INSPECTION REPORT

CLIENT NAME & ADDRESS


NAME OF THE CLIENT   GENESIS EQUIPMENT SOLUTIONS 
ADDRESS  DUBAI 
DATE   25/08/2022 
CONTACT PERSON  MR. NIKKI KUMAR MAISURIYA 
REFERENCE /JOB NO:  JOB #21586 
PRODUCT  CUMMINS INJECTORS 
SUBJECT  IDS INSPECTION REPORT 
NATURE OF COMPLAIN  SERVICING 

• UPON INSPECTION WE FOUND INTERNAL PARTS SUCH AS 
PLUNGER, BARREL, STC KIT, AND OTHER INTERNAL PARTS ARE 
WORNOUT AND DAMAGED. 
FINDINGS & OBSERVATIONS • INJECTOR CUP’S ARE CONTAMINATED WITH CARBON  
AND HOLES ARE BLOCKED. 
 
 

• IT IS RECOMMENDED TO REPLACE INTERNAL PARTS OF  
INJECTORS AS PER THE QUOTATION TO BRING BACK
RECOMMENDATIONS
INJECTORS PERFORMANCE AS PER MANUFACTURER 
SPECIFICATION.  

Technician MR.WILSON
 
P I C T O R I A L    O B S E R V A T I O N 

PLUNGER & BARREL

BLOCKED CUP HOLES


STC KIT