Professional Documents
Culture Documents
TA-CI Submittal #18 - FT Consejeria BT346310
TA-CI Submittal #18 - FT Consejeria BT346310
Related items
336982 LIVINGLIGHT white series 8 pole socket for table-top installation of the
15 14 13 12 11
switchboard
336803 (8 poles - frayed) cable for table-top installation of the switchboard
346020 2 DIN additional power supply
Technical data
Power supply from SCS BUS: 19 – 27 Vdc Legend
Absorptions from BUS (without additional supply):
- stand by absorption: 35 mA 1. Handset
- max. operating absorption: 450 mA 2. 7” colour LCD display for the displaying of the user and programming menu
Absorptions from BUS (with additional supply): and of the images recorded by the entrance panel or cameras
- stand by absorption: 5 mA 3. Microphone
- max. operating absorption: 20 mA 4. Navigation keypad. It enables navigating through the menus, with the pos-
Operating temperature: 5 - 40 °C sibility of confirming the selection (OK key)
Relay contact output: 24 Vac / 24 Vdc 5. Cancel key
3 A, cosφ = 1
6. Direct call key
Dimensional data 7. Door lock release key
8. Directory access key
9. Entrance panel and camera cycling activation key
10. Handsfree key
290 mm 11. Alarm given indication LED
12. Operating status notification LED:
210 mm
LED ON (fixed)= device in stand-by
LED ON (flashing quickly) = call active
LED ON (flashing slowly) = conversation active
13.Alphanumeric keypad
170 mm
14. Keypad + legend of configurable functions
15. Loudspeaker
170 mm
BT00680-c-EN 03/10/2016
1
2 WIRE Switchboard 346310
To transfer the configuration performed using the software or to update the device,
connect the switchboard to the PC using the USB-mini cable.
5
Legend
1. Mini-USB connector for the connection to the PC
2. Line termination ON/OFF micro-switch
3. Clamps for connection to the BTicino 2 WIRE BUS
4. Additional power supply connection clamps (1 - 2)
5. Audible notification device power supply connection clamps (optional)
Functional notes
The maximum installation distances are the same as for a traditional 2-WIRE
internal unit.
For both one-level (MASTER) and two-level (BACKBONE and RISER) systems a SLAVE
switchboard can be inserted which will have the same functions as the switchboard to
which it is associated; this can be BACKBONE, RISER or MASTER indifferently.
BT00680-c-EN 03/10/2016
2
2 WIRE Switchboard 346310
Wiring diagrams
System with a single riser and a 2 WIRE switchboard
230 Vac
346020
PRI
1- 2
BUS 2 1
F441 346000
PRI
N NF
346000 CEBEC
PRI 230 V~ 50 - 60 Hz 260 mA
BUS
}
2 - 1 27V 1,2A IP30
BUS 2 1
230 Vac
Main EP
(P = 1)
BT00680-c-EN 03/10/2016
3
2 WIRE Switchboard 346310
System with a switchboard independent risers and possible alarm display from common parts in backbone
M =2 M
ON OF F =1 ON OFF ON OFF =3 – All apartment and common alarms are only managed by the
ON OFF MOD = 5 ON OFF MOD = 5 ON OFF MOD = 5
main switchboard (configured with 0)
230 Vac
OUT
IN
1- 2
IN 1 I N2 IN 3 IN 4 SC S BUS 2 1
2 1
230V a.c .
(P = 1) F422 E46ADCN
I1 =–
OUT I2 =–
I3 =–
F422
I4 =1
C
MOD =3
IN
230V a.c .
3480 4615
Z1 = 9
N° = 2
N1 = 1
N°
AUX
MOD
AUX = 1-9
MOD1 = – NC T - C + -
MOD = –
NC pushbutton Z2 = – pushbutton
N2 = –
NO pushbutton Technical alarm activation MOD2 = 1-9
Alarm Reset
BT00680-c-EN 03/10/2016
4
2 WIRE Switchboard 346310
Riser 1 Riser 2
346851 346851
OUT OUT
IN IN
ON ON
ON OF F ON OFF
=– =– 230V a.c .
M 230 Vac M
=1 =2
MOD = 5 MOD = 5
Riser EP Riser EP
To other interfaces 346851
230 Vac
346020
PRI
1- 2
2 1
BUS
OUT
IN 230 Vac
IN 1 I N2 IN 3 IN 4 SC S BUS 2 1 346020
PRI
230V a.c .
1- 2
BUS 2 1
Main EP
(P = 1)
BT00680-c-EN 03/10/2016
5
2 WIRE Switchboard 346310
Hierarchical system with a backbone SWB and an SWB for each independent riser
WARNING
ITEM DESCRIPTION
346310 Switchboard – An additional power supply with 346020 is recommended
346020 Additional power supply – Refer to the documentation supplied with the product for the Switchboard configuration and its operation
F441 Audio/video node
346000 Power supply – The backbone SWB does not manage the riser EP video signal
– A maximum of 16 SWB can be installe
– Using interface item F422O it is possible to connect the contact interfaces for the management of alarms on the common parts (max.
9 interfaces) - e.g. door/window contacts and technical alarms (gas, water, etc.). Refer to the specific MyHOME documentation
– All apartment and common alarms are only managed by the main switchboard (configured with 0)
346310 Riser SWB = 1 230 Vac 346310 Riser SWB = 2 230 Vac
346020 346020
PRI PRI
1- 2 1- 2
BUS 2 1 BUS 2 1
Riser 1 Riser 2
346851 346851
OUT OUT
IN IN
ON ON
ON OF F ON OFF
OUT 346020
PRI
IN
IN 1 I N2 IN 3 IN 4 SC S BUS 2 1
1- 2
230V a.c .
BUS 2 1
BT00680-c-EN 03/10/2016
6
2 WIRE Switchboard 346310
346020
PRI
1- 2
BUS 2 1
Riser 15
346851
OUT
IN
ON
ON OF F
ON OFF IN 1 I N2 IN 3 IN 4 SC S BUS 2 1
=1 230 Vac
M
=5
MOD = 5
Riser EP
E46ADCN
F422
3480 4615
Z1 = 9 N° N° = 2
AUX
N1 = 1 MOD AUX = 1-9
T - C + -
MOD1 = – MOD = –
Z2 = – NC pushbutton
NO NC pushbutton N2 = –
pushbutton MOD2 = 1-9
Technical alarm activation
Alarm Reset
BT00680-c-EN 03/10/2016
7
2 WIRE Switchboard 346310
Hierarchical system with backbone SWB, riser SWB and Slave SWB on the backbone and on the riser
WARNING
ITEM DESCRIPTION
346310 Switchboard – An additional power supply with 346020 is recommended
346020 Additional power supply – Refer to the documentation supplied with the product for the Switchboard configuration and its operation
F441 Audio/video node
346000 Power supply – The backbone SWB do not manage the riser EP video signal
– A maximum of 16 SWB can be installed
– Use the YouDiagram software for the functional check and calculation of the current absorptions – free download from:
www.professionisti.bticino.it (for Italy) - www.bticino.com (International version).
– The slave SWB follow the day/night settings of the associated SWB
346310 Riser SWB = 1 230 Vac 346310 Slave SWB = 9 230 Vac 346310 Riser SWB = 2 230 Vac 346310 Slave SWB = 10 230 Vac
1- 2 1- 2 1- 2 1- 2
Riser 1 Riser 2
346851 346851
OUT OUT
IN IN
ON ON
ON OF F ON OFF
OUT 346020
PRI
IN
IN 1 I N2 IN 3 IN 4 SC S BUS 2 1
1- 2
230V a.c .
BUS 2 1
Main EP
(P = 1)
BT00680-c-EN 03/10/2016
8
2 WIRE Switchboard 346310
346310 Riser SWB = 7 230 Vac 346310 Slave SWB = 15 230 Vac
PRI PRI
1- 2 1- 2
Riser 7
346851
OUT
IN
ON
ON OFF
ON OFF IN 1 I N2 IN 3 IN 4 SC S BUS 2 1
=– 230V a.c .
M
=7
MOD = 5
Riser EP
PRI
1- 2
2 1 346020
BUS
BT00680-c-EN 03/10/2016
9
2 WIRE Switchboard 346310
Auxiliary services – Additional ringtone (Bell type) remoted via actuator and associated to the SWB
MOD M N/P T
8
1 2 3
1 2 3
Unit
Tens
346210
- Repeat the call and alarms sent to the SWB on Bell type ringtone
- In N/P enter the ten and the units of the associated SWB
89.24 89.12 - The time must not be customised using configurator T
90.24 90.12
230 Vac 91.24 91.12
The contact activates and deactivates following the SWB call times.
346210
BUS
Auxiliary services – Additional ringtone (Bell type) connected directly to the SWB
The contact activates and deactivates following the SWB call times.
Load of relay contacts: 24 Vac / 24 Vdc
3 A, cosφ = 1
8
NO
89.24 89.12
90.24 90.12
230 Vac 91.24 91.12
BT00680-c-EN 03/10/2016
10
2 WIRE Switchboard 346310
To the SWB
OUT
IN
IN 1 I N2 IN 3 IN 4 SC S
To the camera
Possible options
391670
max 3 m Tlc 12 Vdc
150 mA
BT00680-c-EN 03/10/2016
11