You are on page 1of 2

RA12-200D(12V200Ah)

Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity 200Ah@20hr-rate to 1.75V per cell @25℃
Weight Approx. 60.0 Kg (Tolerance±1.5%)
Internal Resistance Approx. 4 mΩ
Terminal F10(M8)/F16(M8)
Max. Discharge Current 2000A (5 sec)
Design Life 12 years (floating charge) RA-D (Deep Cycle) series batteries provide
superior high integrity and reliability. It is
Maximum Charging Current 60.0 A specially designed for frequent cyclic
C3 154.8AH charge and discharge. By using strong
C5 176.0AH grids, thick plate and specially active
Reference Capacity
C10 198.00AH material are designed for repeated
C20 204.0AH deep-discharge applications. The DC
13.6 V~13.8 V @ 25℃ series batteries offers 30% more cyclic
Float Charging Voltage life than the standby series. It is suitable
Temperature Compensation: -3mV/℃/Cell
for solar and wind renewable energy
14.6 V~14.8 V @ 25℃ storage, mobility and medical equipment,
Cycle Use Voltage Temperature Compensation: -4mV/℃/Cell
RV, telecom, broadband and cable TV,
Discharge: -20℃~60℃ UPS systems etc.
Operating Temperature Range Charge: 0℃~50℃
Storage: -20℃~60℃
Normal Operating Temperature Range 25℃±5℃
RITAR Valve Regulated Lead Acid (VRLA) batteries can
be stored for up to 6 months at 25℃ and then recharging
Self Discharge is recommended. Monthly Self-discharge ratio is less
than 3% at 25℃.Please charged batteries before using.

Container Material A.B.S. UL94-HB, UL94-V0 Optional.

Dimensions
Φ20 Length 522±1mm (20.6 inches)
205 M8 Width 240±1mm (9.45 inches)
522 240
Height 219±1mm (8.62 inches)
5

Total Height 224±1mm (8.82 inches)


Terminal Value
140
224
219

M5 6~7 N*m
M6 8~10 N*m
M8 10~12 N*m
F10 Terminal
Unit: mm

Constant Current Discharge Characteristics : A(25 ℃)

F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 417.6 329.1 190.8 119.8 74.0 55.1 44.1 37.1 25.3 21.2 10.6
1.65V 403.7 319.3 186.8 117.5 72.7 54.3 43.4 36.7 25.1 20.8 10.5
1.70V 385.5 306.3 181.5 114.5 71.0 53.2 42.6 36.1 24.7 20.4 10.4
1.75V 361.2 289.0 174.3 110.4 68.8 51.6 41.5 35.2 24.2 19.8 10.2
1.80V 328.7 265.6 164.4 104.8 65.6 49.5 40.0 34.0 23.4 19.6 10.3
1.85V 284.3 233.3 150.4 96.8 61.1 46.4 37.8 32.3 22.4 19.2 9.96

Constant Power Discharge Characteristics : WPC(25℃)

F.V/Time 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V 710 575 347 224 140 105 84.6 71.6 49.5 42.2 21.5
1.65V 704 570 344 222 139 104 83.8 71.0 49.1 41.9 21.4
1.70V 680 552 336 217 136 102 82.5 70.0 48.4 41.3 21.1
1.75V 649 528 326 210 132 99.9 80.6 68.6 47.5 40.6 20.8
1.80V 601 492 311 201 127 96.1 77.9 66.5 46.2 39.5 20.3
1.85V 529 438 287 187 119 90.6 73.8 63.4 44.2 38.0 19.6
(Note) The above characteristics data are average values obtained within three charge/discharge cycle not the minimum values.
RA12-200D(12V200Ah)

Discharge Characteristics Curve Charge Characteristic Curve for Cycle Use(IU)


Temperature:25℃(77℉) Temperature:25℃(77℉)
(V/cell)
120 0.14 2.60
Charge Volume
2.16

Charge Voltage (VPC)


Charge Current (CA)
Terminal Voltage (v )

100 0.12 2.50

Charge Volume (%)


Charge Voltage
2.00

80 0.10 2.40
1.84
0.1C 0.05C
0.4C 0.2C 60 0.06 2.30
1.68 After 50% Discharge
0.55C
After 100% Discharge
3C 2C1C 40 0.04 2.20
1.52

1.36 20 0.02 2.10


Charge Current
0
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0.00 2.00
min h 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28

Discharge Time Charging Time(h)

Cycle Life in Relation to Depth of Discharge Relationship Between Charging Voltage and Temperature
120 2.70

100
2.60

Charge Voltage (v )
Cycle use
80
2.43~2.47VPC@25℃
Capacity(%)

2.50

60
100% 50% 30%
DOD DOD DOD 2.40

40

2.30
20 Float charging
2.27~2.30VPC@25℃
2.20
0 -20 -10 0 10 20 30 40 50
300 600 900 1200 1500 1800 2100
Number of Cycles Temperature (℃)

Temperature Effects on Capacity Storage Characteristics


120 100

100 0℃
0 .1 C A 80
Capacity (% )
Capacity (% )

80 0 .2 C A
60
10℃
60
20℃
1 .0 C A 40
40℃ 30℃
40
2 .0 C A
3 .0 C A 20
20

0 0
-20 -10 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 18 20 22 24
Temperature (℃) Storage Time(months)

Effect of Temperature on Long Term Life Relationship of OCV And State of Charge(20℃)
20 2.20

2.15
Battery Voltage (V)
Lift Expectancy (y ears)

16
2.10

2.05
12

2.00

8
1.95

1.90
4
1.85

0 1.80
0 10 20 30 40 50 0 10 20 30 40 50 60 70 80 90 100
Temperature(℃) State Of Capacity (%)