You are on page 1of 3

"Unified MDC" Release notes for A-MDC8GDSP-1235

Relesaed On Version Details


NEW : Network Interface
User can change network interface of OS system to use choosed network between UMDC and devices.
※ Tool > Options > Network Interface
New : Import / Export for Connection
To add multiple connections, All Connection List can be exported.
And user can use that file to add newly via Import.
※ All Connection List > Export
※ Add > Import
September 22, 2020 A-MDC8GDSP-1235
New : IP Range Scanning for Add via Ethernet
※ Add > Ethernet > Click "+" button to input IP range.

New : Filter for Connection status in All Connection List


New : IP Settings to change device IP
※ Home >IP Settings
Auto SET ID : Moved to Home tab.
User can set the start ID by "SET ID Range" of Edit Connection

New function : Connect to Server

URL Launcher is working without URL Address input for install from USB option.
May 11, 2020 A-MDC8GDSP-1231 Languages are updated for some parts.

Issue fixed - Power On sequence is not working correctly in Secured Protocol mode with MagicInfo source.

Issue fixed - Other minor bugs.

New Model support. VMR-U, VHR-R, QPR

Added option for Color Tone : Natural

Added option for Auto Power Off : 16 hours

Added option for Input source : Remote Workspace, URL Launcher

Monitor Windows state preservation.


November 26, 2019 A-MDC8GDSP-1228
Picture > Advanced Picture Settings command instant execution.

Issue fixed - Customized domail can be used for sender mail address on gmail.com

Issue fixed - Wrong PIN number set when loading connection in somecases.

Issue fixed - Power On (WOL) is not working sometimes by wrong MAC address using.

Issue fixed - Other minor bugs.

Device connection supports over IPv6 network.

Device connection supports over Secured Protocol.

New models are supported. (QMN, QBN)


October 19, 2018 A-MDC8GDSP-1223
Fault Device Alert uses SSL for external mail servers.

Add new function, "Play via". It has two options, Magicinfo and URL Launcher.

Issue fixed - Timer dialog value was not correct.

New Model Support. "DCJ"

New Picture Mode. "HDR+" (User can`t set it manually.)

Change the option name on Color Tone. "Normal" -> "Standard"


December 13, 2017 A-MDC8GDSP-1217
Issue fixed - Ticker message can be sent Korean text more than 35 characters now.

Issue fixed - Picture size (21:9) was shown as "----" on the device list column. Now it is revised.

Issue fixed - Other minor bugs.

Support variable Ticker length.

Power On sequence is improved related with Network Standby option.


Input source name is updated like this.
└ Media -> MagicInfo S
└ Interl Widi -> Screen Mirroring

New models are supported. (QMH / QHH / RMH)


Fault Device diagnosis data type is changed like this.
July 18, 2017 A-MDC8GDSP-1213 └ Lamp : 0-> Normal // 1 -> Error
└ Temperature : 0 -> Normal // 1 -> Error
└ Birhgtness Sensor : 0 -> None // 1 -> Error // 2 -> Normal
└ No Sync : 0 -> Normal // 1 -> Error
└ FAN : 0 -> Normal // 1 -> Error // 2 -> None

Issue fixed - Software update result shows fail message on some devices.

Issue fixed - Wrong command was sent when Input source is changed to Display Port 2.

Issue fixed - The start position of UMDC main window has not been saved.
New models are supported (OMF / OHF)

Improvement of Power On sequence


April 7, 2017 A-MDC8GDSP-1211 Change the sequence of Ambient Light (UMDC will turn off the Eco sensor when Ambiemt Light is set.)

Change the Device fault option display (Previous : 0, 1 or 2 -> None / Normal / Error)

Software bugs are fixed.

New models are supported. (PMF / PHF series)

└ These TIZEN OS device supports software update. (BEM format file only)

└ New Input source. "Web Browser"

New Models are supported. (QMF series, OH85F)

New Model is supported. (UH46F5)

└ Software Update is possible when RS232 connection also)


December 27, 2016 A-MDC8GDSP-1207
New fuction - Frame Alignment - is added. (System > Frame Alignment)

Display software version of connected devices in grid. (Tool > Edit > Software Version check)

Improvement in Power On sequence when Magic Info source

Improvement in Connection safety

Software Update secnario is improved. Retry is possible for failed devices.

Software bugs are fixed.

UMDC can update simultaneously till 5 devices as maximum.

The Auto Source Switching function is refreshingly added.


March 30, 2016 A-MDC8GDSP-1195
UMDC can be running on Windows 10 OS.

Source change speed is improved for multiple selected devices.

Support software update of UDE-B/C/A model.

Add the defect filter as [VideoWall] (user can find automatically [VideoWall] model through Defect.)
July 21, 2015 A-MDC8GDSP-1180
Update multi languages for some parts of Unified MDC.

Some minor bugs are fixed.

"Auto Power Off" for the Eco solution is refreshingly added in System menu.

It is improved not to update the same fw version.


April 13, 2015 A-MDC8GDSP-1172
Some user interfaces like the "Custom PIP" is modified.

Some minor bugs are fixed.

Support New models for 2015 Golf


February 23, 2015 A-MDC8GDSP-1168 Support Software(Firmware) Update from Local file. (via Local Only now)

Some minor bugs are fixed.

Support SLM SW version management.


August 7, 2014 A-MDC8GDSP-1155
Support the new LFD model, QMD.

April 14, 2014 A-MDC8GDSP-1143 Support new model for 2014

- A-MDC8GDSP-1121 Reday for Virtual Remote Controller


Usage to upgrade LFD`s Software through MDC UNIFIED
※ This setting can be adapted for only some models as below.

1. Run the MDC UNIFIED program and connect the devices which are necessary to be updated via RJ45(Ethernet).

2. Select only 1 device which is to be updated in All Device List and click Software Update icon in Tool tab.

3. Then, MDC UNIFIED will find all devices which have same firmware version name with selected one from All Device List.

4. Now, You can see the popup window with some devices.

5. Select what you want to update, and click Browse to find the correct file .

6. Click Start.

※ If you select a device more than 5, it is that 5 models are updated for the first time in advance.
And the other remaining devices will be successively updated with 5 at a time.

※ The preparation for correct file


a. Download the zip file from Display Solution Download Center at SLM.
b-1. For Main Firmware, unzip the file and choose the *.msd or *.bem format file at image folder.
(Tizen platform devices supports bem forma file only)
b-2. For Sub Micom 1, 2 or 3, choose the zip file to update the device.
(Almost main binary file supports sub micom update automatically)

※ The preparation for correct file when UDE-A/B/C series, OH85F and UH46F5.
a. Get the main binary file.
b. Unzip and get *.bin file. Then, change the file format to *.msd.
c. Make a folder named 'image', and move *.msd file into the folder.
d. Make a 'info.txt' file and open it to edit.
e. Write as 'A-AAAAAAA xxxx.x' (A-AAAAAAA should be same as software version name of device)