10 —13 —17 —21 — —4 —7 —8 —8 —10 —13 —16 —19

5K11778 04/03/99
JM AEROFOIL
Fan Code: 9OJM/2516/9/...
900 mm 935 rev/mm 9 Blades 50 Hz
H AIR MOVEMENT
ncI
I C,
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies toair performance only
Performance shown is for installations type D - Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

!min
3
ft 0 5000 10000 15000 20000 25000
L mm in
wg wg
/hr
3
m 0 10000 20000 30000 40000
1.6
40

-1.4

30 -1.2

C
(0
Li
0) 25 1.0
D
CO
CO
0)
0
(0 20- 0.8
C
b
C
(0
U
15- 0.6
0.

10. 0.4

5- 0.2

0- 0.0

4.0

0
0) 3.5
3.0
C
Li 2.5
0) 2.0
-Q 1.5
0
1.0
.0
0.5
0.0
ci

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frecuency (Hz)
Angle E E • E 7E E Angle E E TE 4k 8k
-15 -11 -8 -4 -6 -12 -20 -26 -14 -11

-
-9 -8 -4 -6 -19 -24
8 8
-14 -8 -9 -7 -6 -8 -15 -21 -14 -7 -9 -7 -6 -7 -15 -20

16
-12
-10

-9
-9
-6

-8
-7
-7

-7
-4
-7

-6
-7
-8

-8
-12
-12

-11
-18
-16

—15
-25
-22

-19
16
-11
-9

-7
-9
-6

-8
-7
-7

-7
-4
-7

-6
-7
-8

-8
-12
-11

-11
-17
-16

-14
-23
-20

-18
C
24 36 24 36
-7 -6 -7 -8 -10 -13 -16 -21 - -7 - -6 -7 -8 -10 -13 -15 -19

SK11779 21/02100
JM AEROFOIL
Fan Code: 9OJM/25/4/3/... WOODS
c I AIR MOVEMENT ‘

900 mm 1440 rev/mm 3 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do notinclude the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000
I I I I I mm in
I I I I wg wg
/hr
3
m 0 10000 20000 30000 - 40000 50000

40
1.5

63
0 30
“5
ci)
D
,J)
(6
4) • 1_0
0
(35
0
F
C
20
(‘5
U-

0.

0.5

10

0- 0.0

/‘ 6
‘s__I 5
0
32°
0
4
0 3
6) 24
.0
0 2
(I)
.0 -_

0
U 2 6 8 10 12 14 16
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 5 Angle
—10 —16 —12 —5 —5 —11 —17 —23 —7 —14 —12 —5 —S —10 —15 —19
8 8
—4 —11 —11 —9 —9 —11 —14 —18 —2 —10 —11 —9 —9 —9 —13 —16
—3 —10 —11 —11 —11 - —13 —16 —19 —2 —9 —11 —10 —10 —12 —14 —16
16 16
—3 —9 —12 —12 —13 —16 —18 —21 —1 —8 —11 —12 —13 —15 —16 —19
‘ 9 fl —13 —16 —20 —7 —9 —9 —10 —12 —15 —18
32 24 32
—4 —8 —10 —10 —11 —13 —16 —19 — —2 —7 —10 —10 —11 —12 —14 —16

S.K11781 04/03/99
JM AEROFOIL
Fan Code: 9OJM/25/4/6/... ILWOODS AIR MOVEMENT
C
900 mm 1440 rev/mm 6 Blades 50 Hz
iSO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not iricludethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000
I I I I mm in
wg wg
/hr
3
m 0 10000 20000 30000 40000 50000 60000
70

2.5
60

50 2.0

(0
0
(0
C

0 2 4 6 8 10 12 14 16 18
9
8
7
C
6
5
4
3

0
0 2 4 6 8 10 12 14 16 18
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k Angle E E •7E E
—14 —17 —12 —5 —4 —10 —17 —23 —13 —15 —11 —5 —4 —10 —15 —20
8
—9 —14 —12 —10 —7 —7 —12 —18 —8 —12 —11 —9 —6 —5 —10 —16

16
—10
—6
—15
—10
—11
—8
—7
—10
—4
—9
—10
—12
—16
—15
—21
—19
16
9
—5
14
—9
—11
—8
—7
—9
—4
—9
—9
—10
—14
—13
—19
—17
C
—6 —9 —9 —8 —8 —11 —15 —18 —5 —9 —8 —8 —7 —11 —14 —17
24 32 24 32
—5 —8 —9 —9 —10 —12 —15 —19 — —4 —8 —8 —9 —9 —12 —14 —17

SK11782 04/03/99
JM AEROFOIL
cI
Fan Code: 90JM12514191... AIR MOVEMENT
I
©

900 mm 1440 rev/mm 9 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000 40000
I I I I I mm in
wg wg
/hr
3
m 0 10000 20000 30000 40000 50000 60000

35

80-
• 3.0

2.5
(0
0 60
a)

C,,
(I)
a) 2.0

(a
0
F
C
40
1.5
LL

a.

-1.0

20

0.5
r
(((CO CD((TRO)
U LA 0 0 COt CO A
JflT)flCCfltIOflCCC. lUG.
0- •0.0

14
8) 12
0 10
0
8
8)
.0 6
0 4
Co
.0
C 2
0
0

q. — Volume Flow (m
!s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle
•• •• —;-— Angle E — -- V
—16 —16 —11 —8 —4 —8 —15 —23 —14 —15 —9 —7 —4 —7 —13 —20
8 8
—14 —15 —8 —9 —7 —7 —10 —18 —14 —14 —7 —8 —6 —5 —9 —16
—12 —14 —9 —7 —6 —10 —15 —21 —10 —13 —8 —6 —5 —9 —13 —19
16 16
—9 —12 —7 —7 —8 —10 —14 —19 —8 —11 —6 —7 —7 —9 —13 —17
—11 —9 —8 —8 —10 —14 —17 —5 —10 —8 —8 —7 —10 —13 —16
24 36 24 36
—6 —9 —8 —8 —9 —12 —15 —19 — —6 —9 —7 —7 —9 —11 —14 —17

SK11783 04/03/99
JM AEROFOIL
WOODS
Fan Code: 1 OOJ M12518131... AIR MOVEMENT
Cs..
1000 mm 695 rev/mm 3 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000
mm in
wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000
12

10 -
0.4

a 8
0
a 0.3 C
D
0
0
a
0
a 6
0

C
a 0.2

0.1
2

r
movEmEnT
flD COI1TROL
flITOCIATIO
IvycmrnTIOflnI. Inc.
0 -0.0

a
0
C
0 0.6 -

0
a
.0 0.4
0
(I)
.0 0.2 —
°

80
0.0
0 0 2 4 6 8 10
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle ••
TEf 8k Angle EE EE
—14 —13 —6 —4 —7 —13 —18 —26 —12 —13 —6 —4 —7 —12 —17 —23
8 8
—7 —9 —8 —7 —7 —11 —15 —20 —5 —9 —8 —7 —7 —9 —14 —19

16
—4
—9
—8
—8
—9
—8
—9
—9
—11
—11
—13
—15
—17
—19
—21
16
—4
—3
—9
—8
—8
—9
—6
—9
—9
—11
—11
—13
—13
—15
—16
—19 C
—6 —7 —8 —9 —10 —13 —18 —22 —4 —7 —8 —9 —10 —13 —16 —20
24 32 24—32
—4 —8 —9 —9 —10 —13 —16 —20 —3 —8 —9 —9 —10 —12 —15 —18

SK11785 04/03/99
JM AEROFOIL
Fan Code: 1 OOJ M12518161...
WOODS
( AIR MOVEMENT
I
Iso 9001
1000 mm 695 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
I wg wg
/hr
3
m 0 5000 10000 15000 20000 25000 30000 35000 40000

0.7

0.6
15

- 0.5
CO
0
6)
D
U)
U)
ci) 10 0’

a
0
I
C
a 03
U.

0.

5. -0.2

- 0.1

Cmtnr
fib COATfOC
fffOCIAliOf
lfTfCfffTIOflfll. Inc.
0- 0.0

1.6
C, 1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0 2 4 6 8 10 12
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 8k Angle -E - -•

‘ — 19 27 —14 —13 -6 —4 —7 —13 —19 —25


8 8
—10 —10 —11 —7 —5 —8 —14 —21 —10 —10 —11 —7 —5 —7 —14 —20
—15 —13 —7 —3 —7 —14 —20 -27 —13 —13 —7 —3 —7 —14 —19 —26
16 16
—7 —8 —8 —7 —8 —11 —16 —22 —7 —8 —8 —7 —8 —11 —15 —21
—8 —8 —7 —7 —9 —13 —17 —23 —7 —8 —7 —7 —9 —13 —16 —21
24 32 24 32
—5 —7 —8 —9 —9 —13 —16 —21 — —4 —7 —8 —9 —9 —12 —15 —20

SK11786 04/03/99
JM AEROFOIL
Fan Code: 100JM/25/8/9/... wooós’ AIR MOVEMENT
C..
1000 mm 695 rev/rn in 9 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

!min
3
ft 0 5000 10000 15000 20000 25000
mm in
I T wg wg
/hr
3
m 0 10000 20000 30000 40000
-1.0
25

20 08

a
CO

0.6
C.
0
15-
0
a
0..
CO
0
F—

CO
10- 0.4

5 0.2

0 0.0

a
0
C
-D
a
0
0
0
-D

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 11 4k Angle E ••E E E
—20 —14 —9 —4 —5 —11 —18 —27 —19 —13 —9 —4 —5 —10 —17 —25
8 8
—18 —10 —10 —7 —4 —8 —14 —21 —18 —10 —10 —7 —4 —7 —14 —20
—16 —12 —7 —4 —6 —11 —18 — —16 —12 —7 —4 —6 —11 —17 —25
16 16
—10 —7 —8 —6 —8 —11 —16 —23 —10 —7 —8 —6 —8 —11 —15 —21
—8 —7 —8 —7 —8 —11 —15 —21 —7 —8 —7 —8 —11 —15 —20
24 36 24—36
—6 —6 —8 —9 —9 —13 —17 —22 —6 —5 —8 —9 —9 —12 —16 —21

SK11787 04/03/99
JM AEROFOIL ftCI
( Fan Code: 100JM/25/6/3/... I AIR MOVEMENT

1000 mm 935 rev/mm 3 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
I I mm in
I I I I wg wg
/hr
3
m 0 10000 20000 30000 40000
-0.8
20

- 0.7

15 -0.6

(9
0
(9 • 0.5
D
U)
C,)
a)

(9 o. 0.4
0
I—
C
C,)
U-
• 0.3
a

5. 0.2

0.1

flTEflflRTIOflflI. IAC.

0• 0.0
0 2 4 6 8 10 12 14
2.5
C 0
2.0 - -

— -
0 1.5
•0 — —

240
1.0 :::E—
0
U)
0.5 --

0.0
0 0 2 4 6 8 10 12 14
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle 7
—11 —15 —8 —4 —6 —12 —17 — —8 —14 —8 —4 —6 —12 —16 —20
8 8
—4 —11 —9 —9 —8 —11 —15 —19 —2 —11 —9 —9 —8 —10 —14 —18
—11 —10 —10 —10 —13 —16 —1 —11 —10 —10 —10 —12 —14 —17
16 16
—2 —10 —11 —12 —12 —15 —18 —22 —1 —10 —11 —12 —12 —14 —17 —19
—7 —8 —10 —10 —13 —17 —20 —7 —8 —10 —10 —13 —16 —19
24 32 24 32
—3 —9 —9 —11 —10 —13 —17 —19 — —2 —9 —9 —11 —10 —12 —15 —17

SK11792 04/03/99
JM AEROFOIL
Fan Code: 1 OOJ M/251616L.. WOODS AIR MOVEMENT
C
1000 mm 950 rev/mm 6 Blades 50 Hz
BS5750P11

ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000
I I I mm in
I I I I wg wg
/hr
3
m 0 10000 20000 30000 40000 50000
1.4
35

- 1.2
30

25 1.0

C
Cs

11)
D
C’)
Cl)
9)
0..
20 - 0.8

Cs
0
I
C 06
Cs
U-

a-

10 0.4

5 0.2

movImEny
1110 00110101
0100101100
mc.
!lIIIlflflTIOflflI.
0 0.0

9)
0
(-.
0
6)
-a
0
C’)
.0

0 2 4 6 8 10 12 14 16
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle .
8k Angle E 1E E E E 4k

—16 —15 —7 —4 —6 —12 —18 —24 —14 —14 —7 —4 —6 —12 —17 —22
8 8
—9 —12 —9 —9 —5 —8 —13 —19 —9 —11 —9 —9 —5 —7 —13 —18
—14 —15 —8 —4 —5 —12 —18 —24 —13 —15 —8 —4 —5 —12 —17 —22
16 16
—6 —9 —8 —7 —7 —11 —15 —20 —6 —9 —8 —7 —7 —10 —14 —19
—9 —7 —7 —8 —12 —16 —20 —6 —9 —7 —7 —8 —12 —15 —19
24 32 24 32
—5 —8 —8 —9 —9 —12 —16 —20 — —4 —8 —8 —9 —9 —12 —15 —18

SK11793 04/03/99
JM AEROFOIL “ I
Fan Code: 1 OOJ M12516191... woo CI
AIR MOVEMENT

1000 mm 960 rev/mm 9 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000
I I I I I mm in
I I I I wg wg
m
/
3 hr 0 10000 20000 30000 40000 50000 60000

40 -

15

(9
0 30 -

a)
D
(I)
a) - 1.0

(0
0
F—
C 20
(9
IL

a-

0.5

10

0- -0.0

a
0

-D
a)
.0
0
-a

— Volume Flow 3
(m
! s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle
500 1k 8k -E E E
—21 —14 —11 —4 —4 —9 —17 —23 —20 —12 —11 —4 —4 —9 —16 —21
8 8
—18 —10 —10 —8 —4 —8 —13 —18 —18 —8 —10 —8 —4 —6 —13 —17
—16 —12 —10 —4 —6 —10 —17 —24 —14 —12 —10 —4 —6 —10 —16 —22
16 16
—10 —7 —8 —6 —7 —11 —15 —20 —10 —7 —8 —6 —7 —10 —14 —19
-8 -8 —7 —7 —11 —15 —19 —7 —7 —8 —7 —7 —11 —14 —18
24 36 24—32
—8 —6 —8 —9 —9 —12 —16 —20 —5 —6 —8 —9 —9 —12 —15 —18

SK11794 04/03/99
JMAEROFOIL I
Fan Code: 1 OOJM/25/4/3/...
I WOODS
I
4 AR MOVEMENT %‘

1000 mm 1440 rev/mm 3 Blades 50 Hz


BS5750Pt1

Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000
2.0
50

40
-1.5

(0
a

300
30
C

j 200 20
1.0

0.5

10-

r
vmnr
(AD COATROL
TJIOCIATIOA
Ifl1ETTATIOTTI. CC.
0 0.0

a
0
(
0
a
.0
0
(I)
.0

q. — Volume Flow (m
Is)
3
If t is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E EE E
—9 —16 —14 —7 —5 —9 —14 —20 —6 —14 —14 —7 —4 —8 —13 —16
8 8
—3 —10 —13 —11 —10 —10 —14 —18 —2 —10 —12 —11 —10 —9 —13 —16
—2 —10 —14 —13 —12 —13 —16 —19 —1 —10 —14 —13 —12 —13 —14 —16
16 16
—2 —9 —13 —14 —14 —15 —18 —21 —1 —9 —13 —14 —14 —15 —17 —19
—9 —9 —11 —12 —16 —19 —9 —9 —11 —12 —14 —17
24 32 24 32
—3 —8 —11 —11 —12 —13 —16 —19 — —2 —7 —11 —11 —12 —12 —14 —17

SK11799 04/03/99
JM AEROFOIL
BSI
Fan Code: 1 OOJM/25/4/6/...
4 ws’
1I AIR MOVEMENT

1000 mm 1450 rev/mm 6 Blades 50 Hz


EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
wg wg
m’/hr 0 20000 40000 60000 80000
80
3.0

70

2.5
60

I— cc
a-
a) 50 2.0
U)
ci,
6)
ci
a 40
0 - 1.5
I—

a
U
30

• 1.0

20

• 0.5
10-

movmn
ciflO COI1TROt
RTflOCITIOfl
IflTflRflRTIOflflI. mc.
0- •0.0

14
C,, 12
10
8
6
4
2
0
0 5 10 15 20 25
q, — Volume Flow (m’/s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •
1k Angle - -
-E ‘E 8k
—13 —17 —13 —6 —5 —8 —14 —20 —12 —15 —12 —6 —4 —8 —13 —18
8 8
—7 —12 —12 —12 —8 —6 —10 —16 —6 —11 —11 —12 —8 —5 —9 —14
—10 —15 —13 —7 —4 —8 —15 —20 —9 —15 —13 —7 —4 —8 —14 —18
16 16
—5 —9 —10 —10 —8 —10 —13 —18 —4 —9 —10 —10 —8 —9 —12 —16
—9 —9 -.8 —8 —10 —14 —18 —6 —9 —8 —7 —8 —10 —13 —17
24 32 24 32
—5 —7 —9 —10 —11 —11 —15 —18 — —4 —7 —9 —10 —10 —11 —14 —16

SK11800 04/03/99
JM AEROFOIL
BSI
Fan Code: 1 OOJ M/25/4/9/...
WOOC I
‘j

1000 mm 1470 rev/mm 9 Blades 50 Hz


BS575OPt1
EN 29001
C I AR MOVEMENT

ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
I I I I I mm in
I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
120-

100

a 80
6)
D
3 C
0
0
6)

a 60
0
I

a -2
U

0.
40

20

flISOGIATIOII
IflTflflflTJOflflt. IflC.
0- 0
0 5 10 15 20 25 30
25
a)
0
20 C
0 15
a)
.0 10
0
0
.0 5
0
0 5 10 15 20 25 30
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 63 Angle -
E E 4k 8k
—21 —21 —14 —9 —4 —6 —12 —19 —20 —20 —13 —9 —4 —5 —11 —16
8 8
—17 —18 —10 —10 —6 —5 —9 —15 —17 —18 —9 —10 —6 —3 —8 —13

-e —15
—10
—16
—11
—12
—8
—7
—8
—4
—7
—7
—8
—12
—12
—19
—17
16
—14
—10
—16
—11
—12
—7
—6
—8
—4
—6
—7
—8
—11
—11
—17
—15
C.
—8 —9 —8 —8 —8 —8 —13 —16 —7 —9 —8 —8 —8 —8 —12 —15
24 36 24 36
—6 —8 —7 —9 —10 —10 —14 —18 — —6 —8 —6 —9 —10 —10 —13 —16

SK118O1 04/03/99
JM AEROFOIL I,,

Fan Code: 1 OOJM/31/4/9/...


WOODS
I AIR MOVEMENT

1000 mm 1470 rev/rn in 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
. I mm in
I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
120

100

C a)
80
-3
C,)
C,)
,1)
0
CO 60
0
F
C
CO
U

0.
40

20

ICR
moYlInlAr
CR0 COATOI
R000IATIOR
IRTE000TI000I. Inc.
0-9
0 5 10 15 20 25 30

6)
0

0
a)
.0
0
C,)
.0

0 0 5 10 15 20 25 30
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - .
Angle E E
—21 —21 —14 —9 —4 —6 —12 —19 —20 —20 —13 —9 —4 —5 —11 —16
8
—17 —18 —10 —10 —6 —5 —9 —15 —17 —18 —9 —10 —6 —3 —8 —13

—15 —16 —12 —7 —4 —7 —12 —19 —14 —16 —12 —6 —4 —7 —11 —17
16 16
—10 —11 —8 —8 —7 —8 —12 —17 —10 —11 —7 —8 —6 —8 —11 —15

—8 —9 —8 —8 —8 —8 —13 —16 —7 —9 —8 —8 —8 —8 —12 —15


24 36 24 36
—6 —8 —7 —9 —10 —10 —14 —18 — —6 —8 —6 —9 —10 —10 —13 —16

5K11802 04/03/99
JM AEROFOIL
BSI WOOC I
Fan Code: 1 OOJ M/40/4/9/... AIR MOVEMENT
C
1000 mm 1470 rev/mm 9 Blades 50 Hz
EN 29001
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
I I I I I mm in
I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
Iso 5801 140 -

ivr
TypeD -

Air Density 1.2 kg/rn


3 I — —

120 -

100 4
(0

U)
D
C!
(0
(0
U) 80
0 3
(0
0
I—
(0
60
w
2

40

-1
20-
V
vlm’nr
(lID COflTOt
IIlISOCITIOfl
IflTIRflflTIOADI. Inc.
0 -0
5 10 15 20 25 30

ci)
35
30
25
C!
0
0
0
20
U) 15
.0
0
(0
10
.0
5
0
a-
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 4k Angle E E E E 7 E
—9 —10 —7 —5 —8 —13 —19 —27 —7 —6 —4 —9 —13 —18 —25
8 8
—10 —12 —7 —7 —7 —9 —13 —22 —6 —9 —4 —7 —7 —8 —12 —21

16
—7
—6

s
—11
—10

—9
—8
—6

—9
—5
—7

—5
—8
—10

—15
—11
—10

—16
—15
—12

—17
—23
—21

—20
16
s
—2

—2
—7
—6

—5
—7
—5

—7
—6
—8

—4
—10
—12

—14
—11
—11

—15
—15
—11

—16
—22
—20

—19
C
24 40 24 40
—6 —8 —8 —5 —15 —17 —18 —23 — —3 —4 —6 —4 —14 —16 —17 —22

SK11804 04/03/99
JMAEROFOIL I
BSI WOODSI
Fan Code: 112JM/40/10/6/... I AIR MOVEMENT ‘

1120 mm 575 rev/mm 6 Blades 50 Hz


EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

ft’/min 0 5000 10000 15000 20000 25000


I I mm In
I I I wg wg
/hr
3
m 0 10000 20000 30000 40000
ISO 5801 \60 -
0.7
lvi
-

TypeD --

160 Air Density 1.2 kg/rn


3

0.6
15-
140

- 0.5
120

5)
cc, 100 o. 0.4

80
(0 • 0.3
U-

& 60

5 0

40

• 0.1
20 r

cccl,
sOnlcrnr
cnn COAtnoc
ceocinnion
inccflnncclonni, Inc.
0 0- 0.0
0 2 4 6 8 10 12 14
-

ci)

0
0
ci)
.0
0
cc)
.0

q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle - 8k Angle -•E - - -. iE -

—10 —5 —4 —8 —16 —21 —28 34 —5 —5 —8 —15 —21 —28 —33


8 8
—7 —8 —6 —6 —11 —16 —22 —30 —4 —7 —6 —6 —10 —15 —22 —29

—7 —6 —6 —7 ‘ —12 —17 —24 —29 —5 —6 —7 —12 —16 —24 —28


16 16
—5 —5 —9 —10 —12 —16 —22 —29 —2 —4 I —9 —10 —12 —15 —22 —28
—6 —5 —8 —6 —12 —16 —20 —23 —4 —4 —8 —8 —12 —15 —20 —22
24 32 24 32
—6 —4 —9 —9 —13 —17 —20 —23 — —3 —3 —9 —9 —13 —16 —20 —22

SK11818 04/03/99
JMAEROFOIL
Fan Code: 11 2JM/40/1 0/9/... WOODS) AIR MOVEMENT

1120 mm 575 rev/mm 9 Blades 50 Hz


BS5ThOptl

Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000
mm in
I I I I wg wg
/hr
3
m 0 10000 20000 30000 40000 50000
-1.0
25

20- 0.8

(0

150
15- 0.6
C,

L 100 10 -
0.4

5 0.2

,tmcnr
(RD COATROL
(COCIRTIOR
tnTEnvrnrIonrn. Inc.
0• 0.0

2.5
2.0
C
1.5
0

0.5
I 0.0

q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k Angle E
—4 —7 —15 -21 —29 —35 —8 —3 —4 —6 —15 —21 —28 —33
8 8
—10 —9 —6 —4 —10 —15 —23 —31 —6 —6 —6 —4 —10 —15 —22 —30

16
—12
—6

—6
—6
—8

—7
—4
—6

—5 —9
—7
—7
—12
—9

—13
—19
—13

—14
—27
—21

—20
—32
—27

—25
16
—3 —5

—4
—3
—5

—4
—7
—6

—8
—14
—10

—12
—20
—14

—14
—26
—20

—20
—32
—26

—24
C
24 36 24 36
—5 —7 —6 —10 —13 —14 —21 —26 — —2 —4 —5 —9 —12 —14 —20 —25

SK11819 04/03/99
JMAEROFOIL I

Fan Code: 11 2J M/50/1 0/12/... WOODS AIR MOVEMENT

1120 mm 575 rev/mm 12 Blades 50 Hz


BS5750R1
EN 29001
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor iristallationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000
mm in
- wg wg
/hr
3
m 0 10000 20000 30000 40000
25-

20- 08

f CO
0
a 150
15 -0.6
U)
C/)
a
0
CO
0
I—

CO 100
U 10 04

0.

5 0.2

0- 0.0

3.5
a 3.0
0 2.5
0
0
2.0
a 1.5
-D
0
U)
1.0
-D
0.5
0.0
0 0 2 4 6 8 10 12 14
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • Angle •• 1k
—15 —5 —6 —6 —11 —18 —24 33 —12 —2 —6 —7 —11 —16 —21 —31
8 8
—14 —4 —7 —6 —11 —16 —21 —31 —11 —2 —6 —8 —11 —14 —18 —29
—13 —4 —7 —7 —11 —17 —24 —31 —11 —1 —7 —7 —11 —16 —21 —28
16 16
—13 —2 —9 —8 —12 —16 —21 —29 —10 1 —9 —8 —12 —14 —18 —27
—9 —4 —8 —8 —12 —15 —19 —24 —6 —1 —8 —8 —13 —13 —16 —21
24 36 24 36
—9 —3 —9 —9 —12 —15 —20 —25 — —7 —1 —9 —8 —13 —13 —17 —23

SK11820 04/03/99
JM AEROFOIL I’cI
I
Fan Code: 11 2J M14018161... * I
woo

AIR MOVEMENT

1120 mm 720 revlmin 6 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft

/hr
3
m
0

0
5000
I

10000
— 10000
— I

20000
15000
I

30000
20000
I

40000
25000
I
30000

50000
I
35000
I

60000
mm
wg
in
wg

1.2
30-

1.0
25

20 0.8

a) (
C))
C))
8)

Cc 15 0.6
0
I—
C
CO
w

10 0.4

5 - 0.2

V
flcOvLflC ER?
nnD COflYRCI
nfloCIaTIoR
COYEROATIOflflI. Inc.
0 -0.0

4.0
6)
0
3.5
3.0
(-
2.5
ci)
2.0
1.5
0
C)) 1.0
.0
0.5
0.0
a- 0 2 4 6 8 10 12 14 16 18
q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k Angle E ‘E E EE
—10 —7 —4 —6 —13 —20 —25 —32 —8 —6 —4 —6 —13 —19 —26 —31
8 8
—7 —8 —7 —6 —9 —14 —19 —28 —4 —8 —7 —6 —9 —14 —20 —27

—7 —6 —7 —11 —15 —21 —27 —4 —6 —6 —7 —10 —15 —22 —26


16 16
—4 —6 —8 —10 —12 —15 —20 —27 —2 —4 —9 —10 —11 —15 —20 —26

—5 —6 —8 —8 —11 —15 —18 —22 —3 —5 —8 —8 —11 —15 —18 —21


24 32 24 32
—5 —5 —8 —9 —12 —16 —19 —23 — —3 —4 —8 —10 —12 —15 —19 —22

SK11809 04/03/99
JM AEROFOIL I

Fan Code: 11 2J M/40/8/9/... wool” I AIR MOVEMENT

ssopti
1120 mm 720 rev/mm 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000 40000
I I I I mm in
I I I I I wg wg
/hr
3
m 0 10000 20000 30000 40000 50000 60000
-1.4

1.2
30

25- 1.0

20- -0.8

15 -0.6

10• •Q4

5.02

miD COUTI1OI
flISOCIRTIOfl
flTIIlflATIOU)i. IflC
0- •0.0

- 6
5
4
3
II)

0
..,

-z -__ 24U
U) —=: ._

1b
.

0 5 10 15 20
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle E E E •E
—13 —7 —4 —6 —12 —19 —26 —4 —5 —13 —19 —25 —31
8 8
—16 —8 —7 —4 —8 —13 —20 —29 —13 —4 —7 —4 —8 —13 —19 —27
—14 —7 —4 —6 —10 —16 —24 —30 —10 —5 —4 —6 —12 —17 —24 —30
16 16
—12 —6 —7 —7 —8 —11 —18 —25 —7 —2

-
—6 —6 —9 —12 —17 —24
—8 —6 —5 —9 —12 —14 —18 —24 —3 —3 —8 —11 —13 —18 —23
24 36 24—36
—7 —5 —5 —10 —13 —14 —18 —25 —4 —1 —4 —9 —12 —13 —18 —24

5K11810 04/03/99
JMAEROFOIL
, Fan Code: 11 2J M/50/8/1 2/...
8S575oPt1

Iso 9001
1120 mm 720 rev/mm 12 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000
I I I I I mm in
I I I I wg wg
/hr
3
m 0 10000 20000 30000 40000 50000 60000
1.6
40

350 •1.4

300
30- -1.2

0)

0
D
250 25- C
(I)
U)
0
0
(0
200 20- 0.8
0

(9
U
150 15- 0.6
0

100 10 0.4

50 5 0.2

flAil COATROL
flITOCIATIOA
flTrnflflT,Oflfll. Inc.
0 0 0.0
0 2 4 6 8 10 12 14 16 18

0
0 (
0
0
0
.0
0
U)
.0

0 2 4 6 8 10 12 14 16 18
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E -. 4k Angle 4k

—18 —5 —8 —5 —9 —16 —22 —30 —15 —2 —8 —6 —9 —14 —19 —28


8 8
—17 —4 —8 —5 —10 —15 —19 —28 —14 —2 —7 —7 —10 —13 —16 —26

16
—15
—14

—9
—4
—2

—4
—8
—10

—8
—6
—8

—8
—10
—11

—11
—16
—14

—14
—22
—19

—18
—29
—27
16
—13
—12

—7
—1
1

—2
—7
—9

—7
—6
—8

—8
—10
—11

—12
—14
—13

—12
—19
—16

—15
—27
—25

—20
C
24 36 24— 36
—10 —3 —9 —9 —11 —15 —19 —24 —7 —1 —8 —9 —12 —12 —16 —22

SK11811 04/03/99
JM AEROFOIL
Fan Code: 112JM/40/6/6/... LAIR MOVEMENT

1120 mm 960 rev/rn in 6 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
I I I mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000
-2.0
50-

40
• 1.5

1 a

300
:3
U)
30
U)
6)
0
a 1.0
0
I—

200 20

- 0.5

10-

r
novtmInr
flflD COUTROL
Uocrn?Ion
IfltERflflTIOflfll.
0- 0.0

a
0

0
a
.0
0
U)
.0

— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k 4k 8k Angle E E E — E E
—10 —10 —5 —6 —11 —19 —23 —31 —8 —7 —5 —5 —10 —18 —23 —29
8 8
—9 —10 —10 —7 —9 —14 —19 —27 —5 —6 —9 —6 —8 —12 —18 —25
—6 —10 —8 —8 —11 —16 —21 —28 —2 —8 —6 —7 —10 —15 —20 —26
16 16
—4 —7 —9 —13 —13 —16 —20 —27 —1 —5 —9 —12 —12 —16 —20 —26
—9 —8 —10 —12 —15 —19 —23 —2 —7 —9 —9 —12 —14 —18 —22
24 32 24 32
—4 —7 —7 —11 —12 —16 —20 —24 — —2 —6 —8 —11 —12 —15 —20 —22

SK11812 04/03/99
JM AEROFOIL
Fan Code: 11 2J M14016191... WOODS AIR MOVEMENT
C
1120 mm 960 rev/mm 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
I- wg wg
/hr
3
m 0 20000 40000 60000 80000
70

2.5
60

50 2.0

(0
0
6)
(
(/)
6)
a) 40
a 1.5
(0
0
I—
C
(0
30
w
1.0
0

20 -

- 0.5
10-

flAb 00611(01
n000rnfllon
(flflflflfltiOflfll. Inc.
0- •0.0

14
6)
0
12
10
C
0
8
9) 6
.0
0 4
(6
.0
2
0
a-

q, — Volume Flow (m’/s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle E E
—15 —11 —6 —5 —10 —18 —24 —31 —12 —7 —4 —4 —10 —17 —22 —29
8 8
—15 —9 —9 —6 —7 —12 —18 —27 —10 —6 —8 —5 —6 —11 —16 —24
—14 —13 —5 —5 —9 —14 —21 —29 —10 —10 —4 —5 —9 —15 —20 —28
16 16
—12 —7 —7 —8 —9 —11 —16 —24 —7 —4 —5 —7 —9 —11 —14 —22
—8 —8 —5 —11 —12 —15 —17 —24 9 H —14 —16 —22
24 36 24—36
—8 —6 —5 —11 —13 —15 —17 —25 —4 —3 —3 —10 —11 —14 —16 —23

SK11813 04/03/99
JMAEROFOIL I
Fan Code: 112JM/50/6/12/... IWOODS AIR MOVEMENT

EN 29001
Iso 9001
1120 mm 960 rev/mm 12 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
I— wg wg
lhr
3
m 0 20000 40000 60000 80000
70

2.5
60 -

50- ‘2.0
a
a
D

a
Q) 40
a- 1.5
a
0
I

a 30
Lj

1.0
0.

20

0.5
10’

nil’
movmnr
flflD COflTOL
flISOCIATIOfl
flTEFiflflTlOflfli, inc
0’ -0.0

q, — Volume Flow (m
fs)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle -— -- —;-- —;:—
—18 —10 —6 —5 —8 —14 —19 —27 —14 —8 —4 —6 —7 —12 —16 —24
8 8
—17 —10 —5 —5 —7 —13 —17 —24 —13 —8 —3 —7 —7 —11 —14 —22
—13 —9 —5 —7 —8 —14 —20 —27 —10 —7 —3 —6 —8 —12 —16 —24
16 16
—12 —8 —4 —8 —9 —13 —17 —24 —9 —7 —1 —8 —9 —11 —14 —21
7 8 —6 —8 —10 —14 —16 —21 —5 —6 —4 —8 —10 —12 —13 —19
24 36 24 36
—8 —7 —5 —9 —10 —14 —17 —22 — —6 —5 —3 —9 —10 —12 —14 —20

5K11814 04/03/99
JM AEROFOIL
Fan Code: 112JM/40/4/6/... woo AIR MOVEMENT
I
1120 mm 1470 rev/mm 6 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only

Performance shown is for installations type D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000
I I I rrim in
I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
120

1oo

a 80
a-
a
D
-3 (-
0)
U)
a
0
a 60-
0

C
a
Ll

0
40

20

0 0
0 5 10 15 20 25 30 35
. 35
30
25
20
15
10
.0

I 0
0 5 10 15 20 25 30 35
0
q — Volume Flow (m
Is)
3
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle 4k
—8 —11 —8 —5 —7 —13 —21 —26 6 —9 —8 —5 —7 —13 —21 —25
8 8
—6 —8 —10 —8 —7 —10 —15 —20 —5 —6 —9 —8 —7 —10 —16 —19

16
—3
—2
—10
—9
—10
—9
—9
—12
—9
—14
—13
—16
—18
—19
—24
—23
16
—1
0
—8
—7
—10
—9
—9
—12
—9
—13
—13
—15
—19
—19
—23
—22
C-
24 32
—3
—9
—9
—9
—8
—11
—11
—11
—13
—14
—15
—18
—19
—21
—22
24
— 32
—1
—1
—7
—7
—8
—7
—11
—11
—11
—13
—13
—14
—18
—19
—20
—21

5K11815 04/03/99
JM AEROFOIL
WOODi
Fan Code: 11 2JM14014191... AIR MOVEMENT

1120 mm 1470 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D—Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000 80000
I • I • I I •I mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
160-
6

140 -

.5
120

(6

ci) 100 4
cc)
cc)
ci)

(6 80
0 3
I

(0
U
60
C.

40

20

0 -0
0 5 10 15 20 25 30 35 40
50
C) C
40
- 30
0
(6
e0 20
cn
10

aE 0 5 10 15 20 25 30 35 40
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 Angle . -
•7 — 8k
—15 —14 —7 —4 —6 —12 —19 —26 —12 —11 —6 —4 —6 —12 —18 —25
8
—13 —17 —8 —8 —4 —8 —13 —20 —9 —14 —6 —7 —5 —8 —12 —18
—15 —14 —7 —4 —6 —10 —16 —24 —11 —11 —6 —5 —7 —11 —16 —24
16 16
—12 —12 —6 —7 —7 —9 —11 —18 —7 —9 —4 —7 —8 —9 —10 —17
—9 —8 —6 —10 —13 —15 —19 4 —6 —6 —5 —10 —13 —14 —18
24 36 24 36
—7 —8 —6 —6 —11 —14 —15 —19 — —4 —5 —4 —5 —10 —13 —14 —18

5K11816 04/03/99
JMAEROFOIL
Fan Code: 11 2J M/50/4/1 2/... C
1120 mm 1470 rev/mm 12 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000 80000
I I I I I I rum in
I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
160

140

5
120

cc

ci) 100 .4
U)
C’)
ci)

(0 80-
0 3
H

cc
LL
60
a-
2

40 -

20 -

1110 COI1TOOL
flITOCIATIOA
IATCRO11TIOAOI. mc.
0- 0

0
ci)
C
-o
ci)
0
0

q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •7 Angle E E E •7E E
—17 —18 —5 —8 —5 —9 —16 —21 —13 —17 —3 —8 —4 —7 —13 —19
8
—16 —17 —5 —8 —5 —10 —15 —19 —13 —16 —3 —8 —5 —7 —12 —17

16
—11
—11
—15
—14
—5
—3
—8
—10
—6
—8
—10
—11
—16
—14
—22
—19
16
—8
—8
—13
—12
—3
—1
—7
—9
—6
—8
—8
—9
—13
—12
—19
—17
(
—6 —10 —5 —9 —9 —12 —15 —19 —4 —8 —4 —8 —9 —10 —12 —16
24—36 24—36
—7 —10 —4 —10 —10 —12 —15 —19 —5 —8 —3 —9 —10 —10 —12 —17

SK11817 04/03/99
JMAEROFOIL I
I
Fan Code: 1 25JM/40/1 0/6/... I WOODS AIRM0VEMENT*’

1250 mm 575 rev/mm 6 Blades 50 Hz


EN 29001
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 5000 10000 15000 20000 25000 30000 35000 40000
I I I I I I I I mm in
I wg wg
/hr
3
m 0 10000 20000 30000 40000 50000 60000
-0.8
20

0.7

15 0.6

C 0.5
U)
C/)

0
10- -0.4
b
C
a
0.3

5-0.2

0.1

AAO COC1TOL
CIffOCIATICA
ATErnAATI0CIAI. InC
0 -0.0

3.0
2.5
2.0
0
8)
1.0
U,
0.5
I 0.0
0

q — Volume Flow (m
/s)
3

Sound Data 8S848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle •
1k
—H —4 —4 —9 —17 —23 —27 —32 —8 —4 —4 —9 —17 —22 —28 —31
8 8
—14 —10 —4 —5 —11 —16 —21 —31 —11 —9 —4 —5 —11 —16 —21 —30
—8 —4 —6 —11 —17 —23 —28 8 —7 —4 —6 —11 —17 —24 —27
16 16
—6 —5 —8 —8 —11 —14 —19 —26 —4 —4 —9 —8 —11 —14 —19 —25
—8 —6 —6 —6 —13 —17 —20 —6 —5 —6 —6 —13 —16 —20 —21
24 32 24—32
—6 —4 —9 —9 —13 —15 —18 —22 —3 —3 —9 —9 —13 —15 —18 —21

SK11836 04/03/99
JMAEROFOIL
.

Fan Code: 1 25J M/40/1 0/9/... C


1250 mm 575 rev/mm 9 Blades 50 Hz
BS575OP11

ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
I I I mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000
1.2
30

1.0
25

CO 20 -0.8
ci) C
cc,
cc,
ci)
0
CO 15 -0.6
0
I—
C
CO
LL

0
10- 0.4

5- 0.2

movunEr
flflD COCcTOL
flITOCIRTIO
II1TCRflATIOAflI. Inc.
0 0- -0.0
0 5 10 15 20 25
5
ci)
0
4 C)
0 3
ci)
.0 2
0
cc,
.0

0
0 5 10 15 20 25
q — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E E
—14 —6 —3 —7 —15 —23 —29 —36 —11 —4 —3 —6 —15 —23 —28 —34
8 8
—14 —10 —5 —4 —11 —16 —21 —32 —11 —8 —5 —3 —11 —16 —20 —30
—15 —7 —4 —6 —14 —22 —29 34 —12 —4 —3 —6 —15 —22 —28 —34
16 16
—8 —9 —6 —5 —9 —14 —19 —27 —5 —7 —5 —5 —10 —14 —18 —26
—7 —6 —7 —12 —15 —22 —25 —4 —5 —6 —12 —14 —21 —24
24 36 24 36
—6 —7 —7 —7 —12 —13 —18 —24 — —2 —4 —6 —6 —11 —12 —18 —23

5K11837 04/03/99
JMAEROFOIL
Fan Code: 1 25JM/50/1 0/12/... WOODSI AIR MOVEMENT

1250 mm 575 rev/mm 12 Blades 50 Hz


BS575OPI1
EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
I I I I I mm in
I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000
1.2
30

25 1.0

a 20 -0.8
0
9)

a 15 -0.6
0
I

a
U

0.
10- -04

5 .Q

uloytmInT
TAD COATTOI
nIToclatlon
ATIflTTTICflflI. Inc.
0- -0.0
0 5 10 15 20 25
6
5

I
4
3
2
-6°___
0 5 10 15 20 25
q, — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle • - • • Angle 7
—15 —6 —5 —6 —11 —19 —25 —35 —13 —3 —5 —7 —11 —16 —23 —32
8 8
—14 —4 —7 —6 —11 —17 —22 —31 —11 —1 —6 —8 —11 —14 —19 —29
—14 —5 —6 —5 —11 —19 —25 —11 —3 —5 —5 —11 —17 —22 —30
16 16
—13 —3 —9 —8 —12 —16 —21 —29 —10 1 —9 —8 —12 —15 —18 —27
—4 —7 —7 —12 —15 —19 —23 —7 —21 —7 —7 —12 —13 —16 —21
24 36 24 36
—9 —4 —8 —8 —12 —15 —19 —24 — —6 —1 —8 —8 —12 —13 —17 —22

SK11840 04/03/99
JM AEROFOIL
Fan Code: 1 25J M14018161... wooisi
* I MR MOVEMENT
C.
ISO 9001
1250 mm 720 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
I I — I mm
wg
in
wg
/hr
3
m 0 20000 40000 60000 80000
1.4

1.2
30

25 1.0

i:i
a)
D
(
0
0 20 0.8
8)
II.
Ca
0
I—
15 0.6
Ca
U

10 P0.4

5 0.2

rnn
movmEIlr
flflo COATIIOL
TCOCffiTIOT
TTETTTTIOflTL. Inc.
0 •0.0

6
a)
0
5
4
C
0

a) 3
.0
0 2
0
.0

0
0 5 10 15 20 25
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •
2k Angle E E • -E E
—15 —6 —3 —7 —15 —21 —26 —31 —12 —5 —4 —7 —14 —21 —26 —30
8 8
—14 —11 —5 —4 —9 —15 —19 —28 —12 —10 —5 —4 —8 —15 —19 —27
—11 —9 —6 —4 —9 —15 —22 —26 —9 —8 —5 —4 —9 —15 —22 —25
16 16
—7 —5 —8 —8 —10 —13 —16 —24 —5 —3 —8 —8 —10 —13 —17 —23
—7 —7 —5 —12 —16 —19 —21 —6 —5 —7 —5 —12 —15 —19 —20
24 32 24 32
—6 —4 —8 —9 —12 —15 —17 —21 — —4 —3 —9 —9 —12 —14 —17 —20

5K11821 04/03/99
JMAEROFOIL ‘

Fan Code: 1 25JM/40/8/9/... I


wooDsI AIR MOVEMENT
c
1250 mm 720 rev/mm 9 Blades 50 Hz
EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

!min
3
ft 0 10000 20000 30000 40000 50000 60000
mm in
wg wg
/hr
3
m 0 20000 40000 60000 80000 100000

40
1.5

30
Oj
1.0

20

• 0.5

10-

0- 0.0
0 5 10 15 20 25 30

a)
0
0
8)
.0
0
(I)
.0

q, — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frenuency (Hz) Pitch Octave Band Centre FreQuency (Hz)
Angle Angle .

—18 —8 —5 —4 —12 —20 —27 —16 —6 —5 —3 —13 —20 —26 —32


8 8
—23 —10 —9 —2 —9 —15 —19 —29 —19 —7 —9 —2 —9 —15 —18 —28
—19 —8 —5 —4 —11 —19 —27 —32 —14 —5 —4 —5 —13 —20 —26 —32
16 16
—15 —7 —8 —4 —8 —12 —17 —25 —11 —3 —7 —4 —9 —13 —16 —23
—9 —6 —6 —7 —12 —14 —20 —24 —6 —3 —5 —5 —11 —13 —19 —23
24 36 24 36
—8 —5 —7 —7 —11 —13 —16 —23 — —5 —2 —6 —6 —10 —12 —15 —22

5K11822 04/03/99
JMAEROFOIL
Fan Code: 125JM/50/8/12/...
©

1250 mm 720 rev/mm 12 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
mm in
I— wg wg
/hr
3
m 0 20000 40000 60000 80000 100000

40
15

(U 30
0
a)
D
C.
ci)
ci)
a) 1.0
0
(U
C

20
(U
U

C.

0.5

10-

0- -0.0

a)
0
C
U..
0
a)
.0
0
0
.0

U- 0 5 10 15 20 25 30
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle 1k E - 8k
—19 —6 —8 —4 —9 —17 —23 —32 —16 —4 —7 —5 —8 —14 —20 —30
8 8
—17 —4 —8 —5 —10 —15 —20 —29 —14 —2 —7 —7 —10 —13 —17 —27
—16 —7 —6 —5 —8 —16 —23 —30 —14 —4 —6 —5 —8 —15 —20 —28
16
—14 —3 —10 —8 —11 —15 —20 —27
16
—11 1 —9 —8 —11 —13 —17 —25 (-
24 36
s —7 —7 —11 —14 —18 —22
24 36
—7 —7 —11 —12 —15 —20
—9 —4 —9 —8 —11 —14 —18 —23 — —7 —2 —8 —8 —11 —12 —15 —21

SK11825 04/03/99
JM AEROFOIL
(-m , Fan Code: 1 25J M14016161... wools AIR MOVEMENT

1250 mm 960 rev/mm 6 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft

/hr
3
m
0

0
I
I
10000
I

20000
I
20000
I

40000
I
30000
I

60000
40000
— 50000

80000
60000

100000
70000

120000
I mm
wg
in
wg

60

20

(15 40 -

ci) 1.5
D
‘ci
0,
a)

cci 30
0
I
C
(0 1.0
LJ

a
20

0.5
10-

1(10 COATOOL
IITOCIATICA
IILTERICTTIO(1(1I. lAC.
0- -0.0

0
0

0
a)
.0
0
CO
.0

0 5 10 15 20 25 30 35
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle .

—14 —8 —5 -8 —12 —20 —24 —29 —11 —6 —4 —5 —11 —19 —24 —28
8 8
—12 —13 —10 —3 —7 —14 —18 —25 —10 —10 —10 —3 —6 —13 —18 —24
—9 —10 —8 —5 —8 —14 —20 —26 —7 —8 —8 —4 —7 —13 —20 —24
16
—5 —6 —8 —10 —11 —14 —16 —23 —3 —5 —8 —10 —10 —13 —17 —22
—7 —8 —8 —5 —10 —15 —18 —22 —10 —15 —18 —21
24 32 24 32
—5 —6 —8 —10 —12 —16 —18 —21 — —3 —4 —9 —10 —12 —15 —18 —20

5K11826 04/03/99
JM AEROFOIL
WOODS
Fan Code: 1 25J M14016191... I C AIR MOVEMENT

1250 mm 960 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations typeD Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000
I I I I I mm In
I I I I I I wg wg
fhr
3
m 0 20000 40000 60000 80000 100000 120000
80
- 3.0

70

- 2.5
60

0
ci)
-2.0 C.
(I)
cc)
‘I)
0
cc) 40
0 • 1.5
I
C
LL
30-
0.
-1.0

20

0.5
10

0 0.0

25
5) 20
(
0
0 15
0
U)
.0 10
0
cc)
.0 5
0

q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle E E E
—22 —13 —6 —3 —9 —17 —25 31 —20 —9 —5 —2 —9 —17 —23 —30
8
—20 —13 —10 —3 —6 —13 —17 —25 —15 —10 —10 —3 —6 —12 —16 —23
—20 —15 —6 —4 —8 —16 —24 —30 —16 —12 —4 —4 —9 —17 —23 —29
16 16
—17 —7 —8 —6 —7 —11 —15 —22 —12 —5 —7 —5 —8 —11 —14 —21

—8 —7 —6 —7 —9 —13 —17 —24 —4 —5 —6 —8 —13 —17 —23


24 36 24 36
—8 —6 —7 —8 —9 —13 —15 —21 — —4 —3 —5 —7 —9 —12 —14 —20

5K11827 04/03/99
JMAEROFOIL
Es’ WOOImICA%
Fan Code: 1 25JM/50/6/1 2/... AIR MOVEMENT

1250 mm 960 rev/mm 12 Blades 50 Hz


EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000
I I I C I mm in
I I I I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000

80
30

70-

2.5
60

115

a 50 2.0
D
CO
Cl)
a
a
Cl) 40
0
I—
1.5
C
Cl)
w
30•

- 1.0

20

0.5
10

0 •0.0
0 5 10 15 20 25 30 35
30
a 25
0
0 20
0
11) 15
.0
0 10
CO
.0 5
0
0 0 5 10 15 20 25 30 35
q. — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 4k Angle E E - 1k
—20 —11 —7 —4 —7 —14 —20 —28 —15 —9 —5 —6 —7 —12 —17 —26
8 8
—17 —9 —5 —6 —8 —14 —18 —24 —13 —8 —3 —7 —7 —11 —15 —22
—14 —10 —6 —5 —6 —14 —21 —28 —11 —9 —4 —5 —6 —12 —17 —25
16 16
—12 —8 —4 —8 —9 —13 —18 —24 —9 —6 —1 —8 —9 —11 —14 —22
—9 —6 —7 —9 —14 —16 —21 —7 —4 —7 —10 —12 —13 —19
24 36 24—36
—7 —8 —5 —8 —10 —13 —16 —22 —5 —6 —3 —8 —10 —11 —13 —19

5K11830 04/03/99
JM AEROFOIL ñI
Fan Code: 125JM/40/4/6/... I AIR MOVEMENT
(-
1250 mm 1470 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000
mm in
I wg wg
/hr
3
m 0 50000 100000 150000
140

120 -

100

C
Ca

0
D
C,,
C,,
0
80
a 3
Cs
0
I
C
(a 60
LL
2

40

20

rmommT
‘..
lflD CDC,TOt
nCCocffiTIoI
IflYEflflflYIOflflI. mc.
0’ -0
0 10 20 30 40 50
50

0
0 40 C
0. 30
-o
0
-D 20
0
(0
10
I 0
0 10 20 30 40 50
q, — Volume Flow (m’/s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . 4k Angle E •E E
—11 —15 —6 —4 —7 —15 —21 —26 —10 —13 —5 —4 —7 —14 —22 —25
8 8
—9 —15 —11 —5 —5 —9 —16 —19 —8 —13 —11 —5 —5 —9 —16 —18

16
—6
—3
—12
—10
—10
—8
—7
—11
—5
—11
—10
—13
—16
—16
—22
—19
16
—4
—1
—11
—8
—9
—7
—7
—11
—5
—11
—10
—13
—17
—17
—21
—18
C
—5 —10 —8 —9 —6 —13 —17 —20 —7 —9 —6 —13 —17 —19
24 32 24 32
—3 —9 —7 —11 —12 —14 —18 —20 — —1 —7 —6 —11 —12 —14 —18 —19

SK11831 04/03/99
JM AEROFOIL
Fan Code: 1 25JM14014191... IJ
4
WOODS
1250 mm 1470 rev/mm 9 Blades 50 Hz
EN 29001
I AIRMOVEMENT1

Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000 -

mm In
I —

wg wg
/hr
3
m 0 50000 100000 150000 200000

-7

150 6

(
D
C’,
C’)
100
a

b
Cc 3
U

5Q. •2

0- •0

80
70
60
0
a 50
0
U) 40
.0 30
0
U) 20
.0
10
0
a-
q — Volume Flow (m’/s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle
E E ••
Angle -•
- 1E -. -•7E T
—22 —18 —8 —5 —4 —12 —20 —27 —20 —16 —7 —4 —4 —12 —19 —25
8 8
—17 —23 —10 —9 —2 —9 —15 —19 —14 —20 —9 —9 —3 —9 —14 —17
—24 —19 —8 —5 —4 —11 —19 —27 —20 —16 —6 —6 —6 —12 —18 —26
16 16
—18 —16 —7 —8 —5 —8 —12 —16 —14 —13 —5 —8 —6 —9 —11 —15
—7 —7 —7 —12 —14 —20 —6 —6 —5 —6 —7 —12 —14 —19
24 36 24 36
—8 —9 —6 —8 —8 —12 —13 —16 — —5 —6 —4 —6 —7 —11 —12 —15

SK11832 04/03/99
JM AEROFOIL
WOODS’S
Fan Code: 1 25J M/50/4/6/... AIR MOVEMENT
(—
1250 mm 1470 rev/mm 6 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations typeD— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000
I I I mm in
I I I I I I ‘ wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000 140000
1400
140

1200
120

1000
100- .4
a
6)
D
C
U)
U)
6)
800 80 - .3
a
0
F

a
U
600 60 -
2

400 40 -
•1
200 20

flIID COA1POL
IIUOCIDTIOD
IIITCIIIIDTIOAIII. Inc.
0 0

a
v

40
T+ —


—J-_..zrz
—- (
0 I —
0 30 +
a
.0 2 1 —

0
U)
.0 1 EE :::Z
80
0
0 10 15 20 25 30 35 40 45
q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E Angle
—18 —11 —10 —11

-
—2 —10 —19 —24 —16 —9 —9 —11 —1 —10 —18 —23
8 8
—14 —8 —8 —8 —5 —9 —13 —15 —12 —6 —8 —8 —4 —9 —12 —13
—17 —10 —8 —6 —4 —12 —17 —23 —15 —8 —8 —6 —5 —12 —17 —23
16 16
—10 —5 —5 —10 —11 —12 —16 —19 —8 —4 —5 —9 —12 —12 —16 —19
7 6 9 —13 15 —17 —5 —7 —8 —10 —12 —13 —17
24 32 24 32
—6 —7 —7 —9 —10 —13 —15 —17 — —3 —5 —7 —9 —11 —12 —14 —17

SK11833 04/03/99
JM AEROFOIL -.‘\Ui, I

Fan Code: 125JM/50/4/9/...


woo
AIR MOVEMENT
I
ISO 9001
1250 mm 1470 rev/mm 9 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type D— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000
I I I I I mm in
i I I I wg wg
/hr
3
m 0 50000 100000 150000 200000
160-
-6

140

120

C 100

80
3

60

-2

40

-1
20
r -

movEmEnt
flAb COnTROl
noocInyloll
IflTRftflflTIOflfll Inc.
0- -0

80 ---

70 —
-
60
50 —

40
z
—•-------

— —-
30
24°
EE-;;;—---
-

20 —
10
0
0 10 20 30 40 50 60
— Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E E EE E •7 T •E E
—20 —14 —10 —6 —3 —10 —16 —23 —18

-
8 —13 —9 —6 —3 —8 —15 —22
8
—15 —10 —6 —10 —6 —9 —12 —15 —12 —9 —4 —9 —5 —8 —12 —14
—17 —12 —6 —4 —6 —12 —18 —25 —14 —11 —4 —4 —6 —12 —17 —24
16 16
—13 —9 —3 —10 —9 —12 —14 —17 —10 —8 —I —9 —9 —11 —13 —16
—8 —9 —6 —9 —9 —13 —17 —20 —4 —9 —12 —16 —19
24 36 24 36

—10 —8 —3 —10 —11 —13 —17 —20 — —6 —7 —1 —8 —10 —12 —15 —19

SK11834 04/03/99
JMAEROFOIL
Fan Code: 1 25JM/50/4/1 2/..
woo C AIR MOVEMENT

1250 mm 1470 rev/mm 12 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype D— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000
mm in
wg wg
/hr
3
m 50000 100000 150000 200000
2000 -8
200

1500 6
150

a
0
a
D
.5 C
0,
a
0
1000 100-
a
I
C
a
U
3
a-

500 50 2

nfl
rflOvImEflr
111000000011
1111110011111100
IflTCRflflhl01111I. Inc.
0 0

9)
0
C-
0
a
.0
a
(I)
.0

0 0 10 20 30 40 50 60
q — Volume Flow (m’/s)
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

In let Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 4k Angle E 125 E E E E
—18 —19 —7 —8 —4 —8 —16 —23 —15 —18 —5 —8 —4 —6 —13 —20
8 8
—16 —17 —4 —8 —5 —10 —15 —19 —13 —16 —3 —8 —5 —8 —12 —17
—12 —16 —7 —6 —5 —8 —16 —23 —9 —15 —5 —6 —5 —7 —13 —21
16 16
—10 —14 —3 —10 —8 —11 —15 —20 —8 —12 —1 —9 —8 —9 —12 —17
—6 —10 —7 —8 —8 —12 —15 —19 —4 —8 —5 —8 —9 —10 —12 —16
24 36 24 36
—7 —10 —5 —9 —9 —11 —15 —18 — —5 —8 —3 —9 —10 —9 —12 —16

SK11835 04/03/99
JMAEROFOIL
ES WOODS’
c Fan Code: 1 4OJM/40/1 2/6/... AIR M0VEMENT

EN 29001 1400 mm 480 rev/rn in 6 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
I wg wg
m
/
3 hr 0 20000 40000 60000 80000

• 0.7

-0.6
15

0.5

10 0.4

0.3

5. -0.2

• 0.1

0’ -0.0
0 5 10 15 20 25
3.5
3.C
2.5 —

2.0 32°
-
1.5
24°
1.0
0.5 ———-

0.0
0 5 10 15 20 25
q — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k Angle E E E E •E r
—13 —11 —3 —6 —11 —13 —26 —32 —11 —9 —3 —s —10 —11 —25 —30
8 8
—10 —12 —8 —5 —7 —8 —23 —30 —8 —10 —7 —5 —7 —7 —22 —29
—10 —10 —3 —7 —13 —17 —22 —26 —9 —g —2 —7 —12 —17 —20 —25
16 16
—5 —8 —8 —ii —9 —8 —20 —24 —3 —6 —8 —11 —8 —8 —19 —23

24 36
—5
—8
—7
—7
—7
—8
—10
—13
—13
—15
—14
—17
—16
—19
—18
24

36
—3
—3
—7
—6
—6
—5
—7
—8
—12
—13 - —14
—13
—15
—14
—17
—16

SK11852 04/03/99
JMAEROFOIL I
I
Fan Code: 1 4OJM/40/1 2/9/... WOODSI C.
BSI

© 1400 mm 480 rev/rn in 9 Blades 50 Hz


BS575OPt1
EN 29001
Iso 9001
AIR MOVEMENT

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000
mm in
I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000
-1.0
25

20 -0.8

Cs
0
0)
15 0.6
C
C/C
Co
a)
0
CO
0
I—

Cs
U 0.4

cC-

5- 0.2

/
0CC
C000lmErCr
CAD COflYDOL
flU0CITIOA
IflTEflflflTCOAflC, ICC.
0- -0.0
0 5 10 15 20 25

2)
0
C
0
0
a)
.0
0
CO
.0

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle -. 7 -jiE -

—14 —11 —4 —5 —10 —14 —25 —31 —11 —9 —3 —3 —9 —12 —25 —30
8 8
—13 —13 —8 —6 —5 —7 —22 —28 —10 —11 —8 —5 —4 —5 —21 —27
—8 —10 —6 —7 —9 —10 —17 —20 —5 —8 —5 —7 —7 —10 —15 —19
16 16
—9 —11 —9 —8 —5 —7 —19 —24 —5 —9 —8 —8 —4 —6 —19 —22 (S.

—9 —7 —8 —11 —14 —14 —15 —1 6 7 —11 —13 —13 —14


24 36 24 36
—5 —8 —7 —8 —10 —14 —17 —19 — —1 —5 —4 —7 —9 —13 —15 —17

SK11853 04/03/99
JMAEROFOIL
Fan Code: 1 4OJM/40/1 0/6/...
j WOODS
( AIR MOVEMENT

EN 29001
Iso 9001
1400 mm 575 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
I I I I I mm in
I I I I I I -- wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
10
25

20 0.8

(U

U)
D 15 -0.6
0
(I)
U)
0
(U
0
I—
C
(U
U -0.4

5-0.2

flAb COnTROL
A000IATIOA
ATRILAATIOTflI. mc.
0- •0.0
30
6
C 5
4 —
----


--

32
3
2 24°

0
U 10 15 20 25 30
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle E E E E E E
—17 —12 —5 —4 —9 —11 —22 —29 —14 —10 —4 —4 —9 —10 —22 —28
8 8
—15 —10 —9 —5 —7 —7 —19 —28 —12 —8 —8 —4 —6 —5 —18 —27
—13 —10 —4 —4 —11 —16 —21 —24 —11 —9 —4 —4 —11 —16 —19 —23
16 16
—8 —6 —8 —10 —9 —8 —17 —23 —5 —4 —7 —10 —9 —7 —16 —22
—8 —5 —7 —8 —12 —15 —16 —18 —6 —4 —6 —6 —11 —13 —15 —16
24 36 24 36
—7 —5 —7 —8 —12 —14 —16 —17 — —4 —4 —5 —7 —12 —13 —14 —16

5K11854 04/03/99
JMAEROFOIL
Fan Code: 1 40J M/40/1 0/9/...
Iso 9001
1400 mm 575 rev/mm 9 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
mm in
F I
I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
1.4
35

1.2
30

25 1.0

a
0
a C
a
(I) 20 0.8
a

a
0
I—
15 -0.6
a
U

10• -0.4

5. -0.2
V
VfllAT
iflO COTRO
rijoclanon
flTiflflTI0nht. Inc.
0• •0.0
0 5 10 15 20 25 30
8
a
0
7
6
(
cI 5
0 4
a
.0 3
0
a 2
.0

q., — Volume Flow (m


/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 4k Angle E E E E E E E
—15 —12 —6 —4 —9 —12 —23 —28 —12 —10 —5 —2 —8 —11 —24 —28
8 8
—14 —15 —9 —6 —6 —5 —18 —26 —11 —12 —9 —5 —5 —3 —18 —25
—8 —12 —6 —6 —9 —9 —16 —19 —5 —10 —6 —6 —7 —8 —14 —16
16
—9 —13 —9 —8 —7 —5 —17 —22
16
—6 —10 —7 —8 —5 —5 —17 —20 (-
24 36
—6
—6
—10
—9
—7
—6
—7
—8
—10
—10
—14
—13
—14
—16
—14
—17
24
— 36
—1
—1
7
—6 —4 —7 —8 —12
—13
—14
—13
—16

SK11 855 04/03/99


JMAEROFOIL I

Fan Code: 1 4OJM/50/1 0/12/... WOODS AIR MOVEMENT

1400 mm 575 rev/mm 12 Blades 50 Hz


BS575OPt1
EN 29001
SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000
I I I I I I mm in
I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000
1.4
Iso 5801
lvi -

Type C+2D - - - -

Air Density 1.2 kg/rn


3 - —

1.2
30

25 -1.0

(Th

20

5. -0.6

10- 0.4

5 02

flOvemlon
510 000nIlol
SI1OCIATIOA
IflI1IrnflTIOIIIlI. Inc.

0 •0.0

9
8
7
6
5
4
3
2

q. — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle 1k 4k

—13 —8 —5 —5 —11 —16 —27 —32 —5 —5 —4 —10 —14 —25 —30


8 8
—15 —12 —8 —4 —7 —8 —20 —26 —13 —10 —8 —4 —6 —6 —18 —24
—16 —10 —3 —5 —12 —19 —26 —29 —12 —7 —2 —5 —11 —19 —24 —28
16 16
—12 —6 —9 —7 —8 —8 —18 —22 —8 —3 —9 —8 —7 —6 —15 —19
—7 —6 —8 —7 —11 —15 —16 —16 —4 —2 —7 —6 —10 —14 —14 —15
24 36 24—36
—8 —5 —8 —8 —10 —12 —18 —20 —4 0 —6 —7 —9 —12 —17 —19

SK11857 04/03/99
JM AEROFOIL
Fan Code: 140JM14018161...
WOODS
AIR MOVEMENT
(
ss57op
iSO 9001
1400 mm 720 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000
I I rririi in
I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
400 1.6
40

1.4

30 1.2

(0

a 25 -1.0
D
U)
U)
0)
0
(0 20 -0.8
0
F

(0
U
‘0.6
0.

10. -0.4

5- 0.2

0- -0.0
0 5 10 15 20 25 30 35
12
a
0
10 C
0., 8 —+— .—_---

—.- 32
0 6
a)
.0 240
0 4
C,,
.0 2 E 10
0 -.
0 0 10 15 20 25 30 35
q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle .. ‘ 4k Angle E E E E 8k
—19 —13 —8 —3 —8 —11 —17 —27 —15 —11 —7 —3 —7 —9 —16 —26
8
—17 —11 —11 —6 —6 —6 —13 —25 —13 —9 —10 —5 —6 —5 —11 —24
—15 —10 —7 —3 —9 —14 —20 —23 —12 —8 —7 —3 —9 —14 —18 —22
16
—9 —6 —8 —9 —10 —8 —13 —21
16
—6 —4 —8 —9 —10 —7 —12 —21 C
—7 —7 —11 —14 —16 —17 —6 —4 —7 —6 —10 —13 —14 —16
24 36 24 36
—7 —5 —7 —8 —12 —14 —15 —17 — —4 —4 —6 —6 —12 —13 —13 —16

SK11841 04/03/99
JM AEROFOIL
Fan Code: 1 40J M14018191. woo . a AIR MOVEMENT
I
1400 mm 720 rev/mm 9 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000 80000
I I I I I I I mm in
, I I I I I wg wg
/hr
3
n1 0 20000 40000 60000 80000 100000 120000
2.0
50

40
1.5

cc
a

300
30

P1.0

U 200 20-
Q.

0.5

10

r
rnovImERr
mD COTROI
flUOCITIOfl
IflYERhIflTIOflflI Inc.
0 0.0

16
14
12
10
8
6
4
2
0
5 10 15 20 25 30 35 40
q — Volume Flow (m
/s)
3

Sound Data B5848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle E E EE E 7E E 8k
—17 —13 —8 —3 —7 —11 —19 —27 —14 —11 —8 —2 —6 —10 —19 —26
8 8
—18 —13 —11 —7 —7 —4 —12 —24 —15 —10 —11 —5 —5 —3 —12 —23
—8 —10 —9 —6 —8 —9 —14 —18 ‘ —8 —8 —6 —7 —8 —12 —17
16 16
—12 —10 —10 —8 —8 —5 —12 —20 —8 —7 —8 —8 —7 —4 —12 —18
—7 —7 —8 —7 —9 —13 —15 —14 —3 —6 —7 —9 —12 —13 —13
24 36 24 36
—7 —7 —7 —7 —9 —12 —15 —17 — —3 —3 —5 —6 —8 —11 —13 —16

5K11842 04/03/99
JMAEROFOIL
Fan Code: 1 4OJM/50/8/1 2/... WOODS C AIR MOVEMENT

1400 mm 720 rev/mm 12 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

ft’/min 0 10000 20000 30000 40000 50000 60000 70000 80000


mm in
T wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
60

-2.0
50

(0 40•
6) -1.5
D
C’,
ci)

CO 30-
0
I

(0 1.0
U

0
20 -

• 0.5
10-

0- 0.0
0 5 10 15 20 25 30 35 40
18

0
a
16
14 (.
0
12
0 10 —.-- ;i
ci) -
.0
8
0
C,) 4
— 24°
.0

n
0 5 10 15 20 25 30 35 40
q. — Volume Flow (m
!s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k Angle •E E EE •E E 4k
—16 —8 —8 —4 —8 —14 —23 —30 —14 —5 —8 —3 —7 —12 —21 —28
8
—18 —12 —10 —5 —6 —7 —14 —24 —15 —9 —10 —4 —5 —5 —12 —22
—16 —12 —5 —4 —9 —17 —25 —28 —13 —9 —4 —4 —9 —16 —22 —26
16 16
—11 —5 —11 —8 —8 —7 —14 —21 —8 —2 —10 —8 —8 —6 —11 —18
—6 —6 —10 —8 —10 —14 —17 —16 —3 —2 —8 —7 —9 —14 —15 —15
24 36 24—36
—7 —5 —9 —8 —10 —12 —17 —20 —3 —1 —7 —7 —9 —11 —16 —19

SK11844 04/03/99
JM AEROFOIL
Fan Code: 1 40J M14016161... woo MOVEMENT
I
1400 mm 960 rev/mm 6 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000
mm in
wg wg
m
/
3 hr 0 20000 40000 60000 80000 100000 120000 140000
700
70

• 2.5
600
60-

500 2.0
50-
I—..’

ci,

(‘I 400
ci) 40
15
(6
0
I—
C 300
cc
30
LL

•1.0

200 20

0.5
100 10

movLmcnr
HID CORTROL
nuocrnrlon
IflT(flflflTlOflfll. Inc.

0 0.0

ci
0 5 10 15 20 25 30 35 40 45
q, — Volume Flow (m
Is)
3
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle
—15
J —14 —12 —4
.

—6 —11
4k

—13 —26
Angle
—12 —11 —11
EE E
—3 —5
2k

—9 —12 —24
8 8
—12 —11 —12 —8 —6 —7 —8 —23 —9 —9 —11 —7 —5 —6 —7 —22
—12

-
—10 —11 —4 —7 —13 —18 —23 —10 —9 —10 —3 —7 —13 —16 —21
16 16
—6 —7 —9 —10 —12 —10 —10 —22 —2 —5 —9 —10 —12 —10 —9 —21
—5 —9 —8 —10 —14 —16 —18 —4 —4 —8 —7 —9 —12 —14 —16
24—36 24—36
—5 —7 —9 —8 —11 —14 —16 —18 —1 —5 —7 —7 —11 —13 —14 —17

SK11845 04/03/99
JM AEROFOIL cI—I
Fan Code: 140JM/40/6/9/... C AIR MOVEMENT

1400 mm 960 rev/mm 9 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

fmin
3
ft 0 20000 40000 60000 80000 100000
mm in
_ I I I wg wg
/hr
3
m 0 50000 100000 150000

3.5

80
3.0

2.5
a 60
a
a) C
Ca
a) 2.0
a-
a
0
I—
40•
C
a 1.5
LI

-1.0

20

• 0.5

nip
movililiAr
PAD COPTROI
AAAOCIDTIOP
IIITEI1AATIOAAI. Inc.
0-0.0
10 20 30 40 50
35
6) 30
0 25
a
20
8) 15
.0
0
Co
10
.0
5
0
a
— Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 7 • Angle E E •7
—15 —12 —4 —5 —11 —14 —26 —15 —12 —10 —2 —4 —9 —14 —25
—19 8
—18 —13 —14 —9 —7 —6 —7 —22 —15 —10 —13 —7 —5 —4 —6 —20

16
—12
—9
—9
—11
—11
—7
—10
—8
—9
—10
—6
—11
—7
—18
—20
16
—4
—8
—6
—6
—10
—10
—7
—9
—7
—8
—9
—5
—9
—7
—17
—17
C
-6 —6 —10 —8 —9 —12 —15 —15 —2 —3 —8 —7 —8 —11 —14 —14
24 36 24 36
—7 —6 —9 —8 —9 —11 —14 —18 — —3 —3 —6 —7 —8 —11 —12 —16

SK11 846 04/03/99


JM AEROFOIL
Fan Code: 14OJM/50/6/9/... WOODS AIR MOVEMENT

1400 mm 960 rev/mm 9 Blades 50 Hz


Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000
mm in
I I wg wg
/hr
3
m 0 50000 100000 150000

3.5

80
3.0

2.5
60

D
‘9
(I)
9) - 2.0

(9
0
I—
40
(9 -1.5
U

•1.0

20

• 0.5

Rr
(AD COATDO(
AffOCIATIOA
N
IAT(RAATPOF(RI. IAC.

0 •0.0
0 10 20 30 40 50
35
C) 30
25
20
15
10
5
0
0 10 20 30 40 50
q — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E EE -. E
—15 —10 —9 —4 —6 —12 —15 —27 —12 —8 —8 —3 —5 —11 —15 —25
8 8
—12 —11 —11 —6 —6 —8 —11 —24 —9 —8 —10 - —5 —5 —7 —9 —22
—12 —12 —9 —3 —8 —13 —18 —24 —9 —7 —3 —6 —12 —16 —23
16 16
—7 —8 —8 —9 —9 —9 —11 —20 —5 —5 —6 —7 —8 —7 —10 —19
—6 —5 —9 —9 —11 —14 —16 —18 —4 —2 —8 —7 —10 —13 —15 —17
24 36 24 36
—5 —5 —9 —10 —13 —14 —16 —19 — —3 —2 —7 —8 —11 —13 —14 —18

SK11847 04/03/99
JMAEROFOIL I frI

Fan Code: 1 4OJM/50/6/1 2/...


WOODS AIR MOVEMENT
C
1400 mm 960 rev/rn in 12 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installations type C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000
I I I I I mm in
_
wg wg
/hr
3
m 0 50000 100000 150000
-4.0
100

3-5

80
3.0

a
Ii
a
60
2.5 C
(1)
U)
a)
a-
a 2.0
0
b
C
a
LI. 40
0

-1.0

20

0.5

0- -0.0
0 10 20 30 40 50
40
a)
0
35
30
0
a 25
0
a) 20
.0 15
0
C’) 10
.0
5
0
0 10 20 30 40 50
— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle • —
4k

—17 —11 —9 —4 —6 —13 —18 29 —15 —9 —7 —3 —5 —10 —16 —27


8 8
—19 —14 —12 —6 —5 —7 —9 —22 —16 —13 —10 —6 —4 —5 —7 —20

—16 —15 —9 —3 —7 —14 —21 —27 —12 —13 —7 —3 —6 —13 —19 —26
16 16
—10 —11 —7 —9 —8 —8 —9 —20 —7 —9 —4 —9 —8 —6 —6 —17

—5 —8 —8 —9 —9 —13 —16 —17 —2 —5 —6 —8 —8 -13 —15 —16


24 36 24 36
—7 —9 —7 —8 —9 —11 —14 —20 — —2 —5 —4 —7 —8 —11 —13 —19

5K11848 04/03/99
JM AEROFOIL
Fan Code: 14OJM/50/4/9/... woDs
I AIR MOVEMENT

1400 mm 1470 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000 140000
mm in
I I• wg wg
/hr
3
m 0 50000 100000 150000 200000
-B
200

-7

150 -
6

/
a..
a) .5
D
U)
a)

1000
100- .4
0
I
C
(0
U
3
a

50- 2

(In
nbo,tIncnr
(no COATOOL
nrloCIAnIoA
IflTERflfltIOflflI, InC.

0- -0
0 10 20 30 40 50 60 70

0 10 20 30 40 50 60 70
q, — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle ..
Angle E E E 8k
—14 —16 —10 —7 —4 —8 —12 —20 —11 —14 —8 —6 —3 —7 —12 —18
8 8
—10 —15 —10 —10 —5 —7 —8 —15 —7 —11 —8 —9 —5 —6 —7 —13
—11 —14 —10 —5 —5 —9 —14 —21 —8 —13 —8 —5 —4 —8 —13 —20
16 16
—6 —10 —7 —10 —9 —10 —9 —15 —3 —7 —4 —8 —9 —8 —8 —14
—6 —9 —6 —9 —10 —13 —15 —17 —3 —6 —4 —8 —9 —12 —14 —16
24 36 24 36
—5 —8 —6 —10 —11 —14 —15 —18 — —2 —7 —3 —9 —10 —13 —14 —16

SK11849 04/03/99
JMAEROFOIL
BSI WOODS’
©
BS575OPt1
EN 29001
ISO 9001
Fan Code: 1 4OJM/50/4/1 2/ I

1400 mm 1470 rev/mm 12 Blades 50 Hz


... AIR MOVEMENT

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/rnin
3
ft 0 20000 40000 60000 80000 100000 120000 140000 160000
I I I mm in
I I I I wg wg
/hr
3
m 0 50000 100000 150000 200000 250000
250

200- 8

a
0
a)
150- ‘6
C
C’,
Cl)
‘0
ci
CS
0

C
CS
U 100 4

a-

50 2

gNCflD OOATIlO’%.
CISOCIATIOfl
TIRflflTIOflAI. ICC.
0’ 0

a)
a
C
6)
0
C’,
£3

0
0 0 10 20 30 40 50 60 70 80
q, — Volume Flow (m
/s)
3
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall Ievel.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle -.
1k 4k Angle •E E 4k 8k

—20 —16 —8 —9 —3 —8 —14 —22 —18 —14 —6 —8 —3 —5 —13 —21


8 8
—21 —18 —12 —10 —5 —6 —7 —14 —19 —17 —10 —9 —3 —4 —5 —12

16
—18
—12
—16
—11
—12
—6
—5
—11
—4
—8
—9
—8
—16
—7
—25
—14
16
—15
—8
—14
—9
—11
—3
—4
—10
—3
—8
—8
—7
—14
—4
—23
—ii
C
—7 —6 —7 —10 —9 —11 —15 —17 —3 —5 —9 —8 —11 —14 —17
24 36 24 36
—8 —8 —6 —10 —9 —10 —12 —17 — —5 —4 —3 —9 —8 —10 —11 —16

SK11850 04/03/99
JMAEROFOIL I

Fan Code: 1 6OJM/40/1 2/6/...


WOODSJ
AIR MOVEMENT

5S5750Pt1
EN 29001
Iso 9001
1600 mm 480 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000
I I I I I I mm in
I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
-0.8
20-

0.7

15 06

C 0.5

10- 0

0.3

5 0.2

0.1

0 0.0
0 5 10 15 20 25 30 35
°
ci)
4
T — 32°

0
3 —
0
ci) — —
2

0
Cl)
.0 - -

------v
0
0 0 5 10 15 20 25 30 35
q, — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle
— •. -.
Angle
—14 —8 —3 —6 —13 —16 —23 —29 —12 —6 —2 —6 —12 —14 —22 —28
8 8
—13 —13 —8 —4 —7 —9 —19 —27 —10 —11 —7 —3 —7 —7 —18 —26
—14 —12 —5 —5 —9 —12 —15 —19 —12 —11 —4 —5 —8 —12 —13 —18
16 16
—8 —9 —8 —7 —8 —9 —13 —17 —5 —8 —7 —7 —8 —8 —12 —16
—9 —6 —5 —9 —13 —17 —18 —21 —7 —6 —5 —7 —12 —15 —16 —20
24 32 24 32
—7 —8 —7 —8 —9 —12 —12 —14 — —4 —7 —6 —6 —9 —11 —10 —13

SK11867 04/03/99
JM AEROFOIL
woos’
Fan Code: 1 60JM14011 2/9/... AIR MOVEMENT
C
1600 mm 480 rev/mm 9 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000 80000
I I I I I I I I mm in
I I I wg wg
m’/hr 0 20000 40000 60000 80000 100000 120000
1.2
30

1.0
25

cc 20 0.8
0
cc,
D
c)
a)
0
cc 15 -0.6
0
I—

cc
U

0
lo. 0.4

5 02

IAr
AAD CôAIlOI
fluocrnflon I
IfltEflflflTIOflflI. Inc’
I-
0- 0.0

0
a 7
6
C
0 5
6) 4
.0 3
0
cc, 2
.0

0
0 15 20
— Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle E ‘E E E
—17 —10 —2 —6 —14 —17 —26 —32 —14 —7 —2 —5 —13 —15 —26 —32
8 8
—13 —14 —7 —4 —7 —8 —19 —28 —10 —12 —7 —3 —6 —7 —19 —27

—16 —10 —3 —7 —12 —16 —21 —25 —13 —8 —2 —7 —11 —15 —19 —24
16 16
—6 —11 —10 —9 —8 —7 —15 —20 —2 —9 —9 —9 —7 —6 —15 —18

9 —10 —7 —7 —8 —11 —11 —14 5 6 —7 —10 —10 —13


24 36 24 36
—6 —8 —8 —8 —9 —11 —12 —14 — —2 —5 —6 —7 —7 —10 —10 —13

SK11868 04/03/99
JM AEROFOIL
Fan Code: 1 6OJM/50/1 2/12/... ‘wooDs’.j AIR MOVEMENT’

1600 mm 480 rev/mm 12 Blades 50 Hz


EN 29001
50 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0
I
10000 20000 30000
———-------
40000 50000 60000
-— 70000
I
80000
I mm
wg
in
wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
1.4
35.

1.2
30-

25 -
1.0

(
0
0 20 0.8
a..

0
b
C 15 0.6
a
U

10- 0.4

5 0.2

MO COflTRO
flJlOCOTIOfl
IflftRhIflTIOflflI. IflC
0 0- -0.0
0 5 10 15 20 25 30 35 40

o 6
a
D
6) 4
.0
3
C
.0 2
< 1
0
0 5 10 15 20 25 30 35 40
q — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall Ievel.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E Angle E •E
—14 —7 —3 —8 —15 —16 —27 —33 —12 —6 —2 —7 —14 —14 —25 —32
8 8
—17 —13 —6 —4 —8 —9 —22 —31 —15 —11 —7 —4 —6 —7 —20 —29
—17 —12 —4 —5 —9 —12 —20 —26 —14 —10 —3 —5 —6 —12 —18 —24
16 16
—14 —9 —10 —7 —7 —5 —16 —21 —10 —6 —9 —7 —6 —4 —13 —18
8 —6 —7 —9 —13 —14 —17 —8 —4 —4 —6 —8 —12 —13 —16
24 36 24 36
—9 —7 —7 —7 —8 —10 —14 —16 — —5 —3 —6 —6 —7 —10 —12 —15

SK11870 04/03/99
JM AEROFOIL
1
WOODS’
Fan Code: 1 6OJM/40/1 0/6/... C AIR MOVEMENT

1600 mm 575 revlmin 6 Blades 50 Hz


SO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installations type C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 10000 20000 30000 40000 50000 60000 70000 80000
I I I I I I I I I mm in
I I I I I I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000
1.2
30-

1.0
25

cc 0.8
0
ci)
D
20
C:
cc,
cc,
ci)

CS 15 -
0.6
0
F—

cci
IL.

a. 0.4
10

5 0.2

CI,,

flOATROL
CIToGIAnOT
•jTITTTTiOflflL. Inc

0 0.0

a)
0
o
7
h
C
ci)
.0
0 3
cc,
.0

ci
5 10 15 20 25 30 35 40
q. — Volume Flow (m’/s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E •7 8k Angle E E 1k

—17 —9 —4 —6 —11 —15 —21 —27 —14 —7 —3 —5 —10 —14 —20 —26
8 8
—15 —13 —9 —4 —6 —8 —15 —25 —12 —11 —8 —4 —6 —7 —14 —24

—15 —12 —6 —4 —8 —12 —14 —18 —12 —11 —6 —4 —7 —11 —12 —17
16 16
—10 —9 —9 —7 —8 —8 —12 —16 —7 —7 —8 —7 —7 —8 —11 —15

—6 —5 —8 —11 —16 —18 —20 9 —6 —5 —7 —11 —15 —16 —19


24 32 24 32
—8 —7 —8 —8 —9 —12 —12 —14 — —6 —6 —6 —6 —9 —11 —10 —12

SK11871 04/03/99
JMAEROFOIL I
c Fan Code: 1 6OJM/40/1 0/9/... I WOODS MR MOVEMENT

1600 mm 575 rev/mm 9 Blades 50 Hz


BS575OPt1
EN 29001
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20900 40000 60000 80900
mm in
wg wg
m
/
3 hr 0 20000 40000 60000 80000 100000 120000 140000
-1.6
40

-1.4

-1.2
30

(0
0
(0 25 -1.0
D
C,)
(C
a)
0
CO 20 -0.8
0
I
C
(0
U
15 -0.6

10 -0.4

5- -0.2

00
0 0- •0.0
0 5 10 15 20 25 30 35 40 45
14
Oj 12
10 —

8 —


6 40

4
—=
2
0
0 5 10 15 20 25 30 35 40 45
q — Volume Flow 3
(m
/ s)

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •7 7 Angle E E EE E
—18 —11 —3 —5 —12 —16 —22 —30 —15 —9 —3 —4 —11 —15 —22 —29
8 8
—14 —16 —9 —4 —6 —7 —15 —26 —11 —14 —9 —3 —5 —6 —15 —25
—17 —12 —3 —5 —10 —15 —19 —23 —14 —11 —3 —5 —9 —14 —17 —23
16 16
—6 —13 —10 —9 —8 —6 —11 —18 —3 —11 —8 —9 —7 —6 —11 —16
—10 —11 —7 —7 —7 —11 —11 —13 —6 —8 —5 —6 —7 —10 —10 —12
24 36 24 36
—7 —10 —8 —8 —8 —11 —11 —14 — —2 —7 —5 —7 —7 —10 —10 —12

SK11872 04/03/99
JMAEROFOIL
. Fan Code: 1 60J M/50/1 0/12/...
ssmopti
1600 mm 575 rev/mm 12 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40900 60900 80900
mm in
I —--— I I wg wg
/hr
3
m 0 20000 40000 60000 80000 100000 120000 140000

40
1.5

a 30-
a.
a)
D
C
a) P1.0

a
0
I—
20
a
LL

0.

0.5

10-

0- -0.0
0 5 10 15 20 25 30 35 40 45

16
a) 14
12
(
0
0 10
t3 8
ci)
.0 6
0
C,) 4
.0
2
0
0 5 10 15 20 25 30 35 40 45
q — Volume Flow (m
Is)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle E ••
Angle soo E
—16 —11 —3 —6 —13 —15 —24 —31 —15 —8 —3 —5 —12 —13 —22 —29
8 8
—19 —14 —8 —4 —7 —8 —18 —28 —17 —11 —8 —3 —6 —6 —16 —26

16
—18
—15
—13
—9
—6
—11
—4
—7

—7
—7
—7

—8
—12
—5

—12
—18
—12

—14
—24
—19

—16
16
—15
—11

—8
—10
—8

—5
—5
—10

—5
—4
—8

-6
—7
—7

—7
—11
—4

—12
—16
—9

—12
—22
—17

—15
( -

—11 —8 —6
24 36 24 36
—9 —7 —8 —8 —8 —10 —13 —16 — —5 —2 —6 —7 —7 —9 —12 —15

5K11874 04/03/99
JM AEROFOIL
Fan Code: 16OJM/40/8/6/...
wooDs’s
AIR MOVEMENT

ISO 9001
1600 mm 720 rev/mm 6 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C — Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000
. mm In
I I wg wg
m’/hr 0 50000 100000 150000

40
• 1.5

(0
0 30-
ci)
(I)
Cl,
P1.0

cci
0
I—
20-
(ci
LL

a-

- 0.5

10-

vImInr
(no COnTROL
flffOCITIOT
ITTTTTTTIOAflL. Inc.
0- 0.0
0 10 20 30 40 50
18
C-I 16
— 90


14
0 12 —

10 940
) 8
-eo 6
Cl, 1L_,_
.0 —•----—-

< 2
I Q —

0 10 20 30 40 50
— Volume Flow 3
(m
/ s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle •E E E E
—19 —12 —5 —4 —9 —14 —18 —26 —16 —9 —4 —4 —8 —13 —17 —24
8
—16 —13 —11 —6 —5 —8 —11 —23 —13 —11 —10 —5 —4 —6 —10 —22
15 —13 —10 —4 —6 —10 —13 —17 13 —12 —9 —4 —6 —10 —12 —16
16 16
—10 —9 —9 —7 —8 —8 —10 —15 —7 —7 —9 —7 —7 —8 —9 —14
—13 —7 —6 —6 —10 —15 —17 —19 —10 —6 —6 —5 —9 —13 —15 —18
24 32 24 32
—9 —7 —8 —7 —8 —11 —12 —13 — —6 —6 —7 —6 —8 —10 —10 —12

SK11858 04/03/99
JM AEROFOIL 1

Fan Code: 1 60J M14018191. AIR MOVEMENT


I
1600 mm 720 rev/mm 9 Blades 50 Hz
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000
mm in
I— wg wg
/hr
3
m 0 50000 100000 150000 200000
70

2.5
60

50 2.0

(0
0
a)
D
C
0,
U)
a) 40
1.5
(0
0
I
C 30
(0
U
-1.0

20

- 0.5
10 -

vcmcnr
(AD COnTROL

IflTEflflflTIOflflI. Inc.

0- •0.0
0 10 20 30 40 50 60
30
ci) 25 —

0 20 32
-o 15
ci) —____
.0
0 10 —

U)
.0 5 - z1c--
0
0 0 10 20 30 40 50 60
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •• Angle •.
4k

—21 —14 —5 —3 —9 —15 —19 —28 —18 —12 —5 —2 —8 —14 —19 —27
8 8
—19 —14 —12 —5 —6 —7 —11 —24 —16 —10 —11 —3 —4 —6 —11 —23

—14 —14 —18 —22 —16 —12 —6 —3 —7 —13 —16 C-


-
—19 —6 —3 —8 —21
16 16
—13 —7 —10 —9 —8 —7 —8 —17 —9 —4 —9 —9 —7 —6 —8 —15

—10 —10 —9 —7 —7 —9 —11 —12 -6 —7 —7 —6 —6 —8 —10 —11


24 36 24 36
—8 —8 —8 —8 —8 —10 —11 —13 — —4 —4 —6 —7 —7 —9 —9 —12

5K11859 04/03/99
JMAEROFOIL
c
Fan Code: 1 6OJM/50/8/1 2/... I WOODS AIR MOVEMENT

1600 mm 720 rev/mm 12 Blades 50 Hz


EN 29001
ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000
mm in
wg wg
/hr
3
m 0 50000 100000 150000 200000
70 -

2.5
60-

50 2.0

j
40-
-1.5

30 -

1.0

20

0.5
10
‘p.

fl(D COTROL
flTSOCffiTIOA
flhiRflATIOfll. Inc.
0- 0.0

•0

q, — Volume Flow (m
/s)
3

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level. Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 1k 8k Angle E E E EJE
—21 —11 —6 —3 —11 —15 —20 —29 —19 —9 —6 —2 —18 —27
8 8
—21 —14 —11 —4 —6 —8 —12 —26 —19 —12 —11 —4 —4 —5 —10 —24
—18 —14 —9 —4 —6 —11 —15 —22 —15 —11 —8 —4 —5 —10 —13 —21
16 16
—14 —8 —12 —8 —7 —6 —8 —18 —11 —6 —11 —9 —7 —4 —5 —16

24 36
—:;•;;- —:;- —:- —7 —11 —13
24—36
—8 —7 —6 —5 —6 —11 —12 —14
—8 —7 —9 —8 —8 —10 —12 —15 —4 —3 —7 —7 —7 —9 —11 —14

SK11861 04/03/99
JM AEROFOIL ..\\iIf I

Fan Code: 1 60J M14016161...


woo AIR MOVEMENT
I C
1600 mm 960 rev/mm 6 Blades 50 Hz
Iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000 140000
mm in
T wg wg
/hr
3
m 0 50000 100000 150000 200000
80
3.0

70

2.5
60

(9

ci)
D
50 2.0 C
cc,
U,
ci)
a
ci) 40
a 1.5
I—

ci)
U-
30
a.
1.0

20

0.5
10

0 0.0
0 10 20 30 40 50 60 70
41]
ono
35

ci)
30
0 —
0 25
0
11)
.0
0
cc)
.0
20
15
1(1
5
- t-- ---

—-
—------.--___

0
0 0 10 20 30 40 50 60 70
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle 2k 4k Angle E E 7E E 4k

—21 —15 —8 —4 —7 —13 —16 —23 —17 —12 —7 —2 —6 —11 —15 —22
8
—19 —13 —13 —8 —4 —7 —9 —19 —15 —11 —13 —7 —4 —6 —7 —18

16
—15
—12
—14
—8
—12
—10
—5
—8
—5
—7
—9
—8
—13
—9
—16
—14
16
—13
—9
—12
—7
—12
—9
—5
—8
—5
—7
—8
—8
—10
—8
—15
—13
C
—14 —9 —7 —5 —9 —13 —17 —18 —11 —7 —6 —4 —8 —12 —15 —17
24 32 24 32
—10 —7 —9 —8 —8 —10 —13 —13 — —6 —6 —7 —6 —8 —9 —10 —11

5K11862 04/03/99
JM AEROFOIL
Fan Code: 16OJM/40/6/9/... WOODS’S
I AIR MOVEMENT

1600 mm 960 rev/mm 9 Blades 50 Hz


ISO 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not includethe effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000 140000 160000
I I I I I I I rrIrI fl
I I I I I wg wg
/hr
3
m 0 50000 100000 150000 200000 250000

120

100

CO
80
0) .3
CO
(I)
U)
0
CO 60-
a
F—
C
CO
U

a.
40-

20-

‘p.

rnovcmlnt
flflfl COflYROL

flN
nflocrnTIon
flTCftflhTIOflflL Inc.
0- 0

70
60
50 o
40
30
20
10
—= ::: 16
—v
10 20 30 40 50 60 70 80
q. — Volume Flow 3
(m
/ s)

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle . Angle •
..

—24 —17 —10 —3 —7 —14 —17 —26 —21 —14 —9 —1 —5 —12 —17 —25
8 8
—21 —13 —15 —8 —4 —7 —9 —19 —18 —10 —14 —6 —3 —6 —8 —18
—19 —17 —11 —3 —7 —12 —17 —21 —15 —14 —10 —3 —5 —11 —14 —20
16 16
—13 —6 —11 —11 —9 —8 —7 —15 —9 —3 —10 —10 —8 —8 —7 —13
—8 —10 —10 —8 —7 —8 —12 —12 —8 —7 —7 —7 —10 —11
24 36 24 36
—8 —7 —9 —9 —9 —9 —12 —13 — —3 —4 —7 —8 —7 —9 —10 —12

SK11863 04/03/99
JM AEROFOIL
Fan Code: 1 60J M15016191...
WOODS
AIR MOVEMENT
I 1
BS5750P11

150 9001
1600 mm 960 rev/mm 9 Blades 50 Hz
Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown is for installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/min
3
ft 0 20000 40000 60000 80000 100000 120000 140000 -

I I I I I I rrri in
wg wg
/hr
3
m 0 50000 100000 150000 200000
120

100

80
ci)
D
.3 C
0
0
ci)
0
a) 60 -

C
cci
I-i

a
40•

20

0- 0
0 10 20 30 40 50 60 70
70
ci)
0
60
50
U
0
40
ci) 30
0
0
20
10
0

q — Volume Flow (m
Is)
3
If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle •j Angle
—20 —13 —8 —4 —7 —12 —14 —25 —17 —10 —7 —3 —5 —11 —13 —23
8 8
—20 —16 —14 —8 —4 —7 —7 —21 —16 —13 —13 —7 —4 —6 —6 —19

—18 —13 —7 —4 —8 —13 —18 —23 —14 —11 —5 —3 —6 —12 —16 —21
16 16
—11 —11 —10 —9 —8 —7 —7 —17 —8 —7 —8 —7 —7 —5 —6 —16

h1 —11 —8 —5 —7 —11 —15 —16 —8 —8 —6 —4 —6 —9 —13 —15


24 36 24 36
—8 —9 —8 —8 —9 —10 —12 —14 — —5 —6 —6 —6 —8 —8 —10 —12

SK11864 04/03/99
JMAEROFOIL
c Fan Code: 160JM150161121.. WOODSI AIR MOVEMENT *‘

1600 mm 960 rev/mm 12 Blades 50 Hz


8s5750Pt1
EN 29001
iso 9001

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only
Performance shown isfor installationstype C— Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

/ft
3
min 0 20000 40000 60000 80000 100000 120000 140000 160000
I I I I I I I I trim in
I I I I wg wg
m
/
3 hr 0 50000 100000 150000 200000 250000
140 -

.5
120 -

100-
I.
( ..
0
ci)
D
C),
C,)
a) 80-
ci 3
(a
0
I—
C 60
(0
U

0
-2

40

20
I vcmlflr
(no COATROI
(HOCIATICA
TEflflhTIOflTL Inc

0- 0

80
C 70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80
q — Volume Flow (m
/s)
3

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Sound Data BS848 Part 2 1985:


Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory
specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use
upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels


Pitch Octave Band Centre Frequency (Hz) Pitch Octave Band Centre Frequency (Hz)
Angle Angle •• •

—23 —14 —7 —3 —8 —15 —17 —27 —21 —12 —6 —2 —7 —12 —15 —25
8 8
—22 —17 —13 —6 —5 —8 —9 —23 —19 —16 —11 —6 —3 —5 —6 —21
—17 —17 —12 —4 —5 —9 —13 —21 —14 —15 —10 —4 —4 —9 —10 —19
16 16
—13 —14 —10 —10 —7 —7 —6 —16 —9 —12 —7 —10 —7 —6 —3 —13
—9 —12 —9 —7 —7 —10 —13 —15 —6 —9 —6 —5 —6 —9 —12 —14
24— 36 24 36
—7 —10 —8 —8 —9 —9 —11 —15 — —3 —6 —6 —7 —8 —9 —10 —14

SK11865 04/03/99
n (Th cm
JM AEROFOIL
DIMENSIONS AND WEIGHTS WOO DS
AIR MOVEMENT

LONG CASED 315 1000 DIA UPTO 315 HUB - -

0132.0160.0180 FRAMES
40 DIA. HOLES FOR CONDUIT.
2 EACH SIDE SUITABLE FOR Pg29 OR 1.5
BT,CT F22 FRAMES
23 DiA. HOLES FOR CONDUIT. S NO. OF HOLES 01
2 EACH SIDE SUITABLE FOR CM2O OR Pg16 EOUISPACED ON [I PCD.

AIRFLOW
FORM A
AIRFLOW
FORM B

-GUARDS OPTIONAL

HOLE IN
FOOT 0 N

DIMENSION REFERENCE (mm) Fan


Motor —_

Code Frame A B C 0 E F G H J 1< L M N P S T V X WeIght I

315 BT4/519 315 395 375 235 2.5 25 175 355 66 289 265 315 10 200 8 10 30 0.7 22
CT5/9 315 395 375 235 2.5 25 175 355 66 289 265 315 10 200 8 10 30 0.7 27
j
355 BT41519 355 435 375 256 2.5 25 200 395 66 289 305 355 10 225 8 10 24
CT519 355 435 375 256 2.5 25 200 395 66 289 305 355 10 225 8 10 30 0.9 28
400 BT4/5/9 400 480 375 279 2.5 25 225 450 66 289 350 400 10 250 8 12 30 1.0 26
CTSI9 400 480 375 279 2.5 25 225 450 66 289 350 400 10 250 8 12 30 1.0 30
450 8T4/5/9 450 530 375 306 2.5 25 255 500 66 289 400 450 10 280 8 12 30 1.2 28
CT5/9 450 530 375 306 2.5 25 255 500 66 289 400 450 10 280 8 12 30 1.2 32
F2225/45/65 450 530 520 306 3 25 255 500 66 434 400 450 10 280 8 12 30 1.2 44
F2229149/69 450 530 520 306 3 25 255 500 66 434 400 jp 10 280 8 12 30 1.2 55
500 BT519 500 594 375 338 2.5 25 290 560 66 289 450 500 10 315 12 12 30 1.7 28
CT5/9 500 594 375 338 2.5 25 290 560 66 289 450 500 10 315 12 12 30 1.7 34
F2225/45/65 500 594 520 338 3 25 290 560 66 434 450 500 10 315 12 12 30 1.7 54
F2229)49/69 500 594 520 338 3 25 290 560 66 434 450 500 10 315 12 12 30 1.7 65
560 BT5/9 560 654 375 368 2.5 25 330 620 66 289 510 560 10 355 12 12 50 2.0 34
CT519 560 654 375 368 2.5 25 330 620 66 289 510 560 10 355 12 12 50 2.0 38
F2225/45/65 560 654 520 368 3 25 330 620 66 434 510 560 10 355 12 12 50 2.0 56
F2229149/69 560 654 520 368 3 25 330 620 66 434 510 560 10 355 12 12 50 2.0 67
630 BT5/9 630 724 375 403 3 25 375 690 66 289 580 630 10 400 12 12 50 2.5 48
CT5/9 630 724 375 403 3 25 375 690 66 289 580 630 10 400 12 12 50 2.5 52
F2225/45/65’ 630 724 520 403 3 25 375 690 66 434 580 630 10 400 12 12 I 50 2.5 70
j
F2225/49/69 630 724 520 403 3 25 375 690 66 434 580 630 10 400 12 12 50 2.5 81
D132 630 724 520 440 3 25 375 690 66 434 580 630 12 400 12 12 50 4.8 117
D160 630 724 625 440 3 25 375 690 66 529 580 630 12 400 12 12 50 4.8 195
710 CT519 710 804 375 443 3 25 415 770 66 259 660 710 10 440 16 12 50 4.5 54
F2225/45/65 710 804 520 443 3 25 415 770 66 404 660 710 10 440 16 12 50 4.5 74
F2229/49/69 710 804 520 443 3 25 415 770 66 404 660 710 10 440 16 12 50 4.5 85
D132 710 604 520 480 4 25 415 770 66 402 660 710 12 440 16 12 50 5.3 139
0160* 710 804 625 480 5 45 415 770 124 . 505 660 710 10 440 .16 12 50 5.3 205
Q* 0 804 7 480 6 45

770 589 0 0 4506 12 50 7.4, 280


800 CT519 800 894 375 488 3 25 485 860 66 259 750 800 10 510 16 12 50 7.0 63
F2225/45/65 800 894 520 488 3 25 485 860 66 404 750 800 10 510 16 12 50 7.0 83
F2229/49/69 800 894 520 488 3 25 485 860 66 404 750 800 10 510 16 12 50 7.0 94
D132 800 894 520 525 5 45 485 860 124 400 750 800 12 510 16 12 50 7.0 163
0160 800 894 625 525 5 45 485 860 124 499 750 800 12 510 16 12 50 7.0 220
0180 * 800 894 711 525 6 45 485 860 124 589 750 800 12 510 50 8.5 300
900 F2225/45/65 900 1006 520 538 3 25 491 970 66 444 850 900 10 518 16 15 50 4.5 88
: F2229/49/69, 900 1006 520 538 3 25 491 970 66 444 850 900 10 518 16 15 50 4.5 99
0132 r 900 1006 520 575 5 45 491 970 124 444 850 900 12 518 16
.

15 50 5.3 183

C 1000
0160
F2225/45/65
F2229/49/69
900
1000
1006
1106
625
520
575
588
5
3 25 547
970
1070
124
66
539
444
850
950
900
1000
12
10
518
574
16
16
15
15
50
50
5.3
5.3
252
96
1000 1106 520 588 3 25 , 547 1070 66 444 950 1000 10 574 16 15 50 5.3 107
0132 1000 1106 520 625 5 45 547 1070 124 444 950 1000 12 574 16 15 50 6.2 198
0160 1000 ‘ 1106 625 625 5 45 547 1070 124 539 950 1000 12 574 16 15 50 6.2 268
I

D180 * , 1000 , 1106 711 6 45 547 1070 124 629 950 1000 12 574 lU 15 50 12.5 328
61
JM AEROFOIL
DIMENSIONS AND WEIGHTS AIR MOVEMENT

LONG CASED 1000-1 600 DIA 400 & 500 HUB


T/BOX D200, W200, W225, W250 FRAMES
EXTERNAL LUBRICATORS
AVAILABLE ON D200 W200
2-HOLES AUXILIARY BOX W225 W25O FRAMES ONLY.
TAPPED Pg29 OPTIONAL EXTRA NOT SMOKEVENT 4UO/2HRS
1 x CM2O ENTRY 40 DIA. HOLES FOR CONDUIT.
2 EACH SIDE SUITABLE FOR EXTERNAL
LUBRICATORS S No. OF HOLES T DIA
Pg29 OR 1.5
[001-SPACED ON H PCD.

AIRFLOW

FORM A

AIRFLOW

FORM B

LCRS
M
DIMENSION REFERENCE ,,

Fan Fan
Weight Weight
Code Motor Frame A B C 0 E 0 H K L M N P S T V X (kg) (kg)
(kg) 400 Hub 500 Hub
1000 DF132/M/MNMS/MKIMSNMSB 1000 1106 610 629 5 547 1070 530 950 1000 16 574 16 15 50 12.5 230
1000 D132/18-26 1000 1106 610 629 5 547 1070 530 950 1000 16 574 16 15 50 12.5 200
1000 W132/M 1000 1106 610 629 5 547 1070 530 950 1000 16 574 16 15 50 12.5 199
1000 DF160/MA/MB/L/LM 1000 1106 750 630 6 547 1070 668 950 1000 16 574 16 15 50 12.5 324
1000 0160/20-40 1000 1106 750 630 6 547 1070 668 950 1000 16 574 16 15 50 12.5 321
1000 DF16O/LKE 1000 1106 750 630 6 547 1070 668 950 1000 16 574 16 15 50 12.5 330
1000 W160/L 1000 1106 750 630 6 547 1070 668 950 1000 16 574 16 15 50 12.5 276 (.
1000 DF18O/L/LM/LAN/LBN 1000 1106 800 630 6 547 1070 718 950 1000 16 574 16 15 50 12.5 420
1000 0180/40 1000 1106 800 630 6 547 1070 718 950 1000 16 574 16 15 50 12.5 403
1000 W180/L 1000 1106 800 630 6 547 1070 718 950 1000 16 574 16 15 50 12.5 407
1000 0200/36 -46 1000 1106 900 688 6 547 1070 818 950 1000 16 574 16 15 50 12.5 547
1000 D200/51/57 1000 1106 900 688 6 547 1070 818 950 1000 16 574 16 15 50 12.5 582
1000 W200/LF/LFR/LFG 1000 1106 900 688 6 547 1070 818 950 1000 16 574 16 15 50 12.5 520
1000 W225/M/MF 1000 1106 950 688 6 547 1070 868 950 1000 16 574 16 15 50 12.5 613
1120 DF132/M/MA/MS/MK/MSA/MSB 1120 1258 610 690 6 685 1190 468 1070 1120 14 710 20 15 50 16.5 267 282
1120 D132/18-26 1120 1258 610 690 6 685 1190 468 1070 1120 14 710 20 15 50 16.5 237 252
1120 W132/M 1120 1258 610 690 6 685 1190 468 1070 1120 14 710 20 15 50 16.5 236 203
1120 0F160/MA/MB/L/LM 1120 1258 750 690 6 685 1190 608 1070 1120 14 710 20 15 50 16.5 376 391
1120 D160/20-40 1120 1258 750 690 6 685 1190 608 1070 1120 14 710 20 15 50 16.5 372 387
1120 DF16O/LKE 1120 1258 750 690 6 685 1190 608 1070 1120 14 710 20 15 50 16.5 381 396
1120 W160/L 1120 1258 750 690 6 685 1190 608 1070 1120 14 710 20 15 50 16.5 327 342
1120 DF18O/L/LM/LAN/LBN 1120 1258 800 690 6 685 1190 658 1070 1120 14 710 20 15 50 16.5 445 460
1120 0180/40 1120 1258 800 690 6 685 1190 658 1070 1120 14 710 20 15 50 16.5 428 443
1120 W180/L 1120 1258 800 690 6 685 1190 658 1070 1120 14 710 20 15 50 16.5 432 447
1120 0200/36-46 1120 1258 900 748 6 685 1190 758 1070 1120 14 710 20 15 50 16.5 576 591
1120 D200/51/57 1120 1258 900 748 6 685 1190 758 1070 1120 14 710 20 15 50 16.5 611 626
1120 W200/LF/LFR/LFG 1120 1258 900 748 6 685 1190 758 1070 1120 14 710 20 15 50 16.5 549 564
1120 W225/M/MF 1120 1258 950 748 6 685 1190 808 1070 1120 14 710 20 15 50 16.5 643 658
1120 W250/M/MF 1120 1258 1050 748 6 685 1190 908 1070 1120 14 710 20 15 50 16.5 851 866

62
JMAEROFOIL
DIMENSIONS AND WEIGHTS AIRMOVEMENT
woos’
LONG CASED 1000-1 600 DIA 400 & 500 HUB

Code Motor Frame A B C D E 0 H K L M N P S T V


40J Hub 500 Hub
1250 DF132/MIM1JMS/MKJMSA/MSB 1250 1388 610 755 6 750 1320 468 1150 1250 14 800 20 15 50 20.6 284 300
1250 0132/18 -26 1250 1388 610 755 6 750 . 1320 468 1150 1250 14 800 20 15 50 20.6 254 270
1250 W132/M 1250 1388! 610 755 6 750 1320 468 1150 1250 14 800 20 15 50 20.6 253 269
1250 DF16O/MA/MB/L/LM 1250 1388 750 755’ 6 750 1320 608 1150 1250 14 800 20 15 50 20.6 398 413
1250 0160/20 -40 1250 1388 750 755 6 750 1320 608 1150 1250 14 800 20 15 50 20.6 394 411
1250 DF16O/LKE 1250 1388 750 755 6 750 1320 608 1150 1250 14 800 20 15 50 20.6 403 418
1250 W160/L 1250 1388 750 755 6 750 1320 608 1150 1250 14 800 20 15 50 20.6 349 364
1250 DF18O/L/LM/LAN/LBN 1250 1388 800 755 6 750 1320 658 1150 1250 14 800 20 15 50 20.6 467 482
1250 0180/40 1250 1388 800 755 6 750 1320 658 1150 1250 14 800 20 15 50 20.6 450 465
1250 W180/L 1250 1388 800 755 6 750 1320 658 1150 1250 14 800 20 15 . 50 20.6 454 469
1250 0200/36/38/40/46 1250 1388 900 813, 6 750 1320 758 1150 1250 14 800 20 15 50 20.6 603 617
1250 0200/51/57 1250 1388 900 813 6 750 1320 758 1150 .1250 14 800 20 15 50 20.6 638 652
1250 W200/LF/LFR/LFG 1250 1388 900 813 6 750 1320 758 1150 1250 14 800 20 15 50 20.6 575 589
1250 W225/M/MF 1250 1388 950 813 6 750 1320 808 1150 1250 14 800 20 15 50 20.6 670 686
1250 W250/M/MF 1250 1388 1050 813 6 750 1320 908 1150 1250 14 800 20 15 50 20.6 879 896
1400 0F132/M/MA/MS/MSA/MSB 1400 1538 610 830 6 850 1470 468 1300 1400 14 900 20 , 15 50 34.3 319 338
1400 D132/18-26 1400 1538 610 830 6 850 1470 468 1300 1400 14 900 20 15 50 34.3 289 308
1400 W132/M 1400 1538 610 830 6 850 1470 468 1300 1400 14 900 20 15 50 ‘ 34.3 288 307
1400 !0F160/MA/MB/L/LM 1400 1538 750 830 6 850 1470 608 1300 1400 14 900 20 15 . 50 34.3 446 464
1400 0160/20-40 1400 1538 750 830 6 850 1470 608 1300 1400 14 900 20 15 50 34.3 442 460
1400 DF16O/LKE 1400 1538 750 830 6 850 1470 608 1300 1400 14 900 20 15 50 34.3 451 469
1400 W160/L 1400 1538 750 830 6 850 1470 608 1300 1400 14 900 20 15 50 34.3 397 415
1400 DF18O/L/LM/LAN/LBN 1400 1538 800 830 6 850 1470 658 1300 1400 14 900 20 15 50 34.3 516 534
1400 D180/40 1400 1538 800 830 6 850 1470 658 1300 1400 14 900 20 15 50 34.3 499 517
1400 W180/L 1400 1538 800 830 6 850 1470 658 1300 .1400 14 900 20 : 15 50 34.3 503 521
1400 0200/36-46 1400 1538 900 888 6 850 1470 758 1300 ‘1400 14 900 20 ‘ 15 50 34.3 641 658
1400 0200/51/57 :1400 1538 900 888 6 850 1470 758 1300 1400 14 900 20 15 50 34.3 676 693
1400 W200/LF/LFR/LFG 1400 1538 900 888 6 850 1470 758 1300 1400 14 900 20 15 50 34.3 550 567
1400 W225/M/MF 1400 1538 950 888 6 850 1470 808 1300 1400 14 900 20 15 50 34.3 711 730
1400 W250/M/MF 1400 1538 1050 888 6 850 1470 908 1300 1400 14 900 20 15 50 34.3 872 892
1600 0F132/M/MA/MS/MSA/MSB 1600 1760 610 930 6 950 1680 468 1500 1600 14 1006 24 20 50 40.7 354 374
1600 0132/18 -26 1600 1760 610 930 6 950 , 1680 468 1500 1600 14 1000 24 20 50 40.7 324 344
1600 W132/M 1600 1760 610 ‘ 930 6 950 1680 468 1500 1600 14 1000 24 20 50 40.7 323 343
1600 0F160/MA/MB/L/LM 1600 1760 750 930. 6 950 1680 608 1500 1600 14 1000 24 20 50 40.7 472 490
1600 0160/20-40 1600 1760 750 930’ 6 950 1680 608 ‘1500 1600 14 1000 24 20 50 40.7 468 486
1600 DF160/LKE 1600 1760 750 930 6 950 1680 608 1500 1600 14 1000 24 20 50 40.7 476 494
1600 W160/L 1600 1760 750 930 6 950 1680 608 1500 1600 14 1000 24 20 50 40.7 423 441
1600 DF18O/L/LM/LAN/LBN 1600 1760 800 930 6 950 1680 658 1500 1600 14 1000 24 20 50 40.7 559 578
1600 D180/40 1600 1760 800 930 6 950 1680 658 1500 1600 14 1000 24 20 50 40.7 642 661
1600 W180/L 1600 1760 800 930 6 950 1680 658 1500 1600 14 1000 24 20 50 40.7 546 565
1600 0200/36/38/40/46 1600 1760 900 988: 6 950 1680 758 1500 1600 14 1000 24 20 50 40.7 688 706
!
1600 0200/51/57 1600 1760 900 988’ 6 950 1680 758 ‘1500 ‘1600 14 1000 , 24 20 50 40.7 723 741
1600 W200/LF/LFR/LFO ‘1 600 1760 900 988 6 950 1680 758 1500 1600 14 1000 24 20 ‘ 50 40.7 660 678
1600 W225/M/MF 1600 1760 950 988 6 950 1680 808 1500 1600 14 1000 24 20 50 40.7 758 777
1600 W250/M/MF 1600 1760 1050 988 6 950 1680 908 1500 1600 14 1000 24 20 50 40.7 973 993

63
JM AEROFOIL
WOODS
DIMENSIONS AND WEIGHTS AIR MOVEMENT
(•‘

SHORT CASED 315- 1000 DIA UPTO 315 HUB -

BTCT FRAMES
AND 3 PHASE SUPPLY SUITABLE FUR 7 -
10.5 mm DIA CABLE.
WHERE IMPELLER SIDE GUARD IS FITtED
ON THE MOTOR SIDE THE GUARD
ENCLOSES THE MDTOR. A HOLE 15 DIk IS
PROVIDED IN THE DUCT FOR CUSTOMERS
SUPPLY LEADS.
F22 FRAMES
ENTRY FDR CM2S CONDUIT SUITABLE FOR
AIRFLOW — 0-13mm DIV. CABLE.
----- <
FDRMA
AIRFLOW
FORMB

D132 FRAMES
CABLE ENTRY 2- KNOCKOUTS 26 DIA FOR CM25
WHERE A MOTOR SIDE GUARD IS FIllED WITH D132-D1 80
FRAMES THE GUARD ALSO ENCLOSES MOTOR. U HDLU 25 DIA. FOR D1ROI2D/23126/28/32 FRAMES
LEADS IS PROVIDED IN THE SAME POSITION ON DUCT. 2-KNDCKDUTSFORCM32

—1i—
--

D1UWL/LMJLMA/LBK FRAMES
2- HOLES TAPPED CM32
DPi BO/L tM/1.MB
2- HOLES TAPPED CM 32
I.
Code Motor Frame
1 A B C D
DIMENSION REFERENCE (mm)
E H S T V
FUn
Weight (kg)
315 BT4/5 315 395 301 225 2.5 355 8 10 - 13.5
8T9 315 395 333 225 2.5 355 8 10 - 15
0T5 315 395 308 225 25 355 8 10 - 15.5
CT9 315 395 348 225 2.5 355 8 10 - 20
355 874/5 355 435 301 225 2.5 395 8 10 - 14
879 355 435 333 225 2.5 395 8 10 - 15.5
CT5 355 435 308 225 2.5 395 8 10 - 16.5
075 355 435 348 225 2.5 395 10 - 20.5
400 BT4/5 400 480 301 225 2.5 450 8 12 - 15
BT9 400 480 333 225 2.5 450 8 12 - 16.5
CT5 400 480 308 225 2.5 450 8 12 - 17
CT9 400 480 348 225 2.5 450 8 12 - 21
450 BT4/5 450 530 301 225 2.5 500 8 12 - 17
BT9 450 530 333 225 2.5 500 8 12 - 18.5
0T5 450 530 308 225 2.5 500 8 12 - 19
079 450 538 348 225 2.5 500 8 12 - 23
F2225/45/65 450 530 404 225 3 500 8 12 - 33
F2229149169 450 530 459 225 3 500 8 12 - 44
500 BT5 500 594 301 225 2.5 560 12 12 - 19
BT9 500 594 333 225 2.5 560 12 12 - 20
CT5 500 594 308 225 2.5 560 12 12 - 20.5
CT9 500 594 348 225 2.5 560 12 12 - 25
F2225/45/65 500 594 404 225 3 560 12 12 - 36
F2229/49/69 500 594 459 225 3 560 12 12 - 47
560 BT5 560 654 301 225 2.5 620 12 12 - 20
BT9 560 654 333 225 2.5 620 12 12 - 21.5
CT5 560 654 308 225 2.5 620 12 12 - 22
CT9 560 654 348 225 2.5 620 12 12 - 26
F2225145165 560 654 404 225 3 620 12 12 - 38
F2229/45/S9 560 654 459 225 3 620 12 12 - 49
630 BT5 630 724 301 225 3 690 12 12 - 34
BT9 630 724 333 225 3 690 12 12 - 35.5
CT5 630 724 308 225 3 690 12 12 - 36
CT9 630 724 348 225 3 690 12 12 - 40
F2225/45/65 630 724 404 225 3 690 12 12 - 49
F2229/49/69 630 724 459 225 3 690 12 12 - 60
D132 630 724 445 260 4 690 12 12 160 94
0160 630 724 575 260 4 690 12 12 200 172
*
0180 630 724 656 350 6 690 12 12 243 287
710 CT5 710 804 308 225 3 770 16 12 - 38
CT9 710 804 348 225 3 770 16 12 - 42
F2225/45/65 710 804 404 225 3 770 16 12 - 52
F2229/49/69 710 804 459 225 3 770 16 12 - 63
0132 710 804 445 260 4 770 16 12 160 102
*
D160 710 804 609 300 5 770 16 12 201 185
*
0180 710 804 665 350 6 770 16 12 243 287
800 075 800 894 308 225 3 860 16 12 - 43
CT9 800 894 348 225 3 860 16 12 - 47
F2225/45/65 800 894 404 225 3 860 16 12 - 58
F2229/49/69 800 894 459 225 3 860 16 12 - 58
0132 800 894 445 260 4 860 16 12 160 132
0160 800 894 575 260 4 860 16 12 200 189
*
0180 800 894 665 350 6 860 . 16 12 243 295
900 F2225/45/65 900 1006 I 404 225 3 970 16 15 - GO
F2229/49/69 900 1006 459 225 3 970 16 15 - 71
D132 900 1006 445 300 5 970 16 15 160 138
0160 900 1006 575 300 5 970 16 15 200 207
1000 F2225/45/65 1000 1106 404 225 3 1070 16 15 - 65
F2229/49/69 1000 1106 459 225 3 1070 16 15 - 76
0132 1000 1106 445 300 5 1070 16 15 160 146
0160 1000 1106 575 300 5 1070 16 15 200 217
0180* 1000 1106 700 350 6 1070 16 15 243 350
j
64
JM AEROFOIL
CS
DIMENSIONS AND WEIGHTS AIR MOVEMENT

SHORT CASED 1000-1 600 DIA 400 & 500 HUB


DUCT MOUNTED T/BOX OPTION:

*
FANS WITHOUT DUCT T/BOX:
A HOLE IS PROVIDED IN THE
DUCT FOR CUSTOMERS SUPPLY
LEADS, 25 DIA. UP TO D18D,
51 DIA. D200 W250.

AIRFLOW

FORM A

C”
AIRFLOW

FORM B

FANS WITHOUT DUCT T/BOX:


CONDUIT ENTRIES:
D132 FRAMES 2 X CM25
016U DIED FRAMES 2 X CM32
-

D
O
2 C) FRAMES 2 X t
1 or Frame

DIMENSION REFERENCE (mm) Fan


Weight (kg)
A B C D E H L S T V W400Hub
1000 DF132JM/MA/MAJMSAIMSB/MK 1000 1106 558 350 5 1070 629 16 15 175 262 205
1000 0132/18-26 1000 1106 518 350 5 1070 629 16 15 158 262 173
1000 W132/M 1000 1106 520 350 5 1070 629 16 15 155 262 174
1000 DF16O/MA/MB/LJLM/AK/BK 1000 1106 628 350 6 1070 630 16 15 219 372 292
1000 0F160/LKE 1000 1106 687 350 6 1070 630 16 15 219 372 298
1000 D160/18-38 1000 1106 625 350 6 1070 630 16 15 201 372 290
1000 D160140 1000 1106 685 350 6 1070 630 16 15 201 372 295
1000 W160/L 1000 1106 626 350 6 1070 630 16 15 196 372 243
1000 0F180/L/1M 1000 1106 680
Cl 1000 DF180/LAN/LBN 1000 1106 720
350
350
6
6
1070
1070
630
630
16
16
15
15
243
243 .
372
427
348
364
• 1000 0180/29-35 1000 1106 718 350 6 1070 630 16 15 . 243 427 334
1000 0180/40 1000 1106 742 350 6 1070 630 16 15 243 427 347
: 1000 W180/L 1000 1106 682 350 6 1070 630 16 I 15 216 372 351
1000
1000
0200/36 -46
0200/51/57
1000
1000
j 1106
1106
785
856
350
350
6
6
1070 688 I 16 15 263 527 458
1070 688 16 15 281 527 493
1000 W200/LF/LFR/LFG 1000 1106 835 350 6 1070 688 16 15 275 527 429
1000 W225/M/MF 1000 1106 878 350 6 1070 688 16 15 295 572 518
1000 W250/M/MF 1000 1106 992 350 6 1070 688 16 15 325 702 713
1120 DF132/M/MA/MS/MSAIMSB/MK 1120 1258 558 350 6 1190 690 20 15 175 262 220
1120 0132/18-26 1120 1258 518 350 6 1190 690 20 15 158 262 187
1120 W1321M 1120 1258 520 350 6 1190 690 20 15 155 262 188
1120 DF16O/MNMB/LILM/AK/BK 1120 1258 628 350 6 1190 690 20 15 219 372 300
1120 0F160/LKE 1120 1258 687 350 6 1190 690 20 15 219 372 305
1120 0160/18-38 1120 1258 625 350 6 1190 I 690 20 15 201 372 295
11200160/40 112O:125868535061190690 2015:201 372i 301
1120 W160/L i 1120 j 1258 626 350 6 1190 I 690 I 20 15 196 372 I 251
1120 0F180/LJLM 1120 1258 680 350 : 6 1190 690 20 15 243 372 348
1120 DF18O/LAN/LBN 1120 1258 720 350 6 1190 690 20 15 243 427 364
1120 0180/29-35 1120 1258 718 350 6 1190 690 20 15 243 427 351
1120 0180/40 1120 1258 742 350 6 1190 690 20 15 243 427 364
1120 W180/L 1120 1258 682 350 6 1190 690 20 15 216 372 353
1120 0200/36-46 1120 1258 785 350 6 1190 748 20 15 263 527 477
1120 0200/51/57 1120 1258 856 350 6 1190 748 20 15 281 527 511
1120 W200/LF/LFR/LFG 1120 1258 835 350 6 1190 748 20 15 275 527 447
1120 W225/M/MF 1120 1258 878 350 6 1190 748 20
C 1120 W250/M/MF 1120 1258 992 350 6 1190 748 20
15
15
295
325
572
702 I
537
728

65
JM AEROFOIL
DIMENSIONS AND WEIGHTS MR MOVEMENT

SHORT CASED 1000-1 600 DIA 400 & 500 HUB

DIMENSION REFERENCE (mm) Fan Fan


Weight (kg) Weight (kg)
Code Motor Frame A B C D E H L S T V 400 Heb 500 [lob

1250 DF132/M/MA/MS/MK/MSNMSB 1250 1388 558 350 6 1320 755 20 15 175 262 232 248
1250 0132/18-26 1250 1388 518 350 6 1320 755 20 15 158 262 200 216
1250 W132/M 1250 1388 520 350 6 1320 755 20 15 155 262 201 217
1250 0F160/MA’MB/L/LM/AK/BK 1250 1388 628 350 6 1320 755 20 15 219 372 312 327
1250 DF16O/LKE 1250 1388 687 350 6 1320 755 20 15 219 372 317 332
1250 0160/18-38 1250 1388 625 350 6 1320 755 20 15 201 372 304 320
1250 D160/40 1250 1388 685 350 6 1320 755 20 15 201 372 309 326
1250 W16O/L 1250 1388 626 350 6 1320 755 20 15 196 372 263 278
1250 0F180/L/LM 1250 1388 680 350 6 1320 755 20 15 243 372 365 380
1250 DF180/LAN/LBN 1250 1388 720 350 6 1320 755 20 15 243 427 381 396
1250 0180/29-35 1250 1388 718 350 6 1320 755 20 15 243 427 368 383
1250 0180/40 1250 1388 742 350 6 1320 755 20 15 243 427 381 396
1250 W18O/L 1250 1388 682 350 6 1320 755 20 15 216 372 370 385
1250 0200/36-46 1250 1388 785 350 6 1320 813 20 15 263 527 491 505
1250 D200/51/57 1250 1388 856 350 6 1320 813 20 15 281 527 525 539
1250 W200/LF/LFR/LFG 1250 1388 835 350 6 1320 813 20 15 275 527 488 498
1250 W225/M/MF 1250 1388 878 350 6 1320 813 20 15 295 572 551 567
1250 W250/M/MF 1250 1388 992 350 6 1320 813 20 15 325 702 742 759
1400 DF132/M/MNMS/MSNMSB 1400 1538 558 350 6 1470 830 20 15 175 262 259 268
1400 D132/18-26 1400 1538 518 350 6 1470 830 20 15 158 262 227 236
1400 W132/M 1400 1538 520 350 6 1470 830 20 15 155 262 228 237
1400 DF16O/MA/MB/LILMIAKIBK 1400 1538 628 350 6 1470 830 20 15 219 372 342 350
1400 DF16O/LKE 1400 1538 687 350 6 1470 830 20 15 219 372 347 355
1400 0160/18-38 1400 1538 625 350 6 1470 830 20 15 201 372 334 342
1400 0160/40 1400 1538 685 350 6 1470 830 20 15 201 372 340 348
1400 W160/L 1400 1538 626 350 6 1470 830 20 15 196 372 293 301
1400 DF18O/L/LM 1400 1538 680 350 6 1470 830 20 15 243 372 389 401
1400 DEl 80/LAN/LBN 1400 1538 720 350 6 1470 830 20 15 243 427 404 413
1400 0180/29-35 1400 1538 718 350 6 1470 830 20 15 243 427 392 401
1400 0180/40 1400 1538 742 350 6 1470 830 20 15 243 427 405 413
1400 W180/L 1400 1538 682 350 6 1470 830 20 15 216 372 394 402
1400 D200/36-46 1400 1538 785 350 6 1470 888 20 15 263 527 515 524
1400 0200/51/57 1400 1538 856 350 6 1470 888 20 15 281 527 549 558
1400 W200/LF/LFR/LFG 1400 1538 835 350 6 1470 888 20 15 275 527 485 494
1400 W225/M/MF 1400 1538 878 350 6 1470 888 20 15 295 572 575 584
1400 W250/M/MF 1400 1538 992 350 6 1470 888 20 15 325 702 767 779
1600 DF132/M/MAIMS/MSNMSB 1600 1760 558 350 6 1680 930 24 20 175 262 285 304
1600 0132/18-26 1600 1760 518 350 6 1680 930 24 20 158 262 253 272
1600 W132/M 1600 1760 520 350 6 1680 930 24 20 155 262 254 273
1600 DF16O/MWMB/LJLM/AKJBK 1600 1760 628 350 6 1680 930 24 20 219 372 365 383
1600 DF16O/LKE 1600 1760 687 350 6 1680 930 24 20 219 372 370 388
1600 0160/18-38 1600 1760 625 350 6 1680 930 24 20 201 372 359 367
1600 0160/40 1600 1760 685 350 6 1680 930 24 20 201 372 364 372
1600 W160/L 1600 1760 626 350 6 1680 930 24 20 196 372 316 334
1600 DF18O/LILM 1600 1760 680 350 6 1680 930 24 20 243 372 412 432
1600 DF180/LAN/LBN 1600 1760 720 350 6 1680 930 24 20 243 427 428 447
1600 0180/29-35 1600 1760 718 350 6 1680 930 24 20 243 427 415 434
1600 0180/40 1600 1760 742 350 6 1680 930 24 20 243 427 428 447
1600 W180/L 1600 1760 682 350 6 1680 930 24 20 216 372 417 436
1600 0200/36-46 1600 1760 785 350 6 1680 988 24 20 263 527 544 562
1600 0200/51/57 1600 1760 856 350 6 1680 988 24 20 281 527 578 596
1600 W200/LF/LFR/LFG 1600 1760 835 350 6 1680 988 24 20 275 527 514 532
1600 W225/M/MF 1600 1760 878 350 6 1680 988 24 20 295 572 605 624
1600 W250/M/MF 1600 1760 992 350 6 1680 988 24 20 325 702 796 816

C
66
JM AEROFOIL
WOODS AIR MOVEMENT

ANCILLARIES
SILENCER - B TYPE
Suitable Weight (kg)
forfan B C
•1 ØA Btype Ctype
315 4Th 3Th i0Z
I- -

355 455 355 12 15 .

400 500 400 15 18


450 600 450 20 24
POD-TYPECONLY
500.65050025
560 710 560 30
630 780 630 35
Tapped hole to 710 860 710 44 53
match fan flange 800 1000 800 55 66
900 1100 900 70 84
1000 12001000 82 100
1120 1320 1Th0 UJO 118
The above silencers give the approximate dB(A) reductions:- 1250 1450 1219 127 .147
B Type 1 diameter length 7 to 10 dB(A) - 1400 1600 1400] 193 220
C Type 1 diameter length 12 to 15 dB(A) - 1600 1800 11600 311 362
For full acoustic details contact our
Woods Acoustic Division. Tel: +44 (0) 1206 544122

MATCHING FLEXIBLE DAMPER


Suitable Weight (kg) FLANGE CONNECTION
forfan D E F G Matching Flexible D
0 Damper E
Flange Connection
315 32 110 225 - 1.1 3.3 8
355 32 110 J 225 - 1.3 3.9 9
400 32 110 225 17 1.5 4.5 10
450 32 110 225 39 1.7 5.0 12
500
560 32 110
225
225
75
125
2.0
2.3
[ 5.5
6.8
16
18
630 50 160 225 176 3.0 7.5 20
710 50 160 225 210 3.2
-

I 1-
8.1 23
800 50 160 225 270 3.6 9.1 27
900 50 160 225 305 4.1 10.4 31
1000 50 160 225 345 4.6 11.6 36
1120 51 165 400 225 5.2 12.9 150
1250 51 165 400 290 5.8 14.4 166
1400 51 165 430 335 11.9 24.4 270
1600 51 165 435 r435 14.8 30.3 300

SPEED CONTROLLER

Type A B C 0
A
ME1.1 104 83 55 40
ME1.3 148 87 62 47
ME1.6 148 87 62 47
MT1.1 124 124 60 52
/SPEED CONTROLLERJ
MT1.5 160 270 196 161
MT1.8 160 270 196 161
MT3.0.5 160 270 196 161
MT3.1 160 270 196 161
MT3.2 160 270 196 161
ME3.2D 225 192 96 80
ME1.12 210 180 81 65
MT1.12 236 316 188 153
All dimensions in mm and kgs

67
JM AEROFOIL
WOODS
AIR MOVEMENT
C
ANCILLARIES

GUARDS Suitable Weight


TYPE TYPE II TYPE III TYPE IV for fan Type C kg
Impeller Side (all) Motor Side (S Type) Motor Side (S Type) Beilmouth & 0A (max.) (max.)
& Motor Side (F22) (D132 & above) Motor Side L
315 I 137 1.2
(BT & CT) type (all)
315 IV 30 0.5
C I 137
--
355 1.4
355 IV 30 0.5
400 I 137 1.6
400 IV 30 0.6
450 I 137 1.8
450 II 137 1.6
450 IV 30 0.6
220 Dia. cut out
at centre 500 I 137 2.0
500 II 137 1.8
500 IV 30 0.7
560 I 137 2.2
560 II 137 2.0
560 IV 50 1.0
630 I 137 2.8
630 II 137 2.6
630 HI 350 3.0
630 IV 50 1.2
710 I 137 3.2
710 II 137 3.0
710 III 350 3.4
710 IV 50 1.4
BELLMOUTH
Suitable 800 137 3.5
ht 800 H 137 3.3
an C D
(kg)
800 1W 350 3.9
800 IV 50 1.5
315 65 379 1.0
900 I 137 4.2
355 85 423 1.2
900 II 137 4.2
400 80 480 1.5
900 III 310 4.8
450 95 536 2.0
900 IV 50 1.7
500 87 600 3.2
1000 I 137 5.0
560 100 668 4.0
1000 II 137 4.8
630 108 757 4.8
1000 III 310 5.6
710 126 857 5.4
1000 f 50 2.0
800 134 957 6.8
1120 137 7.1
900 150 1077 8.0
1120 III 572 11.8
1000 167 1199 17.8
1120 IV 50 6.9
1120 188 1349 19.9
1250 I 137 6.4
1250 210 1504 25.0
1250 III 572 12.0
1400 250 1680 31.0
1250 IV 50 6.4
1600 260 1906 46.0
1400 I 137 8.0
1400 III 572 13.5
VIBRATION ISOLATORS 1400 IV 50 7.1
Load range 1600 I 137 9.0
per
Type A B C D 6 F G H 1600 III 702 18.9
mounting
(kg) 1600 IV 50 8.8
M7 Green 0-3 64 43 2 15 20 50 7 M6
Mi Black 3-5 64 43 2 15 20 50 7 M6
M25 Green 5-20 85 56 2 30 25 66 8 M8
M25 Black 19-40 85 56 2 30 25 66 8 M8
M200 Green 38-130 151 101 3 55 45 124 11.5 M10
M200 Black 90-220 151 101 3 55 45 124 11.5

For larger vibration isolators, please enquire

All dimensions in mm and kgs


C
68
JM AEROFOIL
USEFUL INFORMATION

FAN LAWS SPEED CHANGE CONSTANT SIZE CONSTANT DENSITY


- -

Volume Flow Rotational Speed


Pressure (Static, Dynamic and Total) (Rotational Speed)
2
Power Absorbed oo (Rotational Speed)
3
SIZE CHANGE CONSTANT SPEED CONSTANT DENSITY
- -

(For geometrically similar fans only)


Volume Flow (Impeller Diameter)
3
Pressure (Static, Dynamic and Total) (Impeller Diameter)
2
Power Absorbed (Impeller Diameter)
5
DENSITY CHANGE CONSTANT SPEED CONSTANT SIZE
- -

Volume Flow No change


Pressure (Static Dynamic and Total) oo Density
Power Absorbed Density

The laws can be combined where simultaneous changes in size, speed and
density are required.

AIR DENSITY Standard Air density is 1.2 kg/rn


3
One condition that gives Standard Air is:
16°C, 100 kPa barometric pressure, 65% relative humidity

CHANGE DUE TO TEMPERATURE


1 273 + Old Temperature 00
New Density =

CHANGE DUE TO ALTITUDE


Old Density x
( 273 + New Temperature°C
) 3
kg/rn

/ 288 0.00649 H
-
)4256
New Density = Old Density 3
kg/rn
‘qL 288
Where H = Height above sea level in metres

PRESSURE Dynamic Pressure = O.5p (V)


2 Pa

Where p = Air Density 3


kg/rn
V = Air Velocity rn/s

Total Pressure = StaticPressure + Dynamic Pressure

/s) x Total Pressure (Pa)


Volume flow (m
3
ABSORBED Absorbed Power = kW
POWER Total Efficiency xlO

69
WOODS
AIR MOVEMENT

Woods Air Movement Limited is represented in over 70 countries world-wide.


See our website for details www.woods-fans.com -

U.K.
England Wales Scotland &
South & South East Midlands & South West North of England
Woods Air Movement Limited Woods Air Movement Limited Woods Air Movement Limited
Tufnell Way Waterlinks House, Richard Street P.O. Box 142
Colchester C04 5AR Birmingham B7 4AA Manchester M60 1AQ
Telephone: +44 (0)1206 544122 Telephone: +44 (0)121 359 6633 Telephone: +44 (0)161 8480341
Facsimile: +44 (0)1206 574434 Facsimile: +44 (0)121 359 1818 Facsimile: +44 (0)161 8729847
E-mail: enquiry@woods-fans.com E-mail: birminghum@woods-fans.com E-mail: rn

Europe
Finland France Germany Italy
Woods Puhallin Oy Cie Française Woods Woods Ventilatoren GmbH Woods Italiana SpA
Ruosilanfle 2b 16 Burospoce Siemensstrosse 16 Via Montenero 55/51
00390 Helsinki F91772 BiOvres Cedex 40855 Ratingen 20092 Cinisello Balsamo
Finland France Germany Milan, Italy I,,,
Telephone: +35 895404770 Telephone: +33 (0) 160195594 Telephone: +49 210231068 Telephone: +39 0261 86091iç’..
Facsimile: +35 89540 47754 Facsimile: +33 (0) 160195571 Facsimile: +49 210239113 Facsimile: +39 0261 860947S:
E-mail: info©woods-puhallin.fi E-mail: woodsfr©gec-france.fr E-mail: woods@t-online.de E-mail: info©woods-italiana.it

International
Canada Singapore USA
Woods Air Movement (Canada) Ltd Woods Singapore Pte American Fan Company
401 Traders Blvd Marconi Building 2933 Symmes Road
Unit #8, Mississauga 3 Tai Seng Drive Fairfield
Ontario [41 2H8 Singapore 535216 Ohio 45014, USA
Canada Telephone: +65 3828233 Telephone: +15138742400
Telephone: +19055010211 Facsimile: +65 3828200 Facsimile: +15138706249
Facsimile: +19055010399 E-mail: froncis.ton©marconi.com.sg E-mail: af-soles©omfan-woods.com

Due to a policy of continuous development and improvement the right is reserved to Publication No: JM/SS
supply products which may differ from those illustrated and described in this publication. March 2000
Certified dimensions will be supplied on request on receipt of order.

© Copyrighi 2000 Woods Air Moven,ent Umied. 9ond


lEn