You are on page 1of 2

EV12-100S(12V100Ah)

Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 100Ah@10hr-rate to 1.80V per cell @25℃
Weight Approx. 30.0 Kg (Tolerance±3.0%)
Internal Resistance Approx. 5.5 mΩ
Terminal F15(M6)/F12(M8)
Max. Discharge Current 1000A (5 sec)
Cold Cranking Ampere(CCA) 620A EV ( Electric Vehicle ) series is specially
designed for frequent discharge deep cycle
Maxi. Charging Current 30.0A application. By using the specially designed
C3 77.4AH active material, strong grids and thick plate
C5 87.5AH construction, the EV series battery offers
Reference Capacity reliable performance in high load situations
C10 100.0AH
C20 106.0AH and could provide competitive cycle
13.6 V~13.8 V @ 25℃ performance. It is suitable for Electric Vehicle
Float Charging Voltage and Golf cart, Floor Machines, Forklifts, Aerial
Temperature Compensation: -3mV/℃/Cell
lifts, Robotics, Marine, RV, Mobility and
14.6 V~14.8 V @ 25℃
Cycle Use Voltage Medical Equipment, and most outdoor
Temperature Compensation: -4mV/℃/Cell
application.
Discharge: -20℃~60℃
Operating Temperature Range Charge: 0℃~50℃
Storage: -20℃~60℃
Normal Operating Temperature Range 25℃±5℃
RITAR Valve Regulated Lead Acid (VRLA) batteries can ISO 9001 ISO 14001 OHSAS 18001
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charged batteries before using.

Container Material A.B.S. UL94-HB, UL94-V0 Optional.


MH 28539 G4M20206-0910-E-16

Dimensions
306.5 168.5 Φ16 Length 306.5±2mm (12.1 inches)
M8
Width 168.5±2mm (6.63 inches)
Height 210±2mm (8.27 inches)
5

Total Height 215±2mm (8.46 inches)


215

Terminal Value
210

M5 6~7 N*m
M6 8~10 N*m
24

M8 10~12 N*m
238
F12 Terminal Unit: mm

Constant Current Discharge Characteristics : A(25 ℃)


F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 241.1 191.0 111.7 61.7 36.4 28.2 22.2 18.9 12.7 10.5 5.52
1.65V 227.9 182.6 107.2 59.6 35.3 27.4 21.6 18.4 12.5 10.4 5.43
1.70V 209.8 171.0 102.5 57.7 34.1 26.6 21.0 17.9 12.4 10.3 5.36
1.75V 192.0 159.1 98.0 55.5 32.9 25.8 20.5 17.5 12.2 10.1 5.30
1.80V 173.8 146.9 93.6 53.4 31.7 25.0 19.9 17.0 12.0 10.0 5.25
1.85V 142.1 121.9 80.6 47.9 29.1 23.1 18.5 15.9 11.2 9.41 4.98
Constant Power Discharge Characteristics : WPC(25℃)
F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 409.9 333.8 202.9 116.0 69.1 53.9 42.6 36.4 24.8 20.7 10.9
1.65V 394.8 323.9 196.8 112.6 67.2 52.5 41.6 35.6 24.6 20.5 10.7
1.70V 370.1 307.9 190.0 109.6 65.3 51.3 40.6 34.8 24.2 20.2 10.6
1.75V 344.9 290.7 183.5 106.3 63.3 50.0 39.7 34.0 23.9 20.0 10.5
1.80V 317.7 272.2 177.1 102.8 61.4 48.6 38.7 33.3 23.6 19.8 10.4
1.85V 264.2 229.1 154.1 92.8 56.5 45.1 36.1 31.1 22.2 18.6 9.87
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
The battery must be fully charged before the capacity test. The C 10 should reach 95% after the first cycle and 100% after the third cycle.
EV12-100S(12V100Ah)
Charge Characteristic Curve for Cycle Use(IIUU) Charge Characteristic Curve For Cycle Use(IUI)
Temperature:25℃(77℉) Temperature:25℃(77℉)
Charge current(CA)

0.30 2.60 0.30 2.60

Charge Voltage (VPC)


Charge Voltage

Charge current(CA)

Charge Voltage (VPC)


0.25 2.50 0.25 2.50

0.20 2.40 0.20 2.40

Charge Voltage
0.15 2.30 0.15 2.30

0.10 2.20 0.10 2.20

0.05 2.10 0.05 2.10


Charge Current
Charge Current
0.00 2.00 0.00 2.00
6h~8h 2h~3h 2h~3h ≥5h 6h~8h ≤6h

Charging Time(h) Charging Time(h)

Cycle Life in Relation to Depth of Discharge Storage Characteristics


120 100

100
80
Capacity (% )
80
Capacity(%)

60

60
100% 80% 50%
DOD DOD DOD 40
40

20
20

0 0
200 400 600 800 1000 1200 1400 0 2 4 6 8 10 12 14 16 18 20 22 24
Number of Cycles Storage Time(months)

Discharge Characteristics Curve Relationship Between Charging Voltage and Temperature


Temperature:25℃(77℉) 2.70
(V/cell)

2.16
2.60
Charge Voltage (v )
Terminal Voltage (v )

2.00
Cycle use
2.43~2.47VPC@25℃
2.50
1.84
0.1C 0.05C
1.68 0.4C 0.2C
2.40
0.55C
3C 2C 1C
1.52
2.30
1.36 Float charging
2.27~2.30VPC@25℃
0 2.20
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 -20 -10 0 10 20 30 40 50
min h

Discharge Time Temperature (℃)

Relationship of OCV And State of Charge(20℃) Temperature Effects on Capacity

2.20 120

2.15 100
Battery Voltage (V)

0 .1 C A
2.10
Capacity (% )

80 0 .2 C A
2.05

60
2.00

1.95 1 .0 C A
40
2 .0 C A
1.90
3 .0 C A
20
1.85

1.80 0
0 10 20 30 40 50 60 70 80 90 100 -20 -10 0 10 20 30 40 50

State Of Capacity (%) Temperature (℃)

(Note) All above information shall be changed without prior notice, Ritar reserves the right to explain and update the latest information.

HENGYANG RITAR POWER CO.,LTD. Add: No.1 Huagong Road, Songmu Industrial Park, Shigu District, Hengyang, Hunan, China 421001
URL: www.ritarpower.com Tel: +86-734-8595528 Fax: +86-734-8595518 E-mail: sales@ritarpower.com Version 19A-0

You might also like