Professional Documents
Culture Documents
1
KPI Reference
Introduction: This is page one of the KPI Reference. It summarizes the KPI to let readers perform actions o
corresponding explanation page in the KPI Reference.
Category Name Formula
RRC_SSR =
Accessibility RRC Setup Success
RRCSetupSuccess/RRCSetupAttempt x
KPIs Rate (CU)
100%
RRC_SSR =
Accessibility RRC Setup Success
RRCSetupSuccess/RRCSetupAttempt x
KPIs Rate (CU, Inactive)
100%
RRC_SSRservice =
Accessibility RRC Setup Success
RRCSetupSuccessservice/RRCSetupAttempt
KPIs Rate (Service) (CU)
service x 100%
RRC_SSRsignaling =
Accessibility RRC Setup Success
RRCSetupSuccesssignaling/RRCSetupAttem
KPIs Rate (Signaling) (CU)
ptsignaling x 100%
RRC Setup Success RRC_SSRsignaling =
Accessibility
Rate (Signaling) (CU, RRCSetupSuccesssignaling/RRCSetupAttem
KPIs
Inactive) ptsignaling x 100%
CSSR =
(RRCSetupSuccessservice/RRCSetupAttempt
service) x
Accessibility Call Setup Success
(NGSIGConnectionEstablishSuccess/NGSIG
KPIs Rate (CU)
ConnectionEstablishAttempt) x
(QosFlowSetupSuccess/QosFlowSetupAttem
pt) x 100%
CSSR =
(RRCSetupSuccessservice/RRCSetupAttempt
service) x
Accessibility Call Setup Success
(NGSIGConnectionEstablishSuccess/NGSIG
KPIs Rate (CU, Inactive)
ConnectionEstablishAttempt) x
(QosFlowSetupSuccess/QosFlowSetupAttem
pt) x 100%
VoIP_CDR =
Retainability Call Drop Rate (CU,
VoNRQosFlowAbnormalRelease/VoNRQosFl
KPIs VoNR)
owRelease x 100%
Intra-frequency IntraFreqHOOut_SR =
Mobility KPIs Handover Out Success IntraFreqHOOutSuccess/IntraFreqHOOutAtte
Rate (CU) mpt x 100%
Inter-frequency InterFreqHOOut_SR =
Mobility KPIs Handover Out Success InterFreqHOOutSuccess/InterFreqHOOutAtte
Rate (CU) mpt x 100%
Intra-RATHOIn_SR = Intra-
Intra-RAT Handover In
Mobility KPIs RATHOInSuccess/Intra-RATHOInAttempt x
Success Rate (CU)
100%
NSA DC SgNBAbnormalReleaseRate =
Accessibility SgNB Abnormal (MeNBTriSgNBAbnormalRelease +
and Mobility Release Rate (CU) SgNBTriSgNBAbnormalRelease)/SgNBRelea
KPIs se x 100%
BSC6810
V200R011C00SPC3
00
to let readers perform actions on the data, such as filtering, sorting, or other Excel functions. Counter
Performance For more information about the
Reference Summary
Associated Counters ObjectBSC6810
V200R011C00SPC3
RRC Setup Success Rate (CU) = 00
Cell or RAN
N.RRC.SetupReq.Succ/N.RRC.SetupReq.Att x 100%
ons. For more information about the KPIs, please see the
nce Counter
e Summary
Unit/Range Note
1C00SPC3
% None
% None
% None
The KPI formula for the
RRC_INACTIVE state applies to
% scenarios with the inactive switch
turned on or turned off. It can be used
as a common formula.
% None
% None
% None
% None
The KPI formula for the
RRC_INACTIVE state applies to
% scenarios with the inactive switch
turned on or turned off. It can be used
as a common formula.
% None
% None
% None
% None
% None
% None
Gbit/s None
Gbit/s None
Gbit/s None
Gbit/s None
% None
% None
% None
% None
kbit None
kbit None
N/A None
N/A None
% None
% None
% None
% None
% None
% None
% None